909 resultados para comparison methods


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A special class of preferences, given by a directed acyclic graph, is considered. They are represented by incomplete pairwise comparison matrices as only partial information is available: for some pairs no comparison is given in the graph. A weighting method satisfies the property linear order preservation if it always results in a ranking such that an alternative directly preferred to another does not have a lower rank. We study whether two procedures, the Eigenvector Method and the Logarithmic Least Squares Method meet this axiom. Both weighting methods break linear order preservation, moreover, the ranking according to the Eigenvector Method depends on the incomplete pairwise comparison representation chosen.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Nowadays we meet many different evaluation methods regarding the ecological performance of green surfaces and parks. All these methods are extremely valuable in determining how well a green surface performs from ecological aspect and to what extent the environment were damaged if these sites would be built or would be developed any other way causing reduction of green surfaces. The goal of the article is to clarify the differences between two evaluation methods (GSI – Green Space Intensity, BARC – Biological Activity Rate Calculation) suitable for urban green infrastructure analysis and to see if any significant difference can be observed evaluating the same site by these methods. Our research sites are in Budapest and their sizes vary between 2,5-8 acres. The most important aspects of site analysis are the following: size and boundaries of the park, existence or lack of water features, the characteristics of their surfaces and the complexity of vegetation. We summarize the data of the site analysis in tables, make a summarizing diagram for visual representation and draw conclusions from the results. As a final step, we evaluate how these two evaluation systems relate to urban open space developments.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this research was to compare the delivery methods as practiced by higher education faculty teaching distance courses with recommended or emerging standard instructional delivery methods for distance education. Previous research shows that traditional-type instructional strategies have been used in distance education and that there has been no training to distance teach. Secondary data, however, appear to suggest emerging practices which could be pooled toward the development of standards. This is a qualitative study based on the constant comparative analysis approach of grounded theory.^ Participants (N = 5) of this study were full-time faculty teaching distance education courses. The observation method used was unobtrusive content analysis of videotaped instruction. Triangulation of data was accomplished through one-on-one in-depth interviews and from literature review. Due to the addition of non-media content being analyzed, a special time-sampling technique was designed by the researcher--influenced by content analyst theories of media-related data--to sample portions of the videotape instruction that were observed and counted. A standardized interview guide was used to collect data from in-depth interviews. Coding was done based on categories drawn from review of literature, and from Cranton and Weston's (1989) typology of instructional strategies. The data were observed, counted, tabulated, analyzed, and interpreted solely by the researcher. It should be noted however, that systematic and rigorous data collection and analysis led to credible data.^ The findings of this study supported the proposition that there are no standard instructional practices for distance teaching. Further, the findings revealed that of the emerging practices suggested by proponents and by faculty who teach distance education courses, few were practiced even minimally. A noted example was the use of lecture and questioning. Questioning, as a teaching tool was used a great deal, with students at the originating site but not with distance students. Lectures were given, but were mostly conducted in traditional fashion--long in duration and with no interactive component.^ It can be concluded from the findings that while there are no standard practices for instructional delivery for distance education, there appears to be sufficient information from secondary and empirical data to initiate some standard instructional practices. Therefore, grounded in this research data is the theory that the way to arrive at some instructional delivery standards for televised distance education is a pooling of the tacitly agreed-upon emerging practices by proponents and practicing instructors. Implicit in this theory is a need for experimental research so that these emerging practices can be tested, tried, and proven, ultimately resulting in formal standards for instructional delivery in television education. ^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aims The pubococcygeal line (PCL) is an important reference line for determining measures of pelvic organ support on sagittal-plane magnetic resonance imaging (MRI); however, there is no consensus on where to place the posterior point of the PCL. As coccyx movement produced during pelvic floor muscle (PFM) contractions may affect other measures, optimal placement of the posterior point is important. This study compared two methods for measuring the PCL, with different posterior points, on T2-weighted sagittal MRI to determine the effect of coccygeal movement on measures of pelvic organ support in older women. Methods MRI of the pelvis was performed in the midsagittal plane, at rest and during PFM contractions, on 47 community-dwelling women 60 and over. The first PCL was measured to the tip of the coccyx (PCLtip) and the second to the sacrococcygeal joint (PCLjnt). Four measures of pelvic organ support were made using each PCL as the reference line: urethrovesical junction height, uterovaginal junction height, M-line and levator plate angle. Results During the PFM contraction the PCLtip shortened and lifted (P < 0.001); the PCLjnt did not change (P > 0.05). The changes in the four measures of pelvic organ support were smaller when measured relative to the PCLtip as compared to those to the PCLjnt (P < 0.001). Conclusions Coccyx movement affected the length and position of the PCLtip, which resulted in underestimates of the pelvic-organ lift produced by the PFM contraction. Therefore, we recommend that the PCL be measured to the sacrococcygeal joint and not to the tip of the coccyx

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We are writing to comment on the work of Tamburini et al. (2003, doi:10.1029/2000PA000616). During the course of subsequent discussions between the authors and ourselves, it has become clear that the published sedimentary nitrogen isotopic values for Ocean Drilling Program (ODP) Site 724 are in error. Our reanalysis of sediment samples from the same intervals has revealed a significant offset from the original d15N data, requiring a revised assessment of their initial interpretation. The purposes of this comment are to (1) address the origin of these errors; (2) outline a protocol for future validation of nitrogen isotopic analyses; and (3) provide revised interpretations of the sedimentary d15N data in terms of the regional relative contributions of denitrification and nitrogen fixation and mean state of the southwest monsoon. (2) Nitrogen isotopic values measured on late Quaternary sediments at Arabian Sea ODP Site 724 by Tamburini et al. (2003, doi:10.1029/2000PA000616) are inexplicably different from a number of published records of d15N from very nearby on the Oman margin (Altabet et al., 1995, doi:10.1038/373506a0; 1999, doi:10.1029/1999PA900035; 2002, doi:10.1038/415159a; Higginson et al., 2004, doi:10.1016/j.gca.2004.03.015) and elsewhere in the Arabian Sea (Reichart et al., 1998, doi:10.1029/98PA02203). These data were generated using similar instrumentation (elemental analyzer coupled with an isotope ratio mass spectrometer) and analytical methodology to those already published. Concerned by this clear discrepancy, we analyzed aliquots of sediment from the same depth intervals for nitrogen abundance and bulk sedimentary nitrogen isotopes. We have been unable to duplicate the values published by Tamburini et al. (2003, doi:10.1029/2000PA000616 ), even after analysis of multiple replicates and due consideration of natural sediment heterogeneities and postrecovery sample storage.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Lower jaws (containing the teeth), eyes, and skin samples were collected from harp seals (Pagophilus groenlandicus) in the southeastern Barents Sea for the purpose of comparing age estimates obtained by 3 different methods, the traditional technique of counting growth layer groups (GLGs) in teeth and 2 novel approaches, aspartic acid racemization (AAR) in eye lens nuclei and telomere sequence analyses as a proxy for telomere length. A significant correlation between age estimates obtained using GLGs and AAR was found, whereas no correlation was found between GLGs and telomere length. An AAR rate (k Asp) of 0.00130/year ± 0.00005 SE and a D-enantiomer to L-enantiomer ratio at birth (D/L 0 value) of 0.01933 ± 0.00048 SE were estimated by regression of D/L ratios against GLG ages from 25 animals (12 selected teeth that had high readability and 13 known-aged animals). AAR could prove to be useful, particularly for ageing older animals in species such as harp seals where difficulties in counting GLGs tend to increase with age. Age estimation by telomere length did not show any correlation with GLG ages and is not recommended for harp seals.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Harmful algal blooms (HABs) are a natural global phenomena emerging in severity and extent. Incidents have many economic, ecological and human health impacts. Monitoring and providing early warning of toxic HABs are critical for protecting public health. Current monitoring programmes include measuring the number of toxic phytoplankton cells in the water and biotoxin levels in shellfish tissue. As these efforts are demanding and labour intensive, methods which improve the efficiency are essential. This study compares the utilisation of a multitoxin surface plasmon resonance (multitoxin SPR) biosensor with enzyme-linked immunosorbent assay (ELISA) and analytical methods such as high performance liquid chromatography with fluorescence detection (HPLC-FLD) and liquid chromatography–tandem mass spectrometry (LC–MS/MS) for toxic HAB monitoring efforts in Europe. Seawater samples (n = 256) from European waters, collected 2009–2011, were analysed for biotoxins: saxitoxin and analogues, okadaic acid and dinophysistoxins 1/2 (DTX1/DTX2) and domoic acid responsible for paralytic shellfish poisoning (PSP), diarrheic shellfish poisoning (DSP) and amnesic shellfish poisoning (ASP), respectively. Biotoxins were detected mainly in samples from Spain and Ireland. France and Norway appeared to have the lowest number of toxic samples. Both the multitoxin SPR biosensor and the RNA microarray were more sensitive at detecting toxic HABs than standard light microscopy phytoplankton monitoring. Correlations between each of the detection methods were performed with the overall agreement, based on statistical 2 × 2 comparison tables, between each testing platform ranging between 32% and 74% for all three toxin families illustrating that one individual testing method may not be an ideal solution. An efficient early warning monitoring system for the detection of toxic HABs could therefore be achieved by combining both the multitoxin SPR biosensor and RNA microarray.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Harmful algal blooms (HABs) are a natural global phenomena emerging in severity and extent. Incidents have many economic, ecological and human health impacts. Monitoring and providing early warning of toxic HABs are critical for protecting public health. Current monitoring programmes include measuring the number of toxic phytoplankton cells in the water and biotoxin levels in shellfish tissue. As these efforts are demanding and labour intensive, methods which improve the efficiency are essential. This study compares the utilisation of a multitoxin surface plasmon resonance (multitoxin SPR) biosensor with enzyme-linked immunosorbent assay (ELISA) and analytical methods such as high performance liquid chromatography with fluorescence detection (HPLC-FLD) and liquid chromatography–tandem mass spectrometry (LC–MS/MS) for toxic HAB monitoring efforts in Europe. Seawater samples (n = 256) from European waters, collected 2009–2011, were analysed for biotoxins: saxitoxin and analogues, okadaic acid and dinophysistoxins 1/2 (DTX1/DTX2) and domoic acid responsible for paralytic shellfish poisoning (PSP), diarrheic shellfish poisoning (DSP) and amnesic shellfish poisoning (ASP), respectively. Biotoxins were detected mainly in samples from Spain and Ireland. France and Norway appeared to have the lowest number of toxic samples. Both the multitoxin SPR biosensor and the RNA microarray were more sensitive at detecting toxic HABs than standard light microscopy phytoplankton monitoring. Correlations between each of the detection methods were performed with the overall agreement, based on statistical 2 × 2 comparison tables, between each testing platform ranging between 32% and 74% for all three toxin families illustrating that one individual testing method may not be an ideal solution. An efficient early warning monitoring system for the detection of toxic HABs could therefore be achieved by combining both the multitoxin SPR biosensor and RNA microarray.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: KRAS mutation testing is required to select patients with metastatic colorectal cancer (CRC) to receive anti-epidermal growth factor receptor antibodies, but the optimal KRAS mutation test method is uncertain. METHODS: We conducted a two-site comparison of two commercial KRAS mutation kits - the cobas KRAS Mutation Test and the Qiagen therascreen KRAS Kit - and Sanger sequencing. A panel of 120 CRC specimens was tested with all three methods. The agreement between the cobas test and each of the other methods was assessed. Specimens with discordant results were subjected to quantitative massively parallel pyrosequencing (MPP). DNA blends were tested to determine detection rates at 5% mutant alleles. RESULTS: Reproducibility of the cobas test between sites was 98%. Six mutations were detected by cobas that were not detected by Sanger, and five were confirmed by MPP. The cobas test detected eight mutations which were not detected by the therascreen test, and seven were confirmed by MPP. Detection rates with 5% mutant DNA blends were 100% for the cobas and therascreen tests and 19% for Sanger. CONCLUSION: The cobas test was reproducible between sites, and detected several mutations that were not detected by the therascreen test or Sanger. Sanger sequencing had poor sensitivity for low levels of mutation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Sub-optimal recovery of bacterial DNA from whole blood samples can limit the sensitivity of molecular assays to detect pathogenic bacteria. We compared 3 different pre-lysis protocols (none, mechanical pre-lysis and achromopeptidasepre-lysis) and 5 commercially available DNA extraction platforms for direct detection of Group B Streptococcus (GBS) in spiked whole blood samples, without enrichment culture. DNA was extracted using the QIAamp Blood Mini kit (Qiagen), UCP Pathogen Mini kit (Qiagen), QuickGene DNA Whole Blood kit S (Fuji), Speed Xtract Nucleic Acid Kit 200 (Qiagen) and MagNA Pure Compact Nucleic Acid Isolation Kit I (Roche Diagnostics Corp). Mechanical pre-lysis increased yields of bacterial genomic DNA by 51.3 fold (95% confidence interval; 31.6–85.1, p < 0.001) and pre-lysis with achromopeptidase by 6.1 fold (95% CI; 4.2–8.9, p < 0.001), compared with no pre-lysis. Differences in yield dueto pre-lysis were 2–3 fold larger than differences in yield between extraction methods. Including a pre-lysis step can improve the limits of detection of GBS using PCR or other molecular methods without need for culture.