931 resultados para the crack extension rate
Resumo:
Objective: To assess the influence of energy and pulse repetition rate of Er:YAG laser on the enamel ablation ability and substrate morphology. Methods: Fifteen crowns of molars were sectioned in four fragments, providing 60 samples, which were ground to flatten the enamel surface. The initial mass was obtained by weighing the fragments. The specimens were hydrated for I h, fixed, and a 3-mm-diameter area was delimited. Twelve groups were randomly formed according to the combination of laser energies (200, 250, 300, or 350 mJ) and pulse repetition rates (2, 3, or 4 Hz). The final mass was obtained and mass loss was calculated by the difference between the initial and final mass. The specimens were prepared for SEM. Data were submitted to ANOVA and Scheffe test. Results: The 4 Hz frequency resulted in higher mass loss and was statistically different from 2 and 3 Hz (p < 0.05). The increase of frequency produced more melted areas, cracks, and unselective and deeper ablation. The 350 mJ energy promoted greater mass loss, similar to 300 mJ. Conclusions: The pulse repetition rate influenced more intensively the mass loss and morphological alteration. Among the tested parameters, 350 mJ/3 Hz improved the ability of enamel ablation with less surface morphological alterations. (C) 2007 Wiley Periodicals, Inc. J Biomed Mater Res.
Resumo:
The article reviews the modelling of District Metered Areas (DMAs) with relatively high leakage rate. As a generally recognised approach in modelling of leakage does not exist, modelling of leakage by enginners and other researchers usually takes place by dividing the whole leakage rate evenly to all available nodes of the model. In this article, a new methodology is proposed to determine the nodal leakage by using a hydraulic model. The proposed methodology takes into consideration the IWA water balance methodology, the Minimum Night Flow (MNF) analysis, the number of connections related to each node and the marerial of pipes. In addition, the model is illustrated by a real case study, as it was applied in Kalipoli’s DMA. Results show that the proposed model gives reliable results.
Resumo:
This paper reviews part of the political economy literature on exchange rate policy relevant to understanding the political motivations behind the Brazilian exchange rate policy. We shall first examine the distributive role of the exchange rate, and the way it unfolds in terms of the desired political goals. We will follow by analyzing exchange policy as indicative of government effciency prior to elections. Finally, we discuss fiscal policy from the point of view of political economy, in which the exchange rate results from the macroeconomic equilibrium. Over this review, the Brazilian exchange rate policy is discussed in light of the theories presented.
Resumo:
This paper was developed as part of a broader research program on the political economy of exchange rate policies in Latin America and the Caribbean. We are grateful for helpful comments and suggestions from Jeff Frieden, Ernesto Stein, Jorge Streb, Marcelo Neri and seminar participants at Getulio Vargas Foundation, PUC-Rio, IDB workshop on The Political Economy of Exchange Rate Policies in Latin America and the Caribbean, and LACEA meeting in Buenos Aires. We thank René Garcia for providing us with a Fortran program for estimating the Markov Switching Model, Ilan Goldfajn for sending us updated estimates of the real exchange rate series of Goldfajn and Valdés (1996), Altamir Lopes and Ricardo Markwald for kindly furnishing data on Brazilian external accounts, and Carla Bernardes, Gabriela Domingues, Juliana Pessoa de Araújo, and, specially, Marcelo Pinheiro for excellent research assistant. Both authors thank CNPq for a research fellowship.
Resumo:
In a general equilibrium model. we show that the value of the equilibrium real exchange rate is affected by its own volatility. Risk averse exporters. that make their exporting decision before observing the realization of the real exchange rate. choose to export less the more volatile is the real exchange rate. Therefore the trude balance and the variance of the real exchange rate are negatively related. An increase in the volatility of the real exchange rate for instance deteriorates the trade balance and to restore equilibrium a real exchange rate depreciation has to take place. In the empirical part of the paper we use the traditional (unconditional) standard deviation of RER changes as our measure of RER volatility.We describe the behavior of the RER volatility for Brazil,Argentina and Mexico.Monthly data for the three countries are used. and also daily data for Bruzil. Interesting patterns of volatility could be associated to the nature of the several stabilization plans adopted in those countries and to changes in the exchange rate regimes .
Resumo:
The objective of these notes is to present a simple mathematical model of the determination of current account real exchange rate as defined by Bresser-Pereira (2010); i.e. the real exchange rate that guarantees the inter temporal equilibrium of balance of payments and to show the relation between Real Exchange rate and Productive Specialization at theoretical and empirical level.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Reptiles, particularly snakes, exhibit large and quantitatively similar increments in metabolic rate during muscular exercise and following a meal, when they are apparently inactive. The cardiovascular responses are similar during these two states, but the underlying autonomic control of the heart remains unknown. We describe both adrenergic and cholinergic tonus on the heart during rest, during enforced activity and during digestion (24-36h after ingestion of 30% of their body mass) in the snake Boa constrictor. The snakes were equipped with an arterial catheter for measurements of blood pressure and heart rate, and autonomic tonus was determined following infusion of the beta -adrenergic antagonist propranolol (3mg kg(-1)) and the muscarinic cholinoceptor antagonist atropine (3 mg kg-1).The mean heart rate of fasting animals at rest was 26.4 +/- 1.4 min(-1), and this increased to 36.1 +/- 1.4 min(-1) (means +/- S.E.M.; N=8) following double autonomic block (atropine and propranolol). The calculated cholinergic and adrenergic tones were 60.1 +/- 0.3% and 19.8 +/- 2.2%, respectively. Heart rate increased to 61.4 +/- 1.5 min(-1) during enforced activity, and this response was significantly reduced by propranolol (maximum values of 35.8 +/-1.6 min(-1)), but unaffected by atropine. The cholinergic and adrenergic tones were 2.6 +/- 2.2 and 41.3 +/- 1.9 % during activity, respectively. Double autonomic block virtually abolished tachycardia associated with enforced activity (heart rate increased significantly from 36.1 +/- 1.4 to 37.6 +/- 1.3 min(-1)), indicating that non-adrenergic, non-cholinergic effectors are not involved in regulating heart rate during activity. Blood pressure also increased during activity.Digestion was accompanied by an increase in heart rate from 25.6 +/- 1.3 to 47.7 +/- 2.2 min(-1) (N=8). In these animals, heart rate decreased to 44.2 +/- 2.7 min-1 following propranolol infusion and increased to 53.9 +/- 1.8 min-1 after infusion of atropine, resulting in small cholinergic and adrenergic tones (6.0 +/- 3.5 and 11.1 +/- 1.1 %, respectively). The heart rate of digesting snakes was 47.0 +/- 1.0 min(-1) after double autonomic blockade, which is significantly higher than the value of 36.1 1.4 min-1 in double-blocked fasting animals at rest. Therefore, it appears that some other factor exerts a positive chronotropic effect during digestion, and we propose that this factor may be a circulating regulatory peptide, possibly liberated from the gastrointestinal system in response to the presence of food.
Resumo:
We hypothesized that reducing the size of the ovulatory follicle using aspiration and GnRH would reduce the size of the resulting CL, reduce circulating progesterone concentrations, and alter conception rates. Lactating dairy cows (n=52) had synchronized ovulation and AI by treating with GnRH and PGF(2 alpha) as follows: Day -9, GnRH (100 mug); Day -2, PGF(2 alpha) (25 mg); Day 0, GnRH (100 mug); Day 1, AI. Treated cows (aspirated group; n=29) had all follicles > 4 mm in diameter aspirated on Days -5 or -6 in order to start a new follicular wave. Control cows (nonaspirated group; n=23) had no follicle aspiration. The size of follicles and CL were monitored by ultrasonography. The synchronized ovulation rate (ovulation rate to second GnRH injection; 42/52=80.8%) and double ovulation rate of synchronized cows (6/42=14.3%) did not differ (P > 0.05) between groups. Aspiration reduced the size of the ovulatory follicle (P < 0.0001; 11.5 +/- 0.2 vs 14.5 +/- 0.4 mm), and serum estradiol concentrations at second GnRH treatment (P < 0.0002; 2.5 +/- 0.4 vs 5.7 +/- 0.6 pg/mL). The volume of CL was less (P < 0.05) for aspirated than nonaspirated cows on Day 7 (2,862 +/- 228 vs 5,363 +/- 342 mm(3)) or Day 14 (4,652 +/- 283 vs 6,526 +/- 373 mm(3)). Similarly, serum progesterone concentrations were less on Day 7 (P < 0.05) and Day 14 (P < 0.10) for aspirated cows. Pregnancy rate per AI for synchronized cows was lower (P < 0.05) for aspirated (3/21=14.3%) than nonaspirated (10/21=47.6%) cows. In conclusion, ovulation of smaller follicles produced lowered fertility possibly because development of smaller CL decreased circulating progesterone concentrations. (C) 2001 by Elsevier B.V.
Resumo:
This work presents a methodology for elastic-plastic fracture reliability analysis of plane and axisymmetric structures. The structural reliability analysis is accomplished by means of the FORM analytical method. The virtual crack extension technique based on a direct minimization of potencial energy is utililized for the calculation of the energy release rate. Results are presented to illustrate the performance of the adopted methodology.
Resumo:
The compaction rate, the relation between the density of the wood panel and the density of the wood used for producing the particles, is an indicator of the product's densification. Among the various types of wood panels, particleboards are widely employed in the lumber industry, mainly for the furniture production. This paper presents a study of the relation between the compaction rate and the properties of tensile strength perpendicular to surface, Modulus of Rupture (MOR) and Modulus of Elasticity (MOE) obtained from a static bending test, thickness swelling and water absorption (2 and 24 hours). These properties were calculated according to the Brazilian ABNT, NBR 14810 standard. Particleboards were produced using the species Pinus elliotti and adhesive ureaformaldehyde. The relation was established by a multiple linear regression, and the most appropriate statistical models were determined. The estimated models indicate statistically significant effects of water absorption in 2 hours and MOR in the particleboards' compaction rate.
Resumo:
The purpose of this randomized study was to evaluate EMG spectral, subjective and cardiovascular recovery parameters after isometric lumbar extension contractions. Ten healthy women performed isometric lumbar extensions until exhaustion with 5%, 10%, 15% and 20% of maximal voluntary isometric contraction on 4 different days (random order). One baseline five second contraction was performed before the fatiguing task which was followed by eight submaximal five second extension contractions (until 20 minutes after the end of the fatiguing task) at the same intensity as the trial to evaluate muscle recovery. EMG (Median Frequency, Peak Power, Peak Power Frequency, Total Power and Zero-crossing Rate) and cardiovascular variables did not demonstrate any statistical difference between the 5-second contractions (p > 0.05) performed before and after the fatiguing task, showing a quick EMG recovery. However, the data analysis showed that the perceived effort variable had not recovered even 10 minutes after the fatigue contraction (p < 0.05). Our results represent a data basis for future comparisons and since subjective felling can affect performance, this study shows the importance of its analysis, since the subjective effort rate was not fully recovered after 10 minutes the end of the exhaustion contraction. © 2008 IOS Press. All rights reserved.
Resumo:
Thermal transformations on microalloyed steels can produce multiphase microstructures with different amounts of ferrite, martensite, bainite and retained austenite. These different phases, with distinct morphologies, are determinant of the mechanical behavior of the steel and can, for instance, affect the crack path or promote crack shielding, thus resulting in changes on its propagation rate under cyclic loading. The aim of the present work is to evaluate the effects of microstructure on the tensile strength and fatigue crack growth (FCG) behaviour of a 0.08%C-1,5%Mn (wt. pct.) microalloyed steel, recently developed by a Brazilian steel maker under the designation of RD480. This steel is being considered as a promising alternative to replace low carbon steel in wheel components for the automotive industry. Various microstructural conditions were obtained by means of heat treatments followed by water quench, in which the material samples were kept at the temperatures of 800, 950 and 1200 °C. In order to describe the FCG behavior, two models were tested: the conventional Paris equation and a new exponential equation developed for materials showing non-linear FCG behavior. The results allowed correlating the tensile properties and crack growth resistance to the microstructural features. It is also shown that the Region II FCG curves of the dual and multiphase microstructural conditions present crack growth transitions that are better modeled by dividing them in two parts. The fracture surfaces of the fatigued samples were observed via scanning electron microscopy in order to reveal the fracture mechanisms presented by the various material conditions. © 2010 Published by Elsevier Ltd.
Resumo:
Includes bibliography
Resumo:
Includes bibliography