940 resultados para Catheter Ablation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to analyze trigger activity in the long-term follow-up after left atrial (LA) linear ablation. BACKGROUND Interventional strategies for curative treatment of atrial fibrillation (AF) are targeted at the triggers and/or the maintaining substrate. After substrate modification using nonisolating linear lesions, the activity of triggers is unknown. METHODS With the LA linear lesion concept, 129 patients were treated using intraoperative ablation with minimal invasive surgical techniques. Contiguous radiofrequency energy-induced lesion lines involving the mitral annulus and the orifices of the pulmonary veins without isolation were placed under direct vision. RESULTS After a mean follow-up of 3.6 +/- 0.4 years, atrial ectopy, atrial runs, and reoccurrence of AF episodes were analyzed by digital 7-day electrocardiograms in 30 patients. Atrial ectopy was present in all patients. Atrial runs were present in 25 of 30 patients (83%), with a median number of 9 runs per patient/week (range 1 to 321) and a median duration of 1.2 s/run (range 0.7 to 25), without a significant difference in atrial ectopy and atrial runs between patients with former paroxysmal (n = 17) or persistent AF (n = 13). Overall, 87% of all patients were completely free from AF without antiarrhythmic drugs. CONCLUSIONS A detailed rhythm analysis late after specific LA linear lesion ablation shows that trigger activity remains relatively frequent but short and does not induce AF episodes in most patients. The long-term success rate of this concept is high in patients with paroxysmal or persistent AF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In more than 95% of patients with atrioventricular nodal reentrant tachycardia (AVNRT), curative treatment can be achieved with selective ablation of the slow pathway in the right-sided septum. We report a patient with typical AVNRT who had failed attempts to perform conventional right septal ablation of the slow as well as of the fast pathway and finally underwent successful ablation of the fast pathway on the left side of the interatrial septum using a transseptal approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Idiopathic ventricular tachycardia (VT) often originates from the right ventricular outflow tract (RVOT), but foci deep to the endocardium, in the epicardium, or in the left ventricle are not uncommon. Although these extra-RVOT foci can be targeted with ablation, risks involved are higher and success rates lower. Simple electrocardiographic (ECG) criteria allowing (1) discrimination of RVOT foci from extra-RVOT foci and (2) assessment of the chance of success of a right heart ablation procedure are desirable. METHODS Twenty-five consecutive patients referred for radiofrequency (RF) ablation of idiopathic VT or severely symptomatic idiopathic ventricular premature contractions were included. Localization of VT origin and success rates of VT ablation in the RVOT were analyzed according to the ECG pattern. RESULTS The analysis of the R wave in V2 was the strongest single predictor of whether the VT had an RVOT or an extra-RVOT origin. An R wave amplitude < or =30% of the QRS amplitude designated the VT focus in the RVOT with positive and negative predictive values of 95 and 100%, respectively. Analysis of R wave duration in V2 had similar predictive values, whereas the R/S transition zone in precordial leads had slightly lower predictive values. Seventeen of 20 arrhythmias (85%) with an R wave amplitude < or =30% of the QRS amplitude in V2 could be successfully abolished by an exclusively right heart procedure. CONCLUSIONS The analysis of ECG pattern makes it possible to guide the management of patients with idiopathic VT in predicting the arrhythmias that can be safely targeted with RF ablation from the RVOT with high success rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS In 1999 the consensus statement "living anatomy of the atrioventricular junctions" was published. With that new nomenclature the former posteroseptal accessory pathway (APs) are termed paraseptal APs. The aim of this study was to identify ECG features of manifest APs located in this complex paraseptal space. METHODS AND RESULTS ECG characteristics of all patients who underwent radiofrequency ablation of an AP during a 3 year period were analyzed. Of the 239 patients with one or more APs, 30 patients had a paraseptal AP with preexcitation. Compared to APs within the coronary sinus (CS) or the middle cardiac vein (MCV) the right sided paraseptal APs significantly more often showed an isoelectric delta wave in lead II and/or a negative delta wave in aVR. The left sided paraseptal APs presented a negative delta wave in II significantly more often compared to the right sided APs. CONCLUSIONS According to the site of radiofrequency ablation, paraseptal APs are classified into 4 subgroups: paraseptal right, paraseptal left, inside the CS or inside the MCV. Subtle differences in preexcitation patterns of the delta wave as well as of the QRS complex exist. However, the definitive localization of APs remains reserved to the periinterventional intracardiac electrogram analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Intraoperative radiofrequency (RF) ablation is an effective treatment of atrial fibrillation (AF). However, secondary arrhythmias late after ablation may complicate the patient's course. We report on the incidence, mechanisms, and treatment of gap-related atrial flutter and other secondary arrhythmias during long-term follow-up. METHODS AND RESULTS In 129 patients who underwent intraoperative RF ablation with placement of left atrial linear lesions using minimally invasive surgical techniques, secondary arrhythmias were analyzed during long-term follow-up (20 +/- 6 months). Transient atrial arrhythmias during the first 3 postoperative months were excluded. In 8 (6.2%) of 129 patients, sustained stable secondary arrhythmias were documented. Left atrial, gap-related atrial flutter was observed in 4 patients (3.1%). The flutter was treated by percutaneous RF ablation in 3 patients (2.3%) and with drugs in 1 patient (0.8%). In 2 patients (1.6%), right atrial isthmus-dependent atrial flutter occurred and was treated successfully by percutaneous RF ablation. In 2 patients (1.6%), ectopic right atrial tachycardias occurred and were treated with percutaneous RF ablation. CONCLUSION Late after intraoperative RF ablation of atrial fibrillation, three types of stable secondary arrhythmias were observed in 6% of patients: left atrial gap-related atrial flutter, right atrial isthmus-dependent atrial flutter, and ectopic atrial tachycardia. Gaps after intraoperative RF ablation due to noncontinuous or nontransmural linear lesions may lead to stable left atrial macroreentrant tachycardias, requiring new interventional therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES This study sought to determine the vascular anatomical eligibility for catheter-based renal artery denervation (RDN) in hypertensive patients. BACKGROUND Arterial hypertension is the leading cardiovascular risk factor for stroke and mortality globally. Despite substantial advances in drug-based treatment, many patients do not achieve target blood pressure levels. To improve the number of controlled patients, novel procedure- and device-based strategies have been developed. RDN is among the most promising novel techniques. However, there are few data on the vascular anatomical eligibility. METHODS We retrospectively analyzed 941 consecutive hypertensive patients undergoing coronary angiography and selective renal artery angiography between January 1, 2010, and May 31, 2012. Additional renal arteries were divided into 2 groups: hilar (accessory) and polar (aberrant) arteries. Anatomical eligibility for RDN was defined according to the current guidelines: absence of renal artery stenosis, renal artery diameter ≥4 mm, renal artery length ≥20 mm, and only 1 principal renal artery. RESULTS A total of 934 hypertensive patients were evaluable. The prevalence of renal artery stenosis was 10% (n = 90). Of the remaining 844 patients without renal artery stenosis, 727 (86%) had nonresistant hypertension and 117 (14%) had resistant hypertension; 62 (53%) of the resistant hypertensive and 381 (52%) of the nonresistant hypertensive patients were anatomically eligible for sympathetic RDN. CONCLUSIONS The vascular anatomical eligibility criteria of the current guidelines are a major limiting factor for the utilization of RDN as a therapeutic option. Development of new devices and/or techniques may significantly increase the number of candidates for these promising therapeutic options.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Enterococci are an important cause of central venous catheter (CVC)-associated bloodstream infections (CA-BSI). It is unclear whether CVC removal is necessary to successfully manage enterococcal CA-BSI. METHODS A 12-month retrospective cohort study of adults with enterococcal CA-BSI was conducted at a tertiary care hospital; clinical, microbiological and outcome data were collected. RESULTS A total of 111 patients had an enterococcal CA-BSI. The median age was 58.2 years (range 21 to 94 years). There were 45 (40.5%) infections caused by Entercoccus faecalis (among which 10 [22%] were vancomycin resistant), 61 (55%) by Enterococcus faecium (57 [93%] vancomycin resistant) and five (4.5%) by other Enterococcus species. Patients were treated with linezolid (n=51 [46%]), vancomycin (n=37 [33%]), daptomycin (n=11 [10%]), ampicillin (n=2 [2%]) or quinupristin/dalfopristin (n=2 [2%]); seven (n=6%) patients did not receive adequate enterococcal treatment. Additionally, 24 (22%) patients received adjunctive gentamicin treatment. The CVC was retained in 29 (26.1%) patients. Patients with removed CVCs showed lower rates of in-hospital mortality (15 [18.3%] versus 11 [37.9]; P=0.03), but similar rates of recurrent bacteremia (nine [11.0%] versus two (7.0%); P=0.7) and a similar post-BSI length of hospital stay (median days [range]) (11.1 [1.7 to 63.1 days] versus 9.3 [1.9 to 31.8 days]; P=0.3). Catheter retention was an independent predictor of mortality (OR 3.34 [95% CI 1.21 to 9.26]). CONCLUSIONS To the authors' knowledge, the present article describes the largest enterococcal CA-BSI series to date. Mortality was increased among patients who had their catheter retained. Additional prospective studies are necessary to determine the optimal management of enterococcal CA-BSI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When used in veterinary medicine, central venous catheters are typically inserted through the external jugular vein, with their caudal extension within the cranial vena cava. Radiographic or fluoroscopic guidance is recommended to assist in correctly placing these catheters. This article provides radiologic examples of common central venous catheter malpositions and complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Objective To determine whether antibiotic prophylaxis at the time of removal of a urinary catheter reduces the risk of subsequent symptomatic urinary tract infection. Design Systematic review and meta-analysis of studies published before November 2012 identified through PubMed, Embase, Scopus, and the Cochrane Library; conference abstracts for 2006-12 were also reviewed. Inclusion criteria Studies were included if they examined antibiotic prophylaxis administered to prevent symptomatic urinary tract infection after removal of a short term (≤14 days) urinary catheter. Results Seven controlled studies had symptomatic urinary tract infection after catheter removal as an endpoint; six were randomized controlled trials (five published; one in abstract form) and one was a non-randomized controlled intervention study. Five of these seven studies were in surgical patients. Studies were heterogeneous in the type and duration of antimicrobial prophylaxis and the period of observation. Overall, antibiotic prophylaxis was associated with benefit to the patient, with an absolute reduction in risk of urinary tract infection of 5.8% between intervention and control groups. The risk ratio was 0.45 (95% confidence interval 0.28 to 0.72). The number needed to treat to prevent one urinary tract infection was 17 (12 to 30). Conclusions Patients admitted to hospital who undergo short term urinary catheterization might benefit from antimicrobial prophylaxis when the catheter is removed as they experience fewer subsequent urinary tract infections. Potential disadvantages of more widespread antimicrobial prophylaxis (side effects and cost of antibiotics, development of antimicrobial resistance) might be mitigated by the identification of which patients are most likely to benefit from this approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exposure to urinary catheters is considered the most important risk factor for healthcare-associated urinary tract infection (UTI) and is associated with significant morbidity and substantial extra-costs. In this study, we assessed the impact of urinary catheterisation (UC) on symptomatic healthcare-associated UTI among hospitalized patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental procedure for precise and accurate measurements of isotope abundances by a miniature laser ablation mass spectrometer for space research is described. The measurements were conducted on different untreated NIST standards and galena samples by applying pulsed UV laser radiation (266 nm, 3 ns and 20 Hz) for ablation, atomisation, and ionisation of the sample material. Mass spectra of released ions are measured by a reflectron-type time-of-flight mass analyser. A computer controlled performance optimiser was used to operate the system at maximum ion transmission and mass resolution. At optimal experimental conditions, the best relative accuracy and precision achieved for Pb isotope compositions are at the per mill level and were obtained in a range of applied laser irradiances and a defined number of accumulated spectra. A similar relative accuracy and precision was achieved in the study of Pb isotope compositions in terrestrial galena samples. The results for the galena samples are similar to those obtained with a thermal ionisation mass spectrometer (TIMS). The studies of the isotope composition of other elements yielded relative accuracy and precision at the per mill level too, with characteristic instrument parameters for each element. The relative accuracy and precision of the measurements is degrading with lower element/isotope concentration in a sample. For the elements with abundances below 100 ppm these values drop to the percent level. Depending on the isotopic abundances of Pb in minerals, 207Pb/206Pb ages with accuracy in the range of tens of millions of years can be achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective In order to benefit from the obvious advantages of minimally invasive liver surgery there is a need to develop high precision tools for intraoperative anatomical orientation, navigation and safety control. In a pilot study we adapted a newly developed system for computer-assisted liver surgery (CALS) in terms of accuracy and technical feasibility to the specific requirements of laparoscopy. Here, we present practical aspects related to laparoscopic computer assisted liver surgery (LCALS). Methods Our video relates to a patient presenting with 3 colorectal liver metastases in Seg. II, III and IVa who was selected in an appropriate oncological setting for LCALS using the CAScination system combined with 3D MEVIS reconstruction. After minimal laparoscopic mobilization of the liver, a 4- landmark registration method was applied to enable navigation. Placement of microwave needles was performed using the targeting module of the navigation system and correct needle positioning was confirmed by intraoperative sonography. Ablation of each lesion was carried out by application of microwave energy at 100 Watts for 1 minute. Results To acquire an accurate (less 0.5 cm) registration, 4 registration cycles were necessary. In total, seven minutes were required to accomplish precise registration. Successful ablation with complete response in all treated areas was assessed by intraoperative sonography and confirmed by postoperative CT scan. Conclusions This teaching video demonstrates the theoretical and practical key points of LCALS with a special emphasis on preoperative planning, intraoperative registration and accuracy testing by laparoscopic methodology. In contrast to mere ultrasound-guided ablation of liver lesions, LCALS offers a more dimensional targeting and higher safety control. This is currently also in routine use to treat vanishing lesions and other difficult to target focal lesions within the liver.