888 resultados para Automatic call detector


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper deals with the development and application of the methodology for automatic mapping of pollution/contamination data. General Regression Neural Network (GRNN) is considered in detail and is proposed as an efficient tool to solve this problem. The automatic tuning of isotropic and an anisotropic GRNN model using cross-validation procedure is presented. Results are compared with k-nearest-neighbours interpolation algorithm using independent validation data set. Quality of mapping is controlled by the analysis of raw data and the residuals using variography. Maps of probabilities of exceeding a given decision level and ?thick? isoline visualization of the uncertainties are presented as examples of decision-oriented mapping. Real case study is based on mapping of radioactively contaminated territories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän työn tarkoituksena oli tutkia pihkanhallintaa sulfaattisellutehtaalla ja uuteaineiden analysointimenetelmiä massasta ja suodoksesta. Tavoitteena oli kehittää uuteaineiden on-line mittausmenetelmä sulfaattisellutehtaalle. Kirjallisuusosassa esitettiin sulfaattisellun valmistusprosessi ja uuteaineiden käyttäytyminen prosessissa. Lisäksi työssä käsiteltiin tärkeimpiä pihkanhallintamenetelmiä ja uuteaineiden analysointia. Kokeellisessa osassa määritettiin uuteainepitoisuudet 29:stä massa- ja pesusuodosnäytteestä. Lisäksi suodosnäytteiden sameus ja kemiallinen hapenkulutus määritettiin laboratoriossa. On-line mittaukset tehtiin DD-pesurin paluusuodoksesta, josta mitattiin johtokyky, lämpötila, taitekerroin ja pH. Sameutta yritettiin mitata on-line nefelometrillä, mutta käytössä ollut laite ei soveltunut tumman suodoksen mittaamiseen. Työssä saatujen tulosten perusteella voidaan todeta, että pesusuodoksen ominaisuuksia mittaamalla ei voida arvioida massan uutepitoisuutta luotettavasti. Suodoksen ja massan uutepitoisuuksien välinen selitysaste oli 54%. Saippuoitumattomien uuteaineiden pitoisuuden ollessa erityisen suuri, suodoksen uutepitoisuus ei korreloi massassa olevan uutteen määrän kanssa. Täten kyseinen mittausmenetelmä ei ole sopiva, sillä se ei toimi silloin, kun olisi tärkeintä tietää oikea uuteainepitoisuus pihkanhallintakemikaalien annosten määrittämiseksi. Suodoksen sameus riippui sen uutepitoisuudesta 80% selitysasteella. Sameusmittaus on nopea ja suhteellisen luotettava menetelmä suodosten uutepitoisuuksien arviointiin, mutta se vaatii mittalaitteen joka käyttää usean ilmaisimen tekniikkaa. On-line-mittauksissa laitteisto tulisi varustaa automaattisella pesulaitteella, sillä mittarin linssit likaantuvat helposti prosessivirrassa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CERNin tutkimuskeskuksen rakenteilla olevan hadronikiihdyttimen eräs tarkoitus on todistaa Higgsin bosonin olemassaolo. Higgsin bosonin löytyminen yhtenäistäisi nykyisen hiukkasfysiikan teorian ja antaisi selityksen sille kuinka hiukkaset saavat massansa. Kiihdyttimen CMS koeasema on tarkoitettu erityisesti myonien ilmaisuun. Tämä työ liittyy CMS koeaseman RPC-ilmaisintyypin linkkijärjestelmään, jonka tarkoituksena on käsitellä ilmaisimelta tulevia myonien aiheuttamia signaaleja ja lähettää tiedot tärkeäksi katsotuista törmäystapahtumista tallennettavaksi analysointia varten. Työssä on toteutettu linkkijärjestelmän ohjaus- ja linkkikorteille testiympäristö, jolla voidaan todeta järjestelmän eri osien keskinäinen yhteensopivuus ja toimivuus. Työn alkuosassa esitellään ilmaisimen linkkijärjestelmän eri osat ja niiden merkitykset. Työn loppuosassa käydään läpi eri testimenetelmiä ja analysoidaan niiden antamia tuloksia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Euroopan hiukkastutkimuslaitoksen CERNin rakenteilla olevan LHC-hiukkaskiihdyttimen CMS-koeasema on tarkoitettu erityisesti myonin ilmaisuun. Tässä työssä on esitelty CMS-koeaseman RPC-ilmaisintyypin linkkijärjestelmä ja sen testaamiseen tarkoitetut laitteet sekä laitteiden testaamiseen tarvittavat ohjelmistot. Työssä on selvitetty ohjelmien toimivuus ja keskinäinen yhteensopivuus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent years have been characterized by a series of publications in the field of firearms investigation questioning the reliability and objectivity of such examination. This research investigates new solutions to decrease the subjective component affecting the evaluation that follows the comparison of impressions left by a firearm on the surface of spent cartridge cases. An automatic comparison system based on 3D measurements has been developed and coupled to a bivariate evaluative model allowing assigning likelihood ratios. Based on a dataset of 79 pistols (all SIG Sauer 9 mm Luger caliber), the system shows a very high discriminating power and the LRs that it provides are very indicative of the true state under both the prosecution and the defense propositions. For example, likelihood ratios exceeding a billion are predominantly obtained when impressions originating from the same source are compared. The system is also characterized by relatively low rates (≤1%) of misleading evidence depending on the firearm considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: This special commentary addresses recent clinical reviews regarding appropriate nutrition and metabolic support in the critical care setting. RECENT FINDINGS: There are divergent approaches between North America and Europe for the use of early nutrition support and combined enteral nutrition and parenteral nutrition support possibly due to the commercial availability of specific parenteral nutrients. The advent of intensive insulin therapy has changed the landscape of metabolic support in the intensive care unit, and previous notions about infective risk of parenteral nutrition will need to be re-addressed. Patients with brain failure may benefit from an intensive insulin therapy with a blood glucose target that is higher than that used in patients without brain failure. Patients with heart failure may benefit from the addition of nutritional pharmacology that targets proximate oxidative pathophysiological pathways. Intradialytic parenteral nutrition may be viewed as another form of supplemental parenteral nutrition when enteral nutrition is insufficient in patients on hemodialysis in the intensive care unit. SUMMARY: It is proposed that intensive metabolic support be routinely implemented in the intensive care unit based on the following steps: intensive insulin therapy with an appropriate blood glucose target, nutrition risk assessment, early and if needed combined enteral nutrition and parenteral nutrition to target 20-25 kcal/kg/day and 1.2-1.5 g protein/kg/day, and nutritional and metabolic monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the sensor of an optical mouse is presented as a counterfeit coin detector applied to the two-Euro case. The detection process is based on the short distance image acquisition capabilities of the optical mouse sensor where partial images of the coin under analysis are compared with some partial reference coin images for matching. Results show that, using only the vision sense, the counterfeit acceptance and rejection rates are very similar to those of a trained user and better than those of an untrained user.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Chronic kidney disease (CKD) accelerates vascular stiffening related to age. Arterial stiffness may be evaluated measuring the carotid-femoral pulse wave velocity (PWV) or more simply, as recommended by KDOQI, monitoring pulse pressure (PP). Both correlate to survival and incidence of cardiovascular disease. PWV can also be estimated on the brachial artery using a Mobil-O-Graph; a non-operator dependent automatic device. The aim was to analyse whether, in a dialysis population, PWV obtained by Mobil-O-Graph (MogPWV) is more sensitive for vascular aging than PP. METHODS: A cohort of 143 patients from 4 dialysis units has been followed measuring MogPWV and PP every 3 to 6 months and compared to a control group with the same risk factors but an eGFR > 30 ml/min. RESULTS: MogPWV contrarily to PP did discriminate the dialysis population from the control group. The mean difference translated in age between the two populations was 8.4 years. The increase in MogPWV, as a function of age, was more rapid in the dialysis group. 13.3% of the dialysis patients but only 3.0% of the control group were outliers for MogPWV. The mortality rate (16 out of 143) was similar in outliers and inliers (7.4 and 8.0%/year). Stratifying patients according to MogPWV, a significant difference in survival was seen. A high parathormone (PTH) and to be dialysed for a hypertensive nephropathy were associated to a higher baseline MogPWV. CONCLUSIONS: Assessing PWV on the brachial artery using a Mobil-O-Graph is a valid and simple alternative, which, in the dialysis population, is more sensitive for vascular aging than PP. As demonstrated in previous studies PWV correlates to mortality. Among specific CKD risk factors only PTH is associated with a higher baseline PWV. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02327962.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Target identification for tractography studies requires solid anatomical knowledge validated by an extensive literature review across species for each seed structure to be studied. Manual literature review to identify targets for a given seed region is tedious and potentially subjective. Therefore, complementary approaches would be useful. We propose to use text-mining models to automatically suggest potential targets from the neuroscientific literature, full-text articles and abstracts, so that they can be used for anatomical connection studies and more specifically for tractography. We applied text-mining models to three structures: two well-studied structures, since validated deep brain stimulation targets, the internal globus pallidus and the subthalamic nucleus and, the nucleus accumbens, an exploratory target for treating psychiatric disorders. We performed a systematic review of the literature to document the projections of the three selected structures and compared it with the targets proposed by text-mining models, both in rat and primate (including human). We ran probabilistic tractography on the nucleus accumbens and compared the output with the results of the text-mining models and literature review. Overall, text-mining the literature could find three times as many targets as two man-weeks of curation could. The overall efficiency of the text-mining against literature review in our study was 98% recall (at 36% precision), meaning that over all the targets for the three selected seeds, only one target has been missed by text-mining. We demonstrate that connectivity for a structure of interest can be extracted from a very large amount of publications and abstracts. We believe this tool will be useful in helping the neuroscience community to facilitate connectivity studies of particular brain regions. The text mining tools used for the study are part of the HBP Neuroinformatics Platform, publicly available at http://connectivity-brainer.rhcloud.com/.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Proper delineation of ocular anatomy in 3-dimensional (3D) imaging is a big challenge, particularly when developing treatment plans for ocular diseases. Magnetic resonance imaging (MRI) is presently used in clinical practice for diagnosis confirmation and treatment planning for treatment of retinoblastoma in infants, where it serves as a source of information, complementary to the fundus or ultrasonographic imaging. Here we present a framework to fully automatically segment the eye anatomy for MRI based on 3D active shape models (ASM), and we validate the results and present a proof of concept to automatically segment pathological eyes. METHODS AND MATERIALS: Manual and automatic segmentation were performed in 24 images of healthy children's eyes (3.29 ± 2.15 years of age). Imaging was performed using a 3-T MRI scanner. The ASM consists of the lens, the vitreous humor, the sclera, and the cornea. The model was fitted by first automatically detecting the position of the eye center, the lens, and the optic nerve, and then aligning the model and fitting it to the patient. We validated our segmentation method by using a leave-one-out cross-validation. The segmentation results were evaluated by measuring the overlap, using the Dice similarity coefficient (DSC) and the mean distance error. RESULTS: We obtained a DSC of 94.90 ± 2.12% for the sclera and the cornea, 94.72 ± 1.89% for the vitreous humor, and 85.16 ± 4.91% for the lens. The mean distance error was 0.26 ± 0.09 mm. The entire process took 14 seconds on average per eye. CONCLUSION: We provide a reliable and accurate tool that enables clinicians to automatically segment the sclera, the cornea, the vitreous humor, and the lens, using MRI. We additionally present a proof of concept for fully automatically segmenting eye pathology. This tool reduces the time needed for eye shape delineation and thus can help clinicians when planning eye treatment and confirming the extent of the tumor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we design and develop several filtering strategies for the analysis of data generated by a resonant bar gravitational wave (GW) antenna, with the goal of assessing the presence (or absence) therein of long-duration monochromatic GW signals, as well as the eventual amplitude and frequency of the signals, within the sensitivity band of the detector. Such signals are most likely generated in the fast rotation of slightly asymmetric spinning stars. We develop practical procedures, together with a study of their statistical properties, which will provide us with useful information on the performance of each technique. The selection of candidate events will then be established according to threshold-crossing probabilities, based on the Neyman-Pearson criterion. In particular, it will be shown that our approach, based on phase estimation, presents a better signal-to-noise ratio than does pure spectral analysis, the most common approach.