689 resultados para quality index
Resumo:
Routine assessment of health-related quality of life (HRQoL) can be time consuming and burdensome for a person with stroke. Therefore the aim of this study was to develop and test a brief instrument for assessing HRQoL among people with stroke. The Quality of Life after Stroke Scale (QLASS) was constructed from items within the Quality of Life Index-Stroke Version and the Chronic Respiratory Disease Questionnaire. It was administered to 92 people with stroke at three points in time: immediately after discharge from hospital, 6 months and 12 months later. Results suggest that the QLASS has 19 items which represent three factors: emotional functioning, mastery and fatigue which correlate with valid measures of health status and activities of daily living. The QLASS is proposed as a brief, valid HRQoL tool for use among people with stroke.
The quality of reporting of diagnostic accuracy studies in glaucoma using scanning laser polarimetry
Resumo:
PURPOSE: Scanning laser polarimetry (SLP) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the SLP for diagnosing glaucoma. METHODS: A validated Medline and hand search of English-language articles reporting on measures of diagnostic accuracy of the SLP for glaucoma was performed. Two reviewers independently selected and appraised the manuscripts. The Standards for Reporting of Diagnostic Accuracy (STARD) checklist was used to evaluate the quality of each publication. RESULTS: A total of 47 papers were identified of which the first 10 (from 1997 to 2000) and the last 10 articles (from 2004 to 2005) were appraised. Interobserver rating agreement of STARD items was high (85.5% agreement, ?=0.796). The number of STARD items properly reported ranged from 3/25 to 19/25. Only a quarter of studies (5/20) explicitly reported more than half of the STARD items. Important aspects of the methodology were often missing such as participant sampling (reported in 40% of manuscripts), masking of the readers of the index test and reference standard (reported in 20% of manuscripts), and estimation of uncertainty (eg, 95% confidence intervals, reported in 25% of manuscripts). There was a slight increase in the number of STARD items reported with time. CONCLUSIONS: The quality of reporting of diagnostic accuracy tests for glaucoma with SLP is suboptimal. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies. © 2007 Lippincott Williams & Wilkins, Inc.
Resumo:
RATIONALE: In bronchiectasis there is a need for improved markers of lung function to determine disease severity and response to therapy.
OBJECTIVES: To assess whether the lung clearance index is a repeatable and more sensitive indicator of computed tomography (CT) scan abnormalities than spirometry in bronchiectasis.
METHODS: Thirty patients with stable bronchiectasis were recruited and lung clearance index, spirometry, and health-related quality of life measures were assessed on two occasions, 2 weeks apart when stable (study 1). A separate group of 60 patients with stable bronchiectasis was studied on a single visit with the same measurements and a CT scan (study 2).
MEASUREMENTS AND MAIN RESULTS: In study 1, the intervisit intraclass correlation coefficient for the lung clearance index was 0.94 (95% confidence interval, 0.89 to 0.97; P < 0.001). In study 2, the mean age was 62 (10) years, FEV1 76.5% predicted (18.9), lung clearance index 9.1 (2.0), and total CT score 14.1 (10.2)%. The lung clearance index was abnormal in 53 of 60 patients (88%) and FEV1 was abnormal in 37 of 60 patients (62%). FEV1 negatively correlated with the lung clearance index (r = -0.51, P < 0.0001). Across CT scores, there was a relationship with the lung clearance index, with little evidence of an effect of FEV1. There were no significant associations between the lung clearance index or FEV1 and health-related quality of life.
CONCLUSIONS: The lung clearance index is repeatable and a more sensitive measure than FEV1 in the detection of abnormalities demonstrated on CT scan. The lung clearance index has the potential to be a useful clinical and research tool in patients with bronchiectasis.
Resumo:
Clinical clerks learn more than they are taught and not all they learn can be measured. As a result, curriculum leaders evaluate clinical educational environments. The quantitative Dundee Ready Environment Measure (DREEM) is a de facto standard for that purpose. Its 50 items and 5 subscales were developed by consensus. Reasoning that an instrument would perform best if it were underpinned by a clearly conceptualized link between environment and learning as well as psychometric evidence, we developed the mixed methods Manchester Clinical Placement Index (MCPI), eliminated redundant items, and published validity evidence for its 8 item and 2 subscale structure. Here, we set out to compare MCPI with DREEM. 104 students on full-time clinical placements completed both measures three times during a single academic year. There was good agreement and at least as good discrimination between placements with the smaller MCPI. Total MCPI scores and the mean score of its 5-item learning environment subscale allowed ten raters to distinguish between the quality of educational environments. Twenty raters were needed for the 3-item MCPI training subscale and the DREEM scale and its subscales. MCPI compares favourably with DREEM in that one-sixth the number of items perform at least as well psychometrically, it provides formative free text data, and it is founded on the widely shared assumption that communities of practice make good learning environments.
Resumo:
Background: Systematic assessment of severe asthma can be used to confirm the diagnosis, identify comorbidities, and address adherence to therapy. However, the prospective usefulness of this approach is yet to be established. The objective of this study was to determine whether the systematic assessment of severe asthma is associated with improved quality of life (QoL) and health-care use and, using prospective data collection, to compare relevant outcomes in patients referred with severe asthma to specialist centers across the United Kingdom. Methods: Data from the National Registry for dedicated UK Difficult Asthma Services were used to compare patient demographics, disease characteristics, and health-care use between initial assessment and a median follow-up of 286 days. Results: The study population consisted of 346 patients with severe asthma. At follow-up, there were significant reductions in health-care use in terms of primary care or ED visits (66.4% vs 87.8%, P < .0001) and hospital admissions (38% vs 48%, P = .0004). Although no difference was noted in terms of those requiring maintenance oral corticosteroids, there was a reduction in steroid dose (10 mg [8-20 mg] vs 15 mg [10-20 mg], P = .003), and fewer subjects required short-burst steroids (77.4% vs 90.8%, P = .01). Significant improvements were seen in QoL and control using the Asthma Quality of Life Questionnaire and the Asthma Control Questionnaire. Conclusions: To our knowledge, this is the first time that a prospective study has shown that a systematic assessment at a dedicated severe asthma center is associated with improved QoL and asthma control and a reduction in health-care use and oral steroid burden.
Resumo:
Esta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contrastedetalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.
Resumo:
Aphasia is a chronic acquired communication disorder that may change people with aphasia (PWA) and their caregivers’ lives for ever. Social and emotional changes are frequently reported by both, although the impact of these changes in quality of life (QOL) needs further research. This study identifies predictors and variables that influence PWA’s and their caregivers’ QOL and social relationships (SR). A cross-sectional descriptive, correlational and comparative study was undertaken with 255 individuals from Portuguese general population (mean age 43 years, range 25-84 years; 148 females, 107 males), 25 PWA (mean age 54 years, range 20-71; 12 females and 13 males), and 25 caregivers (mean age 51 years, range 26-73; 17 females and 8 males). All the participants completed the World Health Quality of Life Bref instrument, the SR domain of the World Health Organization Quality of Life – 100 scale, and the Center for Epidemiologic Studies Depression Scale. Participants with aphasia completed the Lisbon Aphasia Assessment Battery, Barthel Index, Frenchay Activities Index, Communication Disability Profile and the Modified Mini-Mental State which evaluated language disability, aphasia coefficient, activities, participation and cognition. In addition, caregivers completed the Carers’ Assessment of Managing Index to assess coping strategies. PWA and their caregivers are less satisfied with their QOL and SR than Portuguese general population; whereas PWA have the worse QOL and SR. Thus, aphasia seems to impact negatively in their QOL and SR. Emotional status has great importance for QOL and SR among the three groups. PWA’s activities and participation have great impact in both PWA’s and caregivers’ QOL and SR. Additionally, emotional status and participation are the best predictors of PWA’s QOL. Along with these two variables, activities of the PWA are the best predictors of caregivers’ QOL. Participation is the best predictor of PWA’s SR; emotional status and number of cohabitants are best predictors for caregivers’ SR. Aphasia assessment and intervention should take into account all the factors that influence PWA’s and caregivers’ QOL and SR so the central goal of enhancing it can be achieved. These results are important for identifying and planning support needs and are useful in the orientation of the activities carried out by the service providers allowing the adjustment of health programs and policies based on people’s real life needs.
Resumo:
Dissertação de mestrado, Aquacultura, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2011
Resumo:
Objective: Quality of life was measured using the EQ-5D index for Portugal and a Self-Assessed Ranking of Health (SARH) to understand which patients suffer the most decrease in quality of life: diabetics or hypertensive. Method: Using the National Health Survey (NHS), two analyses were conducted on 5649 respondents. The EQ-5D index was calculated by matching questions in the NHS with its dimensions. The SARH was calculated based on a specific question in the NHS. Results: Differences between diseases do not occur using the EQ-5D index. Using the SARH, type 1 diabetics suffer the most while hypertensive suffers the least.
Resumo:
BACKGROUND: The WOSI (Western Ontario Shoulder Instability Index) is a self-administered quality of life questionnaire designed to be used as a primary outcome measure in clinical trials on shoulder instability, as well as to measure the effect of an intervention on any particular patient. It is validated and is reliable and sensitive. As it is designed to measure subjective outcome, it is important that translation should be methodologically rigorous, as it is subject to both linguistic and cultural interpretation. OBJECTIVE: To produce a French language version of the WOSI that is culturally adapted to both European and North American French-speaking populations. MATERIALS AND METHODS: A validated protocol was used to create a French language WOSI questionnaire (WOSI-Fr) that would be culturally acceptable for both European and North American French-speaking populations. Reliability and responsiveness analyses were carried out, and the WOSI-Fr was compared to the F-QuickDASH-D/S (Disability of the Arm, Shoulder and Hand-French translation), and Walch-Duplay scores. RESULTS: A French language version of the WOSI (WOSI-Fr) was accepted by a multinational committee. The WOSI-Fr was then validated using a total of 144 native French-speaking subjects from Canada and Switzerland. Comparison of results on two WOSI-Fr questionnaires completed at a mean interval of 16 days showed that the WOSI-Fr had strong reliability, with a Pearson and interclass correlation of r=0.85 (P=0.01) and ICC=0.84 [95% CI=0.78-0.88]. Responsiveness, at a mean 378.9 days after surgical intervention, showed strong correlation with that of the F-QuickDASH-D/S, with r=0.67 (P<0.01). Moreover, a standardized response means analysis to calculate effect size for both the WOSI-Fr and the F-QuickDASH-D/S showed that the WOSI-Fr had a significantly greater ability to detect change (SRM 1.55 versus 0.87 for the WOSI-Fr and F-QuickDASH-D/S respectively, P<0.01). The WOSI-Fr showed fair correlation with the Walch-Duplay. DISCUSSION: A French-language translation of the WOSI questionnaire was created and validated for use in both Canadian and Swiss French-speaking populations. This questionnaire will facilitate outcome assessment in French-speaking settings, collaboration in multinational studies and comparison between studies performed in different countries. TYPE OF STUDY: Multicenter cohort study. LEVEL OF EVIDENCE: II.
Resumo:
Background a nd Aims: T he international E EsAI study g roupis currently developing the first activity index (EEsAI) specificfor Eosinophilic Esophagitis (EoE). Goal: To develop, evaluateand validate the EEsAI.Methods: T he d evelopment comprises three phases: 1.Selection of candidate items; 2. Evaluation of the activity indexin a f irst patient cohort; and 3. V alidation in a s econd EoEpatient cohort. Focus group interviews with patients were usedin p hase 1 to generate p atient r eported outcomes ( PRO)according to guidelines o f regulatory authorities ( FDA andEMA), whereas the section of biologic items was developed byDelphi r ounds of i nternational E oE experts from E urope andNorth America.Results: The EEsAI has a modular composition to assess thefollowing components o f EoE activity: p atient reportedoutcomes, endoscopic activity, histologic activity, laboratoryactivity, a nd quality of life. D efinitions f or all aspects o fendoscopic and histologic appearance were established byconsensus rounds among EoE experts. Symptom assessmenttools were created that take into account d ifferent foodconsistencies as w ell as f ood avoidance and specificprocessing strategies. T he EEsAI is evaluated in a c ohort ofadult EoE patients since March 2011.Conclusions: After successful validation, the EEsAI will allowto standardize outcome assessment in E oE t rials which w illlikely lead to its wide applicability.
Resumo:
The inverse relationship between arboreal lichen species richness and sulphur dioxide in ambient air has been thoroughly documented in the literature. Previous work in southern Ontario has shown that lichen bioindication can identify areas of potential concern regarding air quality. The EMAN suite of l i chens was applied in the City of Samia by surveying 458 Sugar Maple trees, in order to test the applicability of lichen bioindication under conditions of high mean S02 levels and high species richness values. The results of the survey were explored using Geographic Information Systems. A spatial relationship between lichen community variables, the Bluewater Bridge and the highway was identified. Lichen species richness, lichen percent cover and Index of Atmospheric Purity values were higher along the bridge and highway. No strong gradients were found between other known pollution sources and no lichen deserts were identified. The most common community grouping consisted of Physcia millegrana Degel, Candelaria concolor (Dicks) B. Stein, Physcia aipolia (Ehrh ex Humb.) Furnrohr; all of which are known nitrophytes. The relationship between substrate pH and lichen species richness was examined. Sites with a known source of anthropogenic chemical contamination were found to have a correlation of l=0.8 between lichen species richness and pH. The inverse was found for sites with no known source of contamination with a correlation of r 2 =-0.72. The findings suggest that species richness may be influenced by altering substrate pH which promotes the growth of nitrophytic species capable of tolerating high S02 levels.
Association between diet quality and metabolic syndrome in overweight and obese postmenopausal women
Resumo:
Résumé Objectifs : Le syndrome métabolique (MetS) est un ensemble de composantes (obésité, résistance à l'insuline, intolérance au glucose, dyslipidémie, hypertension) qui sont associées à une augmentation du risque de diabète de type 2 et de maladies cardiovasculaires. Aux États-Unis, la fréquence du MetS atteint des proportions épidémiques avec une prévalence de 25% de la population. Les études nutritionnelles traditionnelles se sont concentrées sur l’effet d’un nutriment alors que les études plus récentes ont déterminé l’effet global de la qualité alimentaire sur les facteurs de risque. Cependant, peu d'études ont examiné la relation entre la qualité alimentaire et le MetS. Objectif: Déterminer l'association entre la qualité alimentaire et le MetS et ses composantes. Méthodes: La présence du MetS a été déterminée chez 88 femmes post-ménopausées en surpoids ou obèses, selon la définition du National Cholesterol Education Program Adult treatment Panel III alors que la qualité alimentaire a été évaluée selon le Healthy Eating Index (HEI). La sensibilité à l’insuline, la composition corporelle et le métabolisme énergétique ont été mesurés. Résultats: Le HEI corrélait négativement avec la plupart des mesures de masse grasse et du poids mais pas avec la sensibilité à l'insuline, l’hypertension et la plupart des marqueurs lipidiques. Cependant, l’HEI corrélait positivement avec LDL-C/ApoB et négativement avec le métabolisme énergétique. Conclusion: Les résultats démontrent que l’HEI est associé avec les mesures de gras corporel et la grosseur des LDL. Mots clés: Obésité, qualité alimentaire, métabolisme lipidique, syndrome métabolique.
Resumo:
The service quality of any sector has two major aspects namely technical and functional. Technical quality can be attained by maintaining technical specification as decided by the organization. Functional quality refers to the manner which service is delivered to customer which can be assessed by the customer feed backs. A field survey was conducted based on the management tool SERVQUAL, by designing 28 constructs under 7 dimensions of service quality. Stratified sampling techniques were used to get 336 valid responses and the gap scores of expectations and perceptions are analyzed using statistical techniques to identify the weakest dimension. To assess the technical aspects of availability six months live outage data of base transceiver were collected. The statistical and exploratory techniques were used to model the network performance. The failure patterns have been modeled in competing risk models and probability distribution of service outage and restorations were parameterized. Since the availability of network is a function of the reliability and maintainability of the network elements, any service provider who wishes to keep up their service level agreements on availability should be aware of the variability of these elements and its effects on interactions. The availability variations were studied by designing a discrete time event simulation model with probabilistic input parameters. The probabilistic distribution parameters arrived from live data analysis was used to design experiments to define the availability domain of the network under consideration. The availability domain can be used as a reference for planning and implementing maintenance activities. A new metric is proposed which incorporates a consistency index along with key service parameters that can be used to compare the performance of different service providers. The developed tool can be used for reliability analysis of mobile communication systems and assumes greater significance in the wake of mobile portability facility. It is also possible to have a relative measure of the effectiveness of different service providers.
Resumo:
Customer satisfaction and retention are key issues for organizations in today’s competitive market place. As such, much research and revenue has been invested in developing accurate ways of assessing consumer satisfaction at both the macro (national) and micro (organizational) level, facilitating comparisons in performance both within and between industries. Since the instigation of the national customer satisfaction indices (CSI), partial least squares (PLS) has been used to estimate the CSI models in preference to structural equation models (SEM) because they do not rely on strict assumptions about the data. However, this choice was based upon some misconceptions about the use of SEM’s and does not take into consideration more recent advances in SEM, including estimation methods that are robust to non-normality and missing data. In this paper, both SEM and PLS approaches were compared by evaluating perceptions of the Isle of Man Post Office Products and Customer service using a CSI format. The new robust SEM procedures were found to be advantageous over PLS. Product quality was found to be the only driver of customer satisfaction, while image and satisfaction were the only predictors of loyalty, thus arguing for the specificity of postal services