726 resultados para body image - women
Resumo:
BACKGROUND AND AIMS: little is known regarding the reproducibility of body fat measuring devices; hence, we assessed the between and within-device reproducibility, and the within-day variability of body fat measurements. METHODS: body fat percentage was measured twice on seventeen female students aged between 18 and 20 with a body mass index of 21.9 ± 2.5 kg/m2 (mean ± SD) using seven bipolar bioelectrical impedance devices. Each participant was also measured each hour between 7:00 and 22:00. RESULTS: the correlation between first and second measurements was very high (Spearman r between 0.985 and 1.000, p<0.001), as well as between devices (Spearman r between 0.916 and 0.991, p<0.001). Repeated measurements analysis showed no differences were between devices (p=0.59) or readings (first vs. second: p=0.74). Conversely, significant differences were found between assessment periods throughout the day, measurements made in the morning being lower than those made in the afternoon (F test for repeated values= 6.58, p<0.001). CONCLUSIONS: the between and within-device reproducibility for measuring body fat is high, enabling the use of multiple devices in a single study. Conversely, small but significant changes in body fat measurements occur during the day, urging body fat measurements to be performed at fixed times.
Resumo:
Twenty-four-hour energy expenditure (EE), daily and sleeping EE, and the energy cost of a standardized treadmill exercise were assessed in a respiration chamber in 41 young pregnant Gambian women at 12 (n = 11), 24 (n = 15), and 36 (n = 15) wk of gestation and compared with 13 nonpregnant nonlactating (NPNL) control women. The rate of 24-h EE was significantly higher (P less than 0.001) at 36 wk gestation (8443 +/- 243 kJ/d) than in the NPNL group (6971 +/- 172 kJ/d) or at 12 and 24 wk (7088 +/- 222 and 7188 +/- 192 kJ/d, respectively). Per unit body weight, no more differences in 24-h EE, daily and sleeping EE, or energy cost of walking were observed between pregnant and NPNL women. There was no statistical difference in the 24-h respiratory quotient among the groups. We conclude that the state of pregnancy in Gambian women induces a progressive rise in 24-h EE, which becomes significant in the third trimester and is proportional to body weight.
Resumo:
Several recent studies suggest that obesity may be a risk factor for fracture. The aim of this study was to investigate the association between body mass index (BMI) and future fracture risk at different skeletal sites. In prospective cohorts from more than 25 countries, baseline data on BMI were available in 398,610 women with an average age of 63 (range, 20-105) years and follow up of 2.2 million person-years during which 30,280 osteoporotic fractures (6457 hip fractures) occurred. Femoral neck BMD was measured in 108,267 of these women. Obesity (BMI ≥ 30 kg/m(2) ) was present in 22%. A majority of osteoporotic fractures (81%) and hip fractures (87%) arose in non-obese women. Compared to a BMI of 25 kg/m(2) , the hazard ratio (HR) for osteoporotic fracture at a BMI of 35 kg/m(2) was 0.87 (95% confidence interval [CI], 0.85-0.90). When adjusted for bone mineral density (BMD), however, the same comparison showed that the HR for osteoporotic fracture was increased (HR, 1.16; 95% CI, 1.09-1.23). Low BMI is a risk factor for hip and all osteoporotic fracture, but is a protective factor for lower leg fracture, whereas high BMI is a risk factor for upper arm (humerus and elbow) fracture. When adjusted for BMD, low BMI remained a risk factor for hip fracture but was protective for osteoporotic fracture, tibia and fibula fracture, distal forearm fracture, and upper arm fracture. When adjusted for BMD, high BMI remained a risk factor for upper arm fracture but was also a risk factor for all osteoporotic fractures. The association between BMI and fracture risk is complex, differs across skeletal sites, and is modified by the interaction between BMI and BMD. At a population level, high BMI remains a protective factor for most sites of fragility fracture. The contribution of increasing population rates of obesity to apparent decreases in fracture rates should be explored. © 2014 American Society for Bone and Mineral Research.
Resumo:
Objective: to assess the between and within-device reproducibility, as well as within-day variability of body fat measurements. Methods: body fat percentage (%BF) was measured twice on seventeen female students aged between 18 and 20 with a body mass index of 21.9 22.6 kg/m2 (mean SD) using seven bipolar bioelectrical impedance devices (BF-306) according to the manufacturer's recommendations. Each student was also measured each hour between 7:00 and 22:00. Statistical analysis was conducted using a general linear model for repeated measurements. Results: the correlation between first and second measurements was very high (Pearson r between 0.985 and 1.000, p<0.001), as well as the correlation between devices (Pearson r between 0.986 and 0.999, all p<0.001). Repeated measurements analysis showed no differences were between devices (F test=0.83, p=0.59) or readings (first vs. second: F test=0.12, p=0.74). Conversely, significant differences were found between assessment periods throughout the day, measurements made in the morning being lower than those made in the afternoon. Assuming an overall daily average of 100 (based on all measurements), the values were 95.8 3.2 (mean SD) at 8:00 versus 101.3 3.0 at 20:00, corresponding to a mean change of 2.2 1.1 in %BF (F test for repeated values=6.58, p<0.001). Conclusions: the between and within-device reproducibility for measuring body fat is high, enabling the use of multiple devices in a single study. Conversely, small but significant changes in body fat measurements occur during the day, urging body fat measurements to be performed at fixed times.
Resumo:
The endocannabinoid (eCB) system can promote food intake by increasing odor detection in mice. The eCB system is over-active in human obesity. Our aim is to measure circulating eCB concentrations and olfactory capacity in a human sample that includes people with obesity and explore the possible interaction between olfaction, obesity and the eCB system. The study sample was made up of 161 females with five groups of body mass index sub-categories ranging from under-weight to morbidly obese. We assessed olfactory capacity with the "Sniffin´Sticks" test, which measures olfactory threshold-discrimination-identification (TDI) capacity. We measured plasma concentrations of the eCBs 2-arachidonoylglycerol (2-AG) and N-arachidonoylethanolamine or anandamide (AEA), and several eCB-related compounds, 2-acylglycerols and N-acylethanolamines. 2-AG and other 2-acylglycerols fasting plasma circulating plasma concentrations were higher in obese and morbidly obese subjects. AEA and other N-acylethanolamine circulating concentrations were lower in under-weight subjects. Olfactory TDI scores were lower in obese and morbidly obese subjects. Lower TDI scores were independently associated with higher 2-AG fasting plasma circulating concentrations, higher %body fat, and higher body mass index, after controlling for age, smoking, menstruation, and use of contraceptives. Our results show that obese subjects have a lower olfactory capacity than non-obese ones and that elevated fasting plasma circulating 2-AG concentrations in obesity are linked to a lower olfactory capacity. In agreement with previous studies we show that eCBs AEA and 2-AG, and their respective congeners have a distinct profile in relation to body mass index. The present report is the first study in humans in which olfactory capacity and circulating eCB concentrations have been measured in the same subjects.
Resumo:
Visceral adiposity is increasingly recognized as a key condition for the development of obesity related disorders, with the ratio between visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) reported as the best correlate of cardiometabolic risk. In this study, using a cohort of 40 obese females (age: 25-45 y, BMI: 28-40 kg/m(2)) under healthy clinical conditions and monitored over a 2 weeks period we examined the relationships between different body composition parameters, estimates of visceral adiposity and blood/urine metabolic profiles. Metabonomics and lipidomics analysis of blood plasma and urine were employed in combination with in vivo quantitation of body composition and abdominal fat distribution using iDXA and computerized tomography. Of the various visceral fat estimates, VAT/SAT and VAT/total abdominal fat ratios exhibited significant associations with regio-specific body lean and fat composition. The integration of these visceral fat estimates with metabolic profiles of blood and urine described a distinct amino acid, diacyl and ether phospholipid phenotype in women with higher visceral fat. Metabolites important in predicting visceral fat adiposity as assessed by Random forest analysis highlighted 7 most robust markers, including tyrosine, glutamine, PC-O 44∶6, PC-O 44∶4, PC-O 42∶4, PC-O 40∶4, and PC-O 40∶3 lipid species. Unexpectedly, the visceral fat associated inflammatory profiles were shown to be highly influenced by inter-days and between-subject variations. Nevertheless, the visceral fat associated amino acid and lipid signature is proposed to be further validated for future patient stratification and cardiometabolic health diagnostics.
Resumo:
This corrects the article on p. e73445 in vol. 8.]. This corrects the article "Topographical Body Fat Distribution Links to Amino Acid and Lipid Metabolism in Healthy Non-Obese Women" , e73445. There was an error in the title of the article. The correct version of the title in the article is: Topographical Body Fat Distribution Links to Amino Acid and Lipid Metabolism in Healthy Obese Women The correct citation is: Martin F-PJ, Montoliu I, Collino S, Scherer M, Guy P, et al. (2013) Topographical Body Fat Distribution Links to Amino Acid and Lipid Metabolism in Healthy Obese Women. PLoS ONE 8(9): e73445. doi:10.1371/journal.pone.0073445
Resumo:
BACKGROUND: Intraabdominal adipose tissue (IAAT) is the body fat depot most strongly related to disease risk. Weight reduction is advocated for overweight people to reduce total body fat and IAAT, although little is known about the effect of weight loss on abdominal fat distribution in different races. OBJECTIVE: We compared the effects of diet-induced weight loss on changes in abdominal fat distribution in white and black women. DESIGN: We studied 23 white and 23 black women, similar in age and body composition, in the overweight state [mean body mass index (BMI; in kg/m(2)): 28.8] and the normal-weight state (mean BMI: 24.0) and 38 never-overweight control women (mean BMI: 23.4). We measured total body fat by using a 4-compartment model, trunk fat by using dual-energy X-ray absorptiometry, and cross-sectional areas of IAAT (at the fourth and fifth lumbar vertebrae) and subcutaneous abdominal adipose tissue (SAAT) by using computed tomography. RESULTS: Weight loss was similar in white and black women (13.1 and 12.6 kg, respectively), as were losses of total fat, trunk fat, and waist circumference. However, white women lost more IAAT (P < 0.001) and less SAAT (P < 0.03) than did black women. Fat patterns regressed toward those of their respective control groups. Changes in waist circumference correlated with changes in IAAT in white women (r = 0.54, P < 0.05) but not in black women (r = 0.19, NS). CONCLUSIONS: Despite comparable decreases in total and trunk fat, white women lost more IAAT and less SAAT than did black women. Waist circumference was not a suitable surrogate marker for tracking changes in the visceral fat compartment in black women.
Resumo:
Components of daily energy expenditure were measured serially by whole-body calorimetry in Gambian women before pregnancy and at 6, 12, 18, 24, 30, and 36 wk gestation. Weight gain was (mean +/- SD) 6.8 +/- 2.8 kg, fat deposition was 2.0 +/- 2.5 kg and lean tissue deposition was 5.0 +/- 2.5 kg. Basal metabolic rate (BMR) was depressed during the first 18 wk of gestation, causing total cumulative maintenance costs by week 36 to be 8.4 MJ. Individual responses to pregnancy correlated with changes in body mass (36 wk: delta BMR vs delta weight; r = 0.60, P < 0.01 delta BMR vs delta LBM; r = 0.62, P < 0.01). There was no significant increase in the cost of treadmill exercise (0% slope: F = 0.71, P = 0.64; 5% slope: F = 1.97, P = 0.10), 24-h energy expenditure (F = 0.72, P = 0.64), activity or diet-induced thermogenesis (F = 1.02, P = 0.43), during pregnancy in spite of body weight gain. Total metabolic costs over 36 wk were 144 MJ (fetus 43 MJ, fat deposition 92 MJ, cumulative maintenance costs 8.4 MJ). These were far lower than reported for well-nourished Western populations.
Resumo:
OBJECTIVES: To test the validity of a simple, rapid, field-adapted, portable hand-held impedancemeter (HHI) for the estimation of lean body mass (LBM) and percentage body fat (%BF) in African women, and to develop specific predictive equations. DESIGN: Cross-sectional observational study. SETTINGS: Dakar, the capital city of Senegal, West Africa. SUBJECTS: A total sample of 146 women volunteered. Their mean age was of 31.0 y (s.d. 9.1), weight 60.9 kg (s.d. 13.1) and BMI 22.6 kg/m(2) (s.d. 4.5). METHODS: Body composition values estimated by HHI were compared to those measured by whole body densitometry performed by air displacement plethysmography (ADP). The specific density of LBM in black subjects was taken into account for the calculation of %BF from body density. RESULTS: : Estimations from HHI showed a large bias (mean difference) of 5.6 kg LBM (P<10(-4)) and -8.8 %BF (P<10(-4)) and errors (s.d. of the bias) of 2.6 kg LBM and 3.7 %BF. In order to correct for the bias, specific predictive equations were developed. With the HHI result as a single predictor, error values were of 1.9 kg LBM and 3.7 %BF in the prediction group (n=100), and of 2.2 kg LBM and 3.6 %BF in the cross-validation group (n=46). Addition of anthropometrical predictors was not necessary. CONCLUSIONS: The HHI analyser significantly overestimated LBM and underestimated %BF in African women. After correction for the bias, the body compartments could easily be estimated in African women by using the HHI result in an appropriate prediction equation with a good precision. It remains to be seen whether a combination of arm and leg impedancemetry in order to take into account lower limbs would further improve the prediction of body composition in Africans.
Resumo:
Two studies were performed to investigate the association between body fat mass and fat oxidation. The first, a cross-sectional study of 106 obese women maintaining stable body weight, showed that these two variables were significantly correlated (r = 0.56, P less than 0.001) and the regression coefficient indicated that a 10-kg change in fat mass corresponded to a change in fat oxidation of approximately 20 g/d. The second, a prospective study, validated this estimate and quantifies the long-term adaptations in fat oxidation resulting from body fat loss. Twenty-four moderately obese women were studied under controlled dietary conditions at stable weight before and after mean weight and fat losses of 12.7 and 9.8 kg, respectively. The reduction in fat oxidation was identical to that predicted by the above regression. We conclude that changes in fat mass significantly affect fat oxidation and that this process may contribute to the long-term regulation of fat and energy balance in obese individuals.
Resumo:
PURPOSE: To evaluate the prevalence of common mental disorders in women diagnosed with polycystic ovary syndrome as compared with paired controls without this syndrome. METHODS: Cross-sectional study with a Control Group examining women between the ages of 18 and 30 who did not use antidepressants and who sought the Gynecology Service of the researched sites. For every woman diagnosed with the polycystic ovary syndrome, another with the same age, educational status and presence or absence of sexual partners was sought without this diagnosis. In total, 166 patients agreed to participate, consisting of 95 diagnosed with polycystic ovary syndrome and 71 in the Control Group. The diagnosis of polycystic ovary syndrome was made by the presence of two from three criteria: oligomenorrhea or amenorrhea, clinical or biochemical hyperandrogenism and polycystic ovaries on transvaginal ultrasound, following exclusion of patients with Cushing's syndrome, congenital adrenal hyperplasia, and androgen-secreting tumors. Weight and height were measured to calculate the body mass index. The Self-Reporting Questionnaire, which evaluated 20 items, was used as an indicator of common mental disorders. A χ² analysis stratified by the category of body mass index was used to compare the prevalence of common mental disorders, between the groups of women with and without the polycystic ovary syndrome. RESULTS: There were no significant differences in age, education, presence of sexual partners, ethnicity, socioeconomic status, use of psychiatric medication, and search for consultation in mental health between the studied groups. The prevalence of obese women with indications of common mental disorders was significantly higher in women with polycystic ovary syndrome than in the Control Group. In the group with healthy body mass index, the incidence of common mental disorders was statistically significant different between women with polycystic ovary syndrome and normal controls (p=0.008). CONCLUSIONS: Women with diagnosis of this disease have an almost three-fold increased likelihood of common mental disorders as compared with those without polycystic ovary syndrome. Although obesity is often observed in polycystic ovary syndrome, even women with a healthy body mass index have an increased risk of psychiatric comorbidity.