934 resultados para Computer-aided Translation (CAT)
Resumo:
We present algorithms for computing the differential geometry properties of intersection Curves of three implicit surfaces in R(4), using the implicit function theorem and generalizing the method of X. Ye and T. Maekawa for 4-dimension. We derive t, n, b(1), b(2) vectors and curvatures (k(1), k(2), k(3)) for transversal intersections of the intersection problem. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
The great interest observed in wireless communication systems has required the development of new configurations of microstrip antennas, because they are easily built and integrated to other microwave circuit components, which is suitable for the construction and development of planar antenna arrays and microwave integrated circuits. This work presents a new configuration of tapered microstrip antenna, which is obtained by impressing U-slots on the conducting patch combined with a transmission line matching circuit that uses an inset length. It is shown that the use of U-slots in the microstrip antenna conducting patch excites new resonating modes, that gives a multiband characteristic for the slotted microstrip antenna, that is suitable for applications in communication systems that operates several frequencies simultaneously. Up to this date, the works reported in the literature deals with the use of Uslotted microstrip rectangular antennas fed by a coaxial probe. The properties of a linear array of microstrip patch tapered antennas are also investigated. The main parameters of the U slotted tapered microstrip antennas are investigated for different sizes and locations of the slots impressed on the conducting patch. The analysis of the proposed antenna is performed by using the resonant cavity and equivalent transmission line methods, in combination with a parametric study, that is conducted by the use of the Ansoft Designer, a commercial computer aided microwave software well known by its accuracy and efficiency. The mentioned methods are used to evaluate the effect in the antennas parameters, like resonant frequency and return loss, produced by variations of the antenna structural parameters, accomplished separately or simultaneously. An experimental investigation is also developed, that consists of the design, construction and measurement of several U slotted microstrip antenna prototypes. Finally, theoretical and simulated results are presented that are in agreement with the measured ones. These results are related to the resonating modes identification and to the determination of the main characteristics of the investigated antennas, such as resonant frequency, return loss, and radiation pattern
Resumo:
The aim of present study was to evaluate frozen canine semen with ACP-106 (R) (Powder Coconut Water) using an in vitro sperm-oocyte interaction assay (SOIA). Ten ejaculates from five stud dogs were diluted in ACP-106 (R) containing 20% egg yolk, submitted to cooling in a thermal box for 40 min and in a refrigerator for 30 min. After this period, a second dilution was performed using ACP-106 (R) containing 20% egg yolk and 12% glycerol. Samples were thawed at 38 degrees C for 1 min. Post-thaw motility was evaluated by light microscopy and by using a computer aided semen analysis (CASA). Plasma membrane integrity and sperm morphology/acrosomal status were evaluated by fluorescent probes (C-FDA/PI) and Bengal Rose respectively. Moreover, frozen-thawed semen was analysed by a SOIA. Subjective post-thaw motility was 52.0 +/- 14.8% and it was significant higher than the total motility estimated by CASA (23.0 +/- 14.8%) because this system considered the egg yolk debris as immotile spermatozoa. Although normal sperm rate and acrosomal integrity evaluated by Bengal Rose stain was 89.6 +/- 3.1 % and 94.3 +/- 3.1 %, respectively, post-thaw percentage of intact plasma membrane was only 35.1 +/- 14.3%. Regarding SOIA, the percentage of interacted oocytes (bound, penetrated and bound and/or penetrated) was 75.3%. Using regression analysis, it was found significant relations between some CASA patterns and data for SOIA. In conclusion, the freezing-thawing procedure using ACP-106 (R) was efficient for maintain the in vitro fertility potential of dog spermatozoa.
Resumo:
Combining the data from conventional semen analysis with oocyte penetration assays should improve the assessment of the fertilizing ability of a semen sample. Thus, the objective of the present study was to evaluate the prognostic value of various semen parameters on the in vitro interactions between frozen-thawed canine sperm and homologous oocytes. Ten ejaculates from five stud dogs (two ejaculates/dog) were collected by digital manipulation. Semen samples were evaluated, extended in Tris-egg yolk-glycerol, frozen and stored in liquid nitrogen, and thawed several weeks later. Samples were evaluated for motility and sperm populations by computer-aided semen analysis (CASA), plasma membrane integrity (carboxy-fluorescein diacetate and propidium iodide), and sperm morphology (Bengal Rose). Thawed spermatozoa were also incubated with homologous oocytes for 18 h in an atmosphere of 5% CO2 and 95% air at 38 degrees C and sperm-oocyte interactions were evaluated. Simple linear regression models were calculated, with sperm parameters as independent variables and sperm-oocyte interactions as the dependent variable. There were significant associations between: percentage of oocytes bound to spermatozoa and beat cross frequency (BCF; R-2 = 63%); percentage of oocytes that interacted with spermatozoa and BCF (R-2 = 73%); and number of penetrated spermatozoa and velocity average pathway (VAP; R-2 = 64%) and velocity straight line (VSL; R-2 = 64%). Although plasma membrane integrity and sperm morphology had little prognostic value for in vitro interactions between canine frozen-thawed sperm and homologous oocytes, some motility patterns (evaluated by CASA) were predictive of in vitro sperm-oocyte interactions. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Computer-aided design/computer-aided manufacturing images can be taken through either direct or indirect imaging. For the indirect systems, the digitalization is obtained from the impression material or cast, and for the direct ones the image is taken directly from the mouth using intraoral scanners.The direct acquisition systems have been constantly improved because these are less invasive, quicker, and more precise than the conventional method. Besides, the digital images can be easily stored for a long time. Therefore, the aim of this paper was to describe and discuss based on the literature the main direct image acquisition systems available on the market: CEREC Bluecam (Sirona), Lava C.O.S. System (3M ESPE), iTero System (Cadent/Straumann), and E4D System (D4D Technologies).
Resumo:
Objectives-The purpose of this study was to predict perinatal outcomes using fetal total lung volumes assessed by 3-dimensional ultrasonography (3DUS) in primary pleural effusion.Methods-Between July 2005 and July 2010, total lung volumes were prospectively estimated in fetuses with primary pleural effusion by 3DUS using virtual organ computer-aided analysis software. The first and last US examinations were considered in the analysis. The observed/expected total lung volumes were calculated. Main outcomes were perinatal death (up to 28 days of life) and respiratory morbidity (orotracheal intubation with mechanical respiratory support >48 hours).Results-Twelve of 19 fetuses (63.2%) survived. Among the survivors, 7 (58.3%) had severe respiratory morbidity. The observed/expected total lung volume at the last US examination before birth was significantly associated with perinatal death (P < .01) and respiratory morbidity (P < .01) as well as fetal hydrops (P < .01) and bilateral effusion (P = .01).Conclusions-Fetal total lung volumes may be useful for the prediction of perinatal outcomes in primary pleural effusion.
Resumo:
The SrWO4 (SWO) powders were synthesized by the polymeric precursor method and annealed at different temperatures. The SWO structure was obtained by X-ray diffraction and the corresponding photoluminescence (PL) spectra was measured. The PL results reveal that the structural order-disorder degree in the SWO lattice influences in the PL emission intensity. Only the structurally order-disordered samples present broad and intense PL band in the visible range. To understand the origin of this phenomenon, we performed quantum-mechanical calculations with crystalline and order-disordered SWO periodic models. Their electronic structures were analyzed in terms of band structure. The appearance of localized levels in the band gap of the order-disordered structure was evidenced and is a favorable condition for the intense PL to occur.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Making diagnoses in oral pathology are often difficult and confusing in dental practice, especially for the lessexperienced dental student. One of the most promising areas in bioinformatics is computer-aided diagnosis, where a computer system is capable of imitating human reasoning ability and provides diagnoses with an accuracy approaching that of expert professionals. This type of system could be an alternative tool for assisting dental students to overcome the difficulties of the oral pathology learning process. This could allow students to define variables and information, important to improving the decision-making performance. However, no current open data management system has been integrated with an artificial intelligence system in a user-friendly environment. Such a system could also be used as an education tool to help students perform diagnoses. The aim of the present study was to develop and test an open case-based decisionsupport system.Methods: An open decision-support system based on Bayes' theorem connected to a relational database was developed using the C++ programming language. The software was tested in the computerisation of a surgical pathology service and in simulating the diagnosis of 43 known cases of oral bone disease. The simulation was performed after the system was initially filled with data from 401 cases of oral bone disease.Results: the system allowed the authors to construct and to manage a pathology database, and to simulate diagnoses using the variables from the database.Conclusion: Combining a relational database and an open decision-support system in the same user-friendly environment proved effective in simulating diagnoses based on information from an updated database.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Teaching a course of special electric loads in a continuing education program to power engineers is a difficult task because they are not familiarized with switching topology circuits. Normally, in a typical program, many hours are dedicated to explain the thyristors switching sequence and to draw the converter currents and terminal voltages waveforms for different operative conditions. This work presents teaching support software in order to optimize the time spent in this task and, mainly to benefit the assimilation of the proposed subjects, studying the static converter under different non-ideal operative conditions.
Resumo:
A linearly-tunable ULV transconductor featuring excellent stability of the processed signal common-mode voltage upon tuning, critical for very-low voltage applications, is presented. Its employment to the synthesis of CMOS gm-C high-frequency and voiceband filters is discussed. SPICE data describe the filter characteristics. For a 1.3 V-supply, their nominal passband frequencies are 1.0 MHz and 3.78 KHz, respectively, with tuning rates of 12.52 KHz/mV and 0.16 KHz/m V, input-referred noise spectral density of 1.3 μV/Hz1/2 and 5.0μV/Hz1/2 and standby consumption of 0.87 mW and 11.8 μW. Large-signal distortion given by THD = 1% corresponds to a differential output-swing of 360 mVpp and 480 mVpp, respectively. Common-mode voltage deviation is less than 4 mV over tuning interval.
Resumo:
This paper presents a high speed current mode CMOS comparator. The comparator was optimized for allows wide range input current 1mA, ±0.5uA resolution and has fast response. This circuit was implemented with 0.8μm CMOS n-well process with area of 120μm × 105μm and operates with 3.3V(±1.65V).