912 resultados para stampa, 3D, manifattura, additiva, prototipazione
Resumo:
BACKGROUND: Left atrial (LA) dilatation is associated with a large variety of cardiac diseases. Current cardiovascular magnetic resonance (CMR) strategies to measure LA volumes are based on multi-breath-hold multi-slice acquisitions, which are time-consuming and susceptible to misregistration. AIM: To develop a time-efficient single breath-hold 3D CMR acquisition and reconstruction method to precisely measure LA volumes and function. METHODS: A highly accelerated compressed-sensing multi-slice cine sequence (CS-cineCMR) was combined with a non-model-based 3D reconstruction method to measure LA volumes with high temporal and spatial resolution during a single breath-hold. This approach was validated in LA phantoms of different shapes and applied in 3 patients. In addition, the influence of slice orientations on accuracy was evaluated in the LA phantoms for the new approach in comparison with a conventional model-based biplane area-length reconstruction. As a reference in patients, a self-navigated high-resolution whole-heart 3D dataset (3D-HR-CMR) was acquired during mid-diastole to yield accurate LA volumes. RESULTS: Phantom studies. LA volumes were accurately measured by CS-cineCMR with a mean difference of -4.73 ± 1.75 ml (-8.67 ± 3.54%, r2 = 0.94). For the new method the calculated volumes were not significantly different when different orientations of the CS-cineCMR slices were applied to cover the LA phantoms. Long-axis "aligned" vs "not aligned" with the phantom long-axis yielded similar differences vs the reference volume (-4.87 ± 1.73 ml vs. -4.45 ± 1.97 ml, p = 0.67) and short-axis "perpendicular" vs. "not-perpendicular" with the LA long-axis (-4.72 ± 1.66 ml vs. -4.75 ± 2.13 ml; p = 0.98). The conventional bi-plane area-length method was susceptible for slice orientations (p = 0.0085 for the interaction of "slice orientation" and "reconstruction technique", 2-way ANOVA for repeated measures). To use the 3D-HR-CMR as the reference for LA volumes in patients, it was validated in the LA phantoms (mean difference: -1.37 ± 1.35 ml, -2.38 ± 2.44%, r2 = 0.97). Patient study: The CS-cineCMR LA volumes of the mid-diastolic frame matched closely with the reference LA volume (measured by 3D-HR-CMR) with a difference of -2.66 ± 6.5 ml (3.0% underestimation; true LA volumes: 63 ml, 62 ml, and 395 ml). Finally, a high intra- and inter-observer agreement for maximal and minimal LA volume measurement is also shown. CONCLUSIONS: The proposed method combines a highly accelerated single-breathhold compressed-sensing multi-slice CMR technique with a non-model-based 3D reconstruction to accurately and reproducibly measure LA volumes and function.
Resumo:
AIMS AND BACKGROUND: The standard treatment of anal canal cancer (ACC) is combined chemotherapy and radiation therapy (RT), which is complex because of the shape of the target volumes and the need to minimize the irradiation of normal pelvic structures. In this study we compared the dosimetric results of helical tomotherapy (HT) plans with traditional 3D conformal RT (3DRT) plans for the treatment of ACC. METHODS AND STUDY DESIGN: Twelve patients (median age 57 years, range 38-83; F/M 8/4) treated with HT and concurrent chemotherapy for locally advanced ACC were selected. All had histologically confirmed squamous-cell carcinoma. A clinical target volume including the tumor and pelvic and inguinal lymph nodes was treated with HT to a total dose of 36 Gy in 1.8-Gy daily fractions. Then a sequential boost of 23.4 Gy in 1.8-Gy daily fractions (total dose 59.4 Gy) was delivered to the tumor and involved nodes. For all 12 patients, 3DRT plans were generated for comparison. Treatment plans were evaluated by means of standard dose-volume histograms. Dose coverage of the planning target volumes (PTVs), homogeneity index (HI), and mean doses to organs at risk (OARs) were compared. RESULTS: The coverage of PTV was comparable between the two treatment plans. HI was better in the HT vs. 3DRT plans (1.25 and 3.57, respectively; p<0.0001). HT plans resulted in better sparing of OARs (p<0.0001). CONCLUSIONS: HT showed superior target dose conformality and significant sparing of pelvic structures compared with 3DRT. Further investigation should determine if these dosimetric improvements will improve clinical outcomes regarding locoregional control, survival, and treatment-related acute and late morbidity.
Resumo:
3D-suunnittelujärjestelmät ovat tärkeitä työkaluja tuotetiedon luomista ja muokkaamista varten, joten niiden tehokas toiminta yhdessä tuotetiedonhallintajärjestelmien kanssa on erittäin tärkeää. 3D-suunnittelujärjestelmien kehityksen seurauksena 3D-malleihin voidaan sisällyttää entistä enemmän tuotetietoa, jolloin tehokas tiedon tallentaminen ja sen hallinta kasvattaa merkitystään. 3D-malleihin sisältyvää tietoa, kuten esimerkiksi kappaleen painoa tai geometriaa, halutaan myös tarkastella ilman tiettyä 3D-järjestelmää. Tuotetiedon hallinta on ollut jo pitkään tärkeä osa tuotteen suunnitteluprosessia. Tuotetiedon hallintaan sisältyy tiedon luomista, keräämistä ja muokkaamista koko tuotteen eliniän ajan. Näitä tietoja voivat olla esimerkiksi piirustukset, 3D-mallit, mittauspöytäkirjat, kokouspöytäkirjat, mallistoluettelot, lujuuslaskelmat, huoltoraportit jne. Tuotetiedonhallintajärjestelmä pitää huolta kaikesta tästä tiedosta ja sen kautta tuotteisiin liittyvää tietoa voidaan myös muokata ja jakaa tehokkaasti. Tässä diplomityössä tutkittiin näiden kahden järjestelmän integraation toteutusta erilaisilla menetelmillä. Työn tarkoituksena oli valita Valtra Oy:n tarkoituksiin parhaiten sopiva menetelmä tuotetiedon siirtämiseksi järjestelmien välillä tehokkaasti. Työn tuloksena annetaan suositus käytettävistä menetelmistä ja työkaluista.
Resumo:
Tämä diplomityö on tehty Andritz Oy:lle Washers & Filters tuoteryhmään. Työ on osa 3D-suunnittelujärjestelmän käyttöönottoprojektia. Tavoitteena on arvioida uuden laitesuunnittelujärjestelmän vaikutuksia yrityksen tietojärjestelmiin ja toimintatapoihin sekä etsiä potentiaalisia tulevaisuuden kehityskohteita. Suunnittelutietoa hyödyntäviä sidosryhmien edustajia haastattelemalla selvitettiin järjestelmille ja ohjelmistoille asetettavia vaatimuksia. Ohjelmistoihin tutustumalla saatiin käsitys niiden nykytilasta ja kehityssuunnista. 3D-geometrian hyödyntämiseen perustuvilla järjestelmillä voidaan poistaa päällekäistä työtä sekä lyhentää läpimenoaikoja suunnittelussa ja valmistuksessa sijoittamalla työvaiheita rinnakkain. Suurimmat 3D-suunnittelun edut saavutetaan tuotekehitysvaiheessa, tuotemuutoksia tehtäessä sekä valmistusprosesseja suunniteltaessa. Ongelmallisimmat osa-alueet tietojärjestelmien kehittämisessä ovat ensi-sijaisesti tiedonsiirto ohjelmistojen välillä, työntekijöiden muutosvastarinta sekä laadukkaiden järjestelmien korkea hinta. Laajojen tietojärjestelmä-projektien läpivienti on hyvin haastavaa ja onnistuminen vaatii kaikkien sidosryhmien mukana olemista ja tarkkaa projektin koordinointia.
Resumo:
The goal of this study was to investigate the performance of 3D synchrotron differential phase contrast (DPC) imaging for the visualization of both macroscopic and microscopic aspects of atherosclerosis in the mouse vasculature ex vivo. The hearts and aortas of 2 atherosclerotic and 2 wild-type control mice were scanned with DPC imaging with an isotropic resolution of 15 μm. The coronary artery vessel walls were segmented in the DPC datasets to assess their thickness, and histological staining was performed at the level of atherosclerotic plaques. The DPC imaging allowed for the visualization of complex structures such as the coronary arteries and their branches, the thin fibrous cap of atherosclerotic plaques as well as the chordae tendineae. The coronary vessel wall thickness ranged from 37.4 ± 5.6 μm in proximal coronary arteries to 13.6 ± 3.3 μm in distal branches. No consistent differences in coronary vessel wall thickness were detected between the wild-type and atherosclerotic hearts in this proof-of-concept study, although the standard deviation in the atherosclerotic mice was higher in most segments, consistent with the observation of occasional focal vessel wall thickening. Overall, DPC imaging of the cardiovascular system of the mice allowed for a simultaneous detailed 3D morphological assessment of both large structures and microscopic details.
Resumo:
Las navidades pasadas se presentó en las salas de cine El Cascanueces en 3D. Se trata de una adaptación libre del cuento de hadas de Navidad El Cascanueces y el rey de los ratones,2 creado por un escritor, músico, pintor, dramaturgo y jurista alemán llamado Ernst Theodor Amadeus Hoffmann3 (1776-1822). Hoffmann, gran admirador de Mozart, cambió su tercer nombre por el del músico austriaco y durante muchos años se ganó la vida como crítico musical,compositor y director de orquesta
Resumo:
BACKGROUND: For free-breathing cardiovascular magnetic resonance (CMR), the self-navigation technique recently emerged, which is expected to deliver high-quality data with a high success rate. The purpose of this study was to test the hypothesis that self-navigated 3D-CMR enables the reliable assessment of cardiovascular anatomy in patients with congenital heart disease (CHD) and to define factors that affect image quality. METHODS: CHD patients ≥2 years-old and referred for CMR for initial assessment or for a follow-up study were included to undergo a free-breathing self-navigated 3D CMR at 1.5T. Performance criteria were: correct description of cardiac segmental anatomy, overall image quality, coronary artery visibility, and reproducibility of great vessels diameter measurements. Factors associated with insufficient image quality were identified using multivariate logistic regression. RESULTS: Self-navigated CMR was performed in 105 patients (55% male, 23 ± 12y). Correct segmental description was achieved in 93% and 96% for observer 1 and 2, respectively. Diagnostic quality was obtained in 90% of examinations, and it increased to 94% if contrast-enhanced. Left anterior descending, circumflex, and right coronary arteries were visualized in 93%, 87% and 98%, respectively. Younger age, higher heart rate, lower ejection fraction, and lack of contrast medium were independently associated with reduced image quality. However, a similar rate of diagnostic image quality was obtained in children and adults. CONCLUSION: In patients with CHD, self-navigated free-breathing CMR provides high-resolution 3D visualization of the heart and great vessels with excellent robustness.
Resumo:
Se presenta el mapa gravimétrico de la Cubeta Alavesa, donde se pueden localizar de forma clara los diapiros salinos aflorantes en la misma, y también otras estructuras también diapíricas situadas a mayor profundidad. Se ha modelizado en 3D, mediante dos técnicas gravimétricas diferentes, el diapiro de Salinas de Añana. El cual presenta una gran extensión en superficie pero que en cambio no se proyecta de la misma manera en profundidad, habiéndose detectado la presencia de una extensión lateral u overghang hacia el SW.
Resumo:
Tämä diplomityö on selvitystyö mittakuvien ja kolmiulotteisten CAD-mallien tuottamisesta. Mittakuvat ja 3D-CAD-mallit halutaan Neles-tuotemerkin omaaville tuotteille. Olennaisena osana työssä on tuotetiedonhallintajärjestelmä AtonPDM, koska mittakuvia ja malleja toivottaisiin hallittavan AtonPDM-järjestelmällä. Työ tehdään Metso Automationin (MA) Flow Control (FC) –liiketoimintalinjalle. Nykyiset mittakuvat aiheuttavat ongelmia sekä MA:ssa että asiakkaille. MA:ssa mittakuvien tekeminen kestää kauemmin kuin asiakas toivoisi. Nykyisen mittakuvaohjelmiston riittämättömät ominaisuudet aiheuttavat lisätyötä mittakuvien valmistuksessa. Asiakkaille mittakuvien viivästyminen on suunnittelua hidastava tekijä. Mittakuvissa olevat virheet ja puutteet vaikeuttavat asiakkaan suunnittelutyötä ja saattavat päästä läpi tarkatuksien myös loppusuunnitelmiin, jolloin seurauksena voi olla rahallisia menetyksiä. Tämän päivän putkistosuunnittelu hoidetaan suurimmaksi osaksi 3D-CADohjelmistoilla. Suunnittelua helpotetaan ja nopeutetaan valmiilla komponenttien 3Dmalleilla, joihin on liitetty tuotetietoa. Työssä on haastateltu MA:n henkilökuntaa, CAD-järjestelmien toimittajia ja asiakkaita. Haastattelut ovat työn tärkein tiedonlähde. Teoriatietoa on selvitetty kirjoista, lehdistä ja internetistä. Teoriaosiossa käydään läpi tuotetiedonhallinta (Product Data Management, PDM), tietokanta ja parametrinen mallintaminen. Työn lopputuloksena on pyritty saamaan kuvaus siitä miten tuotetaan 3D-CAD-mallit ja mittakuvat Neles-tuotteista käyttäen tiedonlähteenä AtonPDM:ää ja millaisia 3Dmallien ja mittakuvien tulee olla. Malleja ja mittakuvia tuottavaan järjestelmään on etsitty ratkaisuja CAD-ohjelmistoista. Ratkaisuja on verrattu keskenään ominaisuuksien, joustavuuden ja AtonPDM yhteensopivuuden perusteella.