968 resultados para ultrasound ct
Resumo:
The differentiation between benign and malignant focal liver lesions plays an important role in diagnosis of liver disease and therapeutic planning of local or general disease. This differentiation, based on characterization, relies on the observation of the dynamic vascular patterns (DVP) of lesions with respect to adjacent parenchyma, and may be assessed during contrast-enhanced ultrasound imaging after a bolus injection. For instance, hemangiomas (i.e., benign lesions) exhibit hyper-enhanced signatures over time, whereas metastases (i.e., malignant lesions) frequently present hyperenhanced foci during the arterial phase and always become hypo-enhanced afterwards. The objective of this work was to develop a new parametric imaging technique, aimed at mapping the DVP signatures into a single image called a DVP parametric image, conceived as a diagnostic aid tool for characterizing lesion types. The methodology consisted in processing a time sequence of images (DICOM video data) using four consecutive steps: (1) pre-processing combining image motion correction and linearization to derive an echo-power signal, in each pixel, proportional to local contrast agent concentration over time; (2) signal modeling, by means of a curve-fitting optimization, to compute a difference signal in each pixel, as the subtraction of adjacent parenchyma kinetic from the echopower signal; (3) classification of difference signals; and (4) parametric image rendering to represent classified pixels as a support for diagnosis. DVP parametric imaging was the object of a clinical assessment on a total of 146 lesions, imaged using different medical ultrasound systems. The resulting sensitivity and specificity were 97% and 91%, respectively, which compare favorably with scores of 81 to 95% and 80 to 95% reported in medical literature for sensitivity and specificity, respectively.
Resumo:
Die Diagnostik des plötzlichen Herztods durch bildgebende Techniken ist bislang unzureichend evaluiert. Als Validierungsoption für postmortale koronarangiographische Methoden steht der Sektionsbefund zur Verfügung. Sequenziell postmortal durchgeführte alternative angiographische Methoden sind denkbar. Schließlich bietet die ante mortem durchgeführte Koronarangiographie (CA) - ggf. In Verbindung mit der perkutanen transluminalen Koronarangioplastie (PTCA) - weitere Vergleichsmöglichkeiten. Neben deskriptiven sind hier auch potenziell funktionelle Aussagen zum Stenosegrad möglich.
Resumo:
PURPOSE: To assess the outcome and patterns of failure in patients with testicular lymphoma treated by chemotherapy (CT) and/or radiation therapy (RT). METHODS AND MATERIALS: Data from a series of 36 adult patients with Ann Arbor Stage I (n = 21), II (n = 9), III (n = 3), or IV (n = 3) primary testicular lymphoma, consecutively treated between 1980 and 1999, were collected in a retrospective multicenter study by the Rare Cancer Network. Median age was 64 years (range: 21-91 years). Full staging workup (chest X-ray, testicular ultrasound, abdominal ultrasound, and/or thoracoabdominal computer tomography, bone marrow assessment, full blood count, lactate dehydrogenase, and cerebrospinal fluid evaluation) was completed in 18 (50%) patients. All but one patient underwent orchidectomy, and spermatic cord infiltration was found in 9 patients. Most patients (n = 29) had CT, consisting in most cases of cyclophosphamide, doxorubicin, vincristine, and prednisolone (CHOP) with (n = 17) or without intrathecal CT. External RT was delivered to scrotum alone (n = 12) or testicular, iliac, and para-aortic regions (n = 8). The median RT dose was 31 Gy (range: 20-44 Gy) in a median of 17 fractions (10-24), using a median of 1.8 Gy (range: 1.5-2.5 Gy) per fraction. The median follow-up period was 42 months (range: 6-138 months). RESULTS: After a median period of 11 months (range: 1-76 months), 14 patients presented lymphoma progression, mostly in the central nervous system (CNS) (n = 8). Among the 17 patients who received intrathecal CT, 4 had a CNS relapse (p = NS). No testicular, iliac, or para-aortic relapse was observed in patients receiving RT to these regions. The 5-year overall, lymphoma-specific, and disease-free survival was 47%, 66%, and 43%, respectively. In univariate analyses, statistically significant factors favorably influencing the outcome were early-stage and combined modality treatment. Neither RT technique nor total dose influenced the outcome. Multivariate analysis revealed that the most favorable independent factors predicting the outcome were younger age, early-stage disease, and combined modality treatment. CONCLUSIONS: In this multicenter retrospective study, CNS was found to be the principal site of relapse, and no extra-CNS lymphoma progression was observed in the irradiated volumes. More effective CNS prophylaxis, including combined modalities, should be prospectively explored in this uncommon site of extranodal lymphoma.
Resumo:
The aim of this study was to evaluate and compare organ doses delivered to patients in wrist and petrous bone examinations using a multislice spiral computed tomography (CT) and a C-arm cone-beam CT equipped with a flat-panel detector (XperCT). For this purpose, doses to the target organ, i.e. wrist or petrous bone, together with those to the most radiosensitive nearby organs, i.e. thyroid and eye lens, were measured and compared. Furthermore, image quality was compared for both imaging systems and different acquisition modes using a Catphan phantom. Results show that both systems guarantee adequate accuracy for diagnostic purposes for wrist and petrous bone examinations. Compared with the CT scanner, the XperCT system slightly reduces the dose to target organs and shortens the overall duration of the wrist examination. In addition, using the XperCT enables a reduction of the dose to the eye lens during head scans (skull base and ear examinations).
Resumo:
BACKGROUND: Posttransplant lymphoproliferative disease (PTLD) is, aside skin cancer, the most common malignancy occurring after solid organ transplant in adults. Fluorodeoxyglucose (FDG) positron emission tomography (PET) has proved useful in the management of lymphomas. METHODS: We report our experience with the use of FDG-PET inline with computed tomography (CT) scanning in the management of four transplant recipients with histologically confirmed PTLD, including three monomorphic PTLDs and one polymorphic PTLD. RESULTS: FDG-PET/CT scan at diagnosis showed increased FDG uptake in all examined PTLD lesions, and the disease was upstaged on the basis of FDG-PET/CT scan results over conventional CT scanning in one patient. At the end of treatment, PET/CT scans no longer demonstrated FDG uptake in the original PTLD lesions in all patients. Complete remission of disease persisted for at least 1 year after diagnosis in all. CONCLUSIONS: Our results strongly support that FDG-PET scanning is highly specific for diagnosis and follow-up of PTLD. The clinical relevance of including FDG-PET/CT scanning in the management of PTLD should be evaluated in a larger prospective cohort study.
Resumo:
PURPOSE: Determine the effect of repeated intravitreal injections of ranibizumab (0.5 mg; 0.05 ml) on retrobulbar blood flow velocities (BFVs) using ultrasound imaging quantification in twenty patients with exudative age-related macular degeneration treated for 6 months. METHODS: Visual acuity (ETDRS), central macular thickness (OCT), peak-systolic, end-diastolic and mean-BFVs in central retinal (CRA), temporal posterior ciliary (TPCA) and ophthalmic (OA) arteries were measured before, 2 days, 3 weeks and 6 months after the first injection. Patients were examined monthly and received 1-5 additional injections depending on ophthalmologic examination results. RESULTS: Six months after the first injection, a significant increase in visual acuity 50.9 ± 25.9 versus 44.4 ± 21.7 (p < 0.01) and decrease in mean central macular thickness 267 ± 74 versus 377 ± 115 μm (p < 0.001) were observed compared to baseline. Although mean-BFVs decreased by 16%±3% in CRA and 20%±5% in TPCA (p < 0.001) 2 days after the first injection, no significant change was seen thereafter. Mean-BFVs in OA decreased by 19%±5% at week 3 (p < 0.001). However, the smallest number of injections (two injections) was associated with the longest time interval between the last injection and month 6 (20 weeks) and with the best return to baseline levels for mean-BFVs in CRA, suggesting that ranibizumab had reversible effects on native retinal vascular supply after its discontinuation. Moreover, a significant correlation between the number of injections and percentage of changes in mean-BFVs in CRA was observed at month 6 (R = 0.74, p < 0.001) unlike TPCA or OA. CONCLUSION: Ranibizumab could impair the native choroidal and retinal vascular networks, but its effect seems reversible after its discontinuation.
Resumo:
Combined positron emission tomography and computed tomography (PET/CT) scanners play a major role in medicine for in vivo imaging in an increasing number of diseases in oncology, cardiology, neurology, and psychiatry. With the advent of short-lived radioisotopes other than 18F and newer scanners, there is a need to optimize radioisotope activity and acquisition protocols, as well as to compare scanner performances on an objective basis. The Discovery-LS (D-LS) was among the first clinical PET/CT scanners to be developed and has been extensively characterized with older National Electrical Manufacturer Association (NEMA) NU 2-1994 standards. At the time of publication of the latest version of the standards (NU 2-2001) that have been adapted for whole-body imaging under clinical conditions, more recent models from the same manufacturer, i.e., Discovery-ST (D-ST) and Discovery-STE (D-STE), were commercially available. We report on the full characterization both in the two- and three-dimensional acquisition mode of the D-LS according to latest NEMA NU 2-2001 standards (spatial resolution, sensitivity, count rate performance, accuracy of count losses, and random coincidence correction and image quality), as well as a detailed comparison with the newer D-ST widely used and whose characteristics are already published.