914 resultados para mouth lesion
Resumo:
The diagnosis, grading and classification of tumours has benefited considerably from the development of DCE-MRI which is now essential to the adequate clinical management of many tumour types due to its capability in detecting active angiogenesis. Several strategies have been proposed for DCE-MRI evaluation. Visual inspection of contrast agent concentration curves vs time is a very simple yet operator dependent procedure, therefore more objective approaches have been developed in order to facilitate comparison between studies. In so called model free approaches, descriptive or heuristic information extracted from time series raw data have been used for tissue classification. The main issue concerning these schemes is that they have not a direct interpretation in terms of physiological properties of the tissues. On the other hand, model based investigations typically involve compartmental tracer kinetic modelling and pixel-by-pixel estimation of kinetic parameters via non-linear regression applied on region of interests opportunely selected by the physician. This approach has the advantage to provide parameters directly related to the pathophysiological properties of the tissue such as vessel permeability, local regional blood flow, extraction fraction, concentration gradient between plasma and extravascular-extracellular space. Anyway, nonlinear modelling is computational demanding and the accuracy of the estimates can be affected by the signal-to-noise ratio and by the initial solutions. The principal aim of this thesis is investigate the use of semi-quantitative and quantitative parameters for segmentation and classification of breast lesion. The objectives can be subdivided as follow: describe the principal techniques to evaluate time intensity curve in DCE-MRI with focus on kinetic model proposed in literature; to evaluate the influence in parametrization choice for a classic bi-compartmental kinetic models; to evaluate the performance of a method for simultaneous tracer kinetic modelling and pixel classification; to evaluate performance of machine learning techniques training for segmentation and classification of breast lesion.
Resumo:
To evaluate retrospectively in patients with Crohn's disease (CD) if magnetic resonance (MR) motility alterations correlate with CD typical lesions leading to an increased detection rate.
Resumo:
OBJECTIVES: Scaling and root planing are the causal procedure in the treatment of periodontitis. Many attempts have been made to improve the outcome. The aim of this study was to verify the influence of the extended use of chlorhexidine after one-stage full-mouth (FM) SRP in patients with chronic periodontitis on the clinical outcome after 3 months. METHODS: Eighty-one patients with pockets > or =5 mm were treated by FM. All patients rinsed additionally with 0.2% chlorhexidine (CHX) twice daily over 3 months. Plaque index, bleeding on probing, probing depth (PD) and clinical attachment level (CAL) were recorded at baseline and after 1 and 3 months. RESULTS: In the test group, all variables were significantly improved after 1 and 3 months. Mean reduction of PD and CAL gain was 2.25 +/- 1.08 and 1.67 +/- 1.08 after 1 and 2.99 +/- 1.11 and 2.33 +/- 1.31 after 3 months respectively. CONCLUSIONS: Over 3 months of extended use of CHX mouth rinse after SRP showed slightly but statistically significant better results.
Resumo:
To evaluate the capability of spectral computed tomography (CT) to improve the characterization of cystic high-attenuation lesions in a renal phantom and to test the hypothesis that spectral CT will improve the differentiation of cystic renal lesions with high protein content and those that have undergone hemorrhage or malignant contrast-enhancing transformation.
Resumo:
This study investigated the differences in clinical outcomes between patients with bifurcation lesions (BL) treated with a biolimus-eluting stent (BES) with a biodegradable polymer, and a sirolimus-eluting stent (SES) with a durable polymer.
Evaluation of perpendicular reflection intensity for assessment of caries lesion activity/inactivity
Resumo:
The aim of this study was to evaluate, using visual assessment, an experimental optical sensor measuring perpendicular reflection intensity (PRI) as an indicator of enamel caries lesion activity/inactivity. Forty teeth with either an active or an inactive enamel lesion were selected from a pool of extracted teeth. Each tooth was cut into halves, with a clinically sound half and a half with a non-cavitated enamel lesion. After gentle plaque removal, the teeth were kept moistened. The lesions were then photographed and a defined measuring site per lesion was chosen and indicated with an arrow on a printout. Independently, the chosen site was visually assessed for lesion activity, and its glossiness was measured with PRI assessment. Surface roughness (SR) was assessed with optical profilometry using a confocal microscope. Visual assessment and PRI were repeated after several weeks and a reliability analysis was performed. For enamel lesions visually scored as active versus inactive, significantly different values were obtained with both PRI and SR. PRI values of the clinically sound control surfaces were significantly different only from active lesions. Generally, inactive lesions had the same glossiness and the same roughness as the sound control surfaces. The reliabilities for visual assessment (? = 0.89) and for PRI (ICC = 0.86) were high. It is concluded that, within the limits of this study, PRI can be regarded as a promising tool for quantitative enamel lesion activity assessment. There is scope and potential for the PRI device to be considerably improved for in vivo use.
Resumo:
To investigate the impact on microbiologic variables of full-mouth scaling (FMS) and conventional scaling and root planing (cSRP) after 12 months.
Resumo:
Blue-light fundus autofluorescence (FAF) imaging is currently widely used for assessing dry age-related macular degeneration (ARMD). However, at this wavelength, the fovea appears as circular zone of marked hypofluorescence, due to the absorption of macular pigment (MP). This dark spot could be misinterpreted as an atrophic area and could lead to difficulties in identifying small, central changes. The purpose of the study was to analyze differences in image quality, FAF patterns, and lesion size, when using conventional blue-light (Λ(1) = 488 nm) and green-light (Λ(2) = 514 nm) FAF.
Resumo:
The aim of this study was to determine gender differences in atherosclerotic lesion morphology and distribution pattern of patients with critical limb ischemia (CLI).
Resumo:
We present an automatic method to segment brain tissues from volumetric MRI brain tumor images. The method is based on non-rigid registration of an average atlas in combination with a biomechanically justified tumor growth model to simulate soft-tissue deformations caused by the tumor mass-effect. The tumor growth model, which is formulated as a mesh-free Markov Random Field energy minimization problem, ensures correspondence between the atlas and the patient image, prior to the registration step. The method is non-parametric, simple and fast compared to other approaches while maintaining similar accuracy. It has been evaluated qualitatively and quantitatively with promising results on eight datasets comprising simulated images and real patient data.
Resumo:
Vessel angulation and large changes in vessel geometry after stent implantation have been associated with an increased risk of target lesion failure (TLF) using bare-metal stents. Second-generation drug-eluting stents (DES)offer superior conformability and inhibition of neointima. The aim of the study is to investigate the relationship between pre and post-implant vessel geometry and the occurrence of TLF at 1 year after treatment with second-generation DES; and to compare the conformability of Resolute and Xience stents.