845 resultados para Cólica abdominal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: The aim of this study was to measure the radiation dose of dual-energy and single-energy multidetector computed tomographic (CT) imaging using adult liver, renal, and aortic imaging protocols. MATERIALS AND METHODS: Dual-energy CT (DECT) imaging was performed on a conventional 64-detector CT scanner using a software upgrade (Volume Dual Energy) at tube voltages of 140 and 80 kVp (with tube currents of 385 and 675 mA, respectively), with a 0.8-second gantry revolution time in axial mode. Parameters for single-energy CT (SECT) imaging were a tube voltage of 140 kVp, a tube current of 385 mA, a 0.5-second gantry revolution time, helical mode, and pitch of 1.375:1. The volume CT dose index (CTDI(vol)) value displayed on the console for each scan was recorded. Organ doses were measured using metal oxide semiconductor field-effect transistor technology. Effective dose was calculated as the sum of 20 organ doses multiplied by a weighting factor found in International Commission on Radiological Protection Publication 60. Radiation dose saving with virtual noncontrast imaging reconstruction was also determined. RESULTS: The CTDI(vol) values were 49.4 mGy for DECT imaging and 16.2 mGy for SECT imaging. Effective dose ranged from 22.5 to 36.4 mSv for DECT imaging and from 9.4 to 13.8 mSv for SECT imaging. Virtual noncontrast imaging reconstruction reduced the total effective dose of multiphase DECT imaging by 19% to 28%. CONCLUSION: Using the current Volume Dual Energy software, radiation doses with DECT imaging were higher than those with SECT imaging. Substantial radiation dose savings are possible with DECT imaging if virtual noncontrast imaging reconstruction replaces precontrast imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: To test the hypothesis that reduced responsiveness to adrenocorticotropin (ACTH) stimulation before elective major abdominal surgery is associated with an increased incidence of postoperative complications. METHODS: A low-dose (1 microg) ACTH test was performed the day before surgery, during the operation, on the first postoperative day, and before discharge from the hospital in 77 patients undergoing major abdominal surgery (age 62 [47;69] yrs [median, quartiles]; 30 female). Thirty-one patients undergoing minor, non-abdominal surgery (mostly inguinal hernia repair) (age 57 [40;66] yrs; 14 female) served as controls with minor surgical stress. A stimulated plasma cortisol concentration >or=500 nmol/l or an increment of >or=200 nmol/l in response to 1 microg ACTH was defined as normal. Scores for surgical stress and comprehensive risk, postoperative complications, and length of hospital stay (LOS) were assessed. RESULTS: On the day before major abdominal surgery, basal and stimulated plasma cortisol were 242 (165;299) nmol/l and 497 (404;568) nmol/l, respectively. Eighteen (23%) patients had an abnormal ACTH test, and 7 of these (39%) had complications versus 25 (42%) of the 59 patients with normal ACTH tests (P = .992). Surgical stress, comprehensive risk, and intra- and postoperative basal cortisol levels were higher and the response to ACTH stimulation smaller in patients with major abdominal compared to minor surgery. The peri-operative course of ACTH responses was not associated with complications or LOS in abdominal surgery patients. CONCLUSION: In patients scheduled for abdominal surgery, pre-operatively reduced adrenal response to stimulation with 1 microg ACTH is common but not associated with postoperative complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whereas a non-operative approach for hemodynamically stable patients with free intraabdominal fluid in the presence of solid organ injury is generally accepted, the presence of free fluid in the abdomen without evidence of solid organ injury not only presents a challenge for the treating emergency physician but also for the surgeon in charge. Despite recent advances in imaging modalities, with multi-detector computed tomography (CT) (with or without contrast agent) usually the imaging method of choice, diagnosis and interpretation of the results remains difficult. While some studies conclude that CT is highly accurate and relatively specific at diagnosing mesenteric and hollow viscus injury, others studies deem CT to be unreliable. These differences may in part be due to the experience and the interpretation of the radiologist and/or the treating physician or surgeon.A search of the literature has made it apparent that there is no straightforward answer to the question what to do with patients with free intraabdominal fluid on CT scanning but without signs of solid organ injury. In hemodynamically unstable patients, free intraabdominal fluid in the absence of solid organ injury usually mandates immediate surgical intervention. For patients with blunt abdominal trauma and more than just a trace of free intraabdominal fluid or for patients with signs of peritonitis, the threshold for a surgical exploration - preferably by a laparoscopic approach - should be low. Based on the available information, we aim to provide the reader with an overview of the current literature with specific emphasis on diagnostic and therapeutic approaches to this problem and suggest a possible algorithm, which might help with the adequate treatment of such patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study was to determine the sensitivity and specificity for typical abdominal injuries after major blunt trauma in postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The purpose of this study was to compare clinical outcomes and sexual function between transvaginal and transabdominal repairs of vesicovaginal fistulae (VVF). STUDY DESIGN Participants (99 women with VVF at a tertiary referral center) were treated with urinary catheterization for 12 weeks and, if the procedure was unsuccessful, underwent repair either the transvaginal (Latzko) or transabdominal technique. Objective clinical parameters were analyzed; subjective outcomes were recorded prospectively at the 6-month follow-up examination with the use of the female sexual function index to evaluate sexual function and the visual analogue scale to measure general disturbance by the fistula. RESULTS After bladder drainage for 12 weeks, 8 patients had spontaneous fistula closure. Demographic variables were similar in the transvaginal (n = 60) and transabdominal (n = 31) repair groups. The transvaginal procedure showed significantly shorter operation times, less blood loss, and shorter hospital stay. Continence rates 6 months after surgery were 82% (transvaginal) and 90% (transabdominal). Sexual function in the 64 sexually active patients was significantly improved, and overall disturbance by the fistula was reduced with both operative techniques. Neither surgical intervention was superior to the other regarding any domain of sexual function or visual analog scale. CONCLUSION Fistula repair improves sexual function and quality of life with no difference attributable to surgical route. Given this and that operating time, blood loss and length of stay are less with the transvaginal approach, the transvaginal approach is preferred in VVF repair if fistula and patient characteristics are suitable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine the prevalence of and the relationships between the degree and source of hyperandrogenemia, ovulatory patterns and cardiovascular disease risk indicators (blood pressure, indices or amount of obesity and fat distribution) in women with menstrual irregularities seen at endocrinologists' clinic. Design: A cross-sectional study design. Participants: A sample of 159 women with menstrual irregularities, aged 15-44, seen at endocrinologists' clinic. Main Outcome Measures: androgen levels, body mass index (BMI), waist-hip ratio (WHR), systolic and diastolic blood pressure (SBP & DBP), source of androgens, ovulatory activity. Results: The prevalence of hyperandrogenemia was 54.7% in this study sample. As expected, women with acne or hirsutism had an odds ratio 12.5 (95%CI = 5.2-25.5) times and 36 (95%CI = 12.9-99.5) times more likely to have hyperandrogenemia than those without acne or hirsutism. The main findings of this study were the following: Hyperandrogenemic women were more likely to have oligomenorrheic cycles (OR = 3.8, 95%CI = 1.5-9.9), anovulatory cycles (OR = 6.6, 95%CI = 2.8-15.4), general obesity (BMI $\ge$ 27) (OR = 6.8, 95%CI = 2.2-27.2) and central obesity (WHR $\ge$ 127) (OR = 14.5, 95%CI = 6.1-38.7) than euandrogenemic women. Hyperandrogenemic women with non-suppressible androgens had a higher mean BMI (29.3 $\pm$ 8.9) than those with suppressible androgens (27.9 $\pm$ 7.9); the converse was true for abdominal adiposity (WHR). Hyperandrogenemic women had a 2.4 odds ratio (95%CI = 1.0-6.2) for an elevated SBP and a 2.7 odds ratio (95%CI = 0.8-8.8) for elevated DBP. When age differences were accounted for, this relationship was strengthened and further strengthened when sources of androgens were controlled. When the differences in BMI were controlled, the odds ratio for elevated SBP in hyperandrogenemic women increased to 8.8 (95%CI = 1.1-69.9). When the age, the source of androgens, the amount of obesity and the type of obesity were controlled, hyperandrogenemic women had 13.5 (95%CI = 1.1-158.9) odds ratio for elevated SBP. Conclusions: In this study population, the presence of menstrual irregularities are highly predictive for the presence of elevated androgens. Women with elevated androgens have a high risk for obesity, more specifically for central obesity. The androgenemic status is an independent predictor of blood pressure elevation. It is probable that in the general population, the presence of menstrual irregularities are predictive of hyperandrogenemia. There is a great need for a population study of the prevalence of hyperandrogenemia and for longitudinal studies in hyperandrogenemic women (adrenarche to menopause) to investigate the evolution of these relationships. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The majority of radiological reports are lacking a standard structure. Even within a specialized area of radiology, each report has its individual structure with regards to details and order, often containing too much of non-relevant information the referring physician is not interested in. For gathering relevant clinical key parameters in an efficient way or to support long-term therapy monitoring, structured reporting might be advantageous. OBJECTIVE Despite of new technologies in medical information systems, medical reporting is still not dynamic. To improve the quality of communication in radiology reports, a new structured reporting system was developed for abdominal aortic aneurysms (AAA), intended to enhance professional communication by providing the pertinent clinical information in a predefined standard. METHODS Actual state analysis was performed within the departments of radiology and vascular surgery by developing a Technology Acceptance Model. The SWOT (strengths, weaknesses, opportunities, and threats) analysis focused on optimization of the radiology reporting of patients with AAA. Definition of clinical parameters was achieved by interviewing experienced clinicians in radiology and vascular surgery. For evaluation, a focus group (4 radiologists) looked at the reports of 16 patients. The usability and reliability of the method was validated in a real-world test environment in the field of radiology. RESULTS A Web-based application for radiological "structured reporting" (SR) was successfully standardized for AAA. Its organization comprises three main categories: characteristics of pathology and adjacent anatomy, measurements, and additional findings. Using different graphical widgets (eg, drop-down menus) in each category facilitate predefined data entries. Measurement parameters shown in a diagram can be defined for clinical monitoring and be adducted for quick adjudications. Figures for optional use to guide and standardize the reporting are embedded. Analysis of variance shows decreased average time required with SR to obtain a radiological report compared to free-text reporting (P=.0001). Questionnaire responses confirm a high acceptance rate by the user. CONCLUSIONS The new SR system may support efficient radiological reporting for initial diagnosis and follow-up for AAA. Perceived advantages of our SR platform are ease of use, which may lead to more accurate decision support. The new system is open to communicate not only with clinical partners but also with Radiology Information and Hospital Information Systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a case of a ruptured abdominal aortic aneurysm (AAA) with ambiguous accessory findings on post-mortem computed-tomography (PMCT), post-mortem magnetic resonance (PMMR) imaging, and PMCT-angiography (PMCTA) suggestive of thoracic aortic dissection. The diagnosis of ruptured AAA was confirmed by autopsy; however, there was no aortic dissection. The imaging findings that mimicked the presence of aortic dissection might have been an atypical presentation of post-mortem clotting or sedimentation. This case is an ideal example to illustrate benefits, limitations, and challenges of post-mortem cross-sectional imaging. It serves as a reminder that both, training as well as correlation of imaging findings with autopsy are fundamental to improve our understanding of radiologic findings on post-mortem cross-sectional imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accurate measurement of abdominal aortic aneurysms is necessary to predict rupture risk and, more recently, to follow aneurysm sac behavior following endovascular repair. Up until this point, aneurysm diameter has been the most common measurement utilized for these purposes. Although aneurysm diameter is predictive of rupture, accurate measurement is hindered by such factors as aortic tortuosity and interobserver variability, and it does not account for variations in morphology such as saccular aneurysms. Additionally, decreases in aneurysm diameter do not completely describe the somewhat complex remodeling seen following endovascular repair of aortic aneurysms. Measurement of aneurysm volume has the advantage of describing aneurysm morphology in a multidimensional fashion, but it has not been readily available or easily measured until recently. This has changed with the introduction of commercially available software tools that permit quicker and easier to perform volume measurements. Whether it is time for volume to replace, or compliment, diameter is the subject of the current debate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arterial waves are seen as possible independent mediators of cardiovascular risks, and the wave intensity analysis (WIA) has therefore been proposed as a method for patient selection for ventricular assist device (VAD) implantation. Interpreting measured wave intensity (WI) is challenging and complexity is increased by the implantation of a VAD. The waves generated by the VAD interact with the waves generated by the native heart, and this interaction varies with changing VAD settings. Eight sheep were implanted with a pulsatile VAD (PVAD) through ventriculo-aortic cannulation. The start of PVAD ejection was synchronized to the native R-wave and delayed between 0 % - 90 % of the cardiac cycle in 10 % steps or phase shifts (PS). Pressure and velocity signals were registered, using a combined Doppler and pressure wire positioned in the abdominal aorta, and used to calculate the WI. Depending on the PS, different wave interference phenomena occurred. Maximum unloading of the left ventricle (LV) coincided with constructive interference and maximum blood flow pulsatility, and maximum loading of the LV coincided with destructive interference and minimum blood flow pulsatility. We believe, that non-invasive WIA could potentially be used clinically to assess the mechanical load of the LV, and to monitor the peripheral hemodynamics such as blood flow pulsatility and risk of intestinal bleeding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coral reef aorta is a rare form of calcifying atherosclerosis typically involving the supra and juxtarenal aorta. P atients classically present with refractory hypertension, intermittent claudication and abdominal angina. The treatment is either surgical via transaortic endarterectomy or through transferal endovascular stentgraft placement. Here we describe the case of a 45yearold female patient infected with human immuno deficiency virus, with resistant hypertension, lower limb and abdominal claudication, who was successfully treated with endovascular stent placement. We f urther provide a brief overview of the disease characteristics and treatment options.