955 resultados para Dollar-gold standard


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective To evaluate the accuracy of computed tomography for local and lymph node staging of Wilms' tumor. Materials and Methods Each case of Wilms' tumor was evaluated for the presence of abdominal lymph nodes by a radiologist. Signs of capsule and adjacent organ invasion were analyzed. Surgical and histopathological results were taken as the gold standard. Results Sensitivity was 100% for both mesenteric and retroperitoneal lymph nodes detection, and specificity was, respectively, 12% and 33%, with positive predictive value of 8% and 11% and negative predictive value of 100%. Signs of capsular invasion presented sensitivity of 87%, specificity of 77%, positive predictive value of 63% and negative predictive value of 93%. Signs of adjacent organ invasion presented sensitivity of 100%, specificity of 78%, positive predictive value of 37% and negative predictive value of 100%. Conclusion Computed tomography tumor showed low specificity and low positive predictive value in the detection of lymph node dissemination. The absence of detectable lymph nodes makes their presence unlikely, and likewise regarding the evaluation of local behavior of tumors.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective The objective of the present study was to evaluate current radiographic parameters designed to investigate adenoid hypertrophy and nasopharyngeal obstruction, and to present an alternative radiographic assessment method. Materials and Methods In order to do so, children (4 to14 years old) who presented with nasal obstruction or oral breathing complaints were submitted to cavum radiographic examination. One hundred and twenty records were evaluated according to quantitative radiographic parameters, and data were correlated with a gold-standard videonasopharyngoscopic study, in relation to the percentage of choanal obstruction. Subsequently, a regression analysis was performed in order to create an original model so the percentage of the choanal obstruction could be predicted. Results The quantitative parameters demonstrated moderate, if not weak correlation with the real percentage of choanal obstruction. The regression model (110.119*A/N) demonstrated a satisfactory ability to “predict” the actual percentage of choanal obstruction. Conclusion Since current adenoid quantitative radiographic parameters present limitations, the model presented by the present study might be considered as an alternative assessment method in cases where videonasopharyngoscopic evaluation is unavailable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

AbstractObjective:To compare the accuracy of computer-aided ultrasound (US) and magnetic resonance imaging (MRI) by means of hepatorenal gradient analysis in the evaluation of nonalcoholic fatty liver disease (NAFLD) in adolescents.Materials and Methods:This prospective, cross-sectional study evaluated 50 adolescents (aged 11–17 years), including 24 obese and 26 eutrophic individuals. All adolescents underwent computer-aided US, MRI, laboratory tests, and anthropometric evaluation. Sensitivity, specificity, positive and negative predictive values and accuracy were evaluated for both imaging methods, with subsequent generation of the receiver operating characteristic (ROC) curve and calculation of the area under the ROC curve to determine the most appropriate cutoff point for the hepatorenal gradient in order to predict the degree of steatosis, utilizing MRI results as the gold-standard.Results:The obese group included 29.2% girls and 70.8% boys, and the eutrophic group, 69.2% girls and 30.8% boys. The prevalence of NAFLD corresponded to 19.2% for the eutrophic group and 83% for the obese group. The ROC curve generated for the hepatorenal gradient with a cutoff point of 13 presented 100% sensitivity and 100% specificity. As the same cutoff point was considered for the eutrophic group, false-positive results were observed in 9.5% of cases (90.5% specificity) and false-negative results in 0% (100% sensitivity).Conclusion:Computer-aided US with hepatorenal gradient calculation is a simple and noninvasive technique for semiquantitative evaluation of hepatic echogenicity and could be useful in the follow-up of adolescents with NAFLD, population screening for this disease as well as for clinical studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Abstract Although digital angiography remains as the gold standard for imaging the celiac arterial trunk and hepatic arteries, multidetector computed tomography in association with digital images processing by software resources represents a useful tool particularly attractive for its non invasiveness. Knowledge of normal anatomy as well as of its variations is helpful in images interpretation and to address surgical planning on a case-by-case basis. The present essay illustrates several types of anatomical variations of celiac trunk, hepatic artery and its main branches, by means of digitally reconstructed computed tomography images, correlating their prevalence in the population with surgical implications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: For the past decade (18)F-fluoro-ethyl-l-tyrosine (FET) and (18)F-fluoro-deoxy-glucose (FDG) positron emission tomography (PET) have been used for the assessment of patients with brain tumor. However, direct comparison studies reported only limited numbers of patients. Our purpose was to compare the diagnostic performance of FET and FDG-PET. METHODS: We examined studies published between January 1995 and January 2015 in the PubMed database. To be included the study should: (i) use FET and FDG-PET for the assessment of patients with isolated brain lesion and (ii) use histology as the gold standard. Analysis was performed on a per patient basis. Study quality was assessed with STARD and QUADAS criteria. RESULTS: Five studies (119 patients) were included. For the diagnosis of brain tumor, FET-PET demonstrated a pooled sensitivity of 0.94 (95% CI: 0.79-0.98) and pooled specificity of 0.88 (95% CI: 0.37-0.99), with an area under the curve of 0.96 (95% CI: 0.94-0.97), a positive likelihood ratio (LR+) of 8.1 (95% CI: 0.8-80.6), and a negative likelihood ratio (LR-) of 0.07 (95% CI: 0.02-0.30), while FDG-PET demonstrated a sensitivity of 0.38 (95% CI: 0.27-0.50) and specificity of 0.86 (95% CI: 0.31-0.99), with an area under the curve of 0.40 (95% CI: 0.36-0.44), an LR+ of 2.7 (95% CI: 0.3-27.8), and an LR- of 0.72 (95% CI: 0.47-1.11). Target-to-background ratios of either FDG or FET, however, allow distinction between low- and high-grade gliomas (P > .11). CONCLUSIONS: For brain tumor diagnosis, FET-PET performed much better than FDG and should be preferred when assessing a new isolated brain tumor. For glioma grading, however, both tracers showed similar performances.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Colorectal cancer (CRC) is the third most common cancer and the fourth leading cause of cancer death worldwide. About 85% of the cases of CRC are known to have chromosomal instability, an allelic imbalance at several chromosomal loci, and chromosome amplification and translocation. The aim of this study is to determine the recurrent copy number variant (CNV) regions present in stage II of CRC through whole exome sequencing, a rapidly developing targeted next-generation sequencing (NGS) technology that provides an accurate alternative approach for accessing genomic variations. 42 normal-tumor paired samples were sequenced by Illumina Genome Analyzer. Data was analyzed with Varscan2 and segmentation was performed with R package R-GADA. Summary of the segments across all samples was performed and the result was overlapped with DEG data of the same samples from a previous study in the group1. Major and more recurrent segments of CNV were: gain of chromosome 7pq(13%), 13q(31%) and 20q(75%) and loss of 8p(25%), 17p(23%), and 18pq(27%). This results are coincident with the known literature of CNV in CRC or other cancers, but our methodology should be validated by array comparative genomic hybridisation (aCGH) profiling, which is currently the gold standard for genetic diagnosis of CNV.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Oral implantology is a common procedure in dentistry, especially for fully or partially edentulous patients. The implants must be placed in the best location from both the aesthetic and functional point of view. Because of this it is increasingly more frequent to resort to regeneration techniques that use substitutes of the bone itself, in order to be able to insert the implants in the most appropriate location. Material and Methodology: A review was performed on the literature from the last ten years based on the following search limitations: "graft materials', 'allograft', 'xenograft', 'autologous graft" and 'dentistry". Results: 241 works were obtained that after reading their respective summaries, they were reduced to 38, and 9 previous works were included in order to summarize the concepts. Discussion: Autologous grafts are the 'gold standard' of the bone regeneration. They have obvious advantages, but they also have drawbacks. This is why allogeneic and xenogeneic tissues are used. The former because of their clear similarity with the recipient's tissue and the latter due to their wide availability. Given that these grafts also have drawbacks, the industry has developed synthetic materials that have properties similar to those of human bone tissue. However, as of today, the ideal material to substitute human bone has not yet been found. In recent years the tendency has been to combine these synthetic materials with the patient's own bone, which is extracted during drilling in implant placement, with bone marrow aspiration, or with bone morphogenetic proteins. Thus the intention is to equip these substances with the osteogenic capacity. Conclusions: There is currently no ideal graft material, with the exception of those materials that come directly from the patient. We hope that in the coming years we will have products that will allow us to perform rehabilitations with better results and provide a better quality of life for our patients, especially those who have more complex situations to resolve, like the patients that are operated on for head and neck cancer

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coronary artery disease (CAD) is a chronic process that evolves over decades and may culminate in myocardial infarction (MI). While invasive coronary angiography (ICA) is still considered the gold standard of imaging CAD, non-invasive assessment of both the vascular anatomy and myocardial perfusion has become an intriguing alternative. In particular, computed tomography (CT) and positron emission tomography (PET) form an attractive combination for such studies. Increased radiation dose is, however, a concern. Our aim in the current thesis was to test novel CT and PET techniques alone and in hybrid setting in the detection and assessment of CAD in clinical patients. Along with diagnostic accuracy, methods for the reduction of the radiation dose was an important target. The study investigating the coronary arteries of patients with atrial fibrillation (AF) showed that CAD may be an important etiology of AF because a high prevalence of CAD was demonstrated within AF patients. In patients with suspected CAD, we demonstrated that a sequential, prospectively ECG-triggered CT technique was applicable to nearly 9/10 clinical patients and the radiation dose was over 60% lower than with spiral CT. To detect the functional significance of obstructive CAD, a novel software for perfusion quantification, CarimasTM, showed high reproducibility with 15O-labelled water in PET, supporting feasibility and good clinical accuracy. In a larger cohort of 107 patients with moderate 30-70% pre-test probability of CAD, hybrid PET/CT was shown to be a powerful diagnostic method in the assessment of CAD with diagnostic accuracy comparable to that of invasive angiography and fractional flow reserve (FFR) measurements. A hybrid study may be performed with a reasonable radiation dose in a vast majority of the cases, improving the performance of stand-alone PET and CT angiography, particularly when the absolute quantification of the perfusion is employed. These results can be applied into clinical practice and will be useful for daily clinical diagnosis of CAD.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Rapid identification and resistance determination of pathogens in clinical specimens is vital for accurate treatment and monitoring of infectious diseases. Antimicrobial drug resistance is increasing globally and healthcare settings are facing this cost-intensive and even life-threatening problem. The incidence of resistant pathogens in Finland has remained relatively steady and manageable at least for the time being. DNA sequencing is the gold standard method for genotyping, mutation analysis, and identification of bacteria. Due to significant cost decrease in recent years, this technique is available to many research and clinical laboratories. Pyrosequencing technique, a rapid real-time DNA sequencing method especially suitable for analyzing fairly short stretches of DNA, was used in this study. Due to its robustness and versatility, pyrosequencing was applied in this study for identification of streptococci and detection of certain mutations causing antimicrobial resistance in different bacteria. Certain streptococcal species such as S. pneumoniae and S. pyogenes are significantly important clinical pathogens. S. pneumoniae causes e.g. pneumonia and otitis media and is one of the most important community-acquired pathogens. S. pyogenes, also known as group A streptococcus, causes e.g. angina and erysipelas. In contrast, the socalled alpha-haemolytic streptococci, such as S. mitis and S. oralis, belong to the normal microbiota, which are regarded to be non-pathogenic and are nearly impossible to identify by phenotypic methods. In this thesis, a pyrosequencing method was developed for identification of streptococcal species based on the 16S rRNA sequences. Almost all streptococcal species could be differentiated from one another by the developed method, including S. pneumoniae from its close relatives S. mitis and S. oralis . New resistance genes and their variants are constantly discovered and reported. In this study, new methods for detecting certain mutations causing macrolide resistance or extended spectrum beta-lactamase (ESBL) phenotype were developed. These resistance detection approaches are not only suitable for surveillance of mechanisms causing antimicrobial resistance but also for routine analysis of clinical samples particularly in epidemic settings. In conclusion, pyrosequencing was found to be an accurate, versatile, cost-effective, and rapid DNA sequencing method that is especially suitable for mutation analysis of short DNA fragments and identification of certain bacteria.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This research aimed to develop a Fuzzy inference based on expert system to help preventing lameness in dairy cattle. Hoof length, nutritional parameters and floor material properties (roughness) were used to build the Fuzzy inference system. The expert system architecture was defined using Unified Modelling Language (UML). Data were collected in a commercial dairy herd using two different subgroups (H1 and H2), in order to validate the Fuzzy inference functions. The numbers of True Positive (TP), False Positive (FP), True Negative (TN), and False Negative (FN) responses were used to build the classifier system up, after an established gold standard comparison. A Lesion Incidence Possibility (LIP) developed function indicates the chances of a cow becoming lame. The obtained lameness percentage in H1 and H2 was 8.40% and 1.77%, respectively. The system estimated a Lesion Incidence Possibility (LIP) of 5.00% and 2.00% in H1 and H2, respectively. The system simulation presented 3.40% difference from real cattle lameness data for H1, while for H2, it was 0.23%; indicating the system efficiency in decision-making.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Surgical drainage is still considered the gold standard treatment of pancreatic abscess. Patients with high surgical risk, however, require alternative therapy. The authors report three cases of pancreatic abscess that were treated endoscopically. In patients who met endoscopic drainage criteria, treatment was effective, though one case did require surgical intervention as a result of gastric puncture point bleeding. After this initial experience, we believe that endoscopic drainage should be considered in selected cases.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective To compare the diagnostic accuracy of the classic Meisels cytologic criteria and the Schneider secondary criteria relative to the hybrid capture method for diagnosing HPV infection. Methods This was a retrospective study performed at a public university hospital. A total of 41 patients with a cytologic diagnosis of HPV infection and 40 HPV-negative patients were selected for review of the cervical-vaginal smears seeking to classical and secondary criteria. A single pathologist reviewed the slides in search of the criteria. The classical and secondary cytologic criteria were compared with the hybrid capture for diagnosing HPV infection. Bartleti test was applied for the age analysis, and Fisher's exact test was used to compare proportions. The tests were considered significant when the probability of rejecting the null hypothesis was less than 5% (p < 0.05). Results The Meisels criteria were less sensitive (34.0%) than the secondary Schneider criteria (57.5%) when compared with the hybrid capture (p < 0.0001), although the specificity of the former criteria was non-significantly higher (91.2% and 67.7%, respectively). In cases of moderate or intense inflammation, the sensitivity and specificity of the Schneider criteria were decreased, 33.3% and 50.0% respectively (p = 0.0115). Conclusions Compared with hybrid capture for diagnosis of HPV infection, the sensitivity of the secondary Schneider criteria was higher than the classical Meisels criteria.Moderate or intense inflammation reduces the sensitivity and specificity of the secondary Schneider criteria for diagnosing HPV infection using the hybrid capture as the gold standard.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The serum neutralization (SN) test is the gold standard method to measure neutralizing antibodies to bovine herpesviruses. However, in view of the further subdivisions of bovine herpesviruses in types/subtypes, defining which virus to use at challenge in SN tests may be difficult. In view of that, this study was carried out to re-evaluate (SN) sensitivity with different types/subtypes of bovine herpesviruses types 1 (BoHV-1) and 5 (BoHV-5) as challenge viruses. Bovine sera (n=810) were collected from two distinct geographic regions and tested by SN with three type 1 viruses (BoHV-1.1 strains "Los Angeles" and "EVI123/98"; BoHV-1.2a strain "SV265/96") and three type 5 viruses (BoHV-5a strain "EVI88/95"; BoHV-5b strain "A663" and BoHV-5c "ISO97/95"). SN tests were performed with a 1 hour incubation of the serum-virus mixtures at 37ºC against 100 TCID50 of each of the viruses. SN sensitivity varied greatly depending on the challenge virus used in the test. The highest sensitivity (327 positive/810 total sera tested; 40.37%) was attained when the positive results to the six viruses were added together. No association could be found between any particular type or subtype of virus and the sensitivity of the test. When positive results to each single strain were considered, SN sensitivity varied from 41.7% to 81.7%, depending on the virus and the geographic region of origin of the sera. Variation was detected even when challenge viruses belonged to the same subtype, where disagreement between positive results reached 41%. These results indicate that one hour incubation SN tests against single viruses, as performed here, may display a significantly low sensitivity (p=0.05); performing SN tests against a number of different viruses may increase considerably SN sensitivity. Furthermore, the choice of virus used for challenge is critical in SN tests. In addition, sera from different geographic regions may give rise to disagreeing results with different strains of BoHV-1 and BoHV-5. This might be particularly relevant for control programs and in international trade, were maximum sensitivity should be targeted.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Corynebacterium pseudotuberculosis is the etiologic agent of caseous lymphadenitis (CLA), a chronic disease that affects goats and sheep, characterized by granuloma formation in subcutaneous and internal lymph nodes. CLA causes significant economic losses to commercial goat herds. In this study, we aimed to test secreted antigens secreted from T1 strain bacteria grown in brain heart infusion (BHI) broth in an indirect ELISA system to determine the presence of specific immunoglobulins against C. pseudotuberculosis. We analyzed the BHI antigen electrophoretic profile and the recognition pattern by infected sheep sera samples. The ELISA results were compared with multiplex PCR assay and IFN-gamma production. The ELISA was able to discriminate between negative and positive animals, with a sensitivity of 89% and a specificity of 99%, using microbiological isolation as gold standard. When this assay was compared with multiplex PCR and specific IFN-gamma quantification, six discrepant results were found among thirty-two samples. We concluded that the ELISA using antigens secreted from C. pseudotuberculosis T1 strain growth in BHI broth culture can be used for the serodiagnosis of CLA in sheep.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of the present study was to validate the quantitative culture and cellularity of bronchoalveolar lavage (BAL) for the diagnosis of ventilator-associated pneumonia (VAP). A prospective validation test trial was carried out between 1992 and 1997 in a general adult intensive care unit of a teaching hospital. Thirty-seven patients on mechanical ventilation with suspected VAP who died at most three days after a BAL diagnostic procedure were submitted to a postmortem lung biopsy. BAL effluent was submitted to Gram staining, quantitative culture and cellularity count. Postmortem lung tissue quantitative culture and histopathological findings were considered to be the gold standard exams for VAP diagnosis. According to these criteria, 20 patients (54%) were diagnosed as having VAP and 17 (46%) as not having the condition. Quantitative culture of BAL effluent showed 90% sensitivity (18/20), 94.1% specificity (16/17), 94.7% positive predictive value and 88.8% negative predictive value. Fever and leukocytosis were useless for VAP diagnosis. Gram staining of BAL effluent was negative in 94.1% of the patients without VAP (16/17). Regarding the total cellularity of BAL, a cut-off point of 400,000 cells/ml showed a specificity of 94.1% (16/17), and a cut-off point of 50% of BAL neutrophils showed a sensitivity of 90% (19/20). In conclusion, BAL quantitative culture, Gram staining and cellularity might be useful in the diagnostic investigation of VAP.