1000 resultados para Estação de tratamento de esgoto
Resumo:
The current study examined spatial-temporal modifications and water quality through chemical and biotic indicators during both dry (January, February and November 2006) and wet seasons (March to June 2006). This study was carried out in Armando Ribeiro Gonçalves Reservoir, RN, Canal do Pataxó and after the water station treatment (WST). The physical-chemical parameters were measured in situ and inorganic nutrients, chlorophyll a and Free Oxygen Demand (FOD) were analyzed in laboratory conditions. Quali quantitative analyses of phytoplankton were carried out utilizing Sedgwick-Rafter camera. Results indicate that DQO concentrations were low. FOD concentrations in the reservoir were comparatively higher in the dry season (5.21 mgL-1; 5.64 mgL-1 e 6.05 mgL-1) in relation to the wet season (4.52 mgL-1; 4.12 mgL-1 e 4.92 mgL-1), in surface, intermediate and bottom waters, respectively. FOD values were inferior to 1.0mgL-1in both Canal do Pataxó and after WST, which is considered adequate for public use reservoirs. Although FOD concentrations were low, Armando Ribeiro Gonçalves Reservoir, Canal do Pataxó and WST were classified as euthophizied, mesotrophic ad oligotrophic, respectively, considering the Index of Trophic State Criteria. Chlorophyll a concentrations in the study reservoir were higher in the surface (199.2 µgL-1) during the wet season, whereas in Canal do Pataxó concentrations decreased from 1.56 µgL-1 to 0.028 µgL-1, and after WST values were low (0.059 µgL-1). Dominance of cianobacterias, such as Planktotrhix agardhii (dry season) and Microcystis sp (wet season) was registered in all three areas. In the reservoir and Canal do Pataxó, density of cianobacterias, such as P. agardhii and Microcistys sp., was superior to the values allowed by the Health ministry (HM). However, after WST, density values of cianobacteria were inferior to values established by the HM
Resumo:
A Refinaria de Matosinhos é um dos complexos industriais da Galp Energia. A sua estação de tratamento de águas residuais industriais (ETARI) – designada internamente por Unidade 7000 – é composta por quatro tratamentos: o pré-tratamento, o tratamento físico-químico, o tratamento biológico e o pós-tratamento. Dada a interligação existente, é fundamental a otimização de cada um dos tratamentos. Este trabalho teve como objetivos a identificação dos problemas e/ou possibilidades de melhoria do pré-tratamento, tratamento físico-químico e pós-tratamento e principalmente a otimização do tratamento biológico da ETARI. No pré-tratamento verificou-se que a separação de óleos e lamas não era eficaz uma vez que se formam emulsões destas duas fases. Como solução, sugeriu-se a adição de agentes desemulsionantes, que se revelou economicamente inviável. Assim, sugeriu-se como alternativa o recurso a técnicas de tratamento da emulsão gerada, tais como a extração com solvente, centrifugação, ultrassons e micro-ondas. No tratamento físico-químico constatou-se que o controlo da unidade de saturação de ar na água era feito com base na análise visual dos operadores, o que pode conduzir a condições de operação afastadas das ótimas para este tratamento. Assim, sugeriu-se a realização de um estudo de otimização desta unidade com vista à determinação da razão ar/sólidos ótima para este efluente. Para além disto, constatou-se, ainda, que os consumos de coagulante aumentaram cerca de -- % no último ano, pelo que foi sugerido o estudo da viabilidade do processo de eletrocoagulação como substituto do sistema de coagulação existente. No pós-tratamento identificou-se o processo de lavagem dos filtros como sendo a etapa com possibilidade de ser otimizada. Através de um estudo preliminar concluiu-se que a lavagem contínua de um filtro por cada turno melhorava o desempenho dos mesmos. Constatou-se, ainda, que a introdução de ar comprimido na água de lavagem promove uma maior remoção de detritos do leito de areia, no entanto esta prática parece influenciar negativamente o desempenho dos filtros. No caso do tratamento biológico, identificaram-se problemas ao nível do tempo de retenção hidráulico do tratamento biológico II, que apresentou elevada variabilidade. Apesar de identificado concluiu-se que este problema era de difícil solução. Verificou-se, também, que o oxigénio dissolvido não era monitorizado, pelo que se sugeriu a instalação de uma sonda de oxigénio dissolvido numa zona de baixa turbulência do tanque de arejamento. Concluiu-se que o oxigénio era distribuído de forma homogénea por todo o tanque de arejamento e tentou-se identificar quais os fatores que influenciariam este parâmetro, no entanto, dada a elevada variabilidade do efluente e das condições de tratamento, tal não foi possível. Constatou-se, também, que o doseamento de fosfato para o tratamento biológico II era pouco eficiente já Otimização dos sistemas biológicos e melhorias nos tratamentos da ETARI da Refinaria de Matosinhos que em -- % dos dias se verificaram níveis baixos de fosfato no licor misto (< - mg/L). Foi, por isso, proposta a alteração do atual sistema de doseamento por gravidade para um sistema de bomba doseadora. Para além disso verificou-se que os consumos deste nutriente aumentaram significativamente no último ano (cerca de --%), situação que se constatou estar relacionada com um aumento da população microbiana para este período. Foi possível relacionar-se o aparecimento frequente de lamas à superfície dos decantadores secundários com incrementos repentinos de condutividade, pelo que se sugeriu o armazenamento do efluente nas bacias de tempestade, nestas situações. Verificou-se que a remoção de azoto era praticamente ineficaz uma vez que a conversão de azoto amoniacal em nitratos foi muito baixa. Assim, sugeriu-se o recurso à técnica de bio-augmentação ou a transformação do sistema de lamas ativadas num sistema bietápico. Por fim, constatou-se que a temperatura do efluente à entrada da ETARI apresenta valores bastante elevados para o tratamento biológico (aproximadamente de --º C) pelo que se sugeriu a instalação de uma sonda de temperatura no tanque de arejamento de modo a controlar de forma mais eficaz a temperatura do licor misto. Ainda no que diz respeito ao tratamento biológico, foi possível desenvolver-se um conjunto de ferramentas que visaram o funcionamento otimizado deste tratamento. Nesse sentido, foram apresentadas várias sugestões de melhoria: a utilização do índice volumétrico de lamas como indicador da qualidade das lamas em alternativa à percentagem de lamas; foi desenvolvido um conjunto de fluxogramas para a orientação dos operadores de exterior na resolução de problemas; foi criada uma “janela de operação” que pretende ser um guia de apoio à operação; foi ainda proposta a monitorização frequente da idade das lamas e da razão alimento/microrganismo.
Resumo:
O lodo gerado em Estação de Tratamento de Água (ETA) durante as etapas de
floculação e decantação é classificado como resíduo não inerte. Estudos recentes
apontam para uma diminuição na concentração de agrotóxicos, fármacos e Produtos
de Cuidado Pessoal (PCP) em águas, após o seu tratamento. Uma possível explicação
seja que estes compostos possam estar ficando aderidos ao lodo; entretanto, a
investigação desses compostos no lodo de ETA é bastante reduzida. Neste trabalho,
foi realizada a otimização do método QuEChERS com determinação por Cromatografia
Líquida acoplada a Espectrometria de Massas sequencial para analisar agrotóxicos
(atrazina, simazina, clomazona e tebuconazol), fármacos (amitriptilina, cafeína,
diclofenaco e ibuprofeno) e PCP (metilparabeno, propilparabeno, triclocarban e bisfenol
A) em lodo de ETA, uma matriz bastante complexa, constituída basicamente de
compostos inorgânicos (areia, argila e silte) e orgânicos (substâncias húmicas). Após
otimizado, o método apresentou limites de quantificação ente 1 e 50 µg kg-1
e as curvas
analíticas apresentaram valores de r maiores que 0,98. As recuperações variaram entre
50 e 120% com RSD ≤ 15%. O efeito matriz foi avaliado e observou-se a supressão do
sinal para a maioria dos compostos, sendo o efeito compensado utilizando a
quantificação por superposição na matriz. O método foi aplicado em amostras de lodo
de ETA e foram identificados tebuconazol e metilparabeno em concentrações
Resumo:
A presença de metais traço no ambiente está associada às fontes naturais e antropogênicas. O aumento das concentrações desses elementos pode resultar em um desequilíbrio do ecossistema tornando-se um risco potencial para o meio. O metal cromo tem seus efeitos relacionados com sua concentração e com o estado de oxidação em que se apresenta, já que seu estado trivalente é considerando essencial, enquanto que seu estado hexavalente é considerado extremamente tóxico. O objetivo deste trabalho é realizar a especiação química do cromo após ter sido realizada a revalidação analítica, englobando faixa linear de trabalho, limites de detecção e quantificação, exatidão e precisão. Este estudo é essencial tanto pela questão ambiental quanto sanitária, já que a especiação foi realizada em cinco pontos do Estuário da Lagoa dos Patos - dois na Zona Portuária e três no Saco da Mangueira, entre os meses de março e setembro de 2008 e também na Estação de Tratamento de Água que ocorreram entre os meses de janeiro e setembro de 2008. Foram realizadas determinações das frações de Cr (III) ativo, Cr (VI) e Cr (III) não ativo, por Voltametria de Redissolução Catódica. A Fração de Cromo Total foi determinada por Espectrometria de Absorção Atômica. Também foram realizadas in situ determinações dos seguintes parâmetros físicoquímicos: salinidade, pH, Eh, oxigênio dissolvido e temperatura; além dos nutrientes nitrogenados. As determinações não identificaram o metal no estado de oxidação mais tóxico (cromo hexavalente), também não foi identificada a fração de Cr (III) ativo. O metal foi identificado na forma de Cr (III) não-ativo, ou seja, na forma trivalente e complexada por ligantes naturais estáveis. As concentrações de cromo total estiveram sempre abaixo do limite estabelecido pelos órgãos reguladores competentes. Portanto, mesmo com as atividades industriais e portuárias existentes na região, não foram identificadas concentrações ou espécies de cromo que caracterizam um ambiente impactado.
Resumo:
The production of water has become one of the most important wastes in the petroleum industry, specifically in the up stream segment. The treatment of this kind of effluents is complex and normally requires high costs. In this context, the electrochemical treatment emerges as an alternative methodology for treating the wastewaters. It employs electrochemical reactions to increase the capability and efficiency of the traditional chemical treatments for associated produced water. The use of electrochemical reactors can be effective with small changes in traditional treatments, generally not representing a significant additional surface area for new equipments (due to the high cost of square meter on offshore platforms) and also it can use almost the same equipments, in continuous or batch flow, without others high costs investments. Electrochemical treatment causes low environmental impact, because the process uses electrons as reagent and generates small amount of wastes. In this work, it was studied two types of electrochemical reactors: eletroflocculation and eletroflotation, with the aim of removing of Cu2+, Zn2+, phenol and BTEX mixture of produced water. In eletroflocculation, an electrical potential was applied to an aqueous solution containing NaCl. For this, it was used iron electrodes, which promote the dissolution of metal ions, generating Fe2+ and gases which, in appropriate pH, promote also clotting-flocculation reactions, removing Cu2+ and Zn2+. In eletroflotation, a carbon steel cathode and a DSA type anode (Ti/TiO2-RuO2-SnO2) were used in a NaCl solution. It was applied an electrical current, producing strong oxidant agents as Cl2 and HOCl, increasing the degradation rate of BTEX and phenol. Under different flow rates, the Zn2+ was removed by electrodeposition or by ZnOH formation, due the increasing of pH during the reaction. To better understand the electrochemical process, a statistical protocol factor (22) with central point was conducted to analyze the sensitivity of operating parameters on removing Zn2+ by eletroflotation, confirming that the current density affected the process negatively and the flow rate positively. For economical viability of these two electrochemical treatments, the energy consumption was calculated, taking in account the kWh given by ANEEL. The treatment cost obtained were quite attractive in comparison with the current treatments used in Rio Grande do Norte state. In addition, it could still be reduced for the case of using other alternative energy source such as solar, wind or gas generated directly from the Petrochemical Plant or offshore platforms
Resumo:
The industrial effluents are one of the main sources of water pollution. For an appropriate characterization and control of their discharges, the most efficient strategy is the integrated use of chemical, physical and ecotoxicological analyses. The aims of this study were to asses the efficiency of the treatment plant of a textile industry performing acute toxicity tests and physical-chemical analyses of the effluents before and after the treatment, besides evaluate the toxicity of the effluents of the Treatment System of Liquids Effluents (Sistema de Tratamento de Efluentes Líquidos - SITEL) of Distrito Industrial de Natal (DIN) and some of their physical-chemical variables. The species used in the ecotoxicological tests was the fish Danio rerio. The results showed that the treatment plant reduced significantly (around 50%) the toxicity of the raw textile effluent in only three of the seven tests but, in general, it promoted the reduction of the physical-chemical parameters analyzed. The toxicity and the physical-chemical factors of the effluents of SITEL of DIN varied among the tests and show the importance of monitoring their discharges in the Potengi river, one of the most important rivers of the Rio Grande do Norte state
Resumo:
The current study examined spatial-temporal modifications and water quality through chemical and biotic indicators during both dry (January, February and November 2006) and wet seasons (March to June 2006). This study was carried out in Armando Ribeiro Gonçalves Reservoir, RN, Canal do Pataxó and after the water station treatment (WST). The physical-chemical parameters were measured in situ and inorganic nutrients, chlorophyll a and Free Oxygen Demand (FOD) were analyzed in laboratory conditions. Quali quantitative analyses of phytoplankton were carried out utilizing Sedgwick-Rafter camera. Results indicate that DQO concentrations were low. FOD concentrations in the reservoir were comparatively higher in the dry season (5.21 mgL-1; 5.64 mgL-1 e 6.05 mgL-1) in relation to the wet season (4.52 mgL-1; 4.12 mgL-1 e 4.92 mgL-1), in surface, intermediate and bottom waters, respectively. FOD values were inferior to 1.0mgL-1in both Canal do Pataxó and after WST, which is considered adequate for public use reservoirs. Although FOD concentrations were low, Armando Ribeiro Gonçalves Reservoir, Canal do Pataxó and WST were classified as euthophizied, mesotrophic ad oligotrophic, respectively, considering the Index of Trophic State Criteria. Chlorophyll a concentrations in the study reservoir were higher in the surface (199.2 µgL-1) during the wet season, whereas in Canal do Pataxó concentrations decreased from 1.56 µgL-1 to 0.028 µgL-1, and after WST values were low (0.059 µgL-1). Dominance of cianobacterias, such as Planktotrhix agardhii (dry season) and Microcystis sp (wet season) was registered in all three areas. In the reservoir and Canal do Pataxó, density of cianobacterias, such as P. agardhii and Microcistys sp., was superior to the values allowed by the Health ministry (HM). However, after WST, density values of cianobacteria were inferior to values established by the HM
Resumo:
Os mapas temáticos devem refletir fenômenos de forma clara e abrangente, possuir modo de representação condizente ao fenômeno estudado e de fácil entendimento pelo usuário. A partir desta premissa foram elaborados mapas do desempenho da gestão de recursos hídricos em municípios pertencentes às bacias dos rios Piracicaba, Capivari e Jundiaí. Para tanto, foi criado um índice de desempenho da gestão de recursos hídricos a partir dos seguintes indicadores: Atendimento de água, Atendimento de esgoto, Coleta de esgoto, Tratamento de esgoto, Atendimento de coleta de lixo e Índice de qualidade de aterro de resíduos (IQR). Todos os indicadores tem como unidade de medida padronizada 0 a 1 (onde 0=inexistente e 1=100% existente) e o período considerado foi o ano de 2008. Os dados foram obtidos na Companhia Ambiental do Estado de São Paulo – CETESB e no Sistema Nacional de Informações sobre Saneamento Básico – SNIS. Diferentes mapas foram elaborados através do programa Arcgis, em conjuntos que apresentavam o mesmo conteúdo, com formas de representação diferenciadas, visando avaliar a sua comunicação cartográfica. São apresentados os resultados de análises realizadas por 20 indivíduos selecionados (alunos, professores e não estudantes) que indicaram quais mapas eram mais legíveis em termos de clareza, simplicidade e objetidade de conteúdo.
Resumo:
A lei brasileira para Áreas Protegidas (AP) prevê remuneração àquelas AP que protejam manancial cuja água seja explorada por empresas de abastecimento público. Não há, porém, uma metodologia para avaliar o valor dessa remuneração. O presente trabalho apresenta uma proposta metodológica para calcular a economia nos gastos do tratamento da água devido ao abatimento de erosão promovido pela conservação da cobertura vegetal da AP a montante. Esse cômputo baseia-se na diferença do potencial erosivo entre um cenário com AP (I) e outro sem AP (II). A diferença de potencial erosivo indicou a turbidez da água e conseqüentemente o gasto com o agente coagulador usado na estação de tratamento. Essa abordagem foi aplicada no Córrego da Barriguda que abastece a cidade de Pirenópolis (Goiás, Brasil). O potencial erosivo foi computado em ambiente de Sistema de Informações Geográficas usando os fatores de cobertura do solo da Equação Universal de Perda de Solo, que tiveram uma diferença de 287,12% entre os cenários. Esse contraste indicou um aumento na turbidez da água e na dosagem do coagulante. Concluiu-se que a proteção da AP resulta em economia de 64,12% no gasto calculado em relação ao cenário II, sendo esse o valor do serviço ambiental.
Resumo:
Os mapas temáticos devem refletir fenômenos de forma clara e abrangente, possuir modo de representação condizente ao fenômeno estudado e de fácil entendimento pelo usuário. A partir desta premissa foram elaborados mapas do desempenho da gestão de recursos hídricos em municípios pertencentes às bacias dos rios Piracicaba, Capivari e Jundiaí. Para tanto, foi criado um índice de desempenho da gestão de recursos hídricos a partir dos seguintes indicadores: Atendimento de água, Atendimento de esgoto, Coleta de esgoto, Tratamento de esgoto, Atendimento de coleta de lixo e Índice de qualidade de aterro de resíduos (IQR). Todos os indicadores tem como unidade de medida padronizada 0 a 1 (onde 0=inexistente e 1=100% existente) e o período considerado foi o ano de 2008. Os dados foram obtidos na Companhia Ambiental do Estado de São Paulo – CETESB e no Sistema Nacional de Informações sobre Saneamento Básico – SNIS. Diferentes mapas foram elaborados através do programa Arcgis, em conjuntos que apresentavam o mesmo conteúdo, com formas de representação diferenciadas, visando avaliar a sua comunicação cartográfica. São apresentados os resultados de análises realizadas por 20 indivíduos selecionados (alunos, professores e não estudantes) que indicaram quais mapas eram mais legíveis em termos de clareza, simplicidade e objetidade de conteúdo.
Resumo:
Com o objetivo de avaliar produtividade e possíveis alterações na composição químico-bromatológica do capim-mombaça (Panicum maximum cv. Mombaça), quando submetido a diferentes lâminas de efluente do tratamento primário de esgoto sanitário (ETPES), conduziu-se um experimento em delineamento inteiramente casualizado, constituído de cinco tratamentos com quatro repetições. Parcelas cultivadas com capim-mombaça receberam diferentes doses de ETPES, estabelecidas com base na carga de sódio (75, 150, 225 e 300 kg ha-1 de Na). A dose 0 kg ha-1 de Na foi obtida com aplicação de água de poço artesiano. Periodicamente, amostras do capim-mombaça foram coletadas para avaliação da produtividade e análise químico-bromatológica nas folhas das plantas. Valores pertencentes à faixa normal de nutrientes e proteínas, descrita para a forrageira, foram prevalecentes nos quatro cortes realizados. As exceções foram os teores de K e de proteína bruta, observados no quarto corte e considerados baixos. No primeiro corte, em alguns tratamentos os teores de Ca e Mg estiveram abaixo daqueles descritos para a espécie. A produtividade do capim-mombaça aumentou com a dose de ETPES aplicada e com a idade de corte, tendo sido obtida produtividade de matéria verde e matéria seca de 20,7 t ha-1 e 4,4 t ha-1, respectivamente, no quarto corte. Não houve alteração na composição químico-bromatológica do capim.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)