970 resultados para catheter


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To study electrophysiological characteristics that enable the identification and ablation of sites of chagasic tachycardia. METHODS: Thirty-one patients with chronic Chagas' heart disease and sustained ventricular tachycardia (SVT) underwent electrophysiological study to map and ablate that arrhythmia. Fifteen patients had hemodinamically stable SVT reproducible by programmed ventricular stimulation, 9 men and 6 women with ages ranging from 37 to 67 years and ejection fraction varying from 0.17 to 0.64. Endocardial mapping was performed during SVT in all patients. Radiofrequency (RF) current was applied to sites of presystolic activity of at least 30 ms. Entrainment was used to identify reentrant circuits. In both successful and unsuccessful sites of RF current application, electrogram and entrainment were analyzed. RESULTS: Entrainment was obtained during all mapped SVT. In 70.5% of the sites we observed concealed entrainment and ventricular tachycardia termination in the first 15 seconds of RF current application. In the unsuccessful sites, significantly earlier electrical activity was seen than in the successful ones. Concealed entrainment was significantly associated with ventricular tachycardia termination. Bystander areas were not observed. CONCLUSION: The reentrant mechanism was responsible for the genesis of all tachycardias. In 70.5% of the studied sites, the endocardial participation of the slow conducting zone of reentrant circuits was shown. Concealed entrainment was the main electrophysiological parameter associated with successful RF current application. There was no electrophysiological evidence of bystander regions in the mapped circuits of SVT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVE: To assess the hemodynamic profile of cardiac surgery patients with circulatory instability in the early postoperative period (POP). METHODS: Over a two-year period, 306 patients underwent cardiac surgery. Thirty had hemodynamic instability in the early POP and were monitored with the Swan-Ganz catheter. The following parameters were evaluated: cardiac index (CI), systemic and pulmonary vascular resistance, pulmonary shunt, central venous pressure (CVP), pulmonary capillary wedge pressure (PCWP), oxygen delivery and consumption, use of vasoactive drugs and of circulatory support. RESULTS: Twenty patients had low cardiac index (CI), and 10 had normal or high CI. Systemic vascular resistance was decreased in 11 patients. There was no correlation between oxygen delivery (DO2) and consumption (VO2), p=0.42, and no correlation between CVP and PCWP, p=0.065. Pulmonary vascular resistance was decreased in 15 patients and the pulmonary shunt was increased in 19. Two patients with CI < 2L/min/m² received circulatory support. CONCLUSION: Patients in the POP of cardiac surgery frequently have a mixed shock due to the systemic inflammatory response syndrome (SIRS). Therefore, invasive hemodynamic monitoring is useful in handling blood volume, choice of vasoactive drugs, and indication for circulatory support.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the results of laser-assisted extraction of permanent pacemaker and defibrillator leads. METHODS: We operated upon 36 patients, whose mean age was 54.2 years, and extracted 56 leads. The reasons for extracting the leads were as follows: infection in 19 patients, elective replacement in 13, and other causes in 4 patients. The mean time of catheter placement was 7.5±5.5 years. Forty-seven leads were from pacemakers, and 9 were from defibrillators. Thirty-eight leads were in use, 14 had been abandoned in the pacemaker pocket, and 4 had been abandoned inside the venous system. RESULTS: We successfully extracted 54 catheters, obtaining a 96.4% rate of success and an 82.1% rate for complete extraction. The 2 unsuccessful cases were due to the presence of calcium in the trajectory of the lead. The mean duration of laser light application was 123.0±104.5 s, using 5,215.2±4,924.0 pulses, in a total of 24.4±24.2 cycles of application. Thirty-four leads were extracted from the myocardium with countertraction after complete progression of the laser sheath, 12 leads came loose during the progression of the laser sheath, and the remaining 10 were extracted with other maneuvers. One patient experienced cardiac tamponade after extraction of the defibrillator lead, requiring open emergency surgery. CONCLUSION: The use of the excimer laser allowed extraction of the leads with a 96% rate of success; it was not effective in 2 patients who had calcification on the lead. One patient (2.8%) had a complication that required cardiac surgery on an emergency basis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To demonstrate the feasibility and safety of simultaneous catheterization and mapping of the 4 pulmonary veins for ablation of atrial fibrillation. METHODS: Ten patients, 8 with paroxysmal atrial fibrillation and 2 with persistent atrial fibrillation, refractory to at least 2 antiarrhythmic drugs and without structural cardiopathy, were consecutively studied. Through the transseptal insertion of 2 long sheaths, 4 pulmonary veins were simultaneously catheterized with octapolar microcatheters. After identification of arrhythmogenic foci radiofrequency was applied under angiographic or ultrasonographic control. RESULTS: During 17 procedures, 40 pulmonary veins were mapped, 16 of which had local ectopic activity, related or not with the triggering of atrial fibrillation paroxysms. At the end of each procedure, suppression of arrhythmias was obtained in 8 patients, and elimination of pulmonary vein potentials was accomplished in 4. During the clinical follow-up of 9.6±3 months, 7 patients remained in sinus rhythm, 5 of whom were using antiarrhythmic drugs that had previously been ineffective. None of the patients had pulmonary hypertension or evidence of stenosis in the pulmonary veins. CONCLUSION: Selective and simultaneous catheterization of the 4 pulmonary veins with microcatheters for simultaneous recording of their electrical activity is a feasible and safe procedure that may help ablation of atrial fibrillation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To analyze our experience with percutaneous aortic balloon valvuloplasty in newborn infants with aortic stenosis, emphasizing the extraordinary importance of myocardial perfusion.METHODS: Over a 10-year-period, 21 neonates underwent percutaneous aortic balloon valvuloplasty. Age ranged from 2 to 27 days, weight ranged from 2.2 to 4.1 kg and 19 were males. All patients presented with congestive heart failure that could not be treated clinically. The onset of symptoms in the first week of life occurred in 9 patients considered as having critical aortic stenosis. Severe aortic stenosis occurred in 12 patients with the onset of symptoms in the second week of life.RESULTS: Mortality reached 100% in the patients with critical aortic stenosis. The procedure was considered effective in the 12 patients with severe aortic stenosis. Vascular complications included the loss of pulse in 12 patients and rupture of the femoral artery in 2 patients. Cardiac complications included acute aortic regurgitation in 2 patients and myocardial perforation in one. In an 8.2±1.3-year follow-up, 5 of the 12 patients died (2 patients due to septicemia and 3 patients due to congestive heart failure). Five of the other 7 patients underwent a new procedure and 2 required surgery.CONCLUSION: Percutaneous aortic valvuloplasty in neonates is not an effective procedure in the 1st week of life, because at this age the common presentation is cardiogenic shock. It is possible that, in those patients with critical aortic stenosis, dilation of the aortic valve during fetal life may change the prognosis of its clinical outcome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To analyze hemodynamic and metabolic effects of saline solution infusion in the maintenance of blood volume in ischemia-reperfusion syndrome during temporary abdominal aortic occlusion in dogs. METHODS: We studied 20 dogs divided into 2 groups: the ischemia-reperfusion group (IRG, n=10) and the ischemia-reperfusion group with saline solution infusion aiming at maintaining mean pulmonary arterial wedge pressure between 10 and 20 mmHg (IRG-SS, n=10). All animals were anesthetized with sodium thiopental and maintained on spontaneous ventilation. Occlusion of the supraceliac aorta was obtained with inflation of a Fogarty catheter inserted through the femoral artery. After 60 minutes of ischemia, the balloon was deflated, and the animals were observed for another 60 minutes of reperfusion. RESULTS: IRG-SS dogs did not have hemodynamic instability after aortic unclamping, and the mean systemic blood pressure and heart rate were maintained. However, acidosis worsened, which was documented by a greater reduction of arterial pH that occurred especially due to the absence of a respiratory response to metabolic acidosis that was greater with the adoption of this procedure. CONCLUSION: Saline solution infusion to maintain blood volume avoided hemodynamic instability after aortic unclamping. This procedure, however, caused worsening in metabolic acidosis in this experimental model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the efficacy of percutaneous transluminal septal alcoholization in the treatment of refractory obstructive hypertrophic cardiomyopathy (HOC). METHODS: The patients were referred for alcoholization after Doppler echocardiography. Before and after alcoholization, the intraventricular pressure gradient was recorded. Alcoholization was performed with a 3mL injection of absolute alcohol through a coronary angioplasty balloon catheter. The procedure was concluded after a significant reduction or abolition of the pressure gradient. RESULTS: Of 22 patients, 18 (81.8%) successfully concluded the procedure with a reduction in intraventricular pressure gradient at baseline (from 67.6±24.2 mmHg to 3.8± 1.9 mmHg, p<0.005) and after extrasystole (from 110.4± 24.2 mmHg to 9.6±2.6 mm Hg, p<0.005). A significant reduction in mean interventricular septal thickness (from 2± 0.3 mm to 1.7±0.2 mm, p<0.005) and in peak pressure gradient (from 90.7±23.5 mmHg to 6.1±1.4 mmHg, p<0.005) was observed on Doppler echocardiography after 6 months, when all patients were in functional class I. The most frequent acute complication, present in 11% of the patients, was the need for definitive pacing implantation. Relapse of the symptoms and reappearance of the pressure gradient occurred in 16.6% of the patients. One patient (5.5%) died probably due to a diffuse coronary spasm prior to the procedure, and another died suddenly on late follow-up. CONCLUSION: Percutaneous transluminal septal alcoholization is effective and safe in the treatment of HOC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the impact of the use, prior to the procedure, of injectable diltiazem to prevent complications. METHODS: Between September 2000 and July 2001, 50 patients underwent transradial coronary angiography and were randomized to receive placebo (GI) or diltiazem (GII) through a catheter inserted into the radial artery. All patients received isosorbide mononitrate. Ultrasound analyses of the radial artery were performed before examination, 30 minutes afterwards, and 7 days afterwards to evaluate the flow, the diameter, and the artery output. RESULTS: The radial artery diameter of GI was 2.4± 0.5 mm before the procedure and 2.3±0.5 mm after 30 minutes (NS), whereas in GII the diameter was 2.2±0.3 mm before the examination and 2.5±0.4 mm 30 minutes after it (P<0.001). Radial artery output in group 1 was 7.3±5.l2 mL/min before the examination and 6.1±3.5 mL/min 30 minutes after the examination (NS), and GII had an increase of 5.9±2.5 mL/min before examination to 9.05± 7.78 mL/min after the examination (P=0.04). Complications (spasm, occlusion, and partial obstruction) occurred in 4 patients (17.4%) in GI and did not occur in GII (P=0.04). CONCLUSION: The study suggests a decrease in vascular complications through the transradial access for coronary angiography with the use of diltiazem as an antispasmodic drug, resulting in the significant increase in the diameter of the radial artery and radial artery output.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abdominal Aortic Aneurysms (AAA) haemorhaging is a life-threatening disease. An aneurysm is a permanent swelling of an artery due to a weakness in its wall. Current surgical repair involves opening the chest or abdomen, gaining temporary vascular control of the aorta and suturing a prosthetic graft to the healthy aorta within the aneurysm itself The outcome of this surgical approach is not perfect, and the quality of life after this repair is impaired by postoperative pain, sexual dysfunction, and a lengthy hospital stay resulting in high health costs. All these negative effects are related to the large incision and extensive tissue dissection. Endovascular grafting is an alternative to the standard surgical method. This treatment is a less invasive method of treating aortic aneurysms. It involves a surgical exposure of the common femoral arteries where the stent graft can be inserted through by an over-the-wire technique. All manipulations are controlled from a remote place by the use of a catheter and this technique avoids the need to directly expose the diseased artery through a large incision or an extensive dissection. The proposed design method outlined in this project is to develop the endovascular approach. The main aim is to design an unitary bifurcated stent graft (1 e- bifurcated graft as a single component) to treat these Abdominal Aortic Aneurysms. This includes the delivery system and deployment mechanism necessary to first accurately position the stent graft across the aneurysm sac and also across the iliac bifurcation, and secondly fix the stent graft in position by using expandable metal stents. Thus, excluding the aneurysm from the circulation and therefore preventing rupture. Miniaturisation is a critical aspect of this design, as the smaller the crimped stent graft the easier to guide through the vascular system to the desired location. Biocompatibility is an important aspect. The preferred materials for this prosthesis are to use Shape Memory Alloys for the stent and a multifilament fabric for the graft. A taper design is applied for the geometry as this gives a favourable flow characteristic and reduced wave reflections. Adequate testing of the stent graft to prove its durability and the ease of the method of deployment is a prerequisite. A bench test facility has being designed and build to replicate the cardiovascular system and the disease in question aortic aneurysms at the iliac bifurcation. The testing here shows the feasibility of the proposed delivery system and the durability of the stent graft across the aneurysm sac. Finally, these endovascular treatments offer the economic advantage of short hospital stays or even treatment as an outpatient, as well as elimination of the need for postoperative intensive care The risk of developing an aneurysm increases with age, that is one of the mam reasons to look for less invasive ways of treating aneurysms. Consequently, there is enormous pressure to develop and use these devices rapidly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Systemic arterial hypertension (SAH) is considered to be the greatest risk factor for the development of neuro-cardiovascular pathologies, thus constituting a severe Public Health issue in the world. The Low-Level Laser Therapy (LLLT), or laser therapy, activates components of the cellular structure, therefore converting luminous energy into photochemical energy and leading to biophysical and biochemical reactions in the mitochondrial respiratory chain. The LLLT promotes cellular and tissue photobiomodulation by means of changes in metabolism, leading to molecular, cellular and systemic changes. The objective of this study was to analyze the action of low-level laser in the hemodynamic modulation of spontaneously hypertensive rats, in the long term. Animals (n = 16) were randomly divided into the Laser Group (n = 8), which received three weekly LLLT irradiations for seven weeks, and into the Sham Group (n = 8), which received three weekly simulations of laser for seven weeks, accounting for 21 applications in each group. After seven weeks, animals were cannulated by the implantation of a catheter in the left carotid artery. On the following day, the systemic arterial pressure was recorded. The Laser Group showed reduced levels of mean blood pressure, with statistically significant reduction (169 ± 4 mmHg* vs. 182 ± 4 mmHg from the Sham Group) and reduced levels of diastolic pressure (143 ± 4 mmHg* vs. 157 ± 3 mmHg from the Sham Group), revealing a 13 and 14 mmHg decrease, respectively. Besides, there was a concomitant important decline in heart rate (312 ± 14 bpm vs. 361 ± 13 bpm from the Sham Group). Therefore, laser therapy was able to produce hemodynamic changes, thus reducing pressure levels in spontaneously hypertensive rats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background:Left ventricular (LV) diastolic dysfunction is associated with new-onset atrial fibrillation (AF), and the estimation of elevated LV filling pressures by E/e' ratio is related to worse outcomes in patients with AF. However, it is unknown if restoring sinus rhythm reverses this process.Objective:To evaluate the impact of AF ablation on estimated LV filling pressure.Methods:A total of 141 patients underwent radiofrequency (RF) ablation to treat drug-refractory AF. Transthoracic echocardiography was performed 30 days before and 12 months after ablation. LV functional parameters, left atrial volume index (LAVind), and transmitral pulsed and mitral annulus tissue Doppler (e' and E/e') were assessed. Paroxysmal AF was present in 18 patients, persistent AF was present in 102 patients, and long-standing persistent AF in 21 patients. Follow-up included electrocardiographic examination and 24-h Holter monitoring at 3, 6, and 12 months after ablation.Results:One hundred seventeen patients (82.9%) were free of AF during the follow-up (average, 18 ± 5 months). LAVind reduced in the successful group (30.2 mL/m2 ± 10.6 mL/m2 to 22.6 mL/m2 ± 1.1 mL/m2, p < 0.001) compared to the non-successful group (37.7 mL/m2 ± 14.3 mL/m2 to 37.5 mL/m2 ± 14.5 mL/m2, p = ns). Improvement of LV filling pressure assessed by a reduction in the E/e' ratio was observed only after successful ablation (11.5 ± 4.5 vs. 7.1 ± 3.7, p < 0.001) but not in patients with recurrent AF (12.7 ± 4.4 vs. 12 ± 3.3, p = ns). The success rate was lower in the long-standing persistent AF patient group (57% vs. 87%, p = 0.001).Conclusion:Successful AF ablation is associated with LA reverse remodeling and an improvement in LV filling pressure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background:Radiofrequency ablation is the standard non-pharmacological treatment for arrhythmias in pediatric patients. However, arrhythmias and their associated causes have particular features in this population.Objective:To analyze the epidemiological characteristics and findings of electrophysiological diagnostic studies and radiofrequency ablations in pediatric patients referred to the Electrophysiology Unit at Instituto de Cardiologia do Rio Grande do Sul, in order to characterize the particularities of this population.Methods:Cross-sectional study with 330 electrophysiological procedures performed in patients aged less than 20 years between June 1997 and August 2013.Results:In total, 330 procedures (9.6% of the overall procedures) were performed in patients aged less than 20 years (14.33 ± 3.25 years, age range 3 months to 19 years), 201 of which were males (60.9%). A total of 108 (32.7%) electrophysiological diagnostic studies were performed and of these, 48.1% showed abnormal findings. Overall, 219 radiofrequency ablations were performed (66.3%) with a success rate of 84.8%. The presence of an accessory pathway was the most prevalent finding, occurring in 158 cases (72.1%), followed by atrioventricular nodal reentrant tachycardia (16.8%), typical atrial flutter (3.1%) and extrasystoles originating from the right ventricular outflow tract (2.7%). Three patients developed complications during ablation (1.4%). Among congenital heart diseases, which occurred in 51 (15.4%) patients, atrial sept defect was the most frequent (27.4%), followed by ventricular sept defect (25.4%) and Ebstein's anomaly (17.6%).Conclusion:Electrophysiological study and radiofrequency ablation are effective tools for diagnosis and treatment of arrhythmias in the pediatric population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background:Heart failure and atrial fibrillation (AF) often coexist in a deleterious cycle.Objective:To evaluate the clinical and echocardiographic outcomes of patients with ventricular systolic dysfunction and AF treated with radiofrequency (RF) ablation.Methods:Patients with ventricular systolic dysfunction [ejection fraction (EF) <50%] and AF refractory to drug therapy underwent stepwise RF ablation in the same session with pulmonary vein isolation, ablation of AF nests and of residual atrial tachycardia, named "background tachycardia". Clinical (NYHA functional class) and echocardiographic (EF, left atrial diameter) data were compared (McNemar test and t test) before and after ablation.Results:31 patients (6 women, 25 men), aged 37 to 77 years (mean, 59.8±10.6), underwent RF ablation. The etiology was mainly idiopathic (19 p, 61%). During a mean follow-up of 20.3±17 months, 24 patients (77%) were in sinus rhythm, 11 (35%) being on amiodarone. Eight patients (26%) underwent more than one procedure (6 underwent 2 procedures, and 2 underwent 3 procedures). Significant NYHA functional class improvement was observed (pre-ablation: 2.23±0.56; postablation: 1.13±0.35; p<0.0001). The echocardiographic outcome also showed significant ventricular function improvement (EF pre: 44.68%±6.02%, post: 59%±13.2%, p=0.0005) and a significant left atrial diameter reduction (pre: 46.61±7.3 mm; post: 43.59±6.6 mm; p=0.026). No major complications occurred.Conclusion:Our findings suggest that AF ablation in patients with ventricular systolic dysfunction is a safe and highly effective procedure. Arrhythmia control has a great impact on ventricular function recovery and functional class improvement.