852 resultados para Advanced Mercury Analyser AMA-254, LECO
Resumo:
Real time glycemia is a cornerstone for metabolic research, particularly when performing oral glucose tolerance tests (OGTT) or glucose clamps. From 1965 to 2009, the gold standard device for real time plasma glucose assessment was the Beckman glucose analyzer 2 (Beckman Instruments, Fullerton, CA), which technology couples glucose oxidase enzymatic assay with oxygen sensors. Since its discontinuation in 2009, today's researchers are left with few choices that utilize glucose oxidase technology. The first one is the YSI 2300 (Yellow Springs Instruments Corp., Yellow Springs, OH), known to be as accurate as the Beckman(1). The YSI has been used extensively for clinical research studies and is used to validate other glucose monitoring devices(2). The major drawback of the YSI is that it is relatively slow and requires high maintenance. The Analox GM9 (Analox instruments, London), more recent and faster, is increasingly used in clinical research(3) as well as in basic sciences(4) (e.g. 23 papers in Diabetes or 21 in Diabetologia). This article is protected by copyright. All rights reserved.
Resumo:
This documents sums up a projectaimed at building a new web interfaceto the Apertium machine translationplatform, including pre-editing andpost-editing environments. It containsa description of the accomplished workon this project, as well as an overviewof possible evolutions.
Resumo:
Granular flow phenomena are frequently encountered in the design of process and industrial plants in the traditional fields of the chemical, nuclear and oil industries as well as in other activities such as food and materials handling. Multi-phase flow is one important branch of the granular flow. Granular materials have unusual kinds of behavior compared to normal materials, either solids or fluids. Although some of the characteristics are still not well-known yet, one thing is confirmed: the particle-particle interaction plays a key role in the dynamics of granular materials, especially for dense granular materials. At the beginning of this thesis, detailed illustration of developing two models for describing the interaction based on the results of finite-element simulation, dimension analysis and numerical simulation is presented. The first model is used to describing the normal collision of viscoelastic particles. Based on some existent models, more parameters are added to this model, which make the model predict the experimental results more accurately. The second model is used for oblique collision, which include the effects from tangential velocity, angular velocity and surface friction based on Coulomb's law. The theoretical predictions of this model are in agreement with those by finite-element simulation. I n the latter chapters of this thesis, the models are used to predict industrial granular flow and the agreement between the simulations and experiments also shows the validation of the new model. The first case presents the simulation of granular flow passing over a circular obstacle. The simulations successfully predict the existence of a parabolic steady layer and show how the characteristics of the particles, such as coefficients of restitution and surface friction affect the separation results. The second case is a spinning container filled with granular material. Employing the previous models, the simulation could also reproduce experimentally observed phenomena, such as a depression in the center of a high frequency rotation. The third application is about gas-solid mixed flow in a vertically vibrated device. Gas phase motion is added to coherence with the particle motion. The governing equations of the gas phase are solved by using the Large eddy simulation (LES) and particle motion is predicted by using the Lagrangian method. The simulation predicted some pattern formation reported by experiment.
Resumo:
Diplomityön tavoitteena oli tarkastella numeerisen virtauslaskennan avulla virtaukseen liittyviä ilmiöitä ja kaasun dispersiota. Diplomityön sisältö on jaettu viiteen osaan; johdantoon, teoriaan, katsaukseen virtauksen mallinnukseen huokoisessa materiaalissa liittyviin tutkimusselvityksiin, numeeriseen mallinnukseen sekä tulosten esittämiseen ja johtopäätöksiin. Diplomityön alussa kiinnitettiin huomiota erilaisiin kokeellisiin, numeerisiin ja teoreettisiin mallinnusmenetelmiin, joilla voidaan mallintaa virtausta huokoisessa materiaalissa. Kirjallisuusosassa tehtiin katsaus aikaisemmin julkaistuihin puoliempiirisiin ja empiirisiin tutkimusselvityksiin, jotka liittyvät huokoisen materiaalin aiheuttamaan painehäviöön. Numeerisessa virtauslaskenta osassa rakennettiin ja esitettiin huokoista materiaalia kuvaavat numeeriset mallit käyttäen kaupallista FLUENT -ohjelmistoa. Työn lopussa arvioitiin teorian, numeerisen virtauslaskennan ja kokeellisten tutkimusselvitysten tuloksia. Kolmiulotteisen huokoisen materiaalinnumeerisessa mallinnuksesta saadut tulokset vaikuttivat lupaavilta. Näiden tulosten perusteella tehtiin suosituksia ajatellen tulevaa virtauksen mallinnusta huokoisessa materiaalissa. Osa tässä diplomityössä esitetyistä tuloksista tullaan esittämään 55. Kanadan Kemiantekniikan konferenssissa Torontossa 1619 Lokakuussa 2005. ASME :n kansainvälisessä tekniikan alan julkaisussa. Työ on hyväksytty esitettäväksi esitettäväksi laskennallisen virtausmekaniikan (CFD) aihealueessa 'Peruskäsitteet'. Lisäksi työn yksityiskohtaiset tulokset tullaan lähettämään myös CES:n julkaisuun.
Resumo:
Résumé La levodopa (LD) est le traitement antiparkinsonien le plus efficace et le plus répandu. Son effet est composé d'une réponse de courte (quelques heures) et de longue durée (jours à semaines). La persistance de cette dernière dans les phases avancées de la maladie de Parkinson est controversée, et sa mesure directe n'a jamais été faite en raison des risques liés à un sevrage complet de LD. La stimulation du noyau sous-thalamique est un nouveau traitement neurochirurgical de la maladie de Parkinson, indiqué dans les formes avancées, qui permet l'arrêt complet du traitement médicamenteux chez certains patients. Nous avons étudié 30 patients qui ont bénéficié d'une telle stimulation, et les avons évalués avant l'intervention sans médicaments, et à 6 mois postopératoires, sans médicaments et sans stimulation. Chez 19 patients, la médication a pu être complètement arrêtée, alors qu'elle a dû être réintroduite chez les 11 patients restants. Au cours des 6 mois qui ont suivi l'intervention, le parkinsonisme s'est aggravé de façon significative dans le groupe sans LD, et non dans le groupe avec LD. Cette différence d'évolution s'explique par la perte de l'effet à long terme de la LD dans le groupe chez qui ce médicament a pu être arrêté. En comparant cette aggravation à la magnitude de l'effet à court terme, la réponse de longue durée correspond environ à 80 pourcent de la réponse de courte durée, et elle lui est inversement corrélée. Parmi les signes cardinaux de la maladie, la réponse de longue durée affecte surtout la bradycinésie et la rigidité, mais pas le tremblement ni la composante axiale. La comparaison du parkinsonisme avec traitement (stimulation et LD si applicable) ne montre aucune différence d'évolution entre les 2 groupes, suggérant que la stimulation compense tant la réponse de courte que de longue durée. Notre travail montre que la réponse de longue durée à la LD demeure significative chez les patients parkinsoniens après plus de 15 ans d'évolution, et suggère que la stimulation du noyau sous-thalamique compense les réponses de courte et de longue durée. Abstract Background: Long duration response to levodopa is supposed to decrease with Parkinson's disease (PD) progression, but direct observation of this response in advanced PD has never been performed. Objective: To study the long duration response to levodopa in advanced PD patients treated with subthalamic deep-brain stimulation. Design and settings: We studied 30 consecutive PD patients who underwent subthalamic deep-brain stimulation. One group had no antiparkinsonian treatment since surgery (no levodopa), while medical treatment had to be reinitiated in the other group (levodopa). Main outcome measures: motor Unified Parkinson's Disease Rating Scale (UPDRS). Results: In comparison with preoperative assessment, evaluation six months postoperatively with stimulation turned off for three hours found a worsening of the motor part of UPDRS in the no-levodopa group. This worsening being absent in the levodopa group, it most probably reflected the loss of the long duration response to levodopa in the no-levodopa group. Stimulation turned on, postoperative motor UPDRS in both groups were similar to preoperative on medication scores, suggesting that subthalamic deep-brain stimulation compensated for both the short and long duration responses to levodopa. Conclusions: Our results suggest that the long duration response to levodopa remains significant even in advanced PD, and that subthalamic deep-brain stimulation compensates for both the short and the long duration resposes to levodopa.
Resumo:
BACKGROUND: To evaluate feasibility and preliminary outcomes associated with sequential whole abdomen irradiation (WAI) as consolidative treatment following comprehensive surgery and systemic chemotherapy for advanced endometrial cancer. METHODS: We conducted a retrospective analysis of patients treated at our institution from 2000 to 2011. Inclusion criteria were stage III-IV endometrial cancer patients with histological proof of one or more sites of extra-uterine abdomen-confined disease, treated with WAI as part of multimodal therapy. Endpoints were feasibility, acute toxicity, late effects, recurrence-free survival (RFS) and overall survival (OS). Twenty patients were identified. Chemotherapy consisted of 3 to 6 cycles of a platinum-paclitaxel regimen in 18 patients. WAI was delivered using conventional technique to a median total dose of 27.5 Gy. RESULTS: No grade 4 toxicities occurred during chemotherapy or radiotherapy. No radiation dose reduction was necessary. Three patients developed small bowel obstruction, all in the context of recurrent intraperitoneal disease. Kaplan-Meier estimates and 95% confidence intervals for RFS and OS at one year were 63% (38-80%) and 83% (56-94%) and at 3 years 57% (33-76%) and 62% (34-81%), respectively. On univariate Cox analysis, stage IVB and serous papillary (SP) histology were found to be statistically significantly (at the p = 0.05 level) associated with worse RFS and OS. The peritoneal cavity was the most frequent site of initial failure. CONCLUSIONS: Consolidative WAI following chemotherapy is feasible and can be performed without interruption with manageable acute and late toxicity. Patients with endometrioid adenocarcinoma, especially stage FIGO III, had favorable outcomes possibly meriting prospective evaluation of the addition of WAI following chemotherapy in selected patients. Patients with SP do poorly and do not routinely benefit from this approach.
Resumo:
Introduction: Trastuzumab (T) is a cornerstone in the treatment of patients with HER2-overexpressing advanced breast cancer and development of resistance to T is a major therapeutic problem. HER-2 is part of a highly interactive signaling network that may impair efficacy of endocrine therapy. A sequential treatment design was chosen in this trial to ensure complete resistance to single agent therapy before receiving both a non-steroidal aromatase inhibitor (AI) and T. Any kind of clinical activity with combined treatment of AI and T after progression of single agent treatments could indicate restoration of sensitivity as a consequence of cross-talking and networking between both pathways. Methods: Key eligibility criteria included postmenopausal patients (pts.) with advanced, measurable, HER-2 positive (assessed by FISH, ratio (≥2)), HR positive disease and progression on prior treatment with a non-steroidal AI, e.g. letrozole or anastrozole, either in an adjuvant or advanced setting. Pts. received standard dose T monotherapy either weekly or three-weekly in step 1 and upon disease progression, continued T in combination with letrozole in step 2. The primary endpoint was clinical benefit response (CBR: CR, PR or SD for at least 24 weeks (+/- 1 week) according to RECIST) in step 2. Results: Thirteen pts. were enrolled in five centers in Switzerland. In step 1, six pts. (46%) achieved CBR. Median time to progression (TTP) was 161 days (Range: 50 - 627). Based on data collected until the end of May 2010, CBR was observed in seven out of the eleven evaluable pts. (64%) in step 2, including one pt. with partial response. Four of the seven pts. within step 2 that achieved CBR also had CBR in step 1. Seven out of eleven pts. have documented tumor progression during step 2 treatment. Median TTP for all eleven pts. was 184 days (range 61 - 471). Mean time on study treatment (TTP in step 1 plus TTP in step 2) for pts. reaching step 2 was 380 days (range 174 - 864). Adverse events were generally mild. Conclusion: Results of this proof-of-principle trial suggest that complete resistance to both AI and T can be overcome in a proportion of pts. by combined treatment of AI and T, as all pts. served as their own control. Our results appear promising for a new treatment strategy which offers a chemotherapy-free and well-tolerated option for at least a subset of the pts. with HR positive, HER-2 positive breast cancer. Further trials will need to corroborate this finding.
Resumo:
Nowadays typical motor junction boxes do not incorporate cable glands, which would provide good electrical performance interms of electromagnetic compatibility. In this paper, a manufacturability and assembly analysis for the new construction of a rigid body feeder cable junction of an electric motor is presented especially for converter drives (practical tests were carried out at LUT during 2007). Although the cable junction should also clamp the cable to provide enough tensile strength, the phase conductors should not get squashed by the groundingconnection. In order to ensure good performance in an electrical mean especially in converter drives, the grounding of the cable should be connected 360 degrees around the cable. In this paper, following manufacturing technologies are discussed: traditional turning, precision and centrifugal casting, and rotation moulding. DFM(A)-aspects are presented in detail.
Resumo:
This project proposes a preliminary architectural design for a control and data processing center, also known as 'ground segment', for Earth observation satellites.
Resumo:
BACKGROUND: Chronic kidney disease (CKD) accelerates vascular stiffening related to age. Arterial stiffness may be evaluated measuring the carotid-femoral pulse wave velocity (PWV) or more simply, as recommended by KDOQI, monitoring pulse pressure (PP). Both correlate to survival and incidence of cardiovascular disease. PWV can also be estimated on the brachial artery using a Mobil-O-Graph; a non-operator dependent automatic device. The aim was to analyse whether, in a dialysis population, PWV obtained by Mobil-O-Graph (MogPWV) is more sensitive for vascular aging than PP. METHODS: A cohort of 143 patients from 4 dialysis units has been followed measuring MogPWV and PP every 3 to 6 months and compared to a control group with the same risk factors but an eGFR > 30 ml/min. RESULTS: MogPWV contrarily to PP did discriminate the dialysis population from the control group. The mean difference translated in age between the two populations was 8.4 years. The increase in MogPWV, as a function of age, was more rapid in the dialysis group. 13.3% of the dialysis patients but only 3.0% of the control group were outliers for MogPWV. The mortality rate (16 out of 143) was similar in outliers and inliers (7.4 and 8.0%/year). Stratifying patients according to MogPWV, a significant difference in survival was seen. A high parathormone (PTH) and to be dialysed for a hypertensive nephropathy were associated to a higher baseline MogPWV. CONCLUSIONS: Assessing PWV on the brachial artery using a Mobil-O-Graph is a valid and simple alternative, which, in the dialysis population, is more sensitive for vascular aging than PP. As demonstrated in previous studies PWV correlates to mortality. Among specific CKD risk factors only PTH is associated with a higher baseline PWV. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02327962.
Resumo:
This thesis describes the development of advanced silicon radiation detectors and their characterization by simulations, used in the work for searching elementary particles in the European Organization for Nuclear Research, CERN. Silicon particle detectors will face extremely harsh radiation in the proposed upgrade of the Large Hadron Collider, the future high-energy physics experiment Super-LHC. The increase in the maximal fluence and the beam luminosity up to 1016 neq / cm2 and 1035 cm-2s-1 will require detectors with a dramatic improvement in radiation hardness, when such a fluence will be far beyond the operational limits of the present silicon detectors. The main goals of detector development concentrate on minimizing the radiation degradation. This study contributes mainly to the device engineering technology for developing more radiation hard particle detectors with better characteristics. Also the defect engineering technology is discussed. In the nearest region of the beam in Super-LHC, the only detector choice is 3D detectors, or alternatively replacing other types of detectors every two years. The interest in the 3D silicon detectors is continuously growing because of their many advantages as compared to conventional planar detectors: the devices can be fully depleted at low bias voltages, the speed of the charge collection is high, and the collection distances are about one order of magnitude less than those of planar technology strip and pixel detectors with electrodes limited to the detector surface. Also the 3D detectors exhibit high radiation tolerance, and thus the ability of the silicon detectors to operate after irradiation is increased. Two parameters, full depletion voltage and electric field distribution, is discussed in more detail in this study. The full depletion of the detector is important because the only depleted area in the detector is active for the particle tracking. Similarly, the high electric field in the detector makes the detector volume sensitive, while low-field areas are non-sensitive to particles. This study shows the simulation results of full depletion voltage and the electric field distribution for the various types of 3D detectors. First, the 3D detector with the n-type substrate and partial-penetrating p-type electrodes are researched. A detector of this type has a low electric field on the pixel side and it suffers from type inversion. Next, the substrate is changed to p-type and the detectors having electrodes with one doping type and the dual doping type are examined. The electric field profile in a dual-column 3D Si detector is more uniform than that in the single-type column 3D detector. The dual-column detectors are the best in radiation hardness because of their low depletion voltages and short drift distances.