1000 resultados para Craniofacial Identification
Resumo:
OBJECTIVE: To evaluate and compare the usefulness of cineventriculographies, before and after nitrate use, to technetium-99m sestamibi scintigraphy for the identification of myocardial ischemia. METHODS: Twenty-six patients were studied at basal conditions and 5 minutes after intravenous administration of isosorbide mononitrate (0.3mg/kg), to evaluate the performance and regional wall motion of the left ventricle (LV). The results were compared to those obtained with technetium-99m sestamibi scintigraphy. RESULTS: Before nitrate, contrast ventriculography identified 30 normal segments, 62 hypokinetic segments, 28 dyskinetic segments, and 14 akinetic segments. After drug administration, 99 segments were normal, 11 hypokinetic, 11 dyskinetic, and 13 akinetic. Myocardial scintigraphy revealed 110 ischemic segments and 18 fibrotic segments (p<0.005). After drug administration, the ventriculography showed increase in the velocity of circumferential fiber shortening (p=0.0142), the ejection fraction (p=0.0462), decrease in the end-systolic volume (p=0.0031) and no change in end-diastolic volume. CONCLUSION: Contrast ventriculography using nitrate proved to be similar to perfusional myocardial scintigraphy in the identification of myocardial ischemia.
Resumo:
OBJECTIVE: To study electrophysiological characteristics that enable the identification and ablation of sites of chagasic tachycardia. METHODS: Thirty-one patients with chronic Chagas' heart disease and sustained ventricular tachycardia (SVT) underwent electrophysiological study to map and ablate that arrhythmia. Fifteen patients had hemodinamically stable SVT reproducible by programmed ventricular stimulation, 9 men and 6 women with ages ranging from 37 to 67 years and ejection fraction varying from 0.17 to 0.64. Endocardial mapping was performed during SVT in all patients. Radiofrequency (RF) current was applied to sites of presystolic activity of at least 30 ms. Entrainment was used to identify reentrant circuits. In both successful and unsuccessful sites of RF current application, electrogram and entrainment were analyzed. RESULTS: Entrainment was obtained during all mapped SVT. In 70.5% of the sites we observed concealed entrainment and ventricular tachycardia termination in the first 15 seconds of RF current application. In the unsuccessful sites, significantly earlier electrical activity was seen than in the successful ones. Concealed entrainment was significantly associated with ventricular tachycardia termination. Bystander areas were not observed. CONCLUSION: The reentrant mechanism was responsible for the genesis of all tachycardias. In 70.5% of the studied sites, the endocardial participation of the slow conducting zone of reentrant circuits was shown. Concealed entrainment was the main electrophysiological parameter associated with successful RF current application. There was no electrophysiological evidence of bystander regions in the mapped circuits of SVT.
Resumo:
OBJECTIVE: The intracellular Gram-negative bacterium Chlamydia pneumoniae has been associated with atherosclerosis. The presence of Chlamydia pneumoniae has been investigated in fragments of the arterial wall with a technique for DNA identification. METHODS: Arterial fragments obtained from vascular surgical procedures in 58 patients were analyzed. From these patients, 39 were males and the mean age was 65±6 years. The polymerase chain reaction was used to identify the bacterial DNA with a pair of primers that codify the major outer membrane protein (MOMP) of Chlamydia pneumoniae. The amplified product was visualized by electrophoresis in the 2% agarose gel stained with ethidium bromide, and it was considered positive when migrating in the band of molecular weight of the positive controls. RESULTS: Seven (12%) out of the 58 patients showed positive results for Chlamydia pneumoniae. CONCLUSION: DNA from Chlamydia pneumoniae was identified in the arterial wall of a substantial number of patients with atherosclerosis. This association, which has already been described in other countries, corroborates the evidence favoring a role played by Chlamydia pneumoniae in atherogenesis.
Resumo:
Dissertação de mestrado em Molecular Genetics
Resumo:
Tese de Doutoramento em Engenharia Mecânica.
Resumo:
OBJECTIVE - Evaluation of the performance of the QRS voltage-duration product (VDP) for detection of left ventricular hypertrophy (LVH) in spontaneously hypertensive rats (SHR). METHODS - Orthogonal electrocardiograms (ECG) were recorded in male SHR at the age of 12 and 20 weeks, when systolic blood pressure (sBP) reached the average values of 165±3 mmHg and 195±12 mmHg, respectively. Age- and sex- matched normotensive Wistar Kyoto (WKY) rats were used as controls. VDP was calculated as a product of maximum QRS spatial vector magnitude and QRS duration. Left ventricular mass (LVM) was weighed after rats were sacrificed. RESULTS - LVM in SHR at 12 and 20 weeks of age (0.86±0.05 g and 1.05±0.07 g, respectively) was significantly higher as compared with that in WKY (0.65±0.07 g and 0.70±0.02 g). The increase in LVM closely correlated with the sBP increase. VDP did not reflect the increase in LVM in SHR. VDP was lower in SHR as compared with that in WKY, and the difference was significant at the age of 20 weeks (18.2mVms compared with 10.7mVms, p<0.01). On the contrary, a significant increase in the VDP was observed in the control WKY at the age of 20 weeks without changes in LVM. The changes in VDP were influenced mainly by the changes in QRSmax. CONCLUSION - LVM was not the major determinant of QRS voltage changes and consequently of the VDP. These data point to the importance of the nonspatial determinants of the recorded QRS voltage in terms of the solid angle theory.
Resumo:
The aim of this study is to answer the research question "can customer service be revitalised through identification of a symbiotic relationship with social responsibility, linked by people-centricity?" The concept of customer service remains weak and there has been a lack of attention to the underlying purpose: "to serve". To strengthen the theory the humanistic nature of the concept should be revised. Fundamental to this argument is the question of who is a customer? To fully discover the scope of the concept requires a broader or more specifically a societal view. Herein the theme of social corporate responsibility is critical to the recognition of the customer service network (CSN). This suggestion in isolation is useful but structural. Another aspect must be identified to validate the "service" ethos. Through this reasoning the relational theme (RT) provides for a mechanism for this to be achieved. Therefore the theory of socially integrative customer service is based on broadening and deepening the customer service concept. This study is illustrated in the context of the grocery retail sector in the Republic of Ireland. Four case studies are presented, three based on company-wide and in-store research and a fourth is a cross-company study. Results across companies indicate acceptance of the research question and show evidence to validate SICS. There is scope to further develop SICS and to build on the CSN and the RT. Finally the concept of SICS provides for a diverse basis for further research. This theory does no purport to cause a paradigm shift but does add innovation to the body of knowledge. As is the hallmark of good theoretical development, the author has aimed to keep the philosophy simple.
Resumo:
Systemidentification, evolutionary automatic, data-driven model, fuzzy Takagi-Sugeno grammar, genotype interpretability, toxicity-prediction
Resumo:
Biosignals processing, Biological Nonlinear and time-varying systems identification, Electomyograph signals recognition, Pattern classification, Fuzzy logic and neural networks methods
Resumo:
Magdeburg, Univ., Fak. für Naturwiss., Diss., 2013
Resumo:
Magdeburg, Univ., Fak. für Informatik, Diss., 2014
Resumo:
Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2014