996 resultados para ocular imaging instruments
Resumo:
Structural connectivity models based on Diffusion Tensor Imaging (DTI) are strongly affected by the technique’s inability to resolve crossing fibres, either intra- or inter-hemispherical connections. Several models have been proposed to address this issue, including an algorithm aiming to resolve crossing fibres which is based on Diffusion Kurtosis Imaging (DKI). This technique is clinically feasible, even when multi-band acquisitions are not available, and compatible with multi-shell acquisition schemes. DKI is an extension of DTI enabling the estimation of diffusion tensor and diffusion kurtosis metrics. In this study we compare the performance of DKI and DTI in performing structural brain connectivity. Six healthy subjects were recruited, aged between 25 and 35 (three females). The MRI experiments were performed using a 3T Siemens Trio with a 32-channel head coil. The scans included a T1-weighted sequence (1mm3), and a DWI with b-values 0, 1000 and 2000 s:mm
Resumo:
The authors report the magnetic resonance imaging diagnostic features in two cases with respectively lumbar epidural hematoma and cavernous hemangioma of the lumbar epidural space. Enhanced MRI T1-weighted scans show a hyperintense signal rim surrounding the vascular lesion. Non-enhanced T2-weighted scans showed hyperintense signal.
Resumo:
PURPOSE: To determine the consequences of the chronic use of systemic corticosteroids in children with juvenile rheumatoid arthritis by means of evaluating osteochondral effects depicted by magnetic resonance imaging. PATIENTS AND METHODS: We reviewed clinical and magnetic resonance imaging findings in 69 children (72 knees) with juvenile rheumatoid arthritis. Two groups were studied. Group I: 34 (49.3%) children had previous or current use of systemic corticotherapy (22 girls; 12 boys; mean age: 11.3 years; mean disease duration: 5.9 years; mean corticotherapy duration: 2.9 years; mean cumulative dose of previous corticosteroids: 5000 mg); Group II: 35 (50.7%) children had no previous use of corticosteroids (27 girls; 8 boys; mean age: 11.7 years; mean disease duration: 5.3 years). The groups were compared statistically. RESULTS: In the group that had received corticotherapy (Group I), osteochondral abnormalities were significantly correlated to long-standing disease (>3.5 years; p<0.001). This correlation was not found in the group that had no previous history of corticotherapy (Group II). No correlations were established between median dose of corticosteroids and magnetic resonance imaging findings. CONCLUSION: It is important to further investigate the long-term intra-articular effects of systemic corticotherapy to ensure that the side effects of the aggressive therapy will not be more harmful for the joints than the symptoms suffered over the natural course of the disease.
Resumo:
This present study aimed to investigate the fatigue life of unused (new) endodontic instruments made of NiTi with control memory by Coltene™ and subjected to the multi curvature of a mandibular first molar root canal. Additionally, the instrument‟s structural behaviour was analysed through non-linear finite element analysis (FEA). The fatigue life of twelve Hyflex™ CM files was assessed while were forced to adopt a stance with multiple radius of curvature, similar to the ones usually found in a mandibular first molar root canal; nine of them were subjected to Pecking motion, a relative movement of axial type. To achieve this, it was designed an experimental setup with the aim of timing the instruments until fracture while worked inside a stainless steel mandibular first molar model with relative axial motion to simulate the pecking motion. Additionally, the model‟s root canal multi-curvature was confirmed by radiography. The non-linear finite element analysis was conducted using the computer aided design software package SolidWorks™ Simulation, in order to define the imposed displacement required by the FEA, it was necessary to model an endodontic instrument with simplified geometry using SolidWorks™ and subsequently analyse the geometry of the root canal CAD model. The experimental results shown that the instruments subjected to pecking motion displayed higher fatigue life values and higher lengths of fractured tips than those with only rotational relative movement. The finite element non-linear analyses shown, for identical conditions, maximum values for the first principal stress lower than the yield strength of the material and those were located in similar positions to the instrument‟s fracture location determined by the experimental testing results.
Resumo:
PhD Thesis in Sciences Specialization in Chemistry
Resumo:
Polymer based scintillator composites have been produced by combining polystyrene (PS) and Gd2O3:Eu3+ scintillator nanoparticles. Polystyrene has been used since it is a flexible and stable binder matrix, resistant to thermal and light deterioration and with suitable optical properties. Gd2O3:Eu3+ has been selected as scintillator material due to its wide band gap, high density and visible light yield. The optical, thermal and electrical characteristics of the composites were studied as a function of filler content, together with their performance as scintillator material. Additionally 1wt.% of 2,5 dipheniloxazol (PPO) and 0.01wt.% of (1,4-bis(2-(5-phenioxazolil))-benzol (POPOP) were introduced in the polymer matrix in order to strongly improve light yield, i.e. the measured intensity of the output visible radiation, under X-ray irradiation. Whereas increasing scintillator filler concentration (from 0.25wt.% to 7.5wt.%) increases scintillator light yield, decreases the optical transparency of the composite. The addition of PPO and POPOP, strongly increased the overall 2 transduction performance of the composite due to specific absorption and re-emission processes. It is thus shown that Gd2O3:Eu3+/PPO/POPOP/PS composites in 0.25 wt.% of scintillator content with fluorescence molecules is suitable for the development of innovate large area X-ray radiation detectors with huge demand from the industries.
Resumo:
Bulimia nervosa (BN) is an eating disorder characterized by recurrent episodes of binge eating and inappropriate compensatory behaviors (such as purging, fasting, or excessive exercise) to prevent weight gain. BN has been associated with deficits in inhibitory control processes. The basal ganglia specifically, the nucleus accumbens (NAc) and the caudate nucleus (CN) are part of the frontostriatal circuits involved in inhibitory control. The main goal of this study was to investigate the presence of morphological alterations in the NAc and the CN in a sample of patients diagnosed with BN.
Resumo:
Purpose: To determine the relationship of goblet cell density (GCD) with tear function and ocular surface physiology. Methods: This was a cross-sectional study conducted in 35 asymptomatic subjects with mean age 23.8±3.6 years. Tear film assessment, conjunctiva and cornea examination were done in each subject. Conjunctival impression cytology was performed by applying Nitrocellulose Millipore MFTM-Membrane filter over the superior bulbar conjunctiva. The filter paper was than fixed with 96% ethanol and stained with Periodic Acid Schiff, Hematoxylin and Eosin. GCD was determined by optical microscopy. Relation between GCD and Schirmer score, tear break-up time (TBUT), bulbar redness, limbal redness and corneal staining was determined. Results: The mean GCD was 151±122 cells/mm2. GCD was found higher in eyes with higher Schirmer score but it was not significant (p = 0.75). There was a significant relationship ofGCDwith TBUT (p = 0.042). GCD was not correlated with bulbar redness (p = 0.126), and limbal redness (p = 0.054) as well as corneal staining (p = 0.079). No relationship of GCD with age and gender of the subjects (p > 0.05) was observed. Conclusion: GCD was found correlated with TBUT but no significant correlation was found with the aqueous portion of the tear, limbal as well as bulbar redness and corneal staining.
Resumo:
Tese de Doutoramento (Programa Doutoral em Engenharia Biomédica)
Resumo:
Objective To systematically review the scientific literature on the psychometric properties of international instruments for the assessment of autism spectrum disorder (ASD) in the Brazilian population. Methods A search of bibliographic references was conducted in six electronic databases: PsycINFO, PubMed, IndexPsi, Lilacs, Capes (theses and dissertations) and SciELO. The studies were selected by two independent researchers. Results The procedure identified 11 studies of the Brazilian population that encompassed six ASD assessment tools. Given the information provided, the adaptation of the M-CHAT, a screening instrument, was the best conducted. All steps of the adaptation process were described and the changes made to the final version of the instrument were presented, which was not addressed in other studies. In terms of reliability, all of the instruments that assessed internal consistency showed adequate values. In addition, the ADI-R and the CARS adaptations also satisfactorily contemplated inter-rater reliability and test-retest indices, respectively. Finally, all studies aiming to validate instruments showed evidence of validity and sensitivity, and specificity values above 0.90 were observed in the ASQ, ADI-R and ABC. Conclusion Considering both the psychometric aspects and the copyright information, the screening instrument that currently appears to be best indicated for clinical and research use is the M-CHAT. It was also noticed that there are still no specific ASD diagnostic tools available for use in Brazil. This lack of diagnostic instruments consists in a critical situation for the improvement of clinical practice and the development of research in this area.
Resumo:
Objective This study describes the development of two updating measures of working memory (WM): Letter Updating Test (LUT) and Word Updating Test (WUT). Methods In stage 1, items were created and the instruments were assessed by experts and laymen. In stage 2, tests were given to 15 patients with schizophrenia and 15 paired controls. All were able to understand and respond to the instruments. In stage 3, 141 patients with schizophrenia and 119 healthy controls aged 18 to 60 took part; they were assessed on WM, processing speed (PS) and functional outcome. Results The results showed adequate rates of internal consistency for both measures developed, for both the total sample and each group separately, as well as evidence of convergent validity, discriminant validity and sensitivity to differentiate performance among the groups. Principal component analysis yielded two components, one for updating tests and other for PS measures, indicating factorial validity. Positive and significant, yet low, correlations were found with functionality measures. Conclusion These results provide adequate psychometric parameters for the measures developed, applicable to cognitive research settings in schizophrenia.
Resumo:
The preclinical development of nanomedicines raises several challenges and requires a comprehensive characterization. Among them is the evaluation of the biodistribution following systemic administration. In previous work, the biocompatibility and in vitro targeting ability of a glycol chitosan (GC) based nanogel have been validated. In the present study, its biodistribution in the mice is assessed, using near-infrared (NIR) fluorescence imaging as a tool to track the nanogel over time, after intravenous administration. Rapid whole body biodistribution of both Cy5.5 labeled GC nanogel and free polymer is found at early times. It remains widespreadly distributed in the body at least up to 6 h postinjection and its concentration then decreases drastically after 24 h. Nanogel blood circulation half-life lies around 2 h with the free linear GC polymer presenting lower blood clearance rate. After 24 h, the blood NIR fluorescence intensity associated with both samples decreases to insignificant values. NIR imaging of the organs shows that the nanogel had a body clearance time of 48 h, because at this time point a weak signal of NIR fluorescence is observed only in the kidneys. Hereupon it can be concluded that the engineered GC nanogel has a fairly long blood circulation time, suitable for biomedical applications, namely, drug delivery, simultaneously allowing efficient and quick body clearance.
Resumo:
OBJECTIVE: To assess the cardiovascular features of Ullrich-Turner's syndrome using echocardiography and magnetic resonance imaging, and to correlate them with the phenotype and karyotype of the patients. The diagnostic concordance between the 2 methods was also assessed. METHODS: Fifteen patients with the syndrome were assessed by echocardiography and magnetic resonance imaging (cardiac chambers, valves, and aorta). Their ages ranged from 10 to 28 (mean of 16.7) years. The karyotype was analyzed in 11 or 25 metaphases of peripheral blood lymphocytes, or both. RESULTS: The most common phenotypic changes were short stature and spontaneous absence of puberal development (100%); 1 patient had a cardiac murmur. The karyotypes detected were as follows: 45,X (n=7), mosaics (n=5), and deletions (n=3). No echocardiographic changes were observed. In regard to magnetic resonance imaging, coarctation and dilation of the aorta were found in 1 patient, and isolated dilation of the aorta was found in 4 patients. CONCLUSION: The frequencies of coarctation and dilation of the aorta detected on magnetic resonance imaging were similar to those reported in the literature (5.5% to 20%, and 6.3% to 29%, respectively). This confirmed the adjuvant role of magnetic resonance imaging to Doppler echocardiography for diagnosing cardiovascular alterations in patients with Ullrich-Turner's syndrome.
Resumo:
OBJECTIVE: Doppler tissue imaging (DTI) enables the study of the velocity of contraction and relaxation of myocardial segments. We established standards for the peak velocity of the different myocardial segments of the left ventricle in systole and diastole, and correlated them with the electrocardiogram. METHODS: We studied 35 healthy individuals (27 were male) with ages ranging from 12 to 59 years (32.9 ± 10.6). Systolic and diastolic peak velocities were assessed by Doppler tissue imaging in 12 segments of the left ventricle, establishing their mean values and the temporal correlation with the cardiac cycle. RESULTS: The means (and standard deviation) of the peak velocities in the basal, medial, and apical regions (of the septal, anterior, lateral, and posterior left ventricle walls) were respectively, in cm/s, 7.35(1.64), 5.26(1.88), and 3.33(1.58) in systole and 10.56(2.34), 7.92(2.37), and 3.98(1.64) in diastole. The mean time in which systolic peak velocity was recorded was 131.59ms (±19.12ms), and diastolic was 459.18ms (±18.13ms) based on the peak of the R wave of the electrocardiogram. CONCLUSION: In healthy individuals, maximum left ventricle segment velocities decreased from the bases to the ventricular apex, with certain proportionality between contraction and relaxation (P<0.05). The use of Doppler tissue imaging may be very helpful in detecting early alterations in ventricular contraction and relaxation.