945 resultados para Active power reserver for frequency control
Resumo:
The aim of the present study was to investigate the potential benefits of cold water immersion (CWI) and active recovery (AR) on blood lactate concentration ([Lac]) and heart rate variability (HRV) indices following high-intensity exercise. 20 male subjects were recruited. on the first visit, an incremental test was performed to determine maximal oxygen consumption and the associated speed (MAS). The remaining 3 visits for the performance of constant velocity exhaustive tests at MAS and different recovery methods (6 min) were separated by 7-day intervals [randomized: CWI, AR or passive recovery (PR)]. The CWI and AR lowered [Lac] (p < 0.05) at 11, 13 and 15 min after exercise cessation in comparison to PR. There was a 'time' and 'recovery mode' interaction for 2 HRV indices: standard deviation of normal R-R intervals (SDNN) (partial eta squared = 0.114) and natural log of low-frequency power density (lnLF) (partial eta squared = 0.090). CWI presented significantly higher SDNN compared to PR at 15 min of recovery (p < 0.05). In addition, greater SDNN values were found in CWI vs. AR during the application of recovery interventions, and at 30 and 75 min post-exercise (p < 0.05 for all differences). The lnLF during the recovery interventions and at 75 min post-exercise was greater using CWI compared with AR (p < 0.05). For square root of the mean of the sum of the squares of differences between adjacent R-R intervals (RMSSD) and natural log of high-frequency power density (lnHF), a moderate effect size was found between CWI and PR during the recovery interventions and at 15 min post-exercise. Our findings show that AR and CWI offer benefits regarding the removal of [Lac] following high-intensity exercise. While limited, CWI results in some improvement in post-exercise cardiac autonomic regulation compared to AR and PR. Further, AR is not recommended if the aim is to accelerate the parasympathetic reactivation.
Resumo:
This paper presents the analysis and the design of a peak-current-controlled high-power-factor boost rectifier, with slope compensation, operating at constant frequency. The input current shaping is achieved, with continuous inductor current mode, with no multiplier to generate a current reference. The resulting overall circuitry is very simple, in comparison with the average-current-controlled boost rectifier. Experimental results are presented, taken from a laboratory prototype rated at 370 W and operating at 67 kHz. The measured power factor was 0.99, with a input current THD equal to 5.6%, for an input voltage THD equal to 2.26%.
Resumo:
This paper investigates both theoretically and experimentally the effect of the location and number of sensors and magnetic bearing actuators on both global and local vibration reduction along a rotor using a feedforward control scheme. Theoretical approaches developed for the active control of beams have been shown to be useful as simplified models for the rotor scenario. This paper also introduces the time-domain LMS feedforward control strategy, used widely in the active control of sound and vibration, as an alternative control methodology to the frequency-domain feedforward approaches commonly presented in the literature. Results are presented showing that for any case where the same number of actuators and error sensors are used there can be frequencies at which large increases in vibration away from the error sensors can occur. It is also shown that using a larger number of error sensors than actuators results in better global reduction of vibration but decreased local reduction. Overall, the study demonstrated that an analysis of actuator and sensor locations when feedforward control schemes are used is necessary to ensure that harmful increased vibrations do not occur at frequencies away from rotor-bearing natural frequencies or at points along the rotor not monitored by error sensors.
Resumo:
The Brazilian Network for Continuous Monitoring of GPS - RBMC, since its foundation in December of 1996, has been playing an essential role for the maintenance and user access of the fundamental geodetic frame in the country,. It provides users with a direct link to the Brazilian Geodetic System - SGB. Its role has become more relevant with the increasing use of space navigation technology in the country. Recently, Brazil adopted a new geodetic system, SIRGAS2000, in February 2005, fully compatible with GNSS technology. The paper provides an overview of the recent modernization phases the RBMC network has undergone highlighting its future steps. From its current post-mission mode, the RBMC will evolve into a real-time network, providing real-time data and real-time correction to users. The network enhanced with modern GPS receivers and the addition of atomic clocks will be used to compute WADGPS-type corrections to be transmitted, in real time, to users in Brazil and surrounding areas. It is estimated that users will be able to achieve a horizontal accuracy around 0.5 m (1σ) in static and kinematic positioning and better for dual frequency users. The availability of the WADGPS service will allow users to tie to the new SIRGAS2000 system in a more rapid and transparent way for positioning and navigation applications. It should be emphasized that support to post-mission static positioning will continue to be provided to users interested in higher accuracy levels. In addition to this, a post-mission Precise Point Positioning (PPP) service will be provided based on the one currently provided by the Geodetic Survey Division of NRCan (CSRS-PPP). The modernization of the RBMC is under development based on a cooperation signed at the end of 2004 with the University of New Brunswick, supported by the Canadian International Development Agency and the Brazilian Cooperation Agency. The Geodetic Survey Division of NRCan is also participating in this modernization effort under the same project.
Resumo:
The Brazilian Network for Continuous Monitoring of GPS - RBMC, since its foundation in December of 1996, has been playing an essential role for the maintenance and user access of the fundamental geodetic frame in the country. It provides to users a direct link to the Brazilian Geodetic System. Its role has become more relevant with the increasing use of space navigation technology in the country. Recently, Brazil adopted a new geodetic frame, SIRGAS2000, in February 2005, fully compatible with GNSS technology. The paper provides an overview of the recent modernization phases the RBMC network has undergone highlighting its future steps. From its current post-mission mode, the RBMC will evolve into a real-time network, providing real-time data and real-time correction to users. The network enhanced with modern GPS receivers and the addition of atomic clocks will be used to compute WADGPS-type corrections to be transmitted, in real time, to users in Brazil and surrounding areas. It is estimated that users will be able to achieve a horizontal accuracy around 0.5 m (1 σ) in static and kinematic positioning and better for dual frequency users. The availability of the WADGPS service will allow users to tie to the new SIRGAS2000 frame in a more rapid and transparent way for positioning and navigation applications. It should be emphasized that support to post-mission static positioning, will continue to be provided to users interested in higher accuracy levels. In addition to this, a post-mission Precise Point Positioning (PPP) service will be provided based on the one currently provided by the Geodetic Survey Division of NRCan (CSRS-PPP). The modernization of the RBMC is under development based on a cooperation signed at the end of 2004 with the University of New Brunswick, supported by the Canadian International Development Agency and the Brazilian Cooperation Agency. The Geodetic Survey Division of NRCan is also participating in this modernization effort under the same project. © Springer-Verlag Berlin Heidelberg 2009.
Resumo:
The Patellofemoral Pain Syndrome (PFPS), has a multifactorial etiology and affects approximately 7 to 15% of the population, mostly women, youth, adults and active persons. PFPS causes anterior or retropatelar pain that is exacerbated during functional motor gestures, such as up and down stairs or spending long periods of time sitting, squatting or kneeling. As the diagnostic evaluation of this syndrome is still indirect, different mechanisms and methodologies try to make a classification that distinguishes patients with PFPS in relation to asymptomatic. Thereby, the purpose of this investigation was to determine the characteristics of the electromyographic (EMG) signal in the frequency domain of the vastus medialis oblique (VMO) and vastus lateralis (VL) in patients with PFPS, during the ascent of stairs. 33 young women (22 control group and 11 PFPS group), were evaluated by EMG during ascent of stairs. The VMO mean power frequency (MPF) and the VL frequency 95% (F95) were lower in symptomatic individuals. This may be related to the difference in muscle recruitment strategy exerted by each muscle in the PFPS group compared to the control group.
Resumo:
Delayed feedback (DF) control is a well-established technique to suppress single frequency vibration of a non-minimum phase system. Modal control is also a well-established technique to control multiple vibration modes of a minimum phase system. In this paper these techniques are combined to simultaneously suppress multiple vibration modes of a non-minimum phase system involving a small time delay. The control approach is called delayed resonant feedback (DRF) where each modal controller consists of a modal filter to extract the target mode signal from the vibration response, and a phase compensator to account for the phase delay of the mode. The methodology is first discussed using a single mode system. A multi-mode system is then studied and experimental results are presented to demonstrate the efficacy of the control approach for two modes of a beam. It is shown that the system behaves as if each mode under control has a dynamic vibration absorber attached to it, even though the actuator and the sensor are not collocated and there is a time delay in the control system. © 2013 IOP Publishing Ltd.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
We analyze new results on a magnetically levitated body (a block including a magnet whose bottom pole is set in such a way as to repel the upper pole of a magnetic base) excited by a non-ideal energy source (an unbalanced electric motor of limited power supply). These new results are related to the jump phenomena and increase of power required of such sources near resonance are manifestations of a non-ideal system and they are referred as the Sommerfeld effect, which emulates an energy sink. In this work, we also discuss control strategies to be applied to this system, in resonance conditions, in order to decrease its vibration amplitude and avoiding this apparent energy sink.
Resumo:
A new methodology for the synthesis of tunable patch filters is presented. The methodology helps the designer to perform a theoretical analysis of the filter through a coupling matrix that includes the effect of the tuning elements used to tune the filter. This general methodology accounts for any tuning parameter desired and was applied to the design of a tunable dual-mode patch filter with independent control of center frequency and bandwidth (BW). The bandpass filter uses a single triangular resonator with two etched slots that split the fundamental degenerate modes and form the filter passband. Varactor diodes assembled across the slots are used to vary the frequency of each degenerate fundamental mode independently, which is feasible due to the nature of the coupling scheme of the filter. The varactor diode model used in simulations, their assembling, the dc bias configuration, and measured results are presented. The theory results are compared to the simulations and to measurements showing a very good agreement and validating the proposed methodology. The fabricated filter presents an elliptic response with 20% of center frequency tuning range around 3.2 GHz and a fractional BW variation from 4% to 12% with low insertion loss and high power handling with a 1-dB compression point higher than +14.5 dB.
Resumo:
The main objective of this work is the design and implementation of the digital control stage of a 280W AC/DC industrial power supply in a single low-cost microcontroller to replace the analog control stage. The switch-mode power supply (SMPS) consists of a PFC boost converter with fixed frequency operation and a variable frequency LLC series resonant DC/DC converter. Input voltage range is 85VRMS-550VRMS and the output voltage range is 24V-28V. A digital controller is especially suitable for this kind of SMPS to implement its multiple functionalities and to keep the efficiency and the performance high over the wide range of input voltages. Additional advantages of the digital control are reliability and size. The optimized design and implementation of the digital control stage it is presented. Experimental results show the stable operation of the controlled system and an estimation of the cost reduction achieved with the digital control stage.
Resumo:
High switching frequencies (several MHz) allow the integration of low power DC/DC converters. Although, in theory, a high switching frequency would make possible to implement a conventional Voltage Mode control (VMC) or Peak Current Mode control (PCMC) with very high bandwidth, in practice, parasitic effects and robustness limits the applicability of these control techniques. This paper compares VMC and CMC techniques with the V2IC control. This control is based on two loops. The fast internal loop has information of the output capacitor current and the error voltage, providing fast dynamic response under load and voltage reference steps, while the slow external voltage loop provides accurate steady state regulation. This paper shows the fast dynamic response of the V2IC control under load and output voltage reference steps and its robustness operating with additional output capacitors added by the customer.
Resumo:
This paper presents an adaptive control for the auxiliary circuit, called ARCN (Auxiliary Resonant Commutating Network), used to achieve ZVS in full active bridge converters under a wide load range. Depending on the load conditions, the proposed control adapts the timing of the ARCN to minimize the losses. The principle of operation and implementation considerations are presented for a three phase full active bridge converter, proposing different methods to implement the control according to the specifications. The experimental results shown verify the proposed methodology.
Resumo:
El requerimiento de proveer alta frecuencia de datos en los modernos sistema de comunicación inalámbricos resulta en complejas señales moduladas de radio-frequencia (RF) con un gran ancho de banda y alto ratio pico-promedio (PAPR). Para garantizar la linealidad del comportamiento, los amplificadores lineales de potencia comunes funcionan típicamente entre 4 y 10 dB de back-o_ desde la máxima potencia de salida, ocasionando una baja eficiencia del sistema. La eliminación y restauración de la evolvente (EER) y el seguimiento de la evolvente (ET) son dos prometedoras técnicas para resolver el problema de la eficiencia. Tanto en EER como en ET, es complicado diseñar un amplificador de potencia que sea eficiente para señales de RF de alto ancho de banda y alto PAPR. Una propuesta común para los amplificadores de potencia es incluir un convertidor de potencia de muy alta eficiencia operando a frecuencias más altas que el ancho de banda de la señal RF. En este caso, la potencia perdida del convertidor ocasionado por la alta frecuencia desaconseja su práctica cuando el ancho de banda es muy alto. La solución a este problema es el enfoque de esta disertación que presenta dos arquitecturas de amplificador evolvente: convertidor híbrido-serie con una técnica de evolvente lenta y un convertidor multinivel basado en un convertidor reductor multifase con control de tiempo mínimo. En la primera arquitectura, una topología híbrida está compuesta de una convertidor reductor conmutado y un regulador lineal en serie que trabajan juntos para ajustar la tensión de salida para seguir a la evolvente con precisión. Un algoritmo de generación de una evolvente lenta crea una forma de onda con una pendiente limitada que es menor que la pendiente máxima de la evolvente original. La salida del convertidor reductor sigue esa forma de onda en vez de la evolvente original usando una menor frecuencia de conmutación, porque la forma de onda no sólo tiene una pendiente reducida sino también un menor ancho de banda. De esta forma, el regulador lineal se usa para filtrar la forma de onda tiene una pérdida de potencia adicional. Dependiendo de cuánto se puede reducir la pendiente de la evolvente para producir la forma de onda, existe un trade-off entre la pérdida de potencia del convertidor reductor relacionada con la frecuencia de conmutación y el regulador lineal. El punto óptimo referido a la menor pérdida de potencia total del amplificador de evolvente es capaz de identificarse con la ayuda de modelo preciso de pérdidas que es una combinación de modelos comportamentales y analíticos de pérdidas. Además, se analiza el efecto en la respuesta del filtro de salida del convertidor reductor. Un filtro de dampeo paralelo extra es necesario para eliminar la oscilación resonante del filtro de salida porque el convertidor reductor opera en lazo abierto. La segunda arquitectura es un amplificador de evolvente de seguimiento de tensión multinivel. Al contrario que los convertidores que usan multi-fuentes, un convertidor reductor multifase se emplea para generar la tensión multinivel. En régimen permanente, el convertidor reductor opera en puntos del ciclo de trabajo con cancelación completa del rizado. El número de niveles de tensión es igual al número de fases de acuerdo a las características del entrelazamiento del convertidor reductor. En la transición, un control de tiempo mínimo (MTC) para convertidores multifase es novedosamente propuesto y desarrollado para cambiar la tensión de salida del convertidor reductor entre diferentes niveles. A diferencia de controles convencionales de tiempo mínimo para convertidores multifase con inductancia equivalente, el propuesto MTC considera el rizado de corriente por cada fase basado en un desfase fijo que resulta en diferentes esquemas de control entre las fases. La ventaja de este control es que todas las corrientes vuelven a su fase en régimen permanente después de la transición para que la siguiente transición pueda empezar muy pronto, lo que es muy favorable para la aplicación de seguimiento de tensión multinivel. Además, el control es independiente de la carga y no es afectado por corrientes de fase desbalanceadas. Al igual que en la primera arquitectura, hay una etapa lineal con la misma función, conectada en serie con el convertidor reductor multifase. Dado que tanto el régimen permanente como el estado de transición del convertidor no están fuertemente relacionados con la frecuencia de conmutación, la frecuencia de conmutación puede ser reducida para el alto ancho de banda de la evolvente, la cual es la principal consideración de esta arquitectura. La optimización de la segunda arquitectura para más alto anchos de banda de la evolvente es presentada incluyendo el diseño del filtro de salida, la frecuencia de conmutación y el número de fases. El área de diseño del filtro está restringido por la transición rápida y el mínimo pulso del hardware. La rápida transición necesita un filtro pequeño pero la limitación del pulso mínimo del hardware lleva el diseño en el sentido contrario. La frecuencia de conmutación del convertidor afecta principalmente a la limitación del mínimo pulso y a las pérdidas de potencia. Con una menor frecuencia de conmutación, el ancho de pulso en la transición es más pequeño. El número de fases relativo a la aplicación específica puede ser optimizado en términos de la eficiencia global. Otro aspecto de la optimización es mejorar la estrategia de control. La transición permite seguir algunas partes de la evolvente que son más rápidas de lo que el hardware puede soportar al precio de complejidad. El nuevo método de sincronización de la transición incrementa la frecuencia de la transición, permitiendo que la tensión multinivel esté más cerca de la evolvente. Ambas estrategias permiten que el convertidor pueda seguir una evolvente con un ancho de banda más alto que la limitación de la etapa de potencia. El modelo de pérdidas del amplificador de evolvente se ha detallado y validado mediante medidas. El mecanismo de pérdidas de potencia del convertidor reductor tiene que incluir las transiciones en tiempo real, lo cual es diferente del clásico modelos de pérdidas de un convertidor reductor síncrono. Este modelo estima la eficiencia del sistema y juega un papel muy importante en el proceso de optimización. Finalmente, la segunda arquitectura del amplificador de evolvente se integra con el amplificador de clase F. La medida del sistema EER prueba el ahorro de energía con el amplificador de evolvente propuesto sin perjudicar la linealidad del sistema. ABSTRACT The requirement of delivering high data rates in modern wireless communication systems results in complex modulated RF signals with wide bandwidth and high peak-to-average ratio (PAPR). In order to guarantee the linearity performance, the conventional linear power amplifiers typically work at 4 to 10 dB back-off from the maximum output power, leading to low system efficiency. The envelope elimination and restoration (EER) and envelope tracking (ET) are two promising techniques to overcome the efficiency problem. In both EER and ET, it is challenging to design efficient envelope amplifier for wide bandwidth and high PAPR RF signals. An usual approach for envelope amplifier includes a high-efficiency switching power converter operating at a frequency higher than the RF signal's bandwidth. In this case, the power loss of converter caused by high switching operation becomes unbearable for system efficiency when signal bandwidth is very wide. The solution of this problem is the focus of this dissertation that presents two architectures of envelope amplifier: a hybrid series converter with slow-envelope technique and a multilevel converter based on a multiphase buck converter with the minimum time control. In the first architecture, a hybrid topology is composed of a switched buck converter and a linear regulator in series that work together to adjust the output voltage to track the envelope with accuracy. A slow envelope generation algorithm yields a waveform with limited slew rate that is lower than the maximum slew rate of the original envelope. The buck converter's output follows this waveform instead of the original envelope using lower switching frequency, because the waveform has not only reduced slew rate but also reduced bandwidth. In this way, the linear regulator used to filter the waveform has additional power loss. Depending on how much reduction of the slew rate of envelope in order to obtain that waveform, there is a trade-off between the power loss of buck converter related to the switching frequency and the power loss of linear regulator. The optimal point referring to the lowest total power loss of this envelope amplifier is identified with the help of a precise power loss model that is a combination of behavioral and analytic loss model. In addition, the output filter's effect on the response is analyzed. An extra parallel damping filter is needed to eliminate the resonant oscillation of output filter L and C, because the buck converter operates in open loop. The second architecture is a multilevel voltage tracking envelope amplifier. Unlike the converters using multi-sources, a multiphase buck converter is employed to generate the multilevel voltage. In the steady state, the buck converter operates at complete ripple cancellation points of duty cycle. The number of the voltage levels is equal to the number of phases according the characteristics of interleaved buck converter. In the transition, a minimum time control (MTC) for multiphase converter is originally proposed and developed for changing the output voltage of buck converter between different levels. As opposed to conventional minimum time control for multiphase converter with equivalent inductance, the proposed MTC considers the current ripple of each phase based on the fixed phase shift resulting in different control schemes among the phases. The advantage of this control is that all the phase current return to the steady state after the transition so that the next transition can be triggered very soon, which is very favorable for the application of multilevel voltage tracking. Besides, the control is independent on the load condition and not affected by the unbalance of phase current. Like the first architecture, there is also a linear stage with the same function, connected in series with the multiphase buck converter. Since both steady state and transition state of the converter are not strongly related to the switching frequency, it can be reduced for wide bandwidth envelope which is the main consideration of this architecture. The optimization of the second architecture for wider bandwidth envelope is presented including the output filter design, switching frequency and the number of phases. The filter design area is restrained by fast transition and the minimum pulse of hardware. The fast transition needs small filter but the minimum pulse of hardware limitation pushes the filter in opposite way. The converter switching frequency mainly affects the minimum pulse limitation and the power loss. With lower switching frequency, the pulse width in the transition is smaller. The number of phases related to specific application can be optimized in terms of overall efficiency. Another aspect of optimization is improving control strategy. Transition shift allows tracking some parts of envelope that are faster than the hardware can support at the price of complexity. The new transition synchronization method increases the frequency of transition, allowing the multilevel voltage to be closer to the envelope. Both control strategies push the converter to track wider bandwidth envelope than the limitation of power stage. The power loss model of envelope amplifier is detailed and validated by measurements. The power loss mechanism of buck converter has to include the transitions in real time operation, which is different from classical power loss model of synchronous buck converter. This model estimates the system efficiency and play a very important role in optimization process. Finally, the second envelope amplifier architecture is integrated with a Class F amplifier. EER system measurement proves the power saving with the proposed envelope amplifier without disrupting the linearity performance.