978 resultados para maintenance cost
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia da Manutenção
Resumo:
Dynamic and distributed environments are hard to model since they suffer from unexpected changes, incomplete knowledge, and conflicting perspectives and, thus, call for appropriate knowledge representation and reasoning (KRR) systems. Such KRR systems must handle sets of dynamic beliefs, be sensitive to communicated and perceived changes in the environment and, consequently, may have to drop current beliefs in face of new findings or disregard any new data that conflicts with stronger convictions held by the system. Not only do they need to represent and reason with beliefs, but also they must perform belief revision to maintain the overall consistency of the knowledge base. One way of developing such systems is to use reason maintenance systems (RMS). In this paper we provide an overview of the most representative types of RMS, which are also known as truth maintenance systems (TMS), which are computational instances of the foundations-based theory of belief revision. An RMS module works together with a problem solver. The latter feeds the RMS with assumptions (core beliefs) and conclusions (derived beliefs), which are accompanied by their respective foundations. The role of the RMS module is to store the beliefs, associate with each belief (core or derived belief) the corresponding set of supporting foundations and maintain the consistency of the overall reasoning by keeping, for each represented belief, the current supporting justifications. Two major approaches are used to reason maintenance: single-and multiple-context reasoning systems. Although in the single-context systems, each belief is associated to the beliefs that directly generated it—the justification-based TMS (JTMS) or the logic-based TMS (LTMS), in the multiple context counterparts, each belief is associated with the minimal set of assumptions from which it can be inferred—the assumption-based TMS (ATMS) or the multiple belief reasoner (MBR).
Resumo:
A low cost method (LCM) to produce a gaseous environment for the isolation of Helicobacter pylori, was compared with the standard Gas Park system. The LCM uses a carbonated antacid tablet, a plastic bag with tap water, a candle, and a wide-mouthed glass jar provided with a tight-fitting metalic screw cap and a rubber gasket. Antral gastric biopsies from 153 cases were incubated by duplicate on blood agar plates and treated with the two methods. In 95 cases the agent was isolated from both, and only from the standard method in 10 cases; the opposite condition was found in five cases, and 43 were negative. That difference is not significant (Pearson's X²= 93.25 p > 0,05)
Resumo:
Safety is one of the major concerns of process safety engineers in most industrial facilities all over the world. To this scope, some events play an important role once the effect of their consequences can be assumed as totally undesirable. One of these events refers to the occurrence of a fire. Such event can result in catastrophic consequences for life, equipment, and continuity of activities or even leading to environmental damage. A fire protection equipment with low reliability means that this equipment are often unavailable and thus the risk of a fire increases. Maintenance of fire protection equipment is very important because this kind of systems is mostly in a dormant mode, which gives uncertainty about their operability when demanded in a real situation of fire. This article outlines the importance of tests, inspection, and maintenance operations in the context of a fire sprinkler system and proposes a methodology based on international standards and supported by test/inspection reports to correct the frequency of these actions according to the level of degradation of the components and regarding safety purposes. © 2015 American Institute of Chemical Engineers.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Conservação e Restauro
Resumo:
A presente dissertação centrou-se no estudo técnico-económico de dois cenários futuros para a continuação de fornecimento de energia térmica a um complexo de piscinas existente na região do vale do Tâmega. Neste momento a central de cogeração existente excedeu a sua licença de utilização e necessita de ser substituída. Os dois cenários em estudo são a compra de uma nova caldeira, a gás natural, para suprir as necessidades térmicas da caldeira existente a fuelóleo, ou o uso de um sistema de cogeração compacto que poderá estar disponível numa empresa do grupo. No primeiro cenário o investimento envolvido é cerca de 456 640 € sem proveitos de outra ordem para além dos requisitos térmicos, mas no segundo cenário os resultados são bem diferentes, mesmo que tenha de ser realizado o investimento de 1 000 000 € na instalação. Para este cenário foi efetuado um levantamento da legislação nacional no que toca à cogeração, recolheram-se dados do edifício como: horas de funcionamento, número de utentes, consumos de energia elétrica, térmica, água, temperatura da água das piscinas, temperatura do ar da nave, assim como as principais características da instalação de cogeração compacta. Com esta informação realizou-se o balanço de massa e energia e criou-se um modelo da nova instalação em software de modelação processual (Aspen Plus® da AspenTech). Os rendimentos térmico e elétrico obtidos da nova central de cogeração compacta foram, respetivamente, de 38,1% e 39,8%, com uma percentagem de perdas de 12,5% o que determinou um rendimento global de 78%. A avaliação da poupança de energia primária para esta instalação de cogeração compacta foi de 19,6 % o que permitiu concluir que é de elevada eficiência. O modelo criado permitiu compreender as necessidades energéticas, determinar alguns custos associados ao processo e simular o funcionamento da unidade com diferentes temperaturas de ar ambiente (cenários de verão e inverno com temperaturas médias de 20ºC e 5ºC). Os resultados revelaram uma diminuição de 1,14 €/h no custo da electricidade e um aumento do consumo de gás natural de 62,47 €/h durante o período mais frio no inverno devido ao aumento das perdas provocadas pela diminuição da temperatura exterior. Com esta nova unidade de cogeração compacta a poupança total anual pode ser, em média, de 267 780 € admitindo um valor para a manutenção de 97 698 €/ano. Se assim for, o projeto apresenta um retorno do investimento ao fim de 5 anos, com um VAL de 1 030 430 € e uma taxa interna de rentabilidade (TIR) de 14% (positiva, se se considerar a taxa de atualização do investimento de 3% para 15 anos de vida). Apesar do custo inicial ser elevado, os parâmetros económicos mostram que o projeto tem viabilidade económica e dará lucro durante cerca de 9 anos.
Resumo:
Dissertação apresentada ao Instituto Superior de Administração e Contabilidade do Porto para obtenção do Grau de Mestre em Logística Orientada por: Professora Doutora Maria Clara Rodrigues Bento Vaz Fernandes
Resumo:
A metrologia na saúde tem um elevado grau de importância no quotidiano hospitalar dado que muitas decisões são tomadas com base em medições. Além disso, a constante evolução tecnológica na área da saúde e o número crescente de parâmetros fisiológicos dos equipamentos médicos exige a constante preocupação com o controlo metrológico. Assim, o funcionamento eficiente destes poderá contribuir para a segurança, uma melhor e mais rápida recuperação do doente e, consequentemente, um aumento do tempo de vida do equipamento, o que por sua vez se reflete numa maior economia de custos. A otimização de protocolos de metrologia em saúde, a elaboração de planos de controlo para validação de equipamentos médicos-hospitalares, a sensibilização de profissionais de saúde para o controlo metrológico, assim como o conhecimento das aplicações informáticas da organização são essenciais para uma eficaz gestão da manutenção hospitalar. O Serviço de Instalações e Equipamentos do Centro Hospitalar do Tâmega e Sousa, trabalha no sentido de assegurar uma resposta rápida, otimizada e eficiente para satisfazer as necessidades hospitalares através da aplicação de metodologias e ferramentas da qualidade destinadas à metrologia em saúde. Assim, o objetivo principal deste trabalho é apresentar metodologias e ferramentas aplicadas no controlo de parâmetros de equipamentos médico-hospitalares tais como, dispositivos de infusão, monitores de sinais vitais, eletrocardiógrafos, cardiotocógrafos, desfibrilhadores, incubadoras, aparelhos de fototerapia, bem como, o processo de gestão da manutenção aplicado pelo Serviço de Instalações e Equipamentos. Neste sentido foi possível demonstrar que o controlo metrológico é de extrema importância para uma instituição hospitalar.
Resumo:
The high penetration of distributed energy resources (DER) in distribution networks and the competitiveenvironment of electricity markets impose the use of new approaches in several domains. The networkcost allocation, traditionally used in transmission networks, should be adapted and used in the distribu-tion networks considering the specifications of the connected resources. The main goal is to develop afairer methodology trying to distribute the distribution network use costs to all players which are usingthe network in each period. In this paper, a model considering different type of costs (fixed, losses, andcongestion costs) is proposed comprising the use of a large set of DER, namely distributed generation(DG), demand response (DR) of direct load control type, energy storage systems (ESS), and electric vehi-cles with capability of discharging energy to the network, which is known as vehicle-to-grid (V2G). Theproposed model includes three distinct phases of operation. The first phase of the model consists in aneconomic dispatch based on an AC optimal power flow (AC-OPF); in the second phase Kirschen’s andBialek’s tracing algorithms are used and compared to evaluate the impact of each resource in the net-work. Finally, the MW-mile method is used in the third phase of the proposed model. A distributionnetwork of 33 buses with large penetration of DER is used to illustrate the application of the proposedmodel.
Resumo:
Dissertation presented at Faculty of Sciences and Technology of the New University of Lisbon to attain the Master degree in Electrical and Computer Science Engineering
Resumo:
Anopheles albimanus is one of the main vectors of malaria in Central America and the Caribbean, based on its importance, there are previous reports of the successful colonization of this species in Latin America countries. Mosquitoes were collected in the Aragua State of Venezuela colonized in the laboratory, using a simple and efficient maintenance method. Based on life table calculations under well established laboratory conditions, the Survival Rate Probability was constant and always close to 1 in immature stages, the Reproductive Net Rate (Ro) was 3.83, the generation time (Tc) was 24.5 days and the Intrinsic Growth Rate (rm) was 0.0558. This is the first report of the colonization of A. albimanus in Venezuela.
Resumo:
O Sector eléctrico possui uma grande importância nas sociedades modernas. Dados os elevados custos de produção de energia e o grande impacto que esta tem na nossa economia e na sociedade, em geral, a utilização mais eficiente da energia é um factor fulcral. Com a evolução da electrónica e consequente aumento das capacidades dos computadores, as protecções eléctricas são cada vez mais eficazes e com índices de fiabilidade mais elevados, algo muito importante em instalações de elevado custo de investimento e manutenção. No entanto, o seu bom funcionamento está dependente do correcto dimensionamento das protecções e de uma análise técnica capaz de prever necessidades futuras. Após uma breve introdução no capítulo 1 é efectuado no capítulo 2 um breve estudo de protecções eléctricas e o seu estado de arte. Nos Capítulos 3 e 4 é efectuado o dimensionamento e estudo da selectividade das protecções de grupo de Alternador e Transformador escolhidos para a nova central de cogeração da refinaria de Matosinhos da Galp. No presente estudo foram apenas consideradas as protecções típicas de alternador e apenas a protecção diferencial do transformador. Todas as protecções foram dimensionadas com base no tutorial de protecções de geradores do IEE e com informação referente ao manual de instruções do relé G60 da GE industrial systems, o DTP-B da GE multilin e o ELIN Power Plant Automation. No Capítulo 5 é demonstrada a importância da análise Safety Instruments Systems (SIS), o seu modo de aplicação e necessidade de implementação em locais industriais como o caso em estudo. Por último, é efectuado um pequeno estudo económico onde é efectuada a comparação dos custos dos diversos equipamentos, protecções e manutenções efectuadas.
Resumo:
As aplicações de Gestão ou Faturação são uma presença indispensável hoje em dia. Tendo o seu início nas aplicações “MS-DOS” em modo de texto, estas aplicações acompanharam a evolução dos sistemas operativos adotando um ambiente gráfico de forma natural. Se há poucos anos apenas as empresas com volumes de negócio significativo possuíam software de faturação, este foi sendo adotado por cada vez mais empresas e pequenos negócios. As alterações legislativas introduzidas desde 2011 conduziram a uma adoção generalizada por parte de pequenas e microempresas. O mercado de aplicações de gestão está saturado pelos grandes produtores de software nacionais: Primavera, Sage, etc. Estas aplicações, tendo sido construídas para PMEs (Pequenas e Médias Empresas) e mesmo grandes empresas, são excessivamente complexas e onerosas para muito pequenas e microempresas. O Modelo de negócio destes produtores de software é primordialmente a venda de Licenças e contratos de Manutenção, nalguns casos através de redes de Agentes. Este projeto teve como objetivo o desenvolvimento de uma Aplicação de Faturação, de baixo custo, simples e cross-platform para ser comercializada em regime de aluguer em Pequenas e Micro Empresas.
Resumo:
Este trabalho pretende avaliar e melhorar o modo de execução da aplicação da técnica de perfuração, não comprometendo a jusante, no ciclo de operações, a qualidade do desmonte, visando assim, uma optimização técnico-económica. Este manuscrito irá centrar-se na optimização da etapa da perfuração, visando assim a optimização do ciclo total da perfuração. As tarefas realizadas numa pedreira constituem um ciclo de operações. Uma das operações envolvidas no desmonte de maciços rochosos é a perfuração. A forma como esta é executada é determinante para o sucesso do desmonte. O correcto dimensionamento dos acessórios de perfuração, afiação de bits, manutenção preventiva dos equipamentos de perfuração e a constante formação dos operadores fazem parte de um conjunto de acções que irão determinar o sucesso da operação de perfuração, tendo sempre em vista, uma optimização técnico-económica, ou seja, produzir mais a um custo mais baixo. O estudo dos parâmetros do maciço rochoso aliado a uma perfuração cuidadosa e alinhada é evidenciado com o intuito de uma abordagem de geoengenharia integrada dos maciços rochosos. O estudo foi realizado na pedreira da APS, S.A. (Pedreira de Monte Chãos), tendo como análise os dados desde o início do projecto até à data. Para fundamentar este estudo, aborda-se os parâmetros geológico-geotécnicos e geomecânicos do maciço remanescente, verificando assim as ferramentas de corte mais adequadas ao caso e averiguar a influência da afiação de bits, quer seja manual ou semiautomática, e de que forma a mesma irá influenciar nos rendimentos e vidas úteis obtidas, tendo como objectivo, melhorar o custo por metro de furação realizado.
Resumo:
Este trabalho académico surge no âmbito da realização da dissertação do Mestrado em Engenharia e Gestão Industrial. Tem como objetivo a melhoria da gestão do Departamento de Infraestruturas, numa empresa de produção de motores elétricos para a indústria automóvel, através da análise, implementação e melhoria de um software de gestão de manutenção, de forma a aumentar a eficiência do Departamento. Este estudo foi desenvolvido durante um estágio curricular na empresa Globe Motors Portugal Lda, localizada em Vila do Conde. Para sua sustentação, foi efetuada uma análise funcional, suportada por um Software de gestão de manutenção, de forma a perceber qual a importância que o mesmo tem no funcionamento do Departamento de Infraestruturas. Pretendeu-se compreender quais as vantagens e desvantagens da sua utilização. Posteriormente, implementou-se uma nova versão deste software, analisando-se os pontos fortes e as oportunidades de melhoria, de forma a tornar o Departamento de infraestruturas mais eficiente, através da utilização desta renovada ferramenta de trabalho. Como objetivo último, pretendeu-se à melhoria da organização e gestão do Departamento de infraestruturas, contribuindo para um desenvolvimento de toda a empresa, uma vez que comungamos a ideia de que só é possível ser competitivo, num mercado altamente exigente, através de processos eficientes, possibilitando a redução de custos a todos os níveis.