897 resultados para distributed storage


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to evaluate the second-generation OptiMal test for malaria diagnosis under various storage conditions. It detected all the positive samples, except for two Plasmodium malariae samples. Further research evaluating diverse environmental conditions are important for ICT test applicability in Brazilian malaria areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis submitted in fulfilment of the requirements for the Degree of Master of Science in Computer Science

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of devices based on heterostructured thin films of biomolecules conveys a huge contribution on biomedical field. However, to achieve high efficiency of these devices, the storage of water molecules into these heterostructures, in order to maintain the biological molecules hydrated, is mandatory. Such hydrated environment may be achieved with lipids molecules which have the ability to rearrange spontaneously into vesicles creating a stable barrier between two aqueous compartments. Yet it is necessary to find conditions that lead to the immobilization of whole vesicles on the heterostructures. In this work, the conditions that govern the deposition of open and closed liposomes of 1.2-dipalmitoyl-sn-Glycero-3-[Phospho-rac-(1-glycerol)] (sodium Salt) (DPPG) onto polyelectrolytes cushions prepared by the layer-by-layer (LbL) method were analyzed. Electronic transitions of DPPG molecules as well as absorption coefficients were obtained by vacuum ultraviolet spectroscopy, while the elemental composition of the heterostructures was characterized by x-ray photoelectron spectroscopy (XPS). The presence of water molecules in the films was inferred by XPS and infrared spectroscopy. Quartz crystal microbalance (QCM) data analysis allowed to conclude that, in certain cases, the DPPG adsorbed amount is dependent of the bilayers number already adsorbed. Moreover, the adsorption kinetics curves of both adsorbed amount and surface roughness allowed to determine the kinetics parameters that are related with adsorption processes namely, electrostatic forces, liposomes diffusion and lipids re-organization on surface. Scaling exponents attained from atomic force microscopy images statistical analysis demonstrate that DPPG vesicles adsorption mechanism is ruled by the diffusion Villain model confirming that adsorption is governed by electrostatic forces. The power spectral density treatment enabled a thorough description of the accessible surface of the samples as well as of its inner structural properties. These outcomes proved that surface roughness influences the adsorption of DPPG liposomes onto surfaces covered by a polyelectrolyte layer. Thus, low roughness was shown to induce liposome rupture creating a lipid bilayer while high roughness allows the adsorption of whole liposomes. In addition, the fraction of open liposomes calculated from the normalized maximum adsorbed amounts decreases with the cushion roughness increase, allowing us to conclude that the surface roughness is a crucial variable that governs the adsorption of open or whole liposomes. This conclusion is fundamental for the development of well-designed sensors based on functional biomolecules incorporated in liposomes. Indeed, LbL films composed of polyelectrolytes and liposomes with and without melanin encapsulated were successfully applied to sensors of olive oil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thermal Energy Storage Unit (ESU) could be used to attenuate inherent temperature fluctuations of a cold finger, either from a cryocooler working or due to sudden income heat bursts. An ESU directly coupled to the cold source acts as a thermal buffer temporarily increasing its cooling capacity and providing a better thermal stability of the cold finger (“Power Booster mode”). The energy storage units presented here use an enthalpy reservoir based on the high latent heat of the liquid-vapour transition of neon in the temperature range 38 - 44 K to store up to 900 J, and that uses a 6 liters expansion volume at RT in order to work as a closed system. Experimental results in the power booster mode will be described: in this case, the liquid neon cell was directly coupled to the cold finger of the working cryocooler, its volume (12 cm3) allowing it to store 450 J at around 40 K. 10 W heat bursts were applied, leading to liquid evaporation, with quite reduced temperature changes. The liquid neon reservoir can also work as a temporary cold source to be used after stopping the cryocooler, allowing for a vibration-free environment. In this case the enthalpy reservoir implemented (24 cm3) was linked to the cryocooler cold finger through a gas gap heat switch for thermal coupling/decoupling of the cold finger. We will show that, by controlling the enthalpy reservoir’s pressure, 900 J can be stored at a constant temperature of 40 K as in a triple-point ESU.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryocoolers have been progressively replacing the use of the stored cryogens in cryogenic chains used for detector cooling, thanks to their higher and higher reliability. However, the mechanical vibrations, the electromagnetic interferences and the temperature fluctuations inherent to their functioning could reduce the sensor’s sensitivity. In order to minimize this problem, compact thermal energy storage units (ESU) are studied, devices able to store thermal energy without significant temperature increase. These devices can be used as a temporary cold source making it possible to turn the cryocooler OFF providing a proper environment for the sensor. A heat switch is responsible for the thermal decoupling of the ESU from the cryocooler’s temperature that increases when turned OFF. In this work, several prototypes working around 40 K were designed, built and characterized. They consist in a low temperature cell that contains the liquid neon connected to an expansion volume at room temperature for gas storage during the liquid evaporation phase. To turn this system insensitive to the gravity direction, the liquid is retained in the low temperature cell by capillary effect in a porous material. Thanks to pressure regulation of the liquid neon bath, 900 J were stored at 40K. The higher latent heat of the liquid and the inexistence of triple point transitions at 40 K turn the pressure control during the evaporation a versatile and compact alternative to an ESU working at the triple point transitions. A quite compact second prototype ESU directly connected to the cryocooler cold finger was tested as a temperature stabilizer. This device was able to stabilize the cryocooler temperature ((≈ 40K ±1 K) despite sudden heat bursts corresponding to twice the cooling power of the cryocooler. This thesis describes the construction of these devices as well as the tests performed. It is also shown that the thermal model developed to predict the thermal behaviour of these devices, implemented as a software,describes quite well the experimental results. Solutions to improve these devices are also proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryocoolers have been progressively replacing the use of the stored cryogens in cryogenic chains used for detector cooling, thanks to their higher and higher reliability. However, the mechanical vibrations, the electromagnetic interferences and the temperature fluctuations inherent to their functioning could reduce the sensor’s sensitivity. In order to minimize this problem, compact thermal energy storage units (ESU) are studied, devices able to store thermal energy without significant temperature increase. These devices can be used as a temporary cold source making it possible to turn the cryocooler OFF providing a proper environment for the sensor. A heat switch is responsible for the thermal decoupling of the ESU from the cryocooler’s temperature that increases when turned OFF. In this work, several prototypes working around 40 K were designed, built and characterized. They consist in a low temperature cell that contains the liquid neon connected to an expansion volume at room temperature for gas storage during the liquid evaporation phase. To turn this system insensitive to the gravity direction, the liquid is retained in the low temperature cell by capillary effect in a porous material. Thanks to pressure regulation of the liquid neon bath, 900 J were stored at 40K. The higher latent heat of the liquid and the inexistence of triple point transitions at 40 K turn the pressure control during the evaporation a versatile and compact alternative to an ESU working at the triple point transitions. A quite compact second prototype ESU directly connected to the cryocooler cold finger was tested as a temperature stabilizer. This device was able to stabilize the cryocooler temperature ((≈ 40K ±1 K) despite sudden heat bursts corresponding to twice the cooling power of the cryocooler. This thesis describes the construction of these devices as well as the tests performed. It is also shown that the thermal model developed to predict the thermal behaviour of these devices,implemented as a software, describes quite well the experimental results. Solutions to improve these devices are also proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The “CMS Safety Closing Sensors System” (SCSS, or CSS for brevity) is a remote monitoring system design to control safety clearance and tight mechanical movements of parts of the CMS detector, especially during CMS assembly phases. We present the different systems that makes SCSS: its sensor technologies, the readout system, the data acquisition and control software. We also report on calibration and installation details, which determine the resolution and limits of the system. We present as well our experience from the operation of the system and the analysis of the data collected since 2008. Special emphasis is given to study positioning reproducibility during detector assembly and understanding how the magnetic fields influence the detector structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The emergence of drug resistance is one of the main problems concerning malaria treatment. The use of counterfeit and/or substandard antimalarial drugs can contribute to the development of parasite resistance. Thus, the aim of this study was to evaluate the quality of antimalarial drugs distributed in Brazil. METHODS: Samples containing chloroquine phosphate, mefloquine hydrochloride, primaquine phosphate, and quinine sulfate tablets were delivered to the Rio de Janeiro central storeroom (CENADI), state storerooms (SS), and Basic Health Units (BHUs) in the north region of Brazil - a total of 10 sample sets. After 5 months of storage, the samples were collected, and in vitro quality control analyses according to official and published methods were performed. RESULTS: Inadequate drug storage conditions were found in two SS and in all BHUs evaluated. There were no quality deviations found in the chloroquine samples. The quinine samples exhibited weight variation above the allowed limits. The primaquine samples were found to have packaging deficiency. The release of mefloquine in samples from some regions showed a statistically significant difference when compared with the CENADI samples. CONCLUSIONS: It is important to periodically evaluate the quality and storage conditions of essential drugs. The quality deviations found with the primaquine and quinine samples are not related to storage conditions and must be addressed urgently. The decreased mefloquine release from tablets is related to formulation problems or influenced by inadequate storage conditions, prompting further investigation. Even with the mentioned problems, the samples would probably not contribute to resistant parasite selection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scarcity of fuels, changes in environmental policy and in society increased the interest in generating electric energy from renewable energy sources (RES) for a sustainable energy supply in the future. The main problem of RES as solar and wind energy, which represent a main pillar of this transition, is that they cannot supply constant power output. This results inter alia in an increased demand of backup technologies as batteries to assure electricity system safety. The diffusion of energy storage technologies is highly dependent on the energy system and transport transition pathways which might lead to a replacement or reconfiguration of embedded socio-technical practices and regimes (by creating new standards or dominant designs, changing regulations, infrastructure and user patterns). The success of this technology is dependent on hardly predictable future technical advances, actor preferences, development of competing technologies and designs, diverging interests of actors, future cost efficiencies, environmental performance, the evolution of market demand and design and evolution of our society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hospital pharmacy in large and advanced institutions has evolved from a simple storage and distribution unit into a highly specialized manipulation and dispensation center, responsible for the handling of hundreds of clinical requests, many of them unique and not obtainable from commercial companies. It was therefore quite natural that in many environments, a manufacturing service was gradually established, to cater to both conventional and extraordinary demands of the medical staff. That was the case of Hospital das Clinicas, where multiple categories of drugs are routinely produced inside the pharmacy. However, cost-containment imperatives dictate that such activities be reassessed in the light of their efficiency and essentiality. METHODS: In a prospective study, the output of the Manufacturing Service of the Central Pharmacy during a 12-month period was documented and classified into three types. Group I comprised drugs similar to commercially distributed products, Group II included exclusive formulations for routine consumption, and Group III dealt with special demands related to clinical investigations. RESULTS: Findings for the three categories indicated that these groups represented 34.4%, 45.3%, and 20.3% of total manufacture orders, respectively. Costs of production were assessed and compared with market prices for Group 1 preparations, indicating savings of 63.5%. When applied to the other groups, for which direct equivalent in market value did not exist, these results would suggest total yearly savings of over 5 100 000 US dollars. Even considering that these calculations leave out many components of cost, notably those concerning marketing and distribution, it might still be concluded that at least part of the savings achieved were real. CONCLUSIONS: The observed savings, allied with the convenience and reliability with which the Central Pharmacy performed its obligations, support the contention that internal manufacture of pharmaceutical formulations was a cost-effective alternative in the described setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The way in which electricity networks operate is going through a period of significant change. Renewable generation technologies are having a growing presence and increasing penetrations of generation that are being connected at distribution level. Unfortunately, a renewable energy source is most of the time intermittent and needs to be forecasted. Current trends in Smart grids foresee the accommodation of a variety of distributed generation sources including intermittent renewable sources. It is also expected that smart grids will include demand management resources, widespread communications and control technologies required to use demand response are needed to help the maintenance in supply-demand balance in electricity systems. Consequently, smart household appliances with controllable loads will be likely a common presence in our homes. Thus, new control techniques are requested to manage the loads and achieve all the potential energy present in intermittent energy sources. This thesis is focused on the development of a demand side management control method in a distributed network, aiming the creation of greater flexibility in demand and better ease the integration of renewable technologies. In particular, this work presents a novel multi-agent model-based predictive control method to manage distributed energy systems from the demand side, in presence of limited energy sources with fluctuating output and with energy storage in house-hold or car batteries. Specifically, here is presented a solution for thermal comfort which manages a limited shared energy resource via a demand side management perspective, using an integrated approach which also involves a power price auction and an appliance loads allocation scheme. The control is applied individually to a set of Thermal Control Areas, demand units, where the objective is to minimize the energy usage and not exceed the limited and shared energy resource, while simultaneously indoor temperatures are maintained within a comfort frame. Thermal Control Areas are overall thermodynamically connected in the distributed environment and also coupled by energy related constraints. The energy split is performed based on a fixed sequential order established from a previous completed auction wherein the bids are made by each Thermal Control Area, acting as demand side management agents, based on the daily energy price. The developed solutions are explained with algorithms and are applied to different scenarios, being the results explanatory of the benefits of the proposed approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Existing wireless networks are characterized by a fixed spectrum assignment policy. However, the scarcity of available spectrum and its inefficient usage demands for a new communication paradigm to exploit the existing spectrum opportunistically. Future Cognitive Radio (CR) devices should be able to sense unoccupied spectrum and will allow the deployment of real opportunistic networks. Still, traditional Physical (PHY) and Medium Access Control (MAC) protocols are not suitable for this new type of networks because they are optimized to operate over fixed assigned frequency bands. Therefore, novel PHY-MAC cross-layer protocols should be developed to cope with the specific features of opportunistic networks. This thesis is mainly focused on the design and evaluation of MAC protocols for Decentralized Cognitive Radio Networks (DCRNs). It starts with a characterization of the spectrum sensing framework based on the Energy-Based Sensing (EBS) technique considering multiple scenarios. Then, guided by the sensing results obtained by the aforementioned technique, we present two novel decentralized CR MAC schemes: the first one designed to operate in single-channel scenarios and the second one to be used in multichannel scenarios. Analytical models for the network goodput, packet service time and individual transmission probability are derived and used to compute the performance of both protocols. Simulation results assess the accuracy of the analytical models as well as the benefits of the proposed CR MAC schemes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the report for the unit “Métodos Interactivos de Participação e Decisão A” (Interactive methods of participation and decision A), coordinated by Prof. Lia Maldonado Teles de Vasconcelos and Prof. Nuno Miguel Ribeiro Videira Costa. This unit was provided for the PhD Program in Technology Assessment in 2015/2016.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO - A dor, incómodo ou desconforto ao nível músculo-esquelético, sobretudo devido a situações e/ou postos de trabalho com elevadas exigências ao nível postural, de aplicação de força, de repetitividade ou por incorrecta distribuição das pausas, é aceite como um indicador de situações de risco passíveis de se encontrarem na génese de lesões músculo- -esqueléticas ligadas ao trabalho (LMELT) (Stuart-Buttle, 1994). No sentido de avaliar a prevalência de sintomas de LME, efectuou-se um estudo numa grande empresa da indústria de componentes para automóveis na região de Lisboa durante o ano de 2001. Utilizou-se um instrumento de recolha de informação construído a partir de uma adaptação do questionário nórdico músculo-esquelético (QNM) (Kuorinka et al., 1987). Com o apoio do serviço de saúde ocupacional da referida empresa, o questionário foi entregue a todos os trabalhadores, obtendo-se uma taxa de respondentes de 63,2% (n = 574). A população em estudo é maioritariamente do sexo feminino (83,9%), tem idades compreendidas entre os 18 e os 65 anos e a classe modal situa-se entre os 26 e os 33 anos (23,3%). Os resultados evidenciam uma alta prevalência de sintomatologia de LME e diferenças significativas de sintomas entre as categorias profissionais (1) operadores de máquina de costura, (2) trabalhadores dos armazéns e de transporte de mercadorias e (3) trabalhadores da logística, qualidade e escritórios. Os operadores apresentam índices superiores e diferentes (p < 0,05) de sintomatologia nos últimos doze meses ao nível da região cervical, ombros, cotovelos, ancas/coxas, pernas/joelhos e tornozelos/pés e nos punhos nos últimos sete dias. No presente estudo, a análise dos dados obtidos parece indicar que a natureza e as características da actividade de trabalho do grupo profissional operadores de máquina de costura (flexão cervical > 20°, trabalho muscular predominantemente estático ao nível da articulação dos ombros, elevação dos membros superiores > 45°, ortostatismo e exigências elevadas ao nível dos punhos/mãos) estão implicadas no desencadear da sintomatologia auto- -referida.