955 resultados para time measurement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pulse wave velocity (PWV) is a surrogate of arterial stiffness and represents a non-invasive marker of cardiovascular risk. The non-invasive measurement of PWV requires tracking the arrival time of pressure pulses recorded in vivo, commonly referred to as pulse arrival time (PAT). In the state of the art, PAT is estimated by identifying a characteristic point of the pressure pulse waveform. This paper demonstrates that for ambulatory scenarios, where signal-to-noise ratios are below 10 dB, the performance in terms of repeatability of PAT measurements through characteristic points identification degrades drastically. Hence, we introduce a novel family of PAT estimators based on the parametric modeling of the anacrotic phase of a pressure pulse. In particular, we propose a parametric PAT estimator (TANH) that depicts high correlation with the Complior(R) characteristic point D1 (CC = 0.99), increases noise robustness and reduces by a five-fold factor the number of heartbeats required to obtain reliable PAT measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

QUESTION UNDER STUDY: Purpose was to validate accuracy and reliability of automated oscillometric ankle-brachial (ABI) measurement prospectively against the current gold standard of Doppler-assisted ABI determination. METHODS: Oscillometric ABI was measured in 50 consecutive patients with peripheral arterial disease (n = 100 limbs, mean age 65 +/- 6 years, 31 men, 19 diabetics) after both high and low ABI had been determined conventionally by Doppler under standardised conditions. Correlation was assessed by linear regression and Pearson product moment correlation. Degree of inter-modality agreement was quantified by use of Bland and Altman method. RESULTS: Oscillometry was performed significantly faster than Doppler-assisted ABI (3.9 +/- 1.3 vs 11.4 +/- 3.8 minutes, P <0.001). Mean readings were 0.62 +/- 0.25, 0.70 +/- 0.22 and 0.63 +/- 0.39 for low, high and oscillometric ABI, respectively. Correlation between oscillometry and Doppler ABI was good overall (r = 0.76 for both low and high ABI) and excellent in oligo-symptomatic, non-diabetic patients (r = 0.81; 0.07 +/- 0.23); it was, however, limited in diabetic patients and in patients with critical limb ischaemia. In general, oscillometric ABI readings were slightly higher (+0.06), but linear regression analysis showed that correlation was sustained over the whole range of measurements. CONCLUSIONS: Results of automated oscillometric ABI determination correlated well with Doppler-assisted measurements and could be obtained in shorter time. Agreement was particularly high in oligo-symptomatic non-diabetic patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: The aim of this study was to measure the radiation dose of dual-energy and single-energy multidetector computed tomographic (CT) imaging using adult liver, renal, and aortic imaging protocols. MATERIALS AND METHODS: Dual-energy CT (DECT) imaging was performed on a conventional 64-detector CT scanner using a software upgrade (Volume Dual Energy) at tube voltages of 140 and 80 kVp (with tube currents of 385 and 675 mA, respectively), with a 0.8-second gantry revolution time in axial mode. Parameters for single-energy CT (SECT) imaging were a tube voltage of 140 kVp, a tube current of 385 mA, a 0.5-second gantry revolution time, helical mode, and pitch of 1.375:1. The volume CT dose index (CTDI(vol)) value displayed on the console for each scan was recorded. Organ doses were measured using metal oxide semiconductor field-effect transistor technology. Effective dose was calculated as the sum of 20 organ doses multiplied by a weighting factor found in International Commission on Radiological Protection Publication 60. Radiation dose saving with virtual noncontrast imaging reconstruction was also determined. RESULTS: The CTDI(vol) values were 49.4 mGy for DECT imaging and 16.2 mGy for SECT imaging. Effective dose ranged from 22.5 to 36.4 mSv for DECT imaging and from 9.4 to 13.8 mSv for SECT imaging. Virtual noncontrast imaging reconstruction reduced the total effective dose of multiphase DECT imaging by 19% to 28%. CONCLUSION: Using the current Volume Dual Energy software, radiation doses with DECT imaging were higher than those with SECT imaging. Substantial radiation dose savings are possible with DECT imaging if virtual noncontrast imaging reconstruction replaces precontrast imaging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Quantitative meta-analyses of randomized clinical trials investigating the specific therapeutic efficacy of homeopathic remedies yielded statistically significant differences compared to placebo. Since the remedies used contained mostly only very low concentrations of pharmacologically active compounds, these effects cannot be accounted for within the framework of current pharmacology. Theories to explain clinical effects of homeopathic remedies are partially based upon changes in diluent structure. To investigate the latter, we measured for the first time high-field (600/500 MHz) 1H T1 and T2 nuclear magnetic resonance relaxation times of H2O in homeopathic preparations with concurrent contamination control by inductively coupled plasma mass spectrometry (ICP-MS). Homeopathic preparations of quartz (10c–30c, n = 21, corresponding to iterative dilutions of 100−10–100−30), sulfur (13x–30x, n = 18, 10−13–10−30), and copper sulfate (11c–30c, n = 20, 100−11–100−30) were compared to n = 10 independent controls each (analogously agitated dilution medium) in randomized and blinded experiments. In none of the samples, the concentration of any element analyzed by ICP-MS exceeded 10 ppb. In the first measurement series (600 MHz), there was a significant increase in T1 for all samples as a function of time, and there were no significant differences between homeopathic potencies and controls. In the second measurement series (500 MHz) 1 year after preparation, we observed statistically significant increased T1 relaxation times for homeopathic sulfur preparations compared to controls. Fifteen out of 18 correlations between sample triplicates were higher for controls than for homeopathic preparations. No conclusive explanation for these phenomena can be given at present. Possible hypotheses involve differential leaching from the measurement vessel walls or a change in water molecule dynamics, i.e., in rotational correlation time and/or diffusion. Homeopathic preparations thus may exhibit specific physicochemical properties that need to be determined in detail in future investigations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is focused on the integration of state-of-the-art technologies in the fields of telecommunications, simulation algorithms, and data mining in order to develop a Type 1 diabetes patient's semi to fully-automated monitoring and management system. The main components of the system are a glucose measurement device, an insulin delivery system (insulin injection or insulin pumps), a mobile phone for the GPRS network, and a PDA or laptop for the Internet. In the medical environment, appropriate infrastructure for storage, analysis and visualizing of patients' data has been implemented to facilitate treatment design by health care experts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND CONTEXT A new device, DensiProbe, has been developed to provide surgeons with intraoperative information about bone strength by measuring the peak breakaway torque. In cases of low bone quality, the treatment can be adapted to the patient's condition, for example, by improving screw-anchorage with augmentation techniques. PURPOSE The objective of this study was to investigate the feasibility of DensiProbe Spine in patients undergoing transpedicular fixation. STUDY DESIGN Prospective feasibility study on consecutive patients. PATIENT SAMPLE Fourteen women and 16 men were included in this study. OUTCOME MEASURES Local and general bone quality. METHODS These consecutive patients scheduled for transpedicular fixation were evaluated for bone mineral density (BMD), which was measured globally by dual-energy X-ray absorptiometry and locally via biopsies using quantitative microcomputed tomography. The breakaway torque force within the vertebral body was assessed intraoperatively via the transpedicular approach with the DensiProbe Spine. The results were correlated with the areal BMD at the lumbar spine and the local volumetric BMD (vBMD) and a subjective impression of bone strength. The feasibility of the method was evaluated, and the clinical and radiological performance was evaluated over a 1-year follow-up. This study was funded by an AO Spine research grant; DensiProbe was developed at the AO Research Institute Davos, Switzerland; the AO Foundation is owner of the intellectual property rights. RESULTS In 30 patients, 69 vertebral levels were examined. The breakaway torque consistently correlated with an experienced surgeon's quantified impression of resistance as well as with vBMD of the same vertebra. Beyond a marginal prolongation of surgery time, no adverse events related to the usage of the device were observed. CONCLUSIONS The intraoperative transpedicular measurement of the peak breakaway torque was technically feasible, safe, and reliably predictive of local vBMD during dorsal spinal instrumentations in a clinical setting. Larger studies are needed to define specific thresholds that indicate a need for the augmentation or instrumentation of additional levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

DCE-MRI is an important technique in the study of small animal cancer models because its sensitivity to vascular changes opens the possibility of quantitative assessment of early therapeutic response. However, extraction of physiologically descriptive parameters from DCE-MRI data relies upon measurement of the vascular input function (VIF), which represents the contrast agent concentration time course in the blood plasma. This is difficult in small animal models due to artifacts associated with partial volume, inflow enhancement, and the limited temporal resolution achievable with MR imaging. In this work, the development of a suite of techniques for high temporal resolution, artifact resistant measurement of the VIF in mice is described. One obstacle in VIF measurement is inflow enhancement, which decreases the sensitivity of the MR signal to the presence of contrast agent. Because the traditional techniques used to suppress inflow enhancement degrade the achievable spatiotemporal resolution of the pulse sequence, improvements can be achieved by reducing the time required for the suppression. Thus, a novel RF pulse which provides spatial presaturation contemporaneously with the RF excitation was implemented and evaluated. This maximizes the achievable temporal resolution by removing the additional RF and gradient pulses typically required for suppression of inflow enhancement. A second challenge is achieving the temporal resolution required for accurate characterization of the VIF, which exceeds what can be achieved with conventional imaging techniques while maintaining adequate spatial resolution and tumor coverage. Thus, an anatomically constrained reconstruction strategy was developed that allows for sampling of the VIF at extremely high acceleration factors, permitting capture of the initial pass of the contrast agent in mice. Simulation, phantom, and in vivo validation of all components were performed. Finally, the two components were used to perform VIF measurement in the murine heart. An in vivo study of the VIF reproducibility was performed, and an improvement in the measured injection-to-injection variation was observed. This will lead to improvements in the reliability of quantitative DCE-MRI measurements and increase their sensitivity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. The aim of this research was to evaluate the effect of enteral feeding on tonometric measurement of gastric regional carbon dioxide levels (PrCO2) in normal healthy volunteers. Design and methods. The sample included 12 healthy volunteers recruited by the University Clinical Research Center (UCRC). An air tonometry system monitored PrCO2 levels using a tonometer placed in the lumen of the stomach via orogastric intubation. PrCO2 was automatically measured and recorded every 10 minutes throughout the five hour study period. An oral dose of famotidine 40 mg was self-administered the evening prior to and the morning of the study. Instillation of Isocal® High Nitrogen (HN) was used for enteral feeding in hourly escalating doses of 0, 40, 60, and 80 ml/hr with no feeding during the fifth hour. Results . PrCO2 measurements at time 0 and 10 minutes (41.4 ± 6.5 and 41.8 ± 5.7, respectively) demonstrated biologic precision (Levene's Test statistic = 0.085, p-value 0.774). Biologic precision was lost between T130 and T140 40 when compared to baseline TO (Levene's Test statistic = 1.70, p-value 0.205; and 3.205, p-value 0.042, respectively) and returned to non-significant levels between T270 and T280 (Levene's Test statistic = 3.083, p-value 0.043; and 2.307, p-value 0.143, respectively). Isocal® HN significantly affected the biologic accuracy of PrCO2 measurements (repeated measures ANOVA F 4.91, p-value <0.001). After 20 minutes of enteral feeding at 40 ml/hr, PrCO2 significantly increased (41.4 ± 6.5 to 46.6 ± 4.25, F = 5.4, p-value 0.029). Maximum variance from baseline (41.4 ± 6.5 to 61.3 ± 15.2, F = 17.22, p-value <0.001) was noted after 30 minutes of Isocal® HN at 80 ml/hr or 210 minutes from baseline. The significant elevations in PrCO2 continued throughout the study. Sixty minutes after discontinuation of enteral feeding, PrCO2 remained significantly elevated from baseline (41.4 ± 6.5 to 51.8 ± 9.2, F = 10.15, p-value 0.004). Conclusion. Enteral feeding with Isocal® HN significantly affects the precision and accuracy of PrCO2 measurements in healthy volunteers. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Accurate measurement of abdominal aortic aneurysms is necessary to predict rupture risk and, more recently, to follow aneurysm sac behavior following endovascular repair. Up until this point, aneurysm diameter has been the most common measurement utilized for these purposes. Although aneurysm diameter is predictive of rupture, accurate measurement is hindered by such factors as aortic tortuosity and interobserver variability, and it does not account for variations in morphology such as saccular aneurysms. Additionally, decreases in aneurysm diameter do not completely describe the somewhat complex remodeling seen following endovascular repair of aortic aneurysms. Measurement of aneurysm volume has the advantage of describing aneurysm morphology in a multidimensional fashion, but it has not been readily available or easily measured until recently. This has changed with the introduction of commercially available software tools that permit quicker and easier to perform volume measurements. Whether it is time for volume to replace, or compliment, diameter is the subject of the current debate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In spring 2012 CERN provided two weeks of a short bunch proton beam dedicated to the neutrino velocity measurement over a distance of 730 km. The OPERA neutrino experiment at the underground Gran Sasso Laboratory used an upgraded setup compared to the 2011 measurements, improving the measurement time accuracy. An independent timing system based on the Resistive Plate Chambers was exploited providing a time accuracy of ∼1 ns. Neutrino and anti-neutrino contributions were separated using the information provided by the OPERA magnetic spectrometers. The new analysis profited from the precision geodesy measurements of the neutrino baseline and of the CNGS/LNGS clock synchronization. The neutrino arrival time with respect to the one computed assuming the speed of light in vacuum is found to be δtν≡TOFc−TOFν=(0.6±0.4 (stat.)±3.0 (syst.)) ns and δtν¯≡TOFc−TOFν¯=(1.7±1.4 (stat.)±3.1 (syst.)) ns for νμ and ν¯μ, respectively. This corresponds to a limit on the muon neutrino velocity with respect to the speed of light of −1.8×10−6<(vν−c)/c<2.3×10−6 at 90% C.L. This new measurement confirms with higher accuracy the revised OPERA result.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We consider a large quantum system with spins 12 whose dynamics is driven entirely by measurements of the total spin of spin pairs. This gives rise to a dissipative coupling to the environment. When one averages over the measurement results, the corresponding real-time path integral does not suffer from a sign problem. Using an efficient cluster algorithm, we study the real-time evolution from an initial antiferromagnetic state of the two-dimensional Heisenberg model, which is driven to a disordered phase, not by a Hamiltonian, but by sporadic measurements or by continuous Lindblad evolution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Current wisdom in cosmology has it that the Universe is about 13.8 billions year old. Statements about the age of the Universe are not just difficult to confirm, but also carry a lot of presuppositions. The aim of this talk is to make explicit these presuppositions, to discuss their significance and to trace the implications for an emipirical investigation of the age of the Universe.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present research analyses the adequacy of the widely used Career Satisfaction Scale (CSS; Greenhaus, Parasuraman, & Wormley, 1990) for measuring change over time. We used data of a sample of 1,273 professionals over a 5-year time period. First, we tested longitudinal measurement invariance of the CSS. Second, we analysed changes in career satisfaction by means of multiple indicator latent growth modelling (MLGM). Results revealed that the CSS can be reliably used in mean change analyses. Altogether, career satisfaction was relatively stable over time; however, we found significant variance in intra-individual growth trajectories and a negative correlation between the initial level of and changes in career satisfaction. Professionals who were initially highly satisfied became less satisfied over time. Theoretical and practical implications with respect to the construct of career satisfaction and its development over time (i.e., alpha, beta, and gamma change) are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present research is concerned with the direction of influence between objective and subjective career success. We conducted a prospective longitudinal study with five waves of measurement that covered a time span of 10 years. Participants were professionals working in different occupational fields (N=1,336). We modelled the changes in objective success (income, hierarchical position), in other-referent subjective success (subjective success as compared to a reference group), and in self-referent subjective success (job satisfaction) by means of latent growth curve analysis. Objective success influenced both the initial level and the growth of other-referent subjective success, but it had no influence on job satisfaction. Most importantly, both measures of subjective success and both their initial levels and their changes had strong influences on the growth of objective success. We conclude that the ‘objective success influences subjective success’ relationship is smaller than might be expected, whereas the ‘subjective success influences objective success’ relationship is larger than might be expected.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An experiment was conducted to determine the effect of grazing versus zero-grazing on energy expenditure (EE), feeding behaviour and physical activity in dairy cows at different stages of lactation. Fourteen Holstein cows were subjected to two treatments in a repeated crossover design with three experimental series (S1, S2, and S3) reflecting increased days in milk (DIM). At the beginning of each series, cows were on average at 38, 94 and 171 (standard deviation (SD) 10.8) DIM, respectively. Each series consisted of two periods containing a 7-d adaptation and a 7-d collection period each. Cows either grazed on pasture for 16–18.5 h per day or were kept in a freestall barn and had ad libitum access to herbage harvested from the same paddock. Herbage intake was estimated using the double alkane technique. On each day of the collection period, EE of one cow in the barn and of one cow on pasture was determined for 6 h by using the 13C bicarbonate dilution technique, with blood sample collection done either manually in the barn or using an automatic sampling system on pasture. Furthermore, during each collection period physical activity and feeding behaviour of cows were recorded over 3 d using pedometers and behaviour recorders. Milk yield decreased with increasing DIM (P<0.001) but was similar with both treatments. Herbage intake was lower (P<0.01) for grazing cows (16.8 kg dry matter (DM)/d) compared to zero-grazing cows (18.9 kg DM/d). The lowest (P<0.001) intake was observed in S1 and similar intakes were observed in S2 and S3. Within the 6-h measurement period, grazing cows expended 19% more (P<0.001) energy (319 versus 269 kJ/kg metabolic body size (BW0.75)) than zero-grazing cows and differences in EE did not change with increasing DIM. Grazing cows spent proportionally more (P<0.001) time walking and less time standing (P<0.001) and lying (P<0.05) than zero-grazing cows. The proportion of time spent eating was greater (P<0.001) and that of time spent ruminating was lower (P<0.05) for grazing cows compared to zero-grazing cows. In conclusion, lower feed intake along with the unchanged milk production indicates that grazing cows mobilized body reserves to cover additional energy requirements which were at least partly caused by more physical activity. However, changes in cows׳ behaviour between the considered time points during lactation were too small so that differences in EE remained similar between treatments with increasing DIM.