910 resultados para Correction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Suburethral slings are commonly used for the surgical treatment of female stress incontinence; occasionally they can cause erosion and dyspareunia. OBJECTIVES: The primary aim of this study is to determine the outcome after reclosure of the vaginal epithelium for suburethral sling erosion. Sexual function was assessed before and after intervention using the Female Sexual Function Index (FSFI) questionnaire. DESIGN, SETTING, AND PARTICIPANTS: This was a prospective case-controlled study in which, between December 2005 and December 2007, we included patients who were referred to the Department of Urogynaecology because of vaginal erosion after suburethral sling insertion for urinary stress incontinence. For evaluation of sexual function, all patients filled in an FSFI questionnaire before intervention and at follow-up. All patients underwent gynaecological examination including colposcopy, and the site and size of the defect were noted. INTERVENTION: The edge of the vaginal epithelium was trimmed, mobilized, and closed with interrupted vertical Vicryl mattress sutures in a single layer. MEASUREMENTS: FSFI questionnaire and clinical findings. RESULTS AND LIMITATIONS: Twenty-one patients were included in the study. Eighteen patients with larger defects were operated on, and three defects healed after topical application of estrogen cream. In 16 patients, the defect had healed at follow-up; two patients with persisting defects were brought back to surgery and the procedure was repeated, paying particular attention to tension-free adaptation of vaginal tissue. In one patient, partial sling removal was performed after the second failed intervention. The domains of desire (p<0.0001), arousal (p<0.0003), lubrication (p<0.0001), satisfaction (p<0.0130), and pain (p<0.0001) improved significantly. Orgasm remained unchanged (p=0.4130; all two-tailed t-test). CONCLUSION: Suburethral erosion can be treated effectively by resuturing. Sexual function is improved in regard to desire, arousal, lubrication, satisfaction, and pain, but not orgasm. In septic patients and patients with a history of radiation, grossly infected tissue, or severe pain, excision of the mesh needs to be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Switching mode power supplies (SMPS) are subject to low power factor and high harmonic distortions. Active power-factor correction (APFC) is a technique to improve the power factor and to reduce the harmonic distortion of SMPSs. However, this technique results in double frequency output voltage variation which can be reduced by using a large output capacitance. Using large capacitors increases the cost and size of the converter. Furthermore, the capacitors are subject to frequent failures mainly caused by evaporation of the electrolytic solution which reduce the converter reliability. This thesis presents an optimal control method for the input current of a boost converter to reduce the size of the output capacitor. The optimum current waveform as a function of weighing factor is found by using the Euler Lagrange equation. A set of simulations are performed to determine the ideal weighing which gives the lowest possible output voltage variation as the converter still meets the IEC-61000-3-2 class-A harmonics requirements with a power factor of 0.8 or higher. The proposed method is verified by the experimental work. A boost converter is designed and it is run for different power levels, 100 W, 200 W and 400 W. The desired output voltage ripple is 10 V peak to peak for the output voltage of 200 Vdc. This ripple value corresponds to a ± 2.5% output voltage ripple. The experimental and the simulation results are found to be quite matching. A significant reduction in capacitor size, as high as 50%, is accomplished by using the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This contribution discusses the effects of camera aperture correction in broadcast video on colour-based keying. The aperture correction is used to ’sharpen’ an image and is one element that distinguishes the ’TV-look’ from ’film-look’. ’If a very high level of sharpening is applied, as is the case in many TV productions then this significantly shifts the colours around object boundaries with hight contrast. This paper discusses these effects and their impact on keying and describes a simple low-pass filter to compensate for them. Tests with colour-based segmentation algorithms show that the proposed compensation is an effective way of decreasing the keying artefacts on object boundaries.