851 resultados para Adverse Drug Reaction Reporting Systems


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The nonlinear dynamics of certain important reaction systems are discussed and analysed in this thesis. The interest in the theoretical and the experimental studies of chemical reactions showing oscillatory dynamics and associated properties is increasing very rapidly. An attempt is made to study some nonlinear phenomena exhibited by the well known chemical oscillator, the BelousovZhabotinskii reaction whose mathematical properties are much in common with the properties of biological oscillators. While extremely complex, this reaction is still much simpler than biological systems at least from the modelling point of view. A suitable model [19] for the system is analysed and the researcher has studied the limit cycle behaviour of the system, for different values of the stoichiometric parameter f, by keeping the value of the reaction rate (k6) fixed at k6 = l. The more complicated three-variable model is stiff in nature.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The overall immunopathogenesis relevant to a large series of disorders caused by a drug or its associated hyperimmune condition is discussed based upon the examination of the genetics of severe drug-induced bullous skin problems (sporadic idiosyncratic adverse events, including Stevens-Johnson syndrome and toxic epidermal necrolysis). An overarching pharmacogenetic schema is proposed. Immune cognition and early-effector processes are focused upon and a challenging synthesis around systems evolution is explained by a variety of projective analogies. Etiology, human leukocyte antigen-B, immune stability, clysiregulation, pharmacomimicry, viruses and an aggressive ethnically differentiated 'karmic' response are discussed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mucosa-mimetic polymeric hydrogels have been developed to replace the use of animal tissues as substrates for characterising mucoadhesive properties of drug delivery systems.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

When ε-nitro-a,β-unsaturated esters are added to conjugated cyanosulfones in the presence of a bifunctional thiourea catalyst, a highly stereoselective domino reaction occurs to generate complex cyclohexanes with up to four stereogenic centers, one of which is quaternary in nature. Therefore, it is demonstrated that, like nitro compounds, sulfones can undergo an asymmetric intramolecular conjugate addition to r,β- unsaturated esters in the presence of a bifunctional organocatalyst.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Thiol-bearing microgels have been synthesised from copolymerisation of 2-(acetylthio)ethylacrylate and 2-hydroxyethylmethacrylate, and subsequent deprotection using sodium thiomethoxide. The concentration of thiol groups on these microgels could be tailored by use of different molar ratios of the two monomers. These thiol-bearing microgels were shown to adhere to ex vivo porcine urinary bladder, which was correlated with their level of thiolation. By simply mixing solutions of thiol-bearing microgels and doxorubicin, high levels of drug loading into the microgels could be achieved. Thiol-bearing microgels controlled the release of doxorubicin in a time-dependent manner over several hours. These doxorubicin-loaded thiol-bearing microgels could have application in the treatment of early-stage bladder cancers. The method used represents a new ‘bottom-up’ approach for the synthesis of novel mucoadhesive microgels.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study evaluated the use of Pluronic F127 and Pluronic F68 as excipients for formulating in situ gelling systems for ocular drug delivery. Thermal transitions have been studied in aqueous solutions of Pluronic F127, Pluronic F68 as well as their binary mixtures using differential scanning calorimetry, rheological measurements, and dynamic light scattering. It was established that the formation of transparent gels at physiologically relevant temperatures is observed only in the case of 20 wt % of Pluronic F127. The addition of Pluronic F68 to Pluronic F127 solutions increases the gelation temperature of binary formulation to above physiological range of temperatures. The biocompatibility evaluation of these formulations using slug mucosa irritation assay and bovine corneal erosion studies revealed that these polymers and their combinations do not cause significant irritation. In vitro drug retention study on glass surfaces and freshly excised bovine cornea showed superior performance of 20 wt % Pluronic F127 compared to other formulations. In addition, in vivo studies in rabbits demonstrated better retention performance of 20 wt % Pluronic F127 compared to Pluronic F68. These results confirmed that 20 wt % Pluronic F127 offers an attractive ocular formulation that can form a transparent gel in situ under physiological conditions with minimal irritation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We estimated the sensitivity, i.e., the proportion of all cases of adverse events following immunization (AEFIs) reported to the Brazilian passive surveillance for adverse events following immunization (PSAEFI) with the diphtheria-tetanus-whole-cell pertussis-Haemophilus influenzae type b (DTwP/Hib) vaccine, as well as investigating factors associated with AEFIs reporting. During 2003-2004, 8303 AEFIs associated with DTwP-Hib were reported; hypotonic-hyporesponsive episodes (HHEs), fever and convulsions being the most common. Cure without sequel was achieved in 98.4% of the cases. The mean sensitivity of the PSAEFI was 22.3% and 31.6%, respectively, for HHE and convulsions, varying widely among states. Reporting rates correlated positively with the Human Development Index and coverage of adequate prenatal care, correlating negatively with infant mortality rates. Quality of life indicators and the degree of organization of health services are associated with greater PSAEFI sensitivity. In addition to consistently describing the principal AEFIs, PSAEFI showed the DTwP/Hib vaccine to be safe and allayed public fears related to its use. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We use a new technique to investigate the systematic behavior of near barrier complete fusion, total fusion and total reaction cross sections of weakly bound systems. A dimensionless fusion excitation function is used as a benchmark to which renormalized fusion data are compared and dynamic breakup effects can be disentangled from static effects. The same reduction procedure is used to study the effect of the direct reaction mechanisms on the total reaction cross section.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We propose a new technique to analyze total reaction cross sections. In this technique, which has been previously applied to fusion reactions, the experimental data are used to build a dimensionless reaction function, which does not depend oil the system size or details of the optical potential. In this way, total reaction cross sections for different systems can be directly compared. We employ this technique to perform a systematic study of reaction cross sections of weakly bound systems in different mass ranges, and compare their reaction functions with the ones of tightly bound systems with similar masses. We show that breakup reactions and neutron transfers in halo systems lead to large reaction functions, well above the ones of typical tightly or weakly bound stable systems. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We have measured the elastic scattering cross-section for (8)Li + (9)Be and (8)Li + (51)V systems at 19.6 MeV and 18.5 MeV, respectively. We have also extracted total reaction cross sections from the elastic scattering analysis for several light weakly bound systems using the optical model with Woods-Saxon and double-folding-type potentials. Different reduction methods for the total reaction cross-sections have been applied to analyze and compare simultaneously all the systems.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

COSTA MIGUEL, M. C.; NONAKA, C. F. W.; GERMANO, A. R.; SOUZA, L. B.; SOUZA, L. B. Oral foreign body granuloma: unusual presentation of a rare adverse reaction to permanent injectable cosmetic filler. International journal of oral and maxillofacial surgery, v. 38, p. 385-387, 2009.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Drug delivery systems are essential components of drugs controlled release. In the last decades, several drug delivery technologies have emerged including capsules, liposomes. microparticles, nanoparticles, and polymers. These components must be biocompatible, biodegradable, and display a desired biodistribution providing a long-term availability of the therapeutic at specific target over time.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)