357 resultados para electroless plating


Relevância:

10.00% 10.00%

Publicador:

Resumo:

"Credit is largely due to Frank D. Graham ... for the authorship of the Guides, and for the original sketches illustrating electrical principles and construction."--Pref. to no. 1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The stepped rotating cylinder electrode (SRCE) geometry has been developed as a simple aid to the practical study of the flow-enhanced corrosion and applied electrochemistry problems commonly observed under conditions of disturbed, turbulent flow. The electrodeposition of cupric ions from an acid sulphate plating bath has been used to characterise differential rates of mass transfer to the SRCE. The variation in thickness of electrodeposited copperfilms has allowed the mapping of local rates of mass transfer over the active surface of this geometry. Both optical and scanning electron microscopy were used for the examination of metallographic sections to provide a high resolution evaluation of the distribution of mass transfer coefficient. Results are also discussed using the convective-diffusion model in combination with the existing direct numerical flow simulation (DNS) data for this geometry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oropharyngeal candidiasis is a common clinical problem encountered in patients with defects in innate or cell-mediated immunity. We have previously shown that recovery from chronic oropharyngeal candidiasis is dependent on CD4+ T-cell augmentation of neutrophil and macrophage candidacidal activity, and that the immune response is characterised by the production of cytokines such as IL-12 and IFN-gamma by cells in the local draining lymph nodes, and by the expression of TNF-alpha in the oral tissues. Objective: The purpose of this study was to elaborate on the role of these cytokines in recovery from oropharyngeal candidiasis, by using cytokine-specific gene-knockout mice. Methods: These mice are created by targeted gene mutation (tm1) of embryonic stem (ES) cells microinjected into host embryos. IL-4, IL-10, IL-12, IFN-gamma and TNF-alpha knockout mice, and appropriate controls, were infected orally with 108 viable C. albicans yeasts. The infection was quantified by swabbing the oral cavity and plating on Sabouraud's agar. Results: Tnftm1mice developed an acute severe infection characterized by an increased fungal load in the early stages of infection, but cleared the yeast within the same time frame as control mice (21 days). On the other hand, Il12btm1 mice developed a chronic oropharyngeal infection (120 days) similar to that seen in T-cell deficient (Foxn1nu/Foxn1nu) mutant mice. There was no significant difference between Il4tm1, Il10tm1, and Ifngtm1 mice and their respective controls. Conclusions: Tnftm1 mice may be rendered more susceptible through impaired recruitment of phagocytic cells, and/or impaired killing of C. albicans, whereas Il12btm1 mice may not be capable of activating naïve T-cells or inducing an appropriate cellular immune response. Supported by NHMRC and ADRF.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The object of this work was to further develop the idea introduced by Muaddi et al (1981) which enables some of the disadvantages of earlier destructive adhesion test methods to be overcome. The test is non-destructive in nature but it does need to be calibrated against a destructive method. Adhesion is determined by measuring the effect of plating on internal friction. This is achieved by determining the damping of vibrations of a resonating specimen before and after plating. The level of adhesion was considered by the above authors to influence the degree of damping. In the major portion of the research work the electrodeposited metal was Watt's nickel, which is ductile in nature and is therefore suitable for peel adhesion testing. The base metals chosen were aluminium alloys S1C and HE9 as it is relatively easy to produce varying levels of adhesion between the substrate and electrodeposited coating by choosing the appropriate process sequence. S1C alloy is the commercially pure aluminium and was used to produce good adhesion. HE9 aluminium alloy is a more difficult to plate alloy and was chosen to produce poorer adhesion. The "Modal Testing" method used for studying vibrations was investigated as a possible means of evaluating adhesion but was not successful and so research was concentrated on the "Q" meter. The method based on the use of a "Q" meter involves the principle of exciting vibrations in a sample, interrupting the driving signal and counting the number of oscillations of the freely decaying vibrations between two known preselected amplitudes of oscillations. It was not possible to reconstruct a working instrument using Muaddi's thesis (1982) as it had either a serious error or the information was incomplete. Hence a modified "Q" meter had to be designed and constructed but it was then difficult to resonate non-magnetic materials, such as aluminium, therefore, a comparison before and after plating could not be made. A new "Q" meter was then developed based on an Impulse Technique. A regulated miniature hammer was used to excite the test piece at the fundamental mode instead of an electronic hammer and test pieces were supported at the two predetermined nodal points using nylon threads. This instrument developed was not very successful at detecting changes due to good and poor pretreatments given before plating, however, it was more sensitive to changes at the surface such as room temperature oxidation. Statistical analysis of test results from untreated aluminium alloys show that the instrument is not always consistent, the variation was even bigger when readings were taken on different days. Although aluminium is said to form protective oxides at room temperature there was evidence that the aluminium surface changes continuously due to film formation, growth and breakdown. Nickel plated and zinc alloy immersion coated samples also showed variation in Q with time. In order to prove that the variations in Q were mainly due to surface oxidation, aluminium samples were lacquered and anodised Such treatments enveloped the active surfaces reacting with the environment and the Q variation with time was almost eliminated especially after hard anodising. This instrument detected major differences between different untreated aluminium substrates.Also Q values decreased progressively as coating thicknesses were increased. This instrument was also able to detect changes in Q due to heat-treatment of aluminium alloys.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: There is limited research concerning how small companies in particular, respond to health and safety messages. AIMS: To understand individuals' knowledge and beliefs about chemical risks and to compare these with those of experts. METHODS: The use of chromic acid in particular, and also other chemicals associated with chrome plating were studied. All chromium plating firms were based in the West Midlands. The methodology involved initial face to face interviews (n = 21) with chromium platers, structured questionnaires (n = 84) to test the prevalence of beliefs identified in the interviews, an expert questionnaire, and a workshop to discuss findings. The responses of platers were compared with those of occupational health and safety experts. RESULTS: Although chromium platers appeared to understand the short term adverse effects of the chemicals to which they are exposed, their understanding of long term, or chronic effects appeared to be incomplete. They had good knowledge of acute effects based primarily on experience. Platers were aware of the hazardous nature of the chemicals with which they work, but did not draw distinction between the terms "hazards" and "risks". They had difficulties articulating the effects of the chemicals and how exposure might occur; although it is inappropriate to equate this with lack of knowledge. A significant minority of platers displayed deficiencies in understanding key technical terms used in Safety Data Sheets. CONCLUSIONS: This study provides a method which can be used to gain some understanding of workers' knowledge and beliefs about risks that they are exposed to in the workplace. The study also identifies gaps between the platers' knowledge and beliefs and those of experts. New risk information needs to be designed which addresses the information needs of platers using language that they understand.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In industry the colour of a gold alloy electrodeposit is checked by visual comparison with standard panels. The aims of the present work have been to access the application of spectrophotmetric techniques to the measurement of the colour of gold alloy electrodeposits and to examine the factors that influence the colour of thin deposits. The minimum thickness of deposit required to produce its final colour and completely hide the underlying substrate was measured and found to depend on the nature of the substrate, the plating solution and the operating conditions. Bright and matt electrodeposits were studied. The influence of alloying gold by adding copper, silver and indium to the plating solution were investigated. CIE chromaticity coordinates were calculated from spectrophotometric data using a computer programme written for the purpose. The addition of silver to a simple gold bath caused the colour of the deposit to change from yellow through green to near white in a smooth progression as the amount of silver in solid solution steadily increased. The colour of deposits formed when additions of copper were made was complicated by the formation of intermediate phases. À colour in the blue region of the spectrum was obtained in a few experiments investigating the influence of indium additions to the gold bath.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the increase use of de-icing salts on roads for safety, the need for improved corrosion resistance of the traditional galvanized automobile bodies has never been greater. In the present work, Zn alloy coatings (Zn-Ni and Zn-Co) were studied as an alternative to pure Zn coatings. The production of these deposits involved formulation of various acidic (pH of about 5.5) chloride based solutions. These showed anomalous deposition, that is, alloys were deposited much more easily than expected from the noble behaviour of Ni and Co metals. Coating compositions ranging from 0 to about 37% Ni and 20% Co were obtained. The chemical composition of the coatings depended very much on the electrolytes nature and operating conditions. The Ni content of deposits increased with increase in Ni bath concentration, temperature, pH and solution agitation but decreased considerably with increase in current density. The throwing power of the Zn-Ni solution deteriorated as Ni metal bath concentration increased. The Co content of deposits also increased with increase in Co bath concentration and temperature, and decreased with increase in current density. However, the addition of commercial organic additives to Zn-Co plating solutions suppressed considerably the amount of Co in the coatings. The Co content of deposits plated from Zincrolyte solution was found to be more sensitive to variation in current density than in the case of deposits plated from the alkaline Canning solution. The chromating procedures were carried out using laboratory formulated solution and commercially available ones. The deposit surface state was of great significance in influencing the formulation of conversion coatings. Bright and smooth deposits acquired an iridescent colour when treated with the laboratory formulated solution. However, the dull deposits acquired a brownish appearance. The correlation between the electrochemical test results and the neutral salt spray in marine environment was good. Non-chromated Zn-Ni coatings containing about 11-14% Ni increased in corrosion resistance compared to pure Zn. Non-chromated Zn-Co deposits of composition 4-8% were required to show a significant improvement in corrosion resistance Corrosion resistance was improved considerably by conversion coating. However, the type of conversion coating was very important. Samples treated in a laboratory solution performed badly compared to those treated in commercial solutions. Zn alloy coatings were superior to pure Zn, the Schloetter sample (13.8% Ni) had the lowest corrosion rate, followed by the Canning sample (1.0% Co) and then Zincrolyte (0.3% Co).Neither the chromium content of the conversion films nor the chromium state was found to have an effect on corrosion performance of the coatings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The deposition and properties of electroless nickel composite coatings containing graphite, PTFE and chromium were investigated. Solutions were developed for the codeposition of graphite and chromium with electroless nickel. Solutions for the deposition of graphite contained heavy metal ions for stability, with non-ionic and anionic surfactants to provide wetting and dispersion of the particles. Stability for the codeposition of chromium particles was achieved by oxidation of the chromium. Thin oxide layers of 200 nm thick prevented initiation of the electroless reaction onto the chromium. A mechanism for the formation of electroless composite coatings was considered based on the physical adsorption of particles and as a function of the adsorption of charged surfactants and metal cations from solution. The influence of variables such as particle concentration in solution, particle size, temperature, pH, and agitation on the volume percentage of particles codeposited was studied. The volume percentage of graphite codeposited was found to increase with concentration in solution and playing rate. An increase in particle size and agitation reduced the volume percentage codeposited. The hardness of nickel-graphite deposits was found to decrease with graphite content in the as-deposited and heat treated condition. The frictional and wear properties of electroless nickel-graphite were studied and compared to those of electroless nickel-PTFE. The self-lubricating nature of both coatings was found to be dependent on the ratio of coated area to uncoated area, the size and content of lubricating material in the deposit, and the load between contacting surfaces. The mechanism of self-lubrication was considered, concluding that graphite only produced an initial lubricating surface due to the orientation of flakes, unlike PTFE, which produced true self-lubrication throughout the coating life. Heat treatment of electroless nickel chromium deposits at 850oC for 8 and 16 hours produced nickel-iron-chromium alloy deposits with a phosphorus rich surface of high hardness. Coefficients of friction and wear rates were intially moderate for the phosphorus rich layer but increased for the nickel-iron-chromium region of the coating.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research was concerned with the effects of pulsed current on the electrodeposition of chromium and copper. In the case of the latter metal, a novel application has been studied and a theory proposed for the ability to improve throwing power by the joint use of organic additives and pulsed reverse current. During the course of the research, several improvements were made to the pulse plating unit.Chromium. A study was made of the effect of square wave pulsed current on various physical properties of deposits from three hard chromium plating electrolytes. The effect of varying frequency at a duty cycle of 50% on the mean bulk internal stress, visual appearance, hardness, crack characteristics and surface topography of the electrodeposits was determined. X-ray diffraction techniques were used to study the phases present in the deposits. The effect of varying frequency on the cathodic efficiencies of the electrolytes was also determined. It was found that pulsed current reduced the internal stress of deposits from the sulphate catalysed electrolyte. It also reduced or eliminated cracking of deposits and reduced deposit brightness. Under certain conditions, pulsed current was found to induce the co-deposition of hydrides of chromium. Deposit hardness was found to be reduced by the use of pulsed current. Cathodic efficiencies of the high efficiency electrolytes were reduced by use of pulsed current although this effect was minimised at high frequencies. The sulphate catalysed electrolyte showed an increase in efficiency over the frequency range where hydrides were co-deposited.Copper. The polarisation behaviour of acid copper solutions containing polyethers, sulphopropyl sulphides and chloride ions was studied using both direct and pulse reverse current. The effect of these additives on the rest potentials of copper deposits immersed in the electrolyte was also studied. Hole Throwing Power on printed circuit boards was determined using a specially designed test cell. The effect of pulsed reverse current on the hole throwing power of commercially produced printed circuit boards was also studied. Polyethers were found to have an inhibiting effect on the deposition of copper whereas the sulphopropyl sulphides produced a stimulating (i.e. depolarising) effect. Studies of rest potentials made when both additives were present indicated that the sulphopropyl sulphide was preferentially adsorbed. The use of pulsed reverse current in solutions containing both polyether and sulphopropyl sulphide was found to cause desorption of the sulphopropyl sulphide at the cathode surface. Thus, at higher current densities, the inhibiting effect of the polyether produced an increase in the cathodic polarisation potential. At lower current densities, the depolarisation effect of the sulphopropyl sulphide could still occur. On printed circuit boards, this effect was found to produce an increase in the `hole throwing power' due to depolarisation of the holes relative to the surface of the boards. Typically, using direct current, hole/surface thickness ratios of 40% were obtained when plating 0.6 mm holes in a 3.2 mm thick board at a current density of 3 A/dm2 whereas using pulsed reverse current, ratios of 80% could be obtained at an equivalent rate of deposition. This was observed both in laboratory tests and on commercially plated boards.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ion implantation modifies the surface composition and properties of materials by bombardment with high energy ions. The low temperature of the process ensures the avoidance of distortion and degradation of the surface or bulk mechanical properties of components. In the present work nitrogen ion implantation at 90 keV and doses above 1017 ions/cm2 has been carried out on AISI M2, D2 and 420 steels and engineering coatings such as hard chromium, electroless Ni-P and a brush plated Co-W alloy. Evaluation of wear and frictional properties of these materials was performed with a lubricated Falex wear test at high loads up to 900 N and a dry pin-on-disc apparatus at loads up to 40 N. It was found that nitrogen implantation reduced the wear of AISI 420 stainless steel by a factor of 2.5 under high load lubricated conditions and by a factor of 5.5 in low load dry testing. Lower but significant reductions in wear were achieved for AISI M2 and D2 steels. Wear resistance of coating materials was improved by up to 4 times in lubricated wear of hard Cr coatings implanted at the optimum dose but lower improvements were obtained for the Co-W alloy coating. However, hardened electroless Ni-P coatings showed no enhancement in wear properties. The benefits obtained in wear behaviour for the above materials were generally accompanied by a significant decrease in the running-in friction. Nitrogen implantation hardened the surface of steels and Cr and Co-W coatings. An ultra-microhardness technique showed that the true hardness of implanted layers was greater than the values obtained by conventional micro-hardness methods, which often result in penetration below the implanted depth. Scanning electron microscopy revealed that implantation reduced the ploughing effect during wear and a change in wear mechanism from an abrasive-adhesive type to a mild oxidative mode was evident. Retention of nitrogen after implantation was studied by Nuclear Reaction Analysis and Auger Electron Spectroscopy. It was shown that maximum nitrogen retention occurs in hard Cr coatings and AISI 420 stainless steel, which explains the improvements obtained in wear resistance and hardness. X-ray photoelectron spectroscopy on these materials revealed that nitrogen is almost entirely bound to Cr, forming chromium nitrides. It was concluded that nitrogen implantation at 90 keV and doses above 3x1017 ions/cm2 produced the most significant improvements in mechanical properties in materials containing nitride formers by precipitation strengthening, improving the load bearing capacity of the surface and changing the wear mechanism from adhesive-abrasive to oxidative.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ten grades of ABS and four grades of polypropylene have been plated with various copper + nickel + chromium coatings and subjected to a variety of tests. In corrosion studies the pre-electroplating sequence and plastics type have been shown to influence performance. One ABS pre-electroplating sequence was consistently associated with better corrosion performance; two factors were responsible for this, namely the more severe nature of the etch and the relatively more noble electroless nickel. Statistical analysis has indicated that order of severity of the corrosion tests was static-mobile-CASS, the latter being the least severe. In mechanical tests two properties of ABS and polypropJylene, ductility and impact strength, have been shown to be adversely affected when electrodeposited layers were applied. The cause of this is due to a complex of factors, the most important of which is the notch sensitivity of the plastics. Peel adhesion has been studied on flat panels and also on ones which had a ridge and a valley moulded into one face. High adhesion peaks occurred on the flat face at regions associated with the ridge and valley. The local moulding conditions induced by the features were responsible for this phenonemon. In the main programme the thermal cycling test was shown to be more likely than the peel adhesion test to give an indication of the service performance of electroplated plastics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of ultrasonic agitation on deposition from two iron group alloy plating solutions, nickel-cobalt and bright nickel-iron, have been studied. Comparison has been made with deposits plated from the same solutions using controlled air agitation. The ultrasonic equipment employed had a fixed frequency of 13 KHz but the power output from each transducer was variable up to a maximum of 350 watts. The effects of air and ultrasonic agitation on hardness, ductility, tensile strength, composition, structure, surface topography, limiting current density, cathode current efficiency and macro-throwing power were determined. Transmission and scanning electron microscopy, electron-probe microanalysis and atomic absorption spectrophotometry have been employed to study the nickel alloy deposits produced. The results obtained show that the use of Ultrasonics increased significantly the hardness of both alloy deposits and altered their composition by decreasing the cobalt and iron contents from nickel-cobalt and nickeliron solutions respectively. The ductility of coatings improved but the tensile strength did not change very much. Ultrasonic agitation gave larger grained deposits than air and they seemed to have a lower stress. Dull cobalt-nickel deposits had a similar pyramidal surface topography regardless of the type of agitation but the bright appearance of the nickel-iron was destroyed by ultrasonic agitation; an unusual ribbed pattern was produced. The use of ultrasonic agitation permitted approximately a twofold increase in the plating current density at which sound deposits could be achieved but there was only a slight increase in cathode current efficiency. Macro-throwing power of the solutions was increased slightly by the use of ultrasonic agitation. ultrasonic agitation is an expensive means of agitating plating Solutions and would be worthwhile only if significant improvements in properties could be achieved. The simultaneous improvement in hardness and ductility is a novel feature that should have useful engineering applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Established RlNm5F and lN111 R1 and newly available HlT-T15 and UMR 407/3 B-cell lines have been successfully maintained in vitro. With the exclusion of UMR 407/3 cells, all lines were continuously propagable. Doubling times and plating efficiencies for HlT-T15, RlNm5F, lN111 R1 and UMR 407/3 cells were 20 hours and 85%, 31 hours and 76%, 24 hours and 80% and 38 hours and 94% respectively. All the cell lines were anchorage dependent, but only UMR 407/3 cells grew to confluence. Only HlT-T15 and UMR 407/3 cells produced a true insulin response to glucose but glucose markedly increased the rate of D-[U14C]glucose oxidation by all the cell lines. Glucose induced insulin release from HlT-T15 cells was biphasic with an exaggerated first phase. Insulin release from HlT-T15, RlNm5F and IN111 R1 cells was stimulated by amino acids and sulphonylureas. Glucagon stimulated insulin release from HlT-T15 and RlNm5F cells while somatostatin and pancreatic polypeptide inhibited release. These observations suggest that net insulin release from the whole islet may be the result of significant paracrine interaction. HlT-T15 and RlNm5F cell insulin release was stimulated by forskolin and inhibited by imidazole. Ca2+ channel blockade and calmodulin inhibition suppressed insulin release from HlT-T15, RlNm5F and IN111 R1 cells. In addition phorbol esters stimulated insulin release from RlNm5F cells. These data implicate cAMP, Ca2+ and protein kinase-C in the regulation of insulin release from cultured B-cells. Acetylcholine increased insulin release from HlT-T15 and RlNm5F cells. Inhibition of the response by atropine confirmed the involvement of muscarinic receptors. HlT-T15 cell insulin release was also inhibited by adrenaline. These observations suggest a possible role for the autonomic nervous system in the modulation of insulin release. Preliminary studies with a human insulinoma maintained in monolayer culture have demonstrated a limited life span of some seven weeks, a continuous low level of insulin release but no insulin response to glucose challenge.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: For tibial fractures, the decision to fix a concomitant fibular fracture is undertaken on a case-by-case basis. To aid in this clinical decision-making process, we investigated whether loss of integrity of the fibula significantly destabilises midshaft tibial fractures, whether fixation of the fibula restores stability to the tibia, and whether removal of the fibula and interosseous membrane for expediency in biomechanical testing significantly influences tibial interfragmentary mechanics. Methods: Tibia/fibula pairs were harvested from six cadaveric donors with the interosseous membrane intact. A tibial osteotomy fracture was fixed by reamed intramedullary (IM) nailing. Axial, torsion, bending, and shear tests were completed for four models of fibular involvement: intact fibula, osteotomy fracture, fibular plating, and resected fibula and interosseous membrane. Findings: Overall construct stiffness decreased slightly with fibular osteotomy compared to intact bone, but this change was not statistically significant. Under low loads, the influence of the fibula on construct stability was only statistically significant in torsion (large effect size). Fibular plating stiffened the construct slightly, but this change was not statistically significant compared to the fibular osteotomy case. Complete resection of the fibula and interosseous membrane significantly decreased construct torsional stiffness only (large effect size). Interpretation: These results suggest that fixation of the fibula may not contribute significantly to the stability of diaphyseal tibial fractures and should not be undertaken unless otherwise clinically indicated. For testing purposes, load-sharing through the interosseous membrane contributes significantly to overall construct mechanics, especially in torsion, and we recommend preservation of these structures when possible.