905 resultados para complete spinal cord injury


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Monitoring pathology/regeneration in experimental models of de-/remyelination requires an accurate measure not only of functional changes but also of the amount of myelin. We tested whether X-ray diffraction (XRD), which measures periodicity in unfixed myelin, can assess the structural integrity of myelin in fixed tissue. From laboratories involved in spinal cord injury research and in studying the aging primate brain, we solicited "blind" samples and used an electronic detector to record rapidly the diffraction patterns (30 min each pattern) from them. We assessed myelin integrity by measuring its periodicity and relative amount. Fixation of tissue itself introduced +/-10% variation in periodicity and +/-40% variation in relative amount of myelin. For samples having the most native-like periods, the relative amounts of myelin detected allowed distinctions to be made between normal and demyelinating segments, between motor and sensory tracts within the spinal cord, and between aged and young primate CNS. Different periodicities also allowed distinctions to be made between samples from spinal cord and nerve roots and between well-fixed and poorly fixed samples. Our findings suggest that, in addition to evaluating the effectiveness of different fixatives, XRD could also be used as a robust and rapid technique for quantitating the relative amount of myelin among spinal cords and other CNS tissue samples from experimental models of de- and remyelination.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Serum protein S-100B determinations have been widely proposed in the past as markers of traumatic brain injury and used as a predictor of injury severity and outcome. The purpose of this prospective observational case series was therefore to determine S-100B serum levels in patients with isolated injuries to the back. METHODS: Between 1 February and 1 May 2008, serum samples for S-100B analysis were obtained within 1 hour of injury from 285 trauma patients. All patients with a head injury, polytrauma, and intoxicated patients were excluded to select isolated injuries to the spine. 19 patients with isolated injury of the back were included. Serum samples for S-100B analysis and CT spine were obtained within 1 hours of injury. RESULTS: CT scans showed vertebral fractures in 12 of the 19 patients (63%). All patients with fractures had elevated S-100B levels. Amongst the remaining 7 patients without a fracture, only one patient with a severe spinal contusion had an S-100B concentration above the reference limit. The mean S-100B value of the group with fractures was more than 4 times higher than in the group without fractures (0.385 vs 0.087 mug/L, p = 0.0097). CONCLUSION: Our data, although limited due to a very small sample size, suggest that S-100B serum levels might be useful for the diagnosis of acute vertebral body and spinal cord injury with a high negative predictive power. According to the literature, the highest levels of serum S-100B are found when large bones are fractured. If a large prospective study confirms our findings, determining the S-100B level may contribute to more selective use of CT and MRI in spinal trauma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Disuse osteoporosis is a problem for people with spinal cord injury or stroke, patients confined to bed rest, and astronauts exposed to microgravity. Unlike most mammals however, bears have been shown to prevent bone loss during hibernation, a seasonal period of disuse. Similarly, studies in ground squirrels indicate preservation of whole bone strength during hibernation, though evidence suggests there may be some increased osteocytic osteolysis. Uncovering the mechanism by which these animals prevent bone loss during hibernation could lead to an improved treatment for osteoporosis in humans. Marmots are a good animal model for these studies because they are small enough to easily house in an animal facility yet still utilize intracortical remodeling like humans and bears, and unlike smaller rodents like squirrels. Marmots preserve bone mechanical and microstructural properties during hibernation. Bone mechanical and geometrical properties are not diminished in post-hibernation samples compared to pre-hibernation samples. Mineral content, measured by ash fraction, was higher in post-hibernation samples (p = 0.0003). Haversian porosity as well as remodeling cavity density were not different (p > 0.38) between pre- and post-hibernation samples. Similarly, average lacunar area, lacunar density, and lacunar porosity were all lower (p < 0.0001) in post-hibernation samples. Trabecular thickness was larger in posthibernation samples (p = 0.0058). Bone volume fraction was not different between groups, but approached significance (p = 0.0725). Further studies in marmots and other hibernators could help uncover the mechanism that allows hibernators to prevent disuse osteoporosis during hibernation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Acute central nervous system (CNS) injuries such as spinal cord injury, traumatic brain injury, autoimmune encephalomyelitis, and ischemic stroke are associated with significant morbidity, mortality, and health care costs worldwide. Preliminary research has shown potential neuroprotection associated with adult tissue derived stem/progenitor cell based therapies. While initial research indicated that engraftment and transdifferentiation into neural cells could explain the observed benefit, the exact mechanism remains controversial. A second hypothesis details localized stem/progenitor cell engraftment with alteration of the loco-regional milieu; however, the limited rate of cell engraftment makes this theory less likely. There is a growing amount of preclinical data supporting the idea that, after intravenous injection, stem/progenitor cells interact with immunologic cells located in organ systems distant to the CNS, thereby altering the systemic immunologic/inflammatory response. Such distant cell "bioreactors" could modulate the observed post-injury pro-inflammatory environment and lead to neuroprotection. In this review, we discuss the current literature detailing the above mechanisms of action for adult stem/progenitor cell based therapies in the CNS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To determine whether body weight, body condition score, or various body dimensions were associated with acute thoracolumbar intervertebral disk extrusion or protrusion and whether any of these factors were associated with severity of clinical signs in Dachshunds. DESIGN Cross-sectional clinical study. ANIMALS 75 Dachshunds with (n = 39) or without (36) acute thoracolumbar intervertebral disk extrusion or protrusion. PROCEDURES Signalment, various body measurements, body weight, body condition score, and spinal cord injury grade were recorded at the time of initial examination. RESULTS Mean T1-S1 distance and median tuber calcaneus-to-patellar tendon (TC-PT) distance were significantly shorter in affected than in unaffected dogs. A 1-cm decrease in T1-S1 distance was associated with a 2.1-times greater odds of being affected, and a 1-cm decrease in TC-PT distance was associated with an 11.1-times greater odds of being affected. Results of multivariable logistic regression also indicated that affected dogs were taller at the withers and had a larger pelvic circumference than unaffected dogs, after adjusting for other body measurements. Results of ordinal logistic regression indicated that longer T1-S1 distance, taller height at the withers, and smaller pelvic circumference were associated with more severe spinal cord injury. CONCLUSIONS AND CLINICAL RELEVANCE Results suggest that certain body dimensions may be associated with acute thoracolumbar intervertebral disk extrusion or protrusion in Dachshunds and, in affected dogs, with severity of neurologic dysfunction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is a noninvasive technique for quantitative assessment of the integrity of blood-brain barrier and blood-spinal cord barrier (BSCB) in the presence of central nervous system pathologies. However, the results of DCE-MRI show substantial variability. The high variability can be caused by a number of factors including inaccurate T1 estimation, insufficient temporal resolution and poor contrast-to-noise ratio. My thesis work is to develop improved methods to reduce the variability of DCE-MRI results. To obtain fast and accurate T1 map, the Look-Locker acquisition technique was implemented with a novel and truly centric k-space segmentation scheme. In addition, an original multi-step curve fitting procedure was developed to increase the accuracy of T1 estimation. A view sharing acquisition method was implemented to increase temporal resolution, and a novel normalization method was introduced to reduce image artifacts. Finally, a new clustering algorithm was developed to reduce apparent noise in the DCE-MRI data. The performance of these proposed methods was verified by simulations and phantom studies. As part of this work, the proposed techniques were applied to an in vivo DCE-MRI study of experimental spinal cord injury (SCI). These methods have shown robust results and allow quantitative assessment of regions with very low vascular permeability. In conclusion, applications of the improved DCE-MRI acquisition and analysis methods developed in this thesis work can improve the accuracy of the DCE-MRI results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Upper limb function impairment is one of the most common sequelae of central nervous system injury, especially in stroke patients and when spinal cord injury produces tetraplegia. Conventional assessment methods cannot provide objective evaluation of patient performance and the tiveness of therapies. The most common assessment tools are based on rating scales, which are inefficient when measuring small changes and can yield subjective bias. In this study, we designed an inertial sensor-based monitoring system composed of five sensors to measure and analyze the complex movements of the upper limbs, which are common in activities of daily living. We developed a kinematic model with nine degrees of freedom to analyze upper limb and head movements in three dimensions. This system was then validated using a commercial optoelectronic system. These findings suggest that an inertial sensor-based motion tracking system can be used in patients who have upper limb impairment through data integration with a virtual reality-based neuroretation system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three-dimensional kinematic analysis provides quantitative assessment of upper limb motion and is used as an outcome measure to evaluate movement disorders. The aim of the present study is to present a set of kinematic metrics for quantifying characteristics of movement performance and the functional status of the subject during the execution of the activity of daily living (ADL) of drinking from a glass. Then, the objective is to apply these metrics in healthy people and a population with cervical spinal cord injury (SCI), and to analyze the metrics ability to discriminate between healthy and pathologic people. 19 people participated in the study: 7 subjects with metameric level C6 tetraplegia, 4 subjects with metameric level C7 tetraplegia and 8 healthy subjects. The movement was recorded with a photogrammetry system. The ADL of drinking was divided into a series of clearly identifiable phases to facilitate analysis. Metrics describing the time of the reaching phase, the range of motion of the joints analyzed, and characteristics of movement performance such as the efficiency, accuracy and smoothness of the distal segment and inter-joint coordination were obtained. The performance of the drinking task was more variable in people with SCI compared to the control group in relation to the metrics measured. Reaching time was longer in SCI groups. The proposed metrics showed capability to discriminate between healthy and pathologic people. Relative deficits in efficiency were larger in SCI people than in controls. These metrics can provide useful information in a clinical setting about the quality of the movement performed by healthy and SCI people during functional activities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With the growing body of research on traumatic brain injury and spinal cord injury, computational neuroscience has recently focused its modeling efforts on neuronal functional deficits following mechanical loading. However, in most of these efforts, cell damage is generally only characterized by purely mechanistic criteria, function of quantities such as stress, strain or their corresponding rates. The modeling of functional deficits in neurites as a consequence of macroscopic mechanical insults has been rarely explored. In particular, a quantitative mechanically based model of electrophysiological impairment in neuronal cells has only very recently been proposed (Jerusalem et al., 2013). In this paper, we present the implementation details of Neurite: the finite difference parallel program used in this reference. Following the application of a macroscopic strain at a given strain rate produced by a mechanical insult, Neurite is able to simulate the resulting neuronal electrical signal propagation, and thus the corresponding functional deficits. The simulation of the coupled mechanical and electrophysiological behaviors requires computational expensive calculations that increase in complexity as the network of the simulated cells grows. The solvers implemented in Neurite-explicit and implicit-were therefore parallelized using graphics processing units in order to reduce the burden of the simulation costs of large scale scenarios. Cable Theory and Hodgkin-Huxley models were implemented to account for the electrophysiological passive and active regions of a neurite, respectively, whereas a coupled mechanical model accounting for the neurite mechanical behavior within its surrounding medium was adopted as a link between lectrophysiology and mechanics (Jerusalem et al., 2013). This paper provides the details of the parallel implementation of Neurite, along with three different application examples: a long myelinated axon, a segmented dendritic tree, and a damaged axon. The capabilities of the program to deal with large scale scenarios, segmented neuronal structures, and functional deficits under mechanical loading are specifically highlighted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En personas que padecen una Lesión Medular cervical, la función de los miembros superiores se ve afectada en mayor o menor medida, dependiendo fundamentalmente del nivel de la lesión y de la severidad de la misma. El déficit en la función del miembro superior hace que la autonomía e independencia de las personas se vea reducida en la ejecución de Actividades de la Vida Diaria. En el entorno clínico, la valoración de la función del miembro superior se realiza principalmente con escalas clínicas. Algunas de ellas valoran el nivel de dependencia o independencia en la ejecución de Actividades de la Vida Diaria, como, por ejemplo, el índice de Barthel y la escala FIM (Medida de la Independencia Funcional). Otras escalas, como Jebsen-Taylor Hand Function, miden la función del miembro superior valorando la destreza y la habilidad en la ejecución de determinadas tareas funcionales. Estas escalas son generales, es decir, se pueden aplicar a distintas poblaciones de sujetos y a la presencia de distintas patologías. Sin embargo, existen otras escalas desarrolladas específicamente para valorar una patología concreta, con el objetivo de hacer las evaluaciones funcionales más sensibles a cambios. Un ejemplo es la escala Spinal Cord Independence Measure (SCIM), desarrollada para valorar Lesión Medular. Las escalas clínicas son instrumentos de medida estandarizados, válidos para su uso en el entorno clínico porque se han validado en muestras grandes de pacientes. No obstante, suelen poseer una elevada componente de subjetividad que depende principalmente de la persona que puntúa el test. Otro aspecto a tener en cuenta, es que la sensibilidad de las escalas es alta, fundamentalmente, a cambios groseros en el estado de salud o en la función del miembro superior, de forma que cambios sutiles en el sujeto pueden no ser detectados. Además, en ocasiones, poseen saturaciones en el sistema de puntuación, de forma que mejorías que se puedan producir por encima de un determinado umbral no son detectadas. En definitiva, estas limitaciones hacen que las escalas clínicas no sean suficientes, por sí mismas, para evaluar estrategias motoras del miembro superior durante la ejecución de movimientos funcionales, siendo necesaria la búsqueda de instrumentos de medida que aporten objetividad, complementen las valoraciones y, al mismo tiempo, intenten solventar las limitaciones que poseen las escalas. Los estudios biomecánicos son ejemplos de métodos objetivos, en los que diversas tecnologías se pueden utilizar para recoger información de los sujetos. Una concreción de estos estudios son los estudios cinemáticos. Mediante tecnología optoelectrónica, inercial o electromagnética, estos estudios proporcionan información objetiva acerca del movimiento realizado por los sujetos, durante la ejecución de tareas concretas. Estos sistemas de medida proporcionan grandes cantidades de datos que carecen de una interpretación inmediata. Estos datos necesariamente deben ser tratados y reducidos a un conjunto de variables que, a priori, posean una interpretación más sencilla para ser utilizados en la práctica clínica. Estas han sido las principales motivaciones de esta investigación. El objetivo principal fue proponer un conjunto de índices cinemáticos que, de forma objetiva, valoren la función del miembro superior; y validar los índices propuestos en poblaciones con Lesión Medular, para su uso como instrumentos de valoración en el entorno clínico. Esta tesis se enmarca dentro de un proyecto de investigación: HYPER (Hybrid Neuroprosthetic and Neurorobotic Devices for Functional Compensation and Rehabilitation of Motor Disorders, referencia CSD2009-00067 CONSOLIDER INGENIO 2010). Dentro de este proyecto se lleva a cabo investigación en el desarrollo de modelos, para determinar los requisitos biomecánicos y los patrones de movimiento de los miembros superiores en sujetos sanos y personas con lesión medular. Además, se realiza investigación en la propuesta de nuevos instrumentos de evaluación funcional en el campo de la rehabilitación de los miembros superiores. ABSTRACT In people who have suffered a cervical Spinal Cord Injury, upper limbs function is affected to a greater or lesser extent, depending primarily on the level of the injury and the severity of it. The deficit in the upper limb function reduces the autonomy and independence of persons in the execution of Activities of Daily Living. In the clinical setting, assessment of upper limb function is mainly performed based on clinical scales. Some value the level of dependence or independence in performing activities of daily living, such as the Barthel Index and the FIM scale (Functional Independence Measure). Other scales, such as the Jebsen-Taylor Hand Function, measure upper limb function in terms of the skill and ability to perform specific functional tasks. These scales are general, so can be applied to different populations of subjects and the presence of different pathologies. However, there are other scales developed for a specific injury, in order to make the functional assessments more sensitive to changes. An example is the Spinal Cord Independence Measure (SCIM), developed for people with Spinal Cord Injury. The clinical scales are standardized instruments measure, valid for use in the clinical setting because they have been validated in large patient samples. However, they usually have a high level of subjectivity which mainly depends on the person who scores the test. Another aspect to take into account is the high sensitivity of the scales mainly to gross changes in the health status or upper limb function, so that subtle changes in the subject may not be detected. Moreover, sometimes, have saturations in the scoring system, so that improvements which may occur above a certain threshold are not detected. For these reasons, clinical scales are not enough, by themselves, to assess motor strategies used during movements. So, it’s necessary to find measure instruments that provide objectivity, supplement the assessments and, at the same time, solving the limitations that scales have. Biomechanical studies are examples of objective methods, in which several technologies can be used to collect information from the subjects. One kind of these studies is the kinematic movement analysis. By means of optoelectronics, inertial and electromagnetic technology, these studies provide objective information about the movement performed by the subjects during the execution of specific tasks. These systems provide large quantities of data without easy and intuitive interpretation. These data must necessarily be treated and reduced to a set of variables that, a priori, having a simpler interpretation for their use in the clinical practice. These were the main motivations of this research. The main objective was to propose a set of kinematic indices, or metrics that, objectively, assess the upper limb function and validate the proposed rates in populations with Spinal Cord Injury, for use as assessment tools in the clinical setting. This dissertation is framed within a research project: HYPER (Neurorobotic Devices for Functional Compensation and Rehabilitation of Motor Disorders, grant CSD2009- 00067 CONSOLIDER INGENIO 2010). Within this research project, research is conducted in relation to the biomechanical models development for determining the biomechanical requirements and movement patterns of the upper limb in healthy and people with Spinal Cord Injury. Moreover, research is conducted with respect to the proposed of new functional assessment instruments in the field of upper limb rehabilitation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La marcha humana es el mecanismo de locomoción por el cual el cuerpo humano se traslada en línea recta gracias a una serie de movimientos coordinados de la pelvis y de las articulaciones del miembro inferior. Frecuentemente se encuentra influenciada por factores biomecánicos, anatómicos o patologías del sistema neuromusculoesquelético que modifican la forma de caminar de cada individuo. La lesión de médula espinal es una de las patologías que afectan el desarrollo normal de los patrones de la marcha por alteración de la movilidad, de la sensibilidad o del sistema nervioso autónomo. Aunque la lesión medular afecta otras funciones, además de la pérdida de función motora y sensorial, la recuperación de la capacidad de caminar es la mayor prioridad identificada por los pacientes durante la rehabilitación. Por ello, el desarrollo de dispositivos que faciliten la rehabilitación o compensación de la marcha es uno de los principales objetivos de diferentes grupos de investigación y empresas. En el contexto del proyecto Hybrid Technological Platform for Rehabilitation, Functional Compensation and Training of Gait in Spinal Cord Injury Patients se ha desarrollado un dispositivo que combina una órtesis activa (exoesqueleto) y un andador motorizado. Este sistema, como otros dispositivos, tiene el movimiento humano como estándar de referencia, no obstante no se evalúa de manera habitual, cómo es el patrón de la marcha reproducido y su similitud o diferencias con la marcha humana, o las modificaciones o adaptaciones en la interacción con el cuerpo del paciente. El presente estudio trata de examinar las características de la marcha normal en diversos grupos de población, y las diferencias con el patrón de marcha lenta. Finalmente, se pretende evaluar qué modificaciones y adaptaciones sufre el patrón de marcha lenta teórico al ser reproducido por el exoesqueleto. La presente investigación consiste en un estudio cuantitativo transversal desarrollado en dos etapas: estudio 1 y estudio 2. En el estudio 1 se analizó el patrón de la marcha a velocidad libremente seleccionada (normal) y el patrón de la marcha a velocidad lenta (0.25m/s) en 62 sujetos distribuidos en grupos considerando el sexo y los percentiles 25, 50 y 75 de estatura de la población española. Durante el estudio 2 se analizó el patrón de la marcha lenta reproducido por el dispositivo Hybrid a diferentes porcentajes de peso corporal (30%, 50% y 70%) en diez sujetos seleccionados aleatoriamente de la muestra del estudio 1. En ambos estudios se obtuvieron variables espacio-temporales y cinemáticas mediante un sistema de captura de movimiento con 6 cámaras distribuidas a lo largo de un pasillo de marcha. Se calcularon las medias, las desviaciones estándar y el 95% de intervalo de confianza, y el nivel alfa de significación se estableció en α=0.05 para todas las pruebas estadísticas. Las principales diferencias en el patrón normal de la marcha se encontraron en los parámetros cinemáticos de hombres y mujeres, aunque también se presentaron diferencias entre los grupos en función de la estatura. Las mujeres mostraron mayor flexión de cadera y rodilla, y mayor extensión de tobillo que los hombres durante el ciclo normal, aunque la basculación lateral de la pelvis, mayor en las mujeres, y el desplazamiento lateral del centro de gravedad, mayor en los hombres, fueron los parámetros identificados como principales discriminantes entre sexos. La disminución de la velocidad de la marcha mostró similares adaptaciones y modificaciones en hombres y en mujeres, presentándose un aumento de la fase de apoyo y una disminución de la fase de oscilación, un retraso de los máximos y mínimos de flexoextensión de cadera, rodilla y tobillo, y una disminución del rango articular en las tres articulaciones. Asimismo, la basculación lateral de la pelvis y el movimiento vertical del centro de gravedad disminuyeron, mientras que el movimiento lateral del centro de gravedad y el ancho de paso aumentaron. Durante la evaluación del patrón de la marcha reproducido por el exoesqueleto se observó que las tres articulaciones del miembro inferior disminuían el rango de movimiento por la falta de fuerza de los motores para contrarrestar el peso corporal, incluso con un 70% de descarga de peso. Además, la transferencia de peso se encontró limitada por la falta de movimiento de la pelvis en el plano frontal y se sustituyó por un aumento de la inclinación del tronco y, por tanto, del movimiento lateral del centro de gravedad. Este hecho, junto al aumento del desplazamiento vertical del centro de gravedad, hizo del patrón de la marcha reproducido por el exoesqueleto un movimiento poco eficiente. En conclusión, se establecen patrones de marcha normal diferenciados por sexos, siendo la basculación lateral de la pelvis y el movimiento lateral del centro de gravedad los parámetros discriminantes más característicos entre sexos. Comparando la marcha a velocidad libremente seleccionada y la velocidad lenta, se concluye que ambos sexos utilizan estrategias similares para adaptar el patrón de la marcha a una velocidad lenta y se mantienen las características diferenciadoras entre hombres y mujeres. En relación a la evaluación del dispositivo Hybrid, se deduce que la falta de movimiento lateral de la pelvis condiciona la transferencia de peso y el aumento del rango de movimiento del centro de gravedad y, en consecuencia, tiene como resultado un patrón de la marcha poco eficiente. Este patrón no resultaría indicado para los procesos de rehabilitación o recuperación de la marcha, aunque podría considerarse adecuado para la compensación funcional de la bipedestación y la locomoción. ABSTRACT The human walking is a means of moving body forward using a repetitious and coordinated sequence of pelvis and lower limb motions. It is frequently influenced by biomechanical and anatomical factors or by musculoskeletal pathologies which modify the way of walking. The spinal injury is one of those pathologies which affect the normal pattern of walking, due to the alteration of the mobility, the sensory or the autonomic nervous system. Although the spinal injury affects many other body functions, apart from the motor and sensory ones, the main priority for patients is to recover the ability of walking. Consequently, the main objective of many research groups and private companies is the development of rehabilitation and compensation devices for walking. In this context, the Hybrid Technological Platform for Rehabilitation, Functional Compensation and Training of Gait in Spinal Cord Injury Patients project has developed a device which integrates an exoskeleton and a motorized smart walker. This system, as other similar devices, has the human movement as standard reference. Nevertheless, these devices are not usually evaluated on the way they reproduce the normal human pattern or on the modifications and in the interactions with the patient’s body. The aim of the present study is to examine the normal walking characteristics, to analyze the differences between self-selected and low speed walking patterns, and to evaluate the modifications and adaptations of walking pattern when it is reproduced by the exoskeleton. The present research is a quantitative cross-sectional study carried out in two phases: study 1 and study 2. During the study 1, the self-selected and the low speed (0.25m/s) walking patterns were analyzed in sixty-two people distributed in groups, according to sex and 25th, 50th and 75th percentiles of height for Spanish population. The study 2 analyzed the low speed walking pattern reproduced by the Hybrid system in three conditions: 30%, 50% and 70% of body weight support. To do this, ten subjects were randomly selected and analyzed from the people of study 1. An optoelectronic system with six cameras was used to obtain spatial, temporal and kinematic parameters in both studies. Means, standard deviations and 95% confidence intervals of the study were calculated. The alpha level of significance was set at α=0.05 for all statistical tests. The main differences in normal gait pattern were found in kinematic parameters between men and women. The hip and the knee were more flexed and the ankle plantar flexion was higher in women than in men during normal gait cycle. Although the greater pelvic obliquity of women and the higher lateral movement of center of gravity of men were the most relevant discriminators between male and female gait patterns. Comparing self-selected and low speed walking patterns, both sexes showed similar adaptations and modifications. At low speed walking, men and women increased the stance phase ratio and decreased the swing phase ratio. The maximum and minimum peak flexion of hip, knee and ankle appeared after and the range of motion of them decreased during low speed walking. Furthermore, the pelvic obliquity and the vertical movement of the center of gravity decreased, whereas the lateral movement of center of gravity and step width increased. Evaluating the gait pattern reproduced by the exoskeleton, a decrease of lower limb range of motion was observed. This was probably due to the lack of strength of the engines, which were not able to control the body weight, even with the 70% supported. Moreover, the weight transfer from one limb to the contralateral side was restricted due to the lack of pelvis obliquity. This movement deficiency was replaced by the lateral torso sway and, consequently, the increase of lateral movement of the center of gravity. This fact, as well as the increase of the vertical displacement of the center of gravity, made inefficient the gait pattern reproduced by the exoskeleton. In conclusion, different gait patterns of both sexes have been determined, being pelvis obliquity and lateral movement of center of gravity the most relevant discriminators between male and female gait patterns. Comparing self-selected and low speed walking patterns, it was concluded that both sexes use similar strategies for adapting the gait pattern to a low speed, and therefore, the differentiating characteristics of normal gait are maintained. Regarding the Hybrid system evaluation, it was determined that the gait pattern reproduced by the exoskeleton is inefficient. This was due to the lack of pelvis obliquity and the increase of the center of gravity displacement. Consequently, whereas the walking pattern reproduced by the exoskeleton would not be appropriated for the rehabilitation process, it could be considered suitable for functional compensation of walking and standing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although coronary artery disease (CAD) is appreciated to be accelerated in patients with chronic spinal cord injury (SCI), the underlying mechanism of CAD in SCI remains obscure. We have recently shown that platelets from subjects with SCI develop resistance to the inhibitory effect of prostacyclin (PGI2) on the platelet stimulation of thrombin generation. The loss of the inhibitory effect was due to the loss of high-affinity prostanoid receptors, which may contribute to atherogenesis in SCI. Incubation of normal, non-SCI platelets in SCI plasma (n = 12) also resulted in the loss of high-affinity binding of PGI2 (Kd1 = 9.1 ± 2.0 nM; n1 = 170 ± 32 sites per cell vs. Kd1 = 7.2 ± 1.1 nM; n1 = 23 ± 8 sites per cell), with no significant change in the low-affinity receptors (Kd2 = 1.9 ± 0.1 μM; n2 = 1,832 ± 232 sites per cell vs. Kd2 = 1.6 ± 0.1 μM; n2 = 1,740 ± 161 sites per cell) as determined by Scatchard analysis of the binding of [3H]PGE1. The loss of high-affinity PGI2 binding led to the failure of PGI2 to inhibit the platelet-stimulated thrombin generation. The increase of cellular cyclic AMP level, mediated through the binding of PGI2 to low-affinity receptors in platelets, was unaffected in SCI platelets. PAGE and immunoblot of SCI plasma showed the presence of an IgG band, which specifically blocked the binding of [3H]PGE1 to the high-affinity PGI2 receptors of normal platelets. PAGE of the reduced IgG band, the amino acid sequence of the novel band as a heavy chain of IgG that inhibits the binding of [3H]PGE1 to the high-affinity platelet PGI2 receptor, demonstrates that the specific recognition and inhibition of high-affinity PGI2 binding to platelets was due to an anti-prostacyclin receptor antibody present in SCI plasma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Internet has created new opportunities for librarians to develop information systems that are readily accessible at the point of care. This paper describes the multiyear process used to justify, fund, design, develop, promote, and evaluate a rehabilitation prototype of a point-of-care, team-based information system (PoinTIS) and train health care providers to use this prototype for their spinal cord injury and traumatic brain injury patient care and education activities. PoinTIS is a successful model for librarians in the twenty-first century to serve as publishers of information created or used by their parent organizations and to respond to the opportunities for information dissemination provided by recent technological advances.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A bexiga neurogênica é uma disfunção vesical decorrente principalmente da lesão medular. O cateterismo vesical intermitente é o tratamento mais indicado na atualidade, deve ser realizado de 4 a 6 vezes ao dia, durante toda a vida, visando a proteção do trato urinário superior e a aquisição da continência urinária. Na reabilitação desses indivíduos, a autocateterização vesical é um desafio enfrentado na busca pela autonomia, privacidade, inserção social e participação. Os vídeos educativos são utilizados para o aprendizado do autocateterismo em vários países, por serem de fácil utilização e acesso via internet. Apesar disso, não existem vídeos realizados para o contexto brasileiro, levando em consideração os cateteres urinários e a técnica utilizada no Brasil. Este estudo teve como objetivo desenvolver e validar um vídeo educativo para a realização do autocateterismo vesical intermitente limpo. Trata-se de um estudo quantitativo, desenvolvido em duas fases: 1ª fase com a avaliação de vídeos educativos públicos direcionados para a aprendizagem do autocateterismo vesical intermitente com a técnica limpa; e 2ª Fase, com o desenvolvimento e validação de um vídeo educativo voltado para aprendizagem do autocateterismo. O levantamento dos vídeos utilizou um site de compartilhamento de vídeos utilizando o descritor \"autocateterismo\". Os vídeos foram avaliados por três juízes da área de saúde. O processo de desenvolvimento e validação do roteiro do vídeo educativo utilizou questionários previamente ratificados. Participaram dessas etapas, respectivamente, 18 e 17 juízes experts em reabilitação e/ou no ensino em saúde. O levantamento mostrou que apenas 3,5% (172) do total de vídeos disponíveis no site pesquisado eram voltados para o aprendizado do autocateterismo no contexto brasileiro. Seis vídeos eram específicos para o autocateterismo, dos quais quatro tinham informações desatualizadas ou incorretas, apenas dois atingiram a pontuação aceitável. Na validação do roteiro observou-se um predomínio de participantes do sexo feminino (94,44%), com idade de 30 a 60 anos, dos quais 72,22% possuíam mestrado e 50% atuavam há mais de cinco anos na área de reabilitação. O roteiro foi considerado validado com 96,29% das respostas dos juízes \"concordo\" ou \"concordo totalmente\" nas questões referentes ao quesito objetivo, 91,09% para quesito conteúdo, 98,12% em relação ao quesito relevância, 75% quanto ao quesito ambiente, 71,11% no quesito linguagem verbal e 92,70% referente à inclusão de tópicos. A produção do vídeo contou com uso de tecnologia 3D e apoio de uma equipe técnica especializada. No que se refere à validação do conteúdo do vídeo educativo, o conteúdo do vídeo foi considerado validado com 100% dos juízes que responderam \"concordo\" ou \"concordo totalmente\" nas questões referentes à funcionalidade, 86,27% referentes à usabilidade, 97,06% no quesito eficiência, 100% para técnica audiovisual, 94,11% quanto ao ambiente e 97,05% procedimento. O vídeo educativo foi avaliado positivamente tanto pela qualidade das informações quanto pela didática do ensino, mostrando a relevância da validação de materiais educativos. A expectativa é disseminar o vídeo educativo em diferentes centros de reabilitação e Universidades, visando propagar e tornar o conhecimento sobre a temática mais acessível à sociedade e aos profissionais de saúde, em especial os de reabilitação. Além de incentivar e embasar metodologicamente o desenvolvimento de outros vídeos educativos na área da saúde