894 resultados para Computer-Aided Engineering (CAD, CAE) and design
Resumo:
Purpose: This work evaluated the osteoconductive properties of autogenous demineralized dentin matrix (ADDM) on surgical bone defects in the parietal bone of rabbits, using the guided bone regeneration technique and polytetrafluoroethylene (PTFE) membrane. Materials and Methods: Surgical bone defects were created in 24 adult rabbits and repaired with either ADDM and PTFE (experimental group) or PTFE alone (control group). The ADDM had been obtained from the central incisors of the experimental rabbits. The rabbits were sacrificed after 15, 30, 60, and 90 days and the defects examined radiographically and histologically. Results: Radiographically, the defects in the experimental animals achieved radiopacity more quickly than the defects in the control group. Discussion: After 15, 30, 60, and 90 days of observation following surgery, the ADDM slices appeared to stimulate new bone formation. The dentin slices were completely incorporated into the new bone tissue and were resorbed during the bone repair. Conclusions: Bone repair was accelerated on the bone defects treated with ADDM when compared to the control group.
Resumo:
This paper presents the analysis and the design of a peak-current-controlled high-power-factor boost rectifier, with slope compensation, operating at constant frequency. The input current shaping is achieved, with continuous inductor current mode, with no multiplier to generate a current reference. The resulting overall circuitry is very simple, in comparison with the average-current-controlled boost rectifier. Experimental results are presented, taken from a laboratory prototype rated at 370 W and operating at 67 kHz. The measured power factor was 0.99, with a input current THD equal to 5.6%, for an input voltage THD equal to 2.26%.
Resumo:
The advance in the graphic computer's techniques and computer's capacity of processing made possible applications like the human anatomic structures modeling, in order to investigate diseases, surgical planning or even provide images for training of Computer Aided Diagnosis (CAD). On this context, this work exhibits an anatomical model of cardiac structures represented in a tridimensional environment. The model was represented with geometrical elements and has anatomical details, as the different tunics that compose the cardiac wall and measures that preserves the characteristics found on real structures. The validation of the anatomical model was made through quantitative comparations with real structures measures, available on specialized literature. The results obtained, evaluated by two specialists, are compatible with real anatomies, respecting the anatomical particularities. This degree of representation will allow the verification of the influence of radiological parameters, morphometric peculiarities and stage of the cardiac diseases on the quality of the images, as well as on the performance of the CAD. © 2010 IEEE.
Resumo:
Includes bibliography
Resumo:
Incluye Bibliografía
Resumo:
Presenta la experiencia de la Division de Transportes y Comunicaciones en el uso de computadores para aplicaciones substantivas. Examina los sistemas aplicados - codigo de puertos, ISIS, TRANDIS, COMPA -; el uso de procesamiento de textos en la preparacion de documentos de investigacion e informes y en la correspondencia, y entrega algunas consideraciones con respecto al uso de los microcomputadores.
Resumo:
One of the most commonly used sampling techniques to capture leaf litter amphibians, lizards and small mammals is a set of pitfall traps with drift fences. However, there are still many speculations concerning the effectiveness of different designs of pitfall traps and the most adequate size of each trap. To address this problem, we conducted the first standardized comparison of patterns of species richness, rank-abundance, and community structure of leaf litter amphibians, lizards and small mammals for two trap designs (I and Y format) and three bucket sizes (35, 62, and 100 L) in a Neotropical forest. Results are very similar for the herpetofauna, regardless of the pitfall trap design or size used, while for small mammals values of species richness were higher for 100 L pitfall traps, as compared to the smaller traps. Therefore, the use of 100 L pitfall traps is recommended to sample the terrestrial vertebrate fauna, in multidisciplinary studies. For surveys aiming only the herpetofauna the use of smaller (35 L) traps is acceptable, taking into consideration the cost-benefits obtained by the smaller traps, in comparison to the larger ones.
Resumo:
The present invention describes a method for transforming chemolithotrophic acidophilic bacteria using electroporation technology. The proposed method allows transforming a bacterial line using a transformation vector, the pAF vector, which contains an origin of vegetative replication that allows the vector to replicate inside the bacteria without altering the natural physiological functions of the latter. Also disclosed is the use of the bacteria modified according to the invention in bioleaching processes of sulphated copper, gold, uranium, nickel, zinc and cobalt ore, inter alia.
Resumo:
This paper considers a study of the anatomical features of the cardiac system and a three-dimensional model of the different tunics that comprise the heart wall, for processing and quality control of radiological images. The structures are built by the layer overlapping method, where a layer can be understood as a slice of the three-dimensional object. The pericardium, myocardium and endocardium were represented with three-dimensional cylinders and hexagons. The spatial arrangement of the cardiac system is determined by an background image of a real model, which values are defined according to the shape of the region and on the anatomical patients characteristics. The results are significant, considering the anatomical structures details, as well as the representation of the thicknesses of the regions of the heart wall. The validation of the anatomical model was accomplished through comparisons with dimensions obtained from a real model and allows verifying that the model is appropriate. The degree of representation will allow the verification of the influence of radiological parameters, morphometric peculiarities and stage of the diseases on the quality of the images, as well as on the performance of the Computer-Aided Diagnosis (CAD).
Resumo:
Purpose: To evaluate the influence of the geometry and design of prosthetic crown preparations on stress distribution in compression tests, using finite element analysis (FEA). Materials and Methods: Six combinations of 3D drawings of all-ceramic crowns (yttria-stabilized zirconia framework and porcelain veneer) were evaluated: F, flat preparation and simplified crown; FC, flat preparation and crown with contact point; FCM, flat preparation and modified crown; A, anatomical preparation and simplified anatomical crown framework; AC, anatomical preparation and crown with contact point; and ACM, anatomical preparation and modified crown. Bonded contact types at all interfaces with the mesh were assigned, and the material properties used were according to the literature. A 200 N vertical load was applied at the center of each model. The maximum principal stresses were quantitatively and qualitatively analyzed. Results: The highest values of tensile stress were observed at the interface between the ceramics in the region under the load application for the simplified models (F and A). Reductions in stress values were observed for the model with the anatomical preparation and modified infrastructure (ACM). The stress distribution in the flat models was similar to that of their respective anatomical models. Conclusions: The modified design of the zirconia coping reduces the stress concentration at the interface with the veneer ceramic, and the simplified preparation can exert a stress distribution similar to that of the anatomical preparation at and near the load point, when load is applied to the center of the crown.
Resumo:
Although low- and middle-income countries still bear the burden of major infectious diseases, chronic noncommunicable diseases are becoming increasingly common due to rapid demographic, epidemiologic, and nutritional transitions. However, information is generally scant in these countries regarding chronic disease incidence, social determinants, and risk factors. The Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) aims to contribute relevant information with respect to the development and progression of clinical and subclinical chronic diseases, particularly cardiovascular diseases and diabetes. In this report, the authors delineate the study's objectives, principal methodological features, and timeline. At baseline, ELSA-Brasil enrolled 15,105 civil servants from 5 universities and 1 research institute. The baseline examination (2008-2010) included detailed interviews, clinical and anthropometric examinations, an oral glucose tolerance test, overnight urine collection, a 12-lead resting electrocardiogram, measurement of carotid intima-media thickness, echocardiography, measurement of pulse wave velocity, hepatic ultrasonography, retinal fundus photography, and an analysis of heart rate variability. Long-term biologic sample storage will allow investigation of biomarkers that may predict cardiovascular diseases and diabetes. Annual telephone surveillance, initiated in 2009, will continue for the duration of the study. A follow-up examination is scheduled for 2012-2013.
Resumo:
Background Current recommendations for antithrombotic therapy after drug-eluting stent (DES) implantation include prolonged dual antiplatelet therapy (DAPT) with aspirin and clopidogrel >= 12 months. However, the impact of such a regimen for all patients receiving any DES system remains unclear based on scientific evidence available to date. Also, several other shortcomings have been identified with prolonged DAPT, including bleeding complications, compliance, and cost. The second-generation Endeavor zotarolimus-eluting stent (E-ZES) has demonstrated efficacy and safety, despite short duration DAPT (3 months) in the majority of studies. Still, the safety and clinical impact of short-term DAPT with E-ZES in the real world is yet to be determined. Methods The OPTIMIZE trial is a large, prospective, multicenter, randomized (1: 1) non-inferiority clinical evaluation of short-term (3 months) vs long-term (12-months) DAPT in patients undergoing E-ZES implantation in daily clinical practice. Overall, 3,120 patients were enrolled at 33 clinical sites in Brazil. The primary composite endpoint is death (any cause), myocardial infarction, cerebral vascular accident, and major bleeding at 12-month clinical follow-up post-index procedure. Conclusions The OPTIMIZE clinical trial will determine the clinical implications of DAPT duration with the second generation E-ZES in real-world patients undergoing percutaneous coronary intervention. (Am Heart J 2012;164:810-816.e3.)