983 resultados para prosthesis implant


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infection is one of the most serious complications after total knee arthroplasty (TKA). The current incidence of prosthetic knee infection is 1-3%, depending on the series(.) For treatment and control to be more cost effective, multidisciplinary groups made up of professionals from different specialities who can work together to eradicate these kinds of infections need to be assembled. About the microbiology, Staphylococcus aureus and coagulase-negative staphylococcus were among the most frequent microorganisms involved (74%). Anamnesis and clinical examination are of primary importance in order to determine whether the problem may point to a possible acute septic complication. The first diagnosis may then be supported by increased CRP and ESR levels. The surgical treatment for a chronic prosthetic knee infection has been perfectly defined and standardized, and consists in a two-stage implant revision process. In contrast, the treatment for acute prosthetic knee infection is currently under debate. Considering the different surgical techniques that already exist, surgical debridement with conservation of the prosthesis and polythene revision appears to be an attractive option for both surgeon and patient, as it is less aggressive than the two-stage revision process and has lower initial costs. The different results obtained from this technique, along with prognosis factors and conclusions to keep in mind when it is indicated for an acute prosthetic infection, whether post-operative or haematogenous, will be analysed by the authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of load-bearing osseous implant with desired mechanical and surface properties in order to promote incorporation with bone and to eliminate risk of bone resorption and implant failure is a very challenging task. Bone formation and resoption processes depend on the mechanical environment. Certain stress/strain conditions are required to promote new bone growth and to prevent bone mass loss. Conventional metallic implants with high stiffness carry most of the load and the surrounding bone becomes virtually unloaded and inactive. Fibre-reinforced composites offer an interesting alternative to metallic implants, because their mechanical properties can be tailored to be equal to those of bone, by the careful selection of matrix polymer, type of fibres, fibre volume fraction, orientation and length. Successful load transfer at bone-implant interface requires proper fixation between the bone and implant. One promising method to promote fixation is to prepare implants with porous surface. Bone ingrowth into porous surface structure stabilises the system and improves clinical success of the implant. The experimental part of this work was focused on polymethyl methacrylate (PMMA) -based composites with dense load-bearing core and porous surface. Three-dimensionally randomly orientated chopped glass fibres were used to reinforce the composite. A method to fabricate those composites was developed by a solvent treatment technique and some characterisations concerning the functionality of the surface structure were made in vitro and in vivo. Scanning electron microscope observations revealed that the pore size and interconnective porous architecture of the surface layer of the fibre-reinforced composite (FRC) could be optimal for bone ingrowth. Microhardness measurements showed that the solvent treatment did not have an effect on the mechanical properties of the load-bearing core. A push-out test, using dental stone as a bone model material, revealed that short glass fibre-reinforced porous surface layer is strong enough to carry load. Unreacted monomers can cause the chemical necrosis of the tissue, but the levels of leachable resisidual monomers were considerably lower than those found in chemically cured fibre-reinforced dentures and in modified acrylic bone cements. Animal experiments proved that surface porous FRC implant can enhance fixation between bone and FRC. New bone ingrowth into the pores was detected and strong interlocking between bone and the implant was achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cranial bone reconstructions are necessary for correcting large skull bone defects due to trauma, tumors, infections and craniotomies. Traditional synthetic implant materials include solid or mesh titanium, various plastics and ceramics. Recently, biostable glass-fiber reinforced composites (FRC), which are based on bifunctional methacrylate resin, were introduced as novel implant solution. FRCs were originally developed and clinically used in dental applications. As a result of further in vitro and in vivo testing, these composites were also approved for clinical use in cranial surgery. To date, reconstructions of large bone defects were performed in 35 patients. This thesis is dedicated to the development of a novel FRC-based implant for cranial reconstructions. The proposed multi-component implant consists of three main parts: (i) porous FRC structure; (ii) bioactive glass granules embedded between FRC layers and (iii) a silver-polysaccharide nanocomposite coating. The porosity of the FRC structure should allow bone ingrowth. Bioactive glass as an osteopromotive material is expected to stimulate the formation of new bone. The polysaccharide coating is expected to prevent bacterial colonization of the implant. The FRC implants developed in this study are based on the porous network of randomly-oriented E-glass fibers bound together by non-resorbable photopolymerizable methacrylate resin. These structures had a total porosity of 10–70 volume %, of which > 70% were open pores. The pore sizes > 100 μm were in the biologically-relevant range (50-400 μm), which is essential for vascularization and bone ingrowth. Bone ingrowth into these structures was simulated by imbedding of porous FRC specimens in gypsum. Results of push-out tests indicated the increase in the shear strength and fracture toughness of the interface with the increase in the total porosity of FRC specimens. The osteopromotive effect of bioactive glass is based on its dissolution in the physiological environment. Here, calcium and phosphate ions, released from the glass, precipitated on the glass surface and its proximity (the FRC) and formed bone-like apatite. The biomineralization of the FRC structure, due to the bioactive glass reactions, was studied in Simulated Body Fluid (SBF) in static and dynamic conditions. An antimicrobial, non-cytotoxic polysaccharide coating, containing silver nanoparticles, was obtained through strong electrostatic interactions with the surface of FRC. In in vitro conditions the lactose-modified chitosan (chitlac) coating showed no signs of degradation within seven days of exposure to lysozyme or one day to hydrogen peroxide (H2O2). The antimicrobial efficacy of the coating was tested against Staphylococcus aureus and Pseudomonas aeruginosa. The contact-active coating had an excellent short time antimicrobial effect. The coating neither affected the initial adhesion of microorganisms to the implant surface nor the biofilm formation after 24 h and 72 h of incubation. Silver ions released to the aqueous environment led to a reduction of bacterial growth in the culture medium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fiber-reinforced composites (FRCs) are a new group of non-metallic biomaterials showing a growing popularity in many dental and medical applications. As an oral implant material, FRC is biocompatible in bone tissue environment. Soft tissue integration to FRC polymer material is unclear. This series of in vitro studies aimed at evaluating unidirectional E-glass FRC polymer in terms of mechanical, chemical, and biological properties in an attempt to develop a new non-metallic oral implant abutment alternative. Two different types of substrates were investigated: (a) Plain polymer (BisGMA 50%–TEGDMA 50%) and (b) Unidirectional FRC. The mechanical behavior of high fiber-density FRCs was assessed using a three-point bending test. Surface characterization was performed using scanning electron and spinning disk confocal microscopes. The surface wettability/energy was determined using sessile drop method. The blood response, including blood-clotting ability and platelet morphology was evaluated. Human gingival fibroblast cell responses - adhesion kinetics, adhesion strength, and proliferation activity - were studied in cell culture environment using routine test conditions. A novel tissue culture method was developed and used to evaluate porcine gingival tissue graft attachment and growth on the experimental composite implants. The analysis of the mechanical properties showed that there is a direct proportionality in the relationship between E-glass fiber volume fraction and toughness, modulus of elasticity, and load bearing capacity; however, flexural strength did not show significant improvement when high fiber-density FRC is used. FRCs showed moderate hydrophilic properties owing to the presence of exposed glass fibers on the polymer surface. Blood-clotting time was shorter on FRC substrates than on plain polymer. The FRC substrates also showed higher platelet activation state than plain polymer substrates. Fibroblast cell adhesion strength and proliferation rate were highly pronounced on FRCs. A tissue culture study revealed that gingival epithelium and connective tissue established an immediate close contact with both plain polymer and FRC implants. However, FRC seemed to guide epithelial migration outwards from the tissue/implant interface. Due to the anisotropic and hydrophilic nature of FRC, it can be concluded that this material enhances biological events related with soft tissue integration on oral implant surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this prospective study was to evaluate the efficacy and complications of the use of an intraocular sustained-release ganciclovir implant for the treatment of active cytomegalovirus (CMV) retinitis in AIDS patients. Thirty-nine eyes of 26 patients were submitted to ocular surgery. All patients underwent complete ocular examination before and after surgery. The surgical procedure was always done under local anesthesia using the same technique. The mean time for the surgical procedure was 20 min (range, 15 to 30 min). The average follow-up period was 3.7 months. Of all patient, only 4 presented recurrence of retinitis after 8, 8, 9 and 2 months, respectively. Three of them received a successful second implant. All 39 eyes of the 26 patients presented healing of retinitis as shown by clinical improvement evaluated by indirect binocular ophthalmoscopy and retinography. Retinitis healed within a period of 4 to 6 weeks in all patients, with clinical regression signs from the third week on. Six (15.4%) eyes developed retinal detachment. None of the patients developed CMV retinitis in the contralateral eye. The intraocular implant proved to be effective in controlling the progression of retinitis for a period of up to 8 months even in patients for whom systemic therapy with either ganciclovir or foscarnet or both had failed. The intraocular sustained-release ganciclovir implant proved to be a safe new procedure for the treatment of CMV retinitis, avoiding the systemic side effects caused by the intravenous medications and improving the quality of life of the patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intracranial aneurysmal subarachnoid hemorrhage (aSAH) is a life-threatening condition requiring immediate neurocritical care. A ruptured aneurysm must be isolated from arterial circulation to prevent rebleeding. Open surgical clipping of the neck of the aneurysm or intra-arterial filling of the aneurysm sack with platinum coils are major treatment strategies in an acute phase. About 40% of the patients suffering from aSAH die within a year of the bleeding despite the intensive treatment. After aSAH, the patient may develop a serious complication called vasospasm. Major risk for the vasospasm takes place at days 5–14 after the primary bleeding. In vasospasm, cerebral arteries contract uncontrollably causing brain ischemia that may lead to death. Nimodipine (NDP) is used to treat of vasospasm and it is administrated intravenously or orally every four hours for 21 days. NDP treatment has been scientifically proven to improve patients’ clinical outcome. The therapeutic effect of L-type calcium channel blocker NDP is due to the ability to dilate cerebral arteries. In addition to vasodilatation, recent research has shown the pleiotropic effect of NDP such as inhibition of neuronal apoptosis and inhibition of microthrombi formation. Indeed, NDP inhibits cortical spreading ischemia. Knowledge of the pathophysiology of the vasospasm has evolved in recent years to a complex entity of early brain injury, secondary injuries and cortical spreading ischemia, instead of being pure intracranial vessel spasm. High NDP levels are beneficial since they protect neurons and inhibit the cortical spreading ischemia. One of the drawbacks of the intravenous or oral administration of NPD is systemic hypotension, which is harmful particularly when the brain is injured. Maximizing the beneficial effects and avoiding systemic hypotension of NDP, we developed a sustained release biodegradable NDP implant that was surgically positioned in the basal cistern of animal models (dog and pig). Higher concentrations were achieved locally and lower concentrations systemically. Using this treatment approach in humans, it may be possible to reduce incidence of harmful hypotension and potentiate beneficial effects of NDP on neurons. Intracellular calcium regulation has a pivotal role in brain plasticity. NDP blocks L-type calcium channels in neurons, substantially decreasing intracellular calcium levels. Thus, we were interested in how NDP affects brain plasticity and tested the hypothesis in a mouse model. We found that NDP activates Brain-derived neurotrophic factor (BDNF) receptor TrkB and its downstream signaling in a reminiscent of antidepressant drugs. In contrast to antidepressant drugs, NDP activates Akt, a major survival-promoting factor. Our group’s previous findings demonstrate that long-term antidepressant treatment reactivates developmental-type of plasticity mechanisms in the adult brain, which allows the remodeling of neuronal networks if combined with appropriate rehabilitation. It seems that NDP has antidepressant-like properties and it is able to induce neuronal plasticity. In general, drug induced neuronal plasticity has a huge potential in neurorehabilitation and more studies are warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methods to optimize healing through dietary strategies present an attractive option for patients, such that healing from delicate oral surgeries occurs as optimally as possible with minimal patient-meditated complications through improper food choices. This review discusses findings from studies that have investigated the role of diet, either whole foods or individual dietary components, on periodontal health and their potential role in wound healing after periodontal surgery. To date, research in this area has largely focused on foods or individual dietary components that may attenuate inflammation or oxidant stress, or foster de novo bone formation. These studies suggest that a wide variety of dietary components, including macronutrients and micronutrients, are integral for optimal periodontal health and have the potential to accelerate oral wound healing after periodontal procedures. Moreover, this review provides guidance regarding dietary considerations that may help a patient achieve the best possible outcome after a periodontal procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de recherche

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cette thèse examine le développement du langage des enfants sourds qui ont reçu un implant cochléaire (IC) en bas âge. Une première étude rapporte une revue systématique qui avait pour but d’évaluer les connaissances actuelles concernant le développement du vocabulaire et de la grammaire chez les enfants qui ont reçu un IC avant l’âge de trois ans. Vingt-huit études ont été sélectionnées; une analyse descriptive de même qu’une méta-analyse ont été effectuées séparément pour chaque aspect du langage évalué (vocabulaire et grammaire, aspect réceptif et expressif). Au résultat, en dépit de la variabilité observée dans les études, il appert que l’implant cochléaire influence positivement le développement langagier; toutefois, seule une minorité de participants aux études a atteint des niveaux de langage comparables à ceux d’enfants entendants de même âge chronologique. La majorité des enfants continuent de présenter divers degrés de retard de langage, tant au plan réceptif qu’expressif, et ce, après jusqu’à cinq années de port de l’appareil. Les résultats suggèrent aussi, malgré la variabilité observée dans les études, que les bénéfices langagiers sont influencés par le fait de recevoir l’implant à deux ans plutôt qu’à trois ans. À partir des tendances retrouvées dans la littérature, les habiletés de vocabulaire et de grammaire chez 27 enfants qui ont reçu l’implant cochléaire en bas âge (entre 8 et 28 mois) ont été comparées avec celles d’un groupe d’enfants entendants, en utilisant des outils d’évaluation standardisés. Alors que les résultats de groupe montrent que les enfants qui reçoivent un IC autour de l’âge de deux ans atteignent des niveaux de langage dans les limites de la normale, les résultats individuels d’un sous-groupe formé de enfants les plus âgés font état de quatre profils de développement, soit des niveaux de langage dans les limites de la normale pour l’ensemble des composantes, un retard généralisé à l’ensemble des composantes, des habiletés lexicales dans la norme assorti d’un retard morphosyntaxique et enfin un profil atypique montrant des disparités importantes à travers les composantes du langage. Dans trois des quatre profils, la compréhension des phrases était particulièrement faible. Ces résultats suggèrent que le fait de recevoir un implant cochléaire entre l’âge d’un et deux ans ne garantit pas l’atteinte de niveaux de langage dans les limites de la normale malgré une expérience de port de l’appareil d’une durée appréciable. Une étape antérieure du développement linguistique a été examinée de plus près dans la troisième étude. La taille et la composition du vocabulaire expressif de onze enfants ayant reçu un IC à un âge moyen de 15 mois ont été comparées à celles de l’échantillon d’enfants entendants ayant servi à établir les normes en français québécois pour le questionnaire Mots et énoncés des Inventaires MacArthur-Bates du développement de la communication (IMBDC). Les scores d’âge équivalent selon la taille totale du vocabulaire des enfants avec IC étaient supérieurs à l’âge auditif (correspondant à la durée de port de l’appareil) mais inférieurs à l’âge chronologique. La représentation grammaticale en fonction de la taille du vocabulaire des enfants avec IC suit la tendance observée dans la norme. Ces résultats suggèrent que le profil lexical des enfants avec implant est très similaire à celui des enfants entendants lorsque le nombre total de mots acquis est le même. Les résultats de cette thèse suggèrent que l’implant peut, de manière générale, avoir un effet « normalisant » sur le langage ; toutefois, il semble que l’amélioration de l’accès auditif ne suffise pas pour rattraper à coup sûr le niveau de langage des pairs entendants dans l’ensemble des composantes du langage. Alors que les habiletés lexicales se rapprochent du profil typique, les habiletés de compréhension morphosyntaxique sont fortement atteintes chez une majorité d’enfants, suggérant un profil apparenté à un trouble de langage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La supériorité des prothèses mandibulaires retenues par deux implants (IODs) sur les prothèses conventionnelles (CDs) nécessitent d’être éclaircies notamment en rapport à leur influence sur la qualité de vie reliée à la santé bucco-dentaire (OHRQoL) ainsi que sur la stabilité de cet effet de traitement. De plus, l’influence des facteurs psychologiques, tel que le sens de cohérence (SOC), sur l’effet de traitement reste encore inconnue. Le but de cette étude est de déterminer l’amplitude de l’influence du port des IODs et des CDs sur l’OHRQoL et d’évaluer la stabilité de l’effet de traitement dans le temps, tout en prenant en considération le niveau du SOC. MÉTHODOLOGIE: Des participants édentés (n=172, âge moyen 71, SD = 4.5) ayant reçu des CDs ou des IODs ont été suivis sur une période de deux ans. L’OHRQoL a été évaluée à l’aide du questionnaire « Oral Health Impact Profile (OHIP -20) » et ce avant le traitement et à chacun des deux suivis. Le SOC a été évalué à l’aide du questionnaire « The Orientation to Life (SOC -13) » à chacun des deux suivis. Des analyses statistiques ont été effectuées pour évaluer les différences intra et entre groupes (analyses statistiques descriptives, bivariées et multivariées). RÉSULTATS: Une amélioration statistiquement significative de l’OHRQoL entre les statuts avant et après traitement a été notée dans les deux groupes (Wilks’s Lambda = 0.473, F (1,151) = 157.31, p < 0.0001). L’amplitude de l’effet du traitement IOD est 1.5 fois plus grande que celle du traitement CD. Ces résultats ont été stables pendant les deux années d’étude et ils n’ont pas été influencés par le SOC. CONCLUSION: Le traitement IOD amène une meilleure OHRQoL à long terme en comparaison avec le traitement CD et ce sans influence du niveau du SOC. Ces résultats sont cliniquement significatifs et confirment la supériorité des IODs sur les CDs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport d'analyse d'intervention présenté à la Faculté des arts et sciences en vue de l'obtention du grade de Maîtrise ès sciences (M. Sc.) en psychoéducation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nous présenterons le procédé de fabrication, la caractérisation, ainsi qu’un modèle numérique permettant l’optimisation d’un nouveau dispositif permettant d’effectuer des mesures de nanocalorimétrie sur un échantillon de silicium monocristallin. Ce dernier possède entre autre des propriétés thermiques nous permettant d’effectuer des mesures à des températures supérieures à 900 C, avec une résolution meilleure que 16 C. Ceci nous a permis d’étudier la dynamique des défauts induits par implantation ionique dans le silicium monocristallin. Deux comportements différents sont observés dans la germination de la phase amorphe induite par implantation à 10 et 80 keV. Ces résultats ont été confrontés à des simulations Monte-Carlo basées sur le modèle des paires lacunesinterstitiels. La comparaison entre les simulations et les mesures expérimentales ont montré que ce modèle est incomplet car il ne reproduit qualitativement que certaines caractéristiques observées expérimentalement. Des mesures réalisées à partir de -110 C dans le silicium monocristallin et amorphisé implanté avec des ions légers, ont mis en évidence des différences claires entre la relaxation dans le silicium amorphe et le recuit des défauts dans le silicium monocristallin. Deux processus à des énergies d’activation de 0.48 et 0.6 eV ont été observés pour les implantations réalisées dans le silicium monocristallin tandis qu’un relâchement de chaleur uniforme ne révélant qu’un spectre continu d’énergie d’activation a été observé dans le silicium amorphe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’implant cochléaire devient une ressource importante pour contrer la surdité alors qu’il a été démontré qu’une privation auditive précoce ou tardive affecte le développement des systèmes auditif et visuel. Le but des études présentées dans cette thèse est d’évaluer l’impact développemental d’une privation auditive sur les systèmes auditif et visuel. En premier lieu, l’étude du développement chez une population entendante a montré que les systèmes auditif et visuel se développent à des rythmes distincts et qu’ils atteignent leur maturité respective à des âges différents. Ces conclusions suggèrent que les mécanismes qui sous-tendent ces deux systèmes sont différents et que leur développement respectif est indépendant. Aussi, tel qu’observé par une mesure comportementale et électrophysiologique, la discrimination fréquentielle auditive chez les personnes porteuses d’un implant cochléaire est altérée et corrélée aux performances de perception de la parole. Ces deux études suggèrent que suite à une privation auditive, le traitement auditif diffère d’une personne malentendante à une autre, et que ces différences touchent les processus de bas-niveaux, tel que suggéré par la disparité présente dans les performances de discrimination fréquentielle. La dernière étude observe qu’une privation auditive affecte aussi le développement de la modalité visuelle, tel qu’indiqué par une diminution des capacités de discrimination visuelle observée chez des malentendants. Cette indication appuie l’hypothèse qu’un développement normal de chacun des sens est requis pour un développement optimal des autres sens. Globalement, les résultats présentés dans cette thèse suggèrent que les systèmes auditif et visuel se développent de façon distincte, mais demeurent toutefois interreliés. En effet, une privation auditive affecte non seulement le développement des habiletés auditives, mais aussi celui des habiletés visuelles, suggérant une interdépendance entre les deux systèmes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thèse diffusée initialement dans le cadre d'un projet pilote des Presses de l'Université de Montréal/Centre d'édition numérique UdeM (1997-2008) avec l'autorisation de l'auteur.