792 resultados para BIAS-ENHANCED NUCLEATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The propagation of a pulse in a nonlinear array of oscillators is influenced by the nature of the array and by its coupling to a thermal environment. For example, in some arrays a pulse can be speeded up while in others a pulse can be slowed down by raising the temperature. We begin by showing that an energy pulse (one dimension) or energy front (two dimensions) travels more rapidly and remains more localized over greater distances in an isolated array (microcanonical) of hard springs than in a harmonic array or in a soft-springed array. Increasing the pulse amplitude causes it to speed up in a hard chain, leaves the pulse speed unchanged in a harmonic system, and slows down the pulse in a soft chain. Connection of each site to a thermal environment (canonical) affects these results very differently in each type of array. In a hard chain the dissipative forces slow down the pulse while raising the temperature speeds it up. In a soft chain the opposite occurs: the dissipative forces actually speed up the pulse, while raising the temperature slows it down. In a harmonic chain neither dissipation nor temperature changes affect the pulse speed. These and other results are explained on the basis of the frequency vs energy relations in the various arrays

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To study the combination of oligodeoxynucleotides (ODNs) intravitreous injection and saline transpalpebral iontophoresis on the delivery of ODNs to photoreceptors in the newborn rd1/rd1 mice. METHODS: Cathodal or anodal transpalpebral iontophoresis (1.43 mA/cm(2) for 5 min) was applied to eyes of postnatal day 7 (PN7) rd1/rd1 mice immediately before the intravitreous injection of ODNs. The effect of cathodal iontophoresis after ODNs injection was also evaluated. The influence of current intensity (0.5, 1.5, and 2.5 mA) was assayed with cathodal iontophoresis performed prior to ODNs injection. The duration of current-induced facilitation of ODNs delivery to photoreceptors was evaluated for 6 h following iontophoresis. One group of control eyes received cathodal iontophoresis prior to the intravitreous injection of phosphate buffered saline (PBS) or hexachlorofluorescein (Hex). The second control group received ODN or Hex intravitreous injection without iontophoresis. The penetration of fluorescent ODNs in the outer nuclear layer (ONL) was quantified by image analysis of the ONL fluorescence intensity on cryosection microphotographs. Integrity of ODN was assessed using acrylamide gel migration after its extraction from the retina of treated mice. The integrity of retinal structure, 1 and 24 h after iontophoresis, was analyzed using light and electron microscopy. RESULTS: Transpalpebral anodal or cathodal saline iontophoresis enhanced the penetration of ODNs in all retinal layers. Cathodal iontophoresis was more efficient than anodal iontophoresis in enhancing the tissue penetration of the injected ODN. Photoreceptor delivery of ODN was significantly higher when cathodal saline transpalpebral iontophoresis was applied prior than after the injection. The extent of enhanced tissue penetration decreased in parallel to the increased interval between iontophoresis application and the intravitreous injection. Current of 1.5 mA was safe and optimal for the delivery of ODNs to the ONL. One hour after iontophoresis followed by injection, ODN extracted from the retina of treated eyes remained intact. Histology and electron microscopy observations demonstrated that iontophoresis using the optimal parameters did not induce any permanent tissue alterations or structure damage. CONCLUSIONS: Saline transpalpebral iontophoresis facilitates the penetration of injected ODNs in photoreceptors for at least 3 h. This method may be considered for photoreceptor targeted gene therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Sustained antibody levels are a hallmark of immunity against many pathogens, and induction of long-term durable antibody titers is an essential feature of effective vaccines. Heterologous prime-boost approaches with vectors are optimal strategies to improve a broad and prolonged immunogenicity of malaria vaccines. RESULTS: In this study, we demonstrate that the heterologous prime-boost regimen Ad35-CS/BCG-CS induces stronger immune responses by enhancing type 1 cellular producing-cells with high levels of CSp-specific IFN-γ and cytophilic IgG2a antibodies as compared to a homologous BCG-CS and a heterologous BCG-CS/CSp prime-boost regimen. Moreover, the heterologous prime-boost regimen elicits the highest level of LLPC-mediated immune responses. CONCLUSION: The increased IFN-γ-producing cell responses induced by the combination of Ad35-CS/BCG-CS and sustained type 1 antibody profile together with high levels of LLPCs may be essential for the development of long-term protective immunity against liver-stage parasites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This review aims to present a consensus for optimal perioperative care in colonic surgery and to provide graded recommendations for items for an evidenced-based enhanced perioperative protocol. METHODS: Studies were selected with particular attention paid to meta-analyses, randomised controlled trials and large prospective cohorts. For each item of the perioperative treatment pathway, available English-language literature was examined, reviewed and graded. A consensus recommendation was reached after critical appraisal of the literature by the group. RESULTS: For most of the protocol items, recommendations are based on good-quality trials or meta-analyses of good-quality trials (quality of evidence and recommendations according to the GRADE system). CONCLUSIONS: Based on the evidence available for each item of the multimodal perioperative-care pathway, the Enhanced Recovery After Surgery (ERAS) Society, International Association for Surgical Metabolism and Nutrition (IASMEN) and European Society for Clinical Nutrition and Metabolism (ESPEN) present a comprehensive evidence-based consensus review of perioperative care for colonic surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pursuit of high response rates to minimise the threat of nonresponse bias continues to dominate decisions about resource allocation in survey research. Yet a growing body of research has begun to question this practice. In this study, we use previously unavailable data from a new sampling frame based on population registers to assess the value of different methods designed to increase response rates on the European Social Survey in Switzerland. Using sampling data provides information about both respondents and nonrespondents, making it possible to examine how changes in response rates resulting from the use of different fieldwork methods relate to changes in the composition and representativeness of the responding sample. We compute an R-indicator to assess representativity with respect to the sampling register variables, and find little improvement in the sample composition as response rates increase. We then examine the impact of response rate increases on the risk of nonresponse bias based on Maximal Absolute Bias (MAB), and coefficients of variation between subgroup response rates, alongside the associated costs of different types of fieldwork effort. The results show that increases in response rate help to reduce MAB, while only small but important improvements to sample representativity are gained by varying the type of effort. These findings lend further support to research that has called into question the value of extensive investment in procedures aimed at reaching response rate targets and the need for more tailored fieldwork strategies aimed both at reducing survey costs and minimising the risk of bias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the list of states adopting the HWTD continues to grow, there is a need to evaluate how results are utilized. AASHTO T 324 does not standardize the analysis and reporting of test results. Furthermore, processing and reporting of the results among manufacturers is not uniform. This is partly due to the variation among agency reporting requirements. Some include only the midpoint rut depth, while others include the average across the entire length of the wheel track. To eliminate bias in reporting, statistical analysis was performed on over 150 test runs on gyratory specimens. Measurement location was found to be a source of significant variation in the HWTD. This is likely due to the nonuniform wheel speed across the specimen, geometry of the specimen, and air void profile. Eliminating this source of bias when reporting results is feasible though is dependent upon the average rut depth at the final pass. When reporting rut depth at the final pass, it is suggested for poor performing samples to average measurement locations near the interface of the adjoining gyratory specimens. This is necessary due to the wheel lipping on the mold. For all other samples it is reasonable to only eliminate the 3 locations furthest from the gear house. For multi‐wheel units, wheel side was also found to be significant for poor and good performing samples. After eliminating the suggested measurements from the analysis, the wheel was no longer a significant source of variation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the vast majority of bottom-up proteomics studies, protein digestion is performed using only mammalian trypsin. Although it is clearly the best enzyme available, the sole use of trypsin rarely leads to complete sequence coverage, even for abundant proteins. It is commonly assumed that this is because many tryptic peptides are either too short or too long to be identified by RPLC-MS/MS. We show through in silico analysis that 20-30% of the total sequence of three proteomes (Schizosaccharomyces pombe, Saccharomyces cerevisiae, and Homo sapiens) is expected to be covered by Large post-Trypsin Peptides (LpTPs) with M(r) above 3000 Da. We then established size exclusion chromatography to fractionate complex yeast tryptic digests into pools of peptides based on size. We found that secondary digestion of LpTPs followed by LC-MS/MS analysis leads to a significant increase in identified proteins and a 32-50% relative increase in average sequence coverage compared to trypsin digestion alone. Application of the developed strategy to analyze the phosphoproteomes of S. pombe and of a human cell line identified a significant fraction of novel phosphosites. Overall our data indicate that specific targeting of LpTPs can complement standard bottom-up workflows to reveal a largely neglected portion of the proteome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soil pollution with hexachlorocyclohexane (HCH) has caused serious environmental problems. Here we describe the targeted degradation of all HCH isomers by applying the aerobic bacterium Sphingobium indicum B90A. In particular, we examined possibilities for large-scale cultivation of strain B90A, tested immobilization, storage and inoculation procedures, and determined the survival and HCH-degradation activity of inoculated cells in soil. Optimal growth of strain B90A was achieved in glucose-containing mineral medium and up to 65% culturability could be maintained after 60 days storage at 30 degrees C by mixing cells with sterile dry corncob powder. B90A biomass produced in water supplemented with sugarcane molasses and immobilized on corncob powder retained 15-20% culturability after 30 days storage at 30 degrees C, whereas full culturability was maintained when cells were stored frozen at -20 degrees C. On the contrary, cells stored on corncob degraded gamma-HCH faster than those that had been stored frozen, with between 15 and 85% of gamma-HCH disappearance in microcosms within 20 h at 30 degrees C. Soil microcosm tests at 25 degrees C confirmed complete mineralization of [(14)C]-gamma-HCH by corncob-immobilized strain B90A. Experiments conducted in small pits and at an HCH-contaminated agricultural site resulted in between 85 and 95% HCH degradation by strain B90A applied via corncob, depending on the type of HCH isomer and even at residual HCH concentrations. Up to 20% of the inoculated B90A cells survived under field conditions after 8 days and could be traced among other soil microorganisms by a combination of natural antibiotic resistance properties, unique pigmentation and PCR amplification of the linA genes. Neither the addition of corncob nor of corncob immobilized B90A did measurably change the microbial community structure as determined by T-RFLP analysis. Overall, these results indicate that on-site aerobic bioremediation of HCH exploiting the biodegradation activity of S. indicum B90A cells stored on corncob powder is a promising technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microbial mats are complex but stable, multi-layered and multi-functional biofilms, which are the most frequent bacterial formations in nature. The functional strategies and physiological versatility of the bacterial populations growing in microbial mats allow bacteria to resist changing conditions within their environment. One of these strategies is the accumulation of carbon- and energy-rich polymers that permit the recovery of metabolic activities when favorable conditions are restored. In the present study, we systematically screened microbial mats for bacteria able to accumulate large amounts of the ester carbon polymers polyhydroxyalkanoates (PHA). Several of these strains were isolated from Ebro Delta microbial mats and their ability to accumulate PHA up to 40-60 % of their dry weight was confirmed. According to two identification approaches (16S rRNA and ropD genes), these strains were identified as Halomonas alkaliphila (MAT-7, -13, -16), H. neptunia (MAT-17), and H. venusta (MAT-28). To determine the mode of growth yielding maximum PHA accumulation, these three different species were cultured in an artificial biofilm in which the cells were immobilized on alginate beads. PHA accumulation by cells that had detached from the biofilm was compared with that of their planktonic counterparts. Experiments in different culture media showed that PHA accumulation, measured as the relative fluorescence intensity after 48 h of incubation at 30 °C, was higher in immobilized than in planktonic cells, with the exception of cells growing in 5 % NaCl, in which PHA accumulation was drastically lower in both. Therefore, for obtaining high PHA concentrations, the use of immobilized cells may be a good alternative to the PHA accumulation by bacteria growing in the classical, planktonic mode. From the ecological point of view, increased PHA accumulation in detached cells from biofilms would be a natural strategy to improve bacterial dispersion capacity and, consequently, to increase survival in stressed environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To report the magnetic resonance imaging (MRI) findings in athletic injuries of the extensor carpi ulnaris (ECU) subsheath, assessing the utility of gadolinium-enhanced (Gd) fat-saturated (FS) T1-weighted sequences with wrist pronation and supination. METHODS: Sixteen patients (13 male, three female; mean age 30.3 years) with athletic injuries of the ECU subsheath sustained between January 2003 and June 2009 were included in this retrospective study. Initial and follow-up 1.5-T wrist MRIs were performed with transverse T1-weighted and STIR sequences in pronation, and Gd FS T1-weighted sequences with wrist pronation and supination. Two radiologists assessed the type of injury (A to C), ECU tendon stability, associated lesions and rated pulse sequences using a three-point scale: 1=poor, 2=good and 3=excellent. RESULTS: Gd-enhanced FS T1-weighted transverse sequences in supination (2.63) and pronation (2.56) were most valuable, compared with STIR (2.19) and T1-weighted (1.94). Nine type A, one type B and six type C injuries were found. There were trends towards diminution in size, signal intensity and enhancement of associated pouches on follow-up MRI and tendon stabilisation within the ulnar groove. CONCLUSION: Gd-enhanced FS T1-weighted sequences with wrist pronation and supination are most valuable in assessing and follow-up athletic injuries of the ECU subsheath on 1.5-T MRI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Enhanced Recovery After Surgery (ERAS) clinical pathways in¦colorectal surgery are known to reduce postoperative complications leading¦to shortened hospital stay. However, the implementation of such an ERAS¦pathway requires time and financial investment. This study evaluates whether¦the savings related to the reduction in the length of stay (LOS) outweigh the¦costs of implementing an ERAS pathway.¦Methods: An ERAS pathway was implemented in our institution for colorectal¦surgery. The first 50 consecutive patients subjected to this ERAS pathway¦(ERAS group) were compared to 50 consecutive patients that were operated one¦year before its introduction (control group). Primary LOS, readmission within¦30 days, and total costs based on costs per day were compared. The mean costs¦per day were: 3,263 CHF for intensive care, 1,152 CHF for intermediate care,¦and 728 CHF for basic care.¦Results: Primary LOS was shorter in the ERAS group than in the control¦group: median 7 (interquartile range 5-12·25) versus 10 (7-18) days (P =¦0·0025). The readmission within 30 postoperative days was similar in both¦groups (2 patients each). In the ERAS group, the added primary LOS was¦485 days (379 in basic care, 99 in intermediate care, 7 in intensive care) compared¦to 706 days in the control group (533 in basic care, 146 in intermediate care,¦27 in intensive care). The total costs were significantly lower for the 50 ERAS¦patients compared to the control group: 412,801 CHF versus 644,317 CHF (P <¦0·01). Investments required for the 50 first ERAS patients were approximately¦83,544 CHF, including 348 working hours as well a full-time ERAS dedicated¦nurse. The overall cost saving was approximately 2,959 CHF per patient.¦Conclusion: Implementation of an ERAS pathway significantly reduced LOS¦after colorectal surgery. The financial investment to introduce and maintain¦such a pathway is clearly inferior to the cost-saving of reduced hospital stay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total disc replacement (TDR) clinical success has been reported to be related to the residual motion of the operated level. Thus, accurate measurement of TDR range of motion (ROM) is of utmost importance. One commonly used tool in measuring ROM is the Oxford Cobbometer. Little is known however on its accuracy (precision and bias) in measuring TDR angles. The aim of this study was to assess the ability of the Cobbometer to accurately measure radiographic TDR angles. An anatomically accurate synthetic L4-L5 motion segment was instrumented with a CHARITE artificial disc. The TDR angle and anatomical position between L4 and L5 was fixed to prohibit motion while the motion segment was radiographically imaged in various degrees of rotation and elevation, representing a sample of possible patient placement positions. An experienced observer made ten readings of the TDR angle using the Cobbometer at each different position. The Cobbometer readings were analyzed to determine measurement accuracy at each position. Furthermore, analysis of variance was used to study rotation and elevation of the motion segment as treatment factors. Cobbometer TDR angle measurements were most accurate (highest precision and lowest bias) at the centered position (95.5%), which placed the TDR directly inline with the x-ray beam source without any rotation. In contrast, the lowest accuracy (75.2%) was observed in the most rotated and off-centered view. A difference as high as 4 degrees between readings at any individual position, and as high as 6 degrees between all the positions was observed. Furthermore, the Cobbometer was unable to detect the expected trend in TDR angle projection with changing position. Although the Cobbometer has been reported to be reliable in different clinical applications, it lacks the needed accuracy to measure TDR angles and ROM. More accurate ROM measurement methods need to be developed to help surgeons and researchers assess radiological success of TDRs.