957 resultados para allocation of fixed cost with normal capacity
Resumo:
There is still controversy about the relation between changes in myocardial contractile function and global left ventricular (LV) performance during stable concentric hypertrophy. To clarify this, we analyzed LV function in vivo and myocardial mechanics in vitro in rats with pressure overload-induced cardiac hypertrophy. Male Wistar rats (70 g) Underwent ascending aortic stenosis for 8 weeks (group AAS, n = 9). LV performance wits assessed by transthoracic echocardiography Under anesthesia. Myocardial function Was studied in isolated papillary muscle preparations during isometric contraction. The data were compared with age- and sex-matched sham-operated rats (group C, 11 = 9). LV weight-to-body weight ratio (C: 2.13 +/- 0.14 mg/g; AAS: 3.24 +/- 0.44) LV relative wall thickness (C: 0.18 +/- 0.02; AAS: 0.33 +/- 0.09), and LV fractional shortening (C: 54 +/- 5%; AAS: 70 +/- 8%) were increased in group AAS (P<0.05). Echocardio-graphic analysis also indicated a significant association (r = 0.74 P<0.001) between the percent fractional shortening index and LV relative wall thickness. The performance of AAS isolated In muscle revealed that active tension (C: 6.6 +/- 1.7 g/mm(2); AAS: 6.5 +/- 1.5 g/mm(2)) and maximum rate of tension development (C: 69 +/- 21 g/mm(2)/s AAS: 69 +/- 18 g/mm(2)/s) were not significantly different Front group C (P>0.05). In conclusion, compensated pressure-overload myocardial hypertrophy is associated with preserved myocardial function and increased ventricular performance. The improved LV function might be due to the ventricular remodeling, characterized by an increased relative wall thickness.
Resumo:
In this paper, we have investigated a region of direct stable orbits around the Moon, whose stability is related to the H2 Family of periodic orbits and to the quasi-periodic orbits that oscillate around them. The stability criteria adopted was that the path did not escape from the Moon during an integration period of 1000 days (remaining with negative two-body Moon-probe orbital energy during this period). Considering the three-dimensional four-body Sun-Earth-Moon-probe problem, we investigated the evolution of the size of the stability region, taking into account the eccentricity of the Earth's orbit, the eccentricity and inclination of the Moon's orbit, and the solar radiation pressure on the probe. We also investigated the evolution of the region's size and its location by varying the inclination of the probe's initial osculating orbit relative to the Moon's orbital plane between 0 degrees and 180 degrees. The size of the stability region diminishes; nevertheless, it remains significant for 0 <= i <= 25 degrees and 35 degrees <= i <= 45 degrees. The orbits of this region could be useful for missions by space vehicles that must remain in orbit around the Moon for periods of up to 1000 days, requiring low maintenance costs. (c) 2005 COSPAR. Published by Elsevier Ltd. All rights reserved.
Resumo:
In this work we have demonstrated the effects of oral administration of Chlorella vulgaris (CV) on Natural Killer cells (NK) activity of mice infected with a sublethal dose of viable Listeria monocytogenes. The treatment with C. vulgaris produced a significant increase on NK cells activity in normal (non-infected) animals compared to the animals that received only vehicle (water) (p < 0.0001). Similarly, the infection alone produced a significant increase on NK cells activity, which was observed at 48 and 72 hours after the inoculation of L. monocytogenes. Moreover, when CV was administered in infected animals, there was an additional increase in NK cells activity which was significantly higher than that found in the infected groups (p < 0.0001) CV treatment (50 and 500mg/Kg) of mice infected with a dose of 3x105 bacteria/animal, which was lethal for all the non- treated controls, produced a dose-response protection which led to a 20% and 55% survival, respectively (p < 0.0001).
Resumo:
There still controversy about the relation between changes in myocardial contractile function and global left ventricular (LV) performance during stable concentric hypertrophy. To clarify this, we analyzed LV function in vivo and myocardial mechanics in vitro in rats with pressure overload-induced cardiac hypertrophy. Male Wistar rats (70 g) underwent ascending aorta stenosis for 8 weeks (group AAS, n=9). LV performance was assessed by transthoracic echocardiography under light anesthesia. Myocardial function was studied in isolated papillary muscle preparation during isometric contraction. The data were compared with age- and sex-matched sham-operated rats (group C, n=9). LV weight-to-body weight ratio (C: 2.0 ± 0.5 mg/g; AAS: 3.3 ± 0.7 mg/g), LV relative wall thickness (C: 0.19 ± 0.02; AAS; 0.34 ± 0.10), and LV fractional shortening (C: 54 ± 5%; AAS: 70 ± 8%) were increased in the group AAS (p<0.05). Echocardiographic analysis also indicated a significant association (r=0.74; p<0.001) between percent fractional shortening and LV relative wall thickness. The performance of AAS isolated muscle revealed that active tension (C: 6.6 ± 1.7 g/mm 2; AAS: 6.5 ± 1.5 g/mm 2) and maximum rate of tension development (C: 69 ± 21 g/mm 2/s; AAS: 69 ± 18 g/mm 2) were not significantly different from group C (p>0.05). In conclusion: 1) Compensated pressure-overload myocardial hypertrophy is associated with preserved myocardial function and increased ventricular performance; 2) The improved LV function might be due to the ventricular remodeling characterized by an increased relative wall thickness. Copyright © 2002 By PJD Publications Limited.
Resumo:
Linear mixed effects models have been widely used in analysis of data where responses are clustered around some random effects, so it is not reasonable to assume independence between observations in the same cluster. In most biological applications, it is assumed that the distributions of the random effects and of the residuals are Gaussian. This makes inferences vulnerable to the presence of outliers. Here, linear mixed effects models with normal/independent residual distributions for robust inferences are described. Specific distributions examined include univariate and multivariate versions of the Student-t, the slash and the contaminated normal. A Bayesian framework is adopted and Markov chain Monte Carlo is used to carry out the posterior analysis. The procedures are illustrated using birth weight data on rats in a texicological experiment. Results from the Gaussian and robust models are contrasted, and it is shown how the implementation can be used for outlier detection. The thick-tailed distributions provide an appealing robust alternative to the Gaussian process in linear mixed models, and they are easily implemented using data augmentation and MCMC techniques.
Resumo:
Reliability of power supply is related, among other factors, to the control and protection devices allocation in feeders of distribution systems. In this way, optimized allocation of sectionalizing switches and protection devices in strategic points of distribution circuits, improves the quality of power supply and the system reliability indices. In this work, it is presented a mixed integer non-linear programming (MINLP) model, with real and binary variables, for the sectionalizing switches and protection devices allocation problem, in strategic sectors, aimed at improving reliability indices, increasing the utilities billing and fulfilling exigencies of regulatory agencies for the power supply. Optimized allocation of protection devices and switches for restoration, allows that those faulted sectors of the system can be isolated and repaired, re-managing loads of the analyzed feeder into the set of neighbor feeders. Proposed solution technique is a Genetic Algorithm (GA) developed exploiting the physical characteristics of the problem. Results obtained through simulations for a real-life circuit, are presented. © 2004 IEEE.
Resumo:
Distribution systems with distributed generation require new analysis methods since networks are not longer passive. Two of the main problems in this new scenario are the network reconfiguration and the loss allocation. This work presents a distribution systems graphic simulator, developed with reconfiguration functions and a special focus on loss allocation, both considering the presence of distributed generation. This simulator uses a fast and robust power flow algorithm based on the current summation backward-forward technique. Reconfiguration problem is solved through a heuristic methodology and the losses allocation function, based on the Zbus method, is presented as an attached result for each obtained configuration. Results are presented and discussed, remarking the easiness of analysis through the graphic simulator as an excellent tool for planning and operation engineers, and very useful for training. © 2004 IEEE.
Resumo:
With the exception of the cleft lip, developmental defects (DD) of the lip are rare. The upper lip originates from the ectomesenchyme and is formed by the merging of the nasal medial and lateral processes with the maxillary process. Disturbances during this formation period can cause DD with functional and/or esthetic repercussions. We present a case of DD of the upper lip in a patient with a history of progressive growth of the left lateral portion of the upper lip that occurred from the time of birth until the age of 22 years. Clinical examination revealed hypertrophy of the area from the left philtral columns to the left commissure of the lip, extending the portion of the surface mucosa creating a flaccid and asymptomatic tissue mass. All other buccal structures appeared to be within normal limits and without any evidence of defects or deformities. In the surgical planning we decided to carry out corrective surgery in two phases. The first phase accomplished a conservative excision of the total abnormal labial tissue mass with a CO2 laser radiation (5 W in continuous mode, bunch diameter φ = 0.6 mm with a power density of 768 W/cm2 and fluency of 0.231 J/cm2) being careful to preserve the vermilion portion of the lip. Postsurgical clinical evaluations were done every three days until the skin sutures were removed and then every seven days until two months post surgery. While the entire mass of excessive tissue could not be completely removed, the removal of the excessive mucosal tissue produced a very good outcome relative to lip function, with a good esthetic result without scarring, and good tissue mobility. The results showed that the CO2 laser is an extremely useful instrument that can provide excellent control of the surgical field and allow for healing that produces excellent functional and esthetic results. © 2005 Taylor & Francis.
Resumo:
Open access philosophy applied by regulatory agencies may lead to a scenario where captive consumers will solely face the responsibility on distribution network's losses even with Independent Energy Producers (also known as Distributed Generation) and Independent Energy Consumers connected to the system. This work proposes the utilization of a loss allocation method in distribution systems where open access is allowed, in which cross-subsidies, that appear due to the influence the generators have over the system losses, are minimized. Thus, guaranteeing to some extent the efficiency and transparency of the economic signals of the market. Results obtained through the Zbus loss allocation method adapted for distribution networks are processed in such a way that the corresponding allocation to the generation buses is divided among the consumer buses, while still considering consumers spatial characteristics. © 2007 IEEE.
Resumo:
Hemoglobinopathies were included in the Brazilian Neonatal Screening Program on June 6, 2001. Automated high-performance liquid chromatography (HPLC) was indicated as one of the diagnostic methods. The amount of information generated by these systems is immense, and the behavior of groups cannot always be observed in individual analyses. Three-dimensional (3-D) visualization techniques can be applied to extract this information, for extracting patterns, trends or relations from the results stored in databases. We applied the 3-D visualization tool to analyze patterns in the results of hemoglobinopathy based on neonatal diagnosis by HPLC. The laboratory results of 2520 newborn analyses carried out in 2001 and 2002 were used. The Fast, F1, F and A peaks, which were detected by the analytical system, were chosen as attributes for mapping. To establish a behavior pattern, the results were classified into groups according to hemoglobin phenotype: normal (N = 2169), variant (N = 73) and thalassemia (N = 279). 3-D visualization was made with the FastMap DB tool; there were two distribution patterns in the normal group, due to variation in the amplitude of the values obtained by HPLC for the F1 window. It allowed separation of the samples with normal Hb from those with alpha thalassemia, based on a significant difference (P > 0.05) between the mean values of the Fast and A peaks, demonstrating the need for better evaluation of chromatograms; this method could be used to help diagnose alpha thalassemia in newborns.
Resumo:
This work presents a study regarding the optimization of multipulse converters. A general expression for the connection (Δ or Y) for both 12 and 18-pulses is obtained and describes the output voltages on the secondary windings, depending on the voltage reference from the primary. These generalized expressions allows choosing different ratios between input and output voltages and as result an optimum operation point for the converter can be calculated. Considering Δ-connected converters the optimum point occurs when the magnetic core of the autotransformer processes 18% and 17% of the output power for 12 and 18-pulses, respectively. For Y-connected converters the optimum point occurs when the kVA rating is 13% and 18% for 12 and 18-pulses, respectively. Based on these results magnetic elements can be calculated and designed leading to a great weight and volume reduction and also to lower costs and losses. Finally an analysis is made to improve the kVA rating of the transformers for 12 and 18 pulses converters. © 2009 IEEE.
Resumo:
The aim of this study was to validate a non-invasive protocol to determine aerobic and anaerobic capacity of treadmill running rats. Thirteen male Wistar rats (90 days old) were submitted to 4 exercise tests, consisting of running at 25, 30, 35 and 40 m min-1, continuously until exhaustion. For the critical velocity (CV) and anaerobic running capacity (ARC) estimations, the hyperbolic curve (velocity versus time to exhaustion (tlim)) was linearized to V= CV+ARC/tlim, where the CV and ARC were linear and slope coefficients, respectively. In order to verify if the CV was the maximal aerobic intensity, the rats were submitted to the maximal lactate steady state test (MLSS) composed of three 25-minute tests of continuous running trials at 15, 20 and 25 m min-1, with blood collection every 5 minutes. The CV was obtained at 22.8±0.7 m min-1 and the ARC, at 26.80±2.77 m. The MLSS was observed at 20m min-1, with blood lactate 3.84 ± 0.31 mmol L-1. There was a progressive increase in lactate concentration at 25 m min-1. The CV and MLSS were different, but presented a high and significant correlation (r=0.81). These results indicate that the non-invasive protocol can be used for physical evaluation of aerobic running rats, but the ARC should still be further investigated.
Resumo:
Problems as voltage increase at the end of a feeder, demand supply unbalance in a fault condition, power quality decline, increase of power losses, and reduction of reliability levels may occur if Distributed Generators (DGs) are not properly allocated. For this reason, researchers have been employed several solution techniques to solve the problem of optimal allocation of DGs. This work is focused on the ancillary service of reactive power support provided by DGs. The main objective is to price this service by determining the costs in which a DG incurs when it loses sales opportunity of active power, i.e, by determining the Loss of Opportunity Costs (LOC). The LOC will be determined for different allocation alternatives of DGs as a result of a multi-objective optimization process, aiming the minimization of losses in the lines of the system and costs of active power generation from DGs, and the maximization of the static voltage stability margin of the system. The effectiveness of the proposed methodology in improving the goals outlined was demonstrated using the IEEE 34 bus distribution test feeder with two DGs cosidered to be allocated. © 2011 IEEE.
Resumo:
Tooth replacement in the maxillary anterior region is especially difficult when the loss includes significant amounts of the residual ridge and the soft tissue. Several techniques are available, such as dental implants or fixed partial denture, and bone and gingival grafts or gingival prostheses, respectively. This article showed a clinical case of an elderly who was treated with a collarless metal-ceramic fixed partial denture and acrylic removable gingival prosthesis to recover the esthetics in the maxillary anterior region. The association of a metal-ceramic fixed denture and gingival prosthesis was an excellent alternative in cases when surgical procedures are contraindicated. © 2012 Japan Prosthodontic Society.
Resumo:
Aim: This study evaluates bond strength between dentin and composite using adhesives with different solvents to dry and wet dentin. Materials and methods: Ninety bovine incisors were used; the vestibular surfaces were worn by the exposure of an area with a diameter of 4 mm of dentin. The specimens were divided into 6 groups, according to the type of adhesive used and hydratation stals: Group SB-wet: Single Bond 2 in wet dentin, Group SBdry: Single Bond 2 in dry dentin, Group SL-wet: Solobond M in wet dentin, Group SL-dry: Solobond M in dentin dry. Group XPwet: XP Bond in wet dentin, Group XP-dry: XP Bond in dentin dry. They were cut to obtain specimens in the shape of stick with 1 × 1 mm and subjected to microtensile test in universal testing machine with a cross speed of 1mm/min. The data were analyzed with ANOVA and Tukey's tests (5%). Results: ANOVA showed significant differences for surface treatment and interaction, but no difference was found for adhesive factor. The Tukey's test showed that the samples with wet dentin shown higher values of bond strength. Conclusion: The adhesive did not influence in the bond strength. The groups with wet dentin showed higher values of bond strength than groups with dry dentin.