924 resultados para Axial compression


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (alpha = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study used 12 photoelastics models with different height and thickness to evaluate if the axial loading of 100N on implants changes the morphology of the photoelastic reflection. Methods: For the photoelastic analysis, the models were placed in a reflection polariscope for observation of the isochromatic fringes patterns. The formation of these fringes resulted from an axial load of 100N applied to the midpoint of the healing abutment attached to the implant with 10.0mm x 3.75mm (Conexão, Sistemas de Próteses, Brazil). The tension in each photoelastic model was monitored, photographed and observed using the software Phothoshop 7.0. For qualitative analysis, the area under the implant apex was measured including the green band of the second order fringe of each model using the software Image Tool. After comparison of the areas, the performance generated by each specimen was defined regarding the axial loading. Results: There were alterations in area with different height and thickness of the photoelastic models. It was observed that the group III (30mm in height) presented the smallest area. Conclusion: There was variation in the size of the areas analyzed for different height and thickness of the models and the morphology of the replica may directly influence the result in researches with photoelastic models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The modulus of elasticity is an important property for the behavior analysis of concrete structures. This research evaluated the strain difference between concrete specimens with and without the application of laminate carbon fiber composites as well as the variation time, in months, of the axial strength compression and modulus of elasticity. Through the experimental results, it is concluded that increases in compressive strength and modulus of elasticity are more significant in the specimens without reinforcement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The centrifuge technique was used to investigate the influence of particle size, applied compression, and substrate material (stainless steel, glass, Teflon, and poly(vinyl chloride)) on particle-surface adhesion force. For this purpose, phosphatic rock (rho(p) = 3090 kg/m(3)) and manioc starch particles (rho(p) = 1480 kg/m(3)) were used as test particles. A microcentrifuge that reached a maximum rotation speed of 14 000 rpm and which contained specially designed centrifuge tubes was used in the adhesion force measurements. The curves showed that the adhesion force profile followed a normal log distribution. The adhesion force increased linearly with particle size and with the increase of each increment of compression force. The manioc starch particles presented greater adhesion forces than the phosphatic rock particles for all particle sizes studied. The glass substrate showed a higher adherence than the other materials, probably due to its smoother topographic surface roughness in relation to the other substrata.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the ability of orbital apex crowding volume measurements calculated with multidetector-computed tomography to detect dysthyroid optic neuropathy. METHODS: Ninety-three patients with Graves' orbitopathy were studied prospectively. All of the patients underwent a complete neuro-ophthalmic examination and computed tomography scanning. Volumetric measurements were calculated from axial and coronal contiguous sections using a dedicated workstation. Orbital fat and muscle volume were estimated on the basis of their attenuation values (in Hounsfield units) using measurements from the anterior orbital rim to the optic foramen. Two indexes of orbital muscle crowding were calculated: i) the volumetric crowding index, which is the ratio between soft tissue (mainly extraocular muscles) and orbital fat volume and is based on axial scans of the entire orbit; and ii) the volumetric orbital apex crowding index, which is the ratio between the extraocular muscles and orbital fat volume and is based on coronal scans of the orbital apex. Two groups of orbits (with and without dysthyroid optic neuropathy) were compared. RESULTS: One hundred and two orbits of 61 patients with Graves' orbitopathy met the inclusion criteria and were analyzed. Forty-one orbits were diagnosed with Graves' orbitopathy, and 61 orbits did not have optic neuropathy. The two groups of orbits differed significantly with regard to both of the volumetric indexes (p<0.001). Although both indexes had good discrimination ability, the volumetric orbital apex crowding index yielded the best results with 92% sensitivity, 86% specificity, 81%/94% positive/negative predictive value and 88% accuracy at a cutoff of 4.14. CONCLUSION: This study found that the orbital volumetric crowding index was a more effective predictor of dysthyroid optic neuropathy than previously described computed tomography indexes were.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper shows in detail the modelling of anisotropic polymeric foam under compression and tension loadings, including discussions on isotropic material models and the entire procedure to calibrate the parameters involved. First, specimens of poly(vinyl chloride) (PVC) foam were investigated through experimental analyses in order to understand the mechanical behavior of this anisotropic material. Then, isotropic material models available in the commercial software Abaqus (TM) were investigated in order to verify their ability to model anisotropic foams and how the parameters involved can influence the results. Due to anisotropy, it is possible to obtain different values for the same parameter in the calibration process. The obtained set of parameters are used to calibrate the model according to the application of the structure. The models investigated showed minor and major limitations to simulate the mechanical behavior of anisotropic PVC foams under compression, tension and multi-axial loadings. Results show that the calibration process and the choice of the material model applied to the polymeric foam can provide good quantitative results and save project time. Results also indicate what kind and order of error one will get if certain choices are made throughout the modelling process. Finally, even though the developed calibration procedure is applied to specific PVC foam, it still outlines a very broad drill to analyze other anisotropic cellular materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Chyle fistulas may occur after left neck dissections that include level IV, due to injury of the thoracic duct or of 1 of its major branches. Despite being unusual, this complication carries substantial postoperative morbidity and even mortality. So far, no effective intraoperative maneuver has been reported to detect this fistula at the end of a neck dissection. In this cohort study, we sought to describe a simple new maneuver, intraoperative abdominal compression, which can effectively help to identify an open major lymphatic duct on level IV at the end of a neck dissection. Patients and Methods From March 1989 to September 2010, 206 patients underwent neck dissections involving left level IV, and underwent intraoperative abdominal compression. There were 119 men and 87 women, with ages ranging from 18 to 81 years (median, 52 years). One hundred forty-four patients had squamous cell carcinomas, 54 had thyroid carcinomas, 5 had malignant melanomas, and 3 had salivary cancers. Distribution by type of left neck dissection was: selective including levels II, III, and IV (73 cases; 35.4%), selective including levels II, III, IV, and V (55 cases; 26.6%), selective including levels I, II, III, and IV (12 cases; 5.8%), modified radical (47 cases; 22.8%), and radical (19 cases; 9.2%). In all cases, at the end of the procedure, the endotracheal tube was temporarily disconnected from the ventilator. Keeping the dissected level IV area under clear visualization, an abdominal compression was performed. At this moment, any detected lymphatic leak was carefully clamped and tied with nonabsorbable sutures. After ventilating the patient, the intraoperative abdominal compression was repeated to reassure complete occlusion of the lymphatic vessel. Results In 13 cases (6.3%), a chyle leak was detected after performing the intraoperative abdominal compression. All leaks except for 2 were successfully controlled after 1 attempt. In these 2 patients, a patch of muscle and fat tissue was applied with fibrin glue on the top. In 1 of these patients, another chyle leak in a different location was detected only at the second intraoperative abdominal compression, and was also effectively closed. Postoperatively, there were 2 (1%) chyle fistulas, both among these 13 cases, and all were successfully managed with clinical measures only. No fistulas occurred among the remaining 193 patients in whom intraoperative abdominal compression did not demonstrate lymphatic leak. Conclusion To our knowledge, this is the first description of a specific maneuver to actively detect a lymphatic fistula at the end of a left neck dissection involving level IV. In this study, intraoperative abdominal compression was able to detect an open lymphatic vessel in 6.3% of the cases, as well as to assure its effective sealing in the remaining 93.7% of the patients. Moreover, no life-threatening high-volume fistula was noted in this study. (C) 2012 Wiley Periodicals, Inc. Head Neck, 2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Field experiments have demonstrated that piles driven into sand can respond to axial cyclic loading in Stable, Unstable or Meta-Stable ways, depending on the combinations of mean and cyclic loads and the number of cycles. An understanding of the three styles of responses is provided by experiments involving a highly instrumented model displacement pile and an array of soil stress sensors installed in fine sand in a pressurised calibration chamber. The different patterns of effective stress developing on and around the shaft are reported, along with the results of static load tests that track the effects on shaft capacity. The interpretation links these observations to the sand's stress strain behaviour. The interface-shear characteristics, the kinematic yielding, the local densification, the growth of a fractured interface-shear zone and the restrained dilatancy at the pile soil interface are all found to be important. The model tests are shown to be compatible with the full-scale behaviour and to provide key information for improving the modelling and the design rules. (C) 2012 The Japanese Geotechnical Society. Production and hosting by Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During orthodontic tooth movement (OTM), alveolar bone is resorbed by osteoclasts in compression sites (CS) and is deposited by osteoblasts in tension sites (TS). The aim of this study was to develop a standardized OTM protocol in mice and to investigate the expression of bone resorption and deposition markers in CS and TS. An orthodontic appliance was placed in C57BL6/J mice. To define the ideal orthodontic force, the molars of the mice were subjected to forces of 0.1 N, 0.25 N, 0.35 N and 0.5 N. The expression of mediators that are involved in bone remodeling at CS and TS was analyzed using a Real-Time PCR. The data revealed that a force of 0.35 N promoted optimal OTM and osteoclast recruitment without root resorption. The levels of TNF-alpha, RANKL, MMP13 and OPG were all altered in CS and TS. Whereas TNF-a and Cathepsin K exhibited elevated levels in CS. RUNX2 and OCN levels were higher in TS. Our results suggest that 0.35 N is the ideal force for OTM in mice and has no side effects. Moreover, the expression of bone remodeling markers differed between the compression and the tension areas, potentially explaining the distinct cellular migration and differentiation patterns in each of these sites. (C) 2012 Elsevier Ltd. All rights reserved.