964 resultados para Commission for Evaluation of Medical Events
Resumo:
OBJECTIVE: To determine whether an increase in the rate of undesirable events occurs after care provided by trainees at the beginning of the academic year. DESIGN: Retrospective cohort study using administrative and patient record data. SETTING: University affiliated hospital in Melbourne, Australia. PARTICIPANTS: 19,560 patients having an anaesthetic procedure carried out by first to fifth year trainees starting work for the first time at the hospital over a period of five years (1995-2000). MAIN OUTCOME MEASURES: Absolute event rates, absolute rate reduction, and rate ratios of undesirable events. RESULTS: The rate of undesirable events was higher at the beginning of the academic year compared with the rest of the year (absolute event rate 137 v 107 per 1000 patient hours, relative rate reduction 28%, P<0.001). The overall adjusted rate ratio for undesirable events was 1.40, 95% confidence interval 1.24 to 1.58. This excess risk was seen for all residents, regardless of their level of seniority. The excess risk decreased progressively after the first month, and the trend disappeared fully after the fourth month of the year (rate ratio for fourth month 1.21, 0.93 to 1.57). The most important decreases were for central and peripheral nerve injuries (relative difference 82%), inadequate oxygenation of the patient (66%), vomiting/aspiration in theatre (53%), and technical failures of tracheal tube placement (49%). CONCLUSIONS: The rate of undesirable events was greater among trainees at the beginning of the academic year regardless of their level of clinical experience. This suggests that several additional factors, such as knowledge of the working environment, teamwork, and communication, may contribute to the increase.
Resumo:
Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.
Resumo:
PURPOSE: To evaluate the safety and efficacy of an intravitreal fluocinolone acetonide (FA) implant compared with standard therapy in subjects with noninfectious posterior uveitis (NIPU). DESIGN: Randomized, controlled, phase 2b/3, open-label, multicenter superiority trial. PARTICIPANTS: Subjects with unilateral or bilateral NIPU. METHODS: One hundred forty subjects received either a 0.59-mg FA intravitreal implant (n = 66) or standard of care (SOC; n = 74) with either systemic prednisolone or equivalent corticosteroid as monotherapy (> or =0.2 mg/kg daily) or, if judged necessary by the investigator, combination therapy with an immunosuppressive agent plus a lower dose of prednisolone or equivalent corticosteroid (> or =0.1 mg/kg daily). MAIN OUTCOME MEASURES: Time to first recurrence of uveitis. RESULTS: Eyes that received the FA intravitreal implant experienced delayed onset of observed recurrence of uveitis (P<0.01) and a lower rate of recurrence of uveitis (18.2% vs. 63.5%; P< or =0.01) compared with SOC study eyes. Adverse events frequently observed in implanted eyes included elevated intraocular pressure (IOP) requiring IOP-lowering surgery (occurring in 21.2% of implanted eyes) and cataracts requiring extraction (occurring in 87.8% of phakic implanted eyes). No treatment-related nonocular adverse events were observed in the implant group, whereas such events occurred in 25.7% of subjects in the SOC group. CONCLUSIONS: The FA intravitreal implant provided better control of inflammation in patients with uveitis compared with systemic therapy. Intraocular pressure and lens clarity of implanted eyes need close monitoring in patients receiving the FA intravitreal implant.
Resumo:
Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.
Resumo:
INTRODUCTION: Web-based e-learning is a teaching tool increasingly used in many medical schools and specialist fields, including ophthalmology. AIMS: this pilot study aimed to develop internet-based course-based clinical cases and to evaluate the effectiveness of this method within a graduate medical education group. METHODS: this was an interventional randomized study. First, a website was built using a distance learning platform. Sixteen first-year ophthalmology residents were then divided into two randomized groups: one experimental group, which was submitted to the intervention (use of the e-learning site) and another control group, which was not submitted to the intervention. The students answered a printed clinical case and their scores were compared. RESULTS: there was no statistically significant difference between the groups. CONCLUSION: We were able to successfully develop the e-learning site and the respective clinical cases. Despite the fact that there was no statistically significant difference between the access and the non access group, the study was a pioneer in our department, since a clinical case online program had never previously been developed.
Resumo:
ABSTRACTObjective:the study has the intention of evaluate the accuracy of computed tomography for the diagnosis of cervical lesions on penetrating neck trauma and also identify the most frequent mechanisms of trauma. Most injured structures, determine the age range and the most prevalent sex.Methods: observational descriptive retrospective study executed by the systematic retrospective review of medical records of all patients victims of penetrating neck trauma that went through surgery and CT scans, admitted into Hospital do Trabalhador, between January 2009 and December 2013.Results:the final sample was of 30 patients, 96.7% of the male sex, the median age was of 28 years old. Most patients suffered injuries by gun (56.7%) and 33,3% suffered stab wounds. The most stricken area of the neck was Zone II (77.8%) and the left side (55.2%). Regarding the structures injured, the CT showed 6.7% lesions on airways but the surgery showed 40% of damaged, with a value of p=0.002. As to damages of the esophagus and pharynx the CT detected 10% of lesions, while surgery found 30% of lesions, therefore with a significant value of p=0.013. As for the analysis the CT showed reliable. As for the analysis of vascular damage, the CT showed to be, in most cases, reliable to the findings during the surgical act.Conclusion:besides the great use of CT for the diagnosis of penetrating neck injuries we can say that this is an exam with low accuracy for the diagnosis of lesions of aerodigestive tract, therefore it is important a clinical correlation for a good diagnosis.as for the vascular lesions and of other structures, the CT had high sensibility and specificity, thus a good exam to be used in overall.
Resumo:
Corporate events as an effective part of marketing communications strategy seem to be underestimated in Finnish companies. In the rest of the Europe and the USA, investments in events are increasing, and their share of the marketing budget is significant. The growth of the industry may be explained by the numerous advantages and opportunities that events provide for attendees, such as face-to-face marketing, enhancing corporate image, building relationships, increasing sales, and gathering information. In order to maximize these benefits and return on investment, specific measurement strategies are required, yet there seems to exist a lack of understanding of how event performance should be perceived or evaluated. To address this research gap, this research attempts to describe the perceptions of and strategies for evaluating corporate event performance in the Finnish events industry. First, corporate events are discussed in terms of definitions and characteristics, typologies, and their role in marketing communications. Second, different theories on evaluating corporate event performance are presented and analyzed. Third, a conceptual model is presented based on the literature review, which serves as a basis for the empirical research conducted as an online questionnaire. The empirical findings are to a great extent in line with the existing literature, suggesting that there remains a lack of understanding corporate event performance evaluation, and challenges arise in determining appropriate measurement procedures for it. Setting clear objectives for events is a significant aspect of the evaluation process, since the outcomes of events are usually evaluated against the preset objectives. The respondent companies utilize many of the individual techniques that were recognized in theory, such as calculating the number of sales leads and delegates. However, some of the measurement tools may require further investments and resources, thus restricting their application especially in smaller companies. In addition, there seems to be a lack of knowledge of the most appropriate methods in different contexts, which take into account the characteristics of the organizing party as well as the size and nature of the event. The lack of inhouse expertise enhances the need for third-party service-providers in solving problems of corporate event measurement.
Resumo:
The stabilizing free energy of ß-trypsin was determined by hydrogen ion titration. In the pH range from 3.0 to 7.0, the change in free energy difference for the stabilization of the native protein relative to the unfolded one (D D G0 titration) was 9.51 ± 0.06 kcal/mol. An isoelectric point of 10.0 was determined, allowing us to calculate the Tanford and Kirkwood electrostatic factor w. This factor presented a nonlinear behavior and indicated more than one type of titratable carboxyl groups in ß-trypsin. In fact, one class of carboxyl group with a pK = 3.91 ± 0.01 and another one with a pK = 4.63 ± 0.03 were also found by hydrogen ion titration of the protein in the folded state
Resumo:
Sixty Piaractus mesopotamicus Holmberg, 1887 (pacu) fry fed a diet containing 0, 50, 100 and 200 mg ascorbic acid/kg dry feed were studied to evaluate the effect on parasitic infestation by the monogenean Anacanthorus penilabiatus Boeger, Husak and Martins, 1995 (Monogenea: Dactylogyridae) for a period of 24 weeks. The temperature of the aquaria was measured daily and remained between 28 and 31oC. At the beginning of the experiment, fish showed 6.15 ± 0.33 cm standard length and 8.64 ± 1.62 g average body weight. A sample of fish was examined and showed 43 ± 17 monogeneans per fish. At the end of the experiment, the gills of control and vitamin C-treated fish were collected for parasite counts. Control fish had 42.5 parasites per fish, a significantly higher number (P<0.05) when compared with fish fed vitamin C, that showed 16.5 parasites per fish. Ascorbic acid fortification in the food promoted an increase in fish resistance to parasites. It is suggested that an optimum level of 139 mg/kg vitamin C supplementation either elicited better nutritional conditions by stimulating the appetite of the fish or improved the immune response.
Resumo:
The purpose of the present study was to examine the relationship between the electromyographic (EMG) activity and heart rate (HR) responses induced by isometric exercise performed by knee extension (KE) and flexion (KF) in men. Fifteen healthy male subjects, 21 ± 1.3 years (mean ± SD), were submitted to KE and KF isometric exercise tests at 100% of maximal voluntary contraction (MVC). The exercises were performed with one leg (right or left) and with two legs simultaneously, for 10 s in the sitting position with the hip and knee flexed at 90o. EMG activity (root mean square values) and HR (beats/min) were recorded simultaneously both at rest and throughout the sustained contraction. The HR responses to isometric exercise in KE and KF were similar when performed with one and two legs. However, the HR increase was always significantly higher in KE than KF (P<0.05), whereas the EMG activity was higher in KE than in KF (P<0.05), regardless of the muscle mass (one or two legs) involved in the effort. The correlation coefficients between HR response and the EMG activity during KE (r = 0.33, P>0.05) and KF (r = 0.15, P>0.05) contractions were not significant. These results suggest that the predominant mechanism responsible for the larger increase in HR response to KE as compared to KF in our study could be dependent on qualitative and quantitative differences in the fiber type composition found in each muscle group. This mechanism seems to demand a higher activation of motor units with a corresponding increase in central command to the cardiovascular centers that modulate HR control.
Resumo:
An anti-carcinoembryonic antigen (CEA) monoclonal antibody (mAb 6D1.1) was evaluated in vitro and in vivo to determine its suitability as a tracer for immunoscintigraphy of colorectal carcinomas. Determination of mAb affinity for CEA showed a constant of association of 0.63 ± 0.11 x 109 M-1. Binding of technetium-99m (99mTc)-6D1.1, labeled by a direct method, to human cultured lineages was highly specific. Binding to only CEA-positive LS-174T cells resulted in a saturable curve inhibited by pre-incubation with unlabeled mAb. No binding at all was observed for the human lineages MeWo (melanoma) or ZR75-30 (breast carcinoma), neither of them expressing CEA cells. Intravenous injection of 99mTc-6D1.1 into nude mice xenografted with human LS-174T tumors resulted in planar images of excellent quality. Localization of an irrelevant mAb labeled with either 99mTc or iodine-125 was never observed in tumor masses. Biodistribution studies on excised tumoral tissue showed retention of 28.48% of the injected dose per gram of LS-174T tumor. The tumor-to-blood ratio was 3.46. The same analysis performed on the other three human xenografted tumors studied demonstrated that only the CEA-producing HT-29 (colorectal adenocarcinoma) retained 99mTc-6D1.1 while the other two (ZR75-30 and MeWo) did not. These data demonstrate that this mAb is an adequate tool for targeting CEA-expressing tumors in experimental models.
Resumo:
The aim of this work was to compare the performance of isotope-selective non-dispersive infrared spectrometry (IRIS) for the 13C-urea breath test with the combination of the 14C-urea breath test (14C-UBT), urease test and histologic examination for the diagnosis of H. pylori (HP) infection. Fifty-three duodenal ulcer patients were studied. All patients were submitted to gastroscopy to detect HP by the urease test, histologic examination and 14C-UBT. To be included in the study the results of the 3 tests had to be concordant. Within one month after admission to the study the patients were submitted to IRIS with breath samples collected before and 30 min after the ingestion of 75 mg 13C-urea dissolved in 200 ml of orange juice. The samples were mailed and analyzed 11.5 (4-21) days after collection. Data were analyzed statistically by the chi-square and Mann-Whitney test and by the Spearman correlation coefficient. Twenty-six patients were HP positive and 27 negative. There was 100% agreement between the IRIS results and the HP status determined by the other three methods. Using a cutoff value of delta-over-baseline (DOB) above 4.0 the IRIS showed a mean value of 19.38 (minimum = 4.2, maximum = 41.3, SD = 10.9) for HP-positive patients and a mean value of 0.88 (minimum = 0.10, maximum = 2.5, SD = 0.71) for negative patients. Using a cutoff value corresponding to 0.800% CO2/weight (kg), the 14C-UBT showed a mean value of 2.78 (minimum = 0.89, maximum = 5.22, SD = 1.18) in HP-positive patients. HP-negative patients showed a mean value of 0.37 (minimum = 0.13, maximum = 0.77, SD = 0.17). IRIS is a low-cost, easy to manage, highly sensitive and specific test for H. pylori detection. Storing and mailing the samples did not interfere with the performance of the test.
Resumo:
We evaluated the mechanical behavior of the repaired surfaces of defective articular cartilage in the intercondylar region of the rat femur after a hydrogel graft implant. The results were compared to those for the adjacent normal articular cartilage and for control surfaces where the defects remained empty. Hydrogel synthesized by blending poly(2-hydroxyethyl methacrylate) and poly(methyl methacrylate-co-acrylic acid) was implanted in male Wistar rats. The animals were divided into five groups with postoperative follow-up periods of 3, 5, 8, 12 and 16 weeks. Indentation tests were performed on the neoformed surfaces in the knee joint (with or without a hydrogel implant) and on adjacent articular cartilage in order to assess the mechanical properties of the newly formed surface. Kruskal-Wallis analysis indicated that the mechanical behavior of the neoformed surfaces was significantly different from that of normal cartilage. Histological analysis of the repaired defects showed that the hydrogel implant filled the defect with no signs of inflammation as it was well anchored to the surrounding tissues, resulting in a newly formed articular surface. In the case of empty control defects, osseous tissue grew inside the defects and fibrous tissue formed on the articular surface of the defects. The repaired surface of the hydrogel implant was more compliant than normal articular cartilage throughout the 16 weeks following the operation, whereas the fibrous tissue that formed postoperatively over the empty defect was stiffer than normal articular cartilage after 5 weeks. This stiffness started to decrease 16 weeks after the operation, probably due to tissue degeneration. Thus, from the biomechanical and histological point of view, the hydrogel implant improved the articular surface repair.
Resumo:
A pulsatile pressure-flow model was developed for in vitro quantitative color Doppler flow mapping studies of valvular regurgitation. The flow through the system was generated by a piston which was driven by stepper motors controlled by a computer. The piston was connected to acrylic chambers designed to simulate "ventricular" and "atrial" heart chambers. Inside the "ventricular" chamber, a prosthetic heart valve was placed at the inflow connection with the "atrial" chamber while another prosthetic valve was positioned at the outflow connection with flexible tubes, elastic balloons and a reservoir arranged to mimic the peripheral circulation. The flow model was filled with a 0.25% corn starch/water suspension to improve Doppler imaging. A continuous flow pump transferred the liquid from the peripheral reservoir to another one connected to the "atrial" chamber. The dimensions of the flow model were designed to permit adequate imaging by Doppler echocardiography. Acoustic windows allowed placement of transducers distal and perpendicular to the valves, so that the ultrasound beam could be positioned parallel to the valvular flow. Strain-gauge and electromagnetic transducers were used for measurements of pressure and flow in different segments of the system. The flow model was also designed to fit different sizes and types of prosthetic valves. This pulsatile flow model was able to generate pressure and flow in the physiological human range, with independent adjustment of pulse duration and rate as well as of stroke volume. This model mimics flow profiles observed in patients with regurgitant prosthetic valves.