943 resultados para Volumetric capacitances
Resumo:
BACKGROUND: Variation in brain structure is both genetically and environmentally influenced. The question about potential differences in brain anatomy across populations of differing race and ethnicity remains a controversial issue. There are few studies specifically examining racial or ethnic differences and also few studies that test for race-related differences in context of other neuropsychiatric research, possibly due to the underrepresentation of ethnic minorities in clinical research. It is within this context that we conducted a secondary data analysis examining volumetric MRI data from healthy participants and compared the volumes of the amygdala, hippocampus, lateral ventricles, caudate nucleus, orbitofrontal cortex (OFC) and total cerebral volume between Caucasian and African-American participants. We discuss the importance of this finding in context of neuroimaging methodology, but also the need for improved recruitment of African Americans in clinical research and its broader implications for a better understanding of the neural basis of neuropsychiatric disorders. METHODOLOGY/PRINCIPAL FINDINGS: This was a case control study in the setting of an academic medical center outpatient service. Participants consisted of 44 Caucasians and 33 ethnic minorities. The following volumetric data were obtained: amygdala, hippocampus, lateral ventricles, caudate nucleus, orbitofrontal cortex (OFC) and total cerebrum. Each participant completed a 1.5 T magnetic resonance imaging (MRI). Our primary finding in analyses of brain subregions was that when compared to Caucasians, African Americans exhibited larger left OFC volumes (F (1,68) = 7.50, p = 0.008). CONCLUSIONS: The biological implications of our findings are unclear as we do not know what factors may be contributing to these observed differences. However, this study raises several questions that have important implications for the future of neuropsychiatric research.
Resumo:
The outcomes for both (i) radiation therapy and (ii) preclinical small animal radio- biology studies are dependent on the delivery of a known quantity of radiation to a specific and intentional location. Adverse effects can result from these procedures if the dose to the target is too high or low, and can also result from an incorrect spatial distribution in which nearby normal healthy tissue can be undesirably damaged by poor radiation delivery techniques. Thus, in mice and humans alike, the spatial dose distributions from radiation sources should be well characterized in terms of the absolute dose quantity, and with pin-point accuracy. When dealing with the steep spatial dose gradients consequential to either (i) high dose rate (HDR) brachytherapy or (ii) within the small organs and tissue inhomogeneities of mice, obtaining accurate and highly precise dose results can be very challenging, considering commercially available radiation detection tools, such as ion chambers, are often too large for in-vivo use.
In this dissertation two tools are developed and applied for both clinical and preclinical radiation measurement. The first tool is a novel radiation detector for acquiring physical measurements, fabricated from an inorganic nano-crystalline scintillator that has been fixed on an optical fiber terminus. This dosimeter allows for the measurement of point doses to sub-millimeter resolution, and has the ability to be placed in-vivo in humans and small animals. Real-time data is displayed to the user to provide instant quality assurance and dose-rate information. The second tool utilizes an open source Monte Carlo particle transport code, and was applied for small animal dosimetry studies to calculate organ doses and recommend new techniques of dose prescription in mice, as well as to characterize dose to the murine bone marrow compartment with micron-scale resolution.
Hardware design changes were implemented to reduce the overall fiber diameter to <0.9 mm for the nano-crystalline scintillator based fiber optic detector (NanoFOD) system. Lower limits of device sensitivity were found to be approximately 0.05 cGy/s. Herein, this detector was demonstrated to perform quality assurance of clinical 192Ir HDR brachytherapy procedures, providing comparable dose measurements as thermo-luminescent dosimeters and accuracy within 20% of the treatment planning software (TPS) for 27 treatments conducted, with an inter-quartile range ratio to the TPS dose value of (1.02-0.94=0.08). After removing contaminant signals (Cerenkov and diode background), calibration of the detector enabled accurate dose measurements for vaginal applicator brachytherapy procedures. For 192Ir use, energy response changed by a factor of 2.25 over the SDD values of 3 to 9 cm; however a cap made of 0.2 mm thickness silver reduced energy dependence to a factor of 1.25 over the same SDD range, but had the consequence of reducing overall sensitivity by 33%.
For preclinical measurements, dose accuracy of the NanoFOD was within 1.3% of MOSFET measured dose values in a cylindrical mouse phantom at 225 kV for x-ray irradiation at angles of 0, 90, 180, and 270˝. The NanoFOD exhibited small changes in angular sensitivity, with a coefficient of variation (COV) of 3.6% at 120 kV and 1% at 225 kV. When the NanoFOD was placed alongside a MOSFET in the liver of a sacrificed mouse and treatment was delivered at 225 kV with 0.3 mm Cu filter, the dose difference was only 1.09% with use of the 4x4 cm collimator, and -0.03% with no collimation. Additionally, the NanoFOD utilized a scintillator of 11 µm thickness to measure small x-ray fields for microbeam radiation therapy (MRT) applications, and achieved 2.7% dose accuracy of the microbeam peak in comparison to radiochromic film. Modest differences between the full-width at half maximum measured lateral dimension of the MRT system were observed between the NanoFOD (420 µm) and radiochromic film (320 µm), but these differences have been explained mostly as an artifact due to the geometry used and volumetric effects in the scintillator material. Characterization of the energy dependence for the yttrium-oxide based scintillator material was performed in the range of 40-320 kV (2 mm Al filtration), and the maximum device sensitivity was achieved at 100 kV. Tissue maximum ratio data measurements were carried out on a small animal x-ray irradiator system at 320 kV and demonstrated an average difference of 0.9% as compared to a MOSFET dosimeter in the range of 2.5 to 33 cm depth in tissue equivalent plastic blocks. Irradiation of the NanoFOD fiber and scintillator material on a 137Cs gamma irradiator to 1600 Gy did not produce any measurable change in light output, suggesting that the NanoFOD system may be re-used without the need for replacement or recalibration over its lifetime.
For small animal irradiator systems, researchers can deliver a given dose to a target organ by controlling exposure time. Currently, researchers calculate this exposure time by dividing the total dose that they wish to deliver by a single provided dose rate value. This method is independent of the target organ. Studies conducted here used Monte Carlo particle transport codes to justify a new method of dose prescription in mice, that considers organ specific doses. Monte Carlo simulations were performed in the Geant4 Application for Tomographic Emission (GATE) toolkit using a MOBY mouse whole-body phantom. The non-homogeneous phantom was comprised of 256x256x800 voxels of size 0.145x0.145x0.145 mm3. Differences of up to 20-30% in dose to soft-tissue target organs was demonstrated, and methods for alleviating these errors were suggested during whole body radiation of mice by utilizing organ specific and x-ray tube filter specific dose rates for all irradiations.
Monte Carlo analysis was used on 1 µm resolution CT images of a mouse femur and a mouse vertebra to calculate the dose gradients within the bone marrow (BM) compartment of mice based on different radiation beam qualities relevant to x-ray and isotope type irradiators. Results and findings indicated that soft x-ray beams (160 kV at 0.62 mm Cu HVL and 320 kV at 1 mm Cu HVL) lead to substantially higher dose to BM within close proximity to mineral bone (within about 60 µm) as compared to hard x-ray beams (320 kV at 4 mm Cu HVL) and isotope based gamma irradiators (137Cs). The average dose increases to the BM in the vertebra for these four aforementioned radiation beam qualities were found to be 31%, 17%, 8%, and 1%, respectively. Both in-vitro and in-vivo experimental studies confirmed these simulation results, demonstrating that the 320 kV, 1 mm Cu HVL beam caused statistically significant increased killing to the BM cells at 6 Gy dose levels in comparison to both the 320 kV, 4 mm Cu HVL and the 662 keV, 137Cs beams.
Resumo:
It is widely accepted that volumetric contraction and solidification during the polymerization process of restorative composites in combination with bonding to the hard tissue result in stress transfer and inward deformation of the cavity walls of the restored tooth. Deformation of the walls decreases the size of the cavity during the filling process. This fact has a profound influence on the assumption-raised and discussed in this paper-that an incremental filling technique reduces the stress effect of composite shrinkage on the tooth. Developing stress fields for different incremental filling techniques are simulated in a numerical analysis. The analysis shows that, in a restoration with a well-established bond to the tooth-as is generally desired-incremental filling techniques increase the deformation of the restored tooth. The increase is caused by the incremental deformation of the preparation, which effectively decreases the total amount of composite needed to fill the cavity. This leads to a higher-stressed tooth-composite structure. The study also shows that the assessment of intercuspal distance measurements as well as simplifications based on generalization of the shrinkage stress state cannot be sufficient to characterize the effect of polymerization shrinkage in a tooth-restoration complex. Incremental filling methods may need to be retained for reasons such as densification, adaptation, thoroughness of cure, and bond formation. However, it is very difficult to prove that incrementalization needs to be retained because of the abatement of shrinkage effects.
Resumo:
Numerical predictions produced by the SMARTFIRE fire field model are compared with experimental data. The predictions consist of gas temperatures at several locations within the compartment over a 60 min period. The test fire, produced by a burning wood crib attained a maximum heat release rate of approximately 11MW. The fire is intended to represent a nonspreading fire (i.e. single fuel source) in a moderately sized ventilated room. The experimental data formed part of the CIB Round Robin test series. Two simulations are produced, one involving a relatively coarse mesh and the other with a finer mesh. While the SMARTFIRE simulations made use of a simple volumetric heat release rate model, both simulations were found capable of reproducing the overall qualitative results. Both simulations tended to overpredict the measured temperatures. However, the finer mesh simulation was better able to reproduce the qualitative features of the experimental data. The maximum recorded experimental temperature (12141C after 39 min) was over-predicted in the fine mesh simulation by 12%. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
A practical CFD method is presented in this study to predict the generation of toxic gases in enclosure fires. The model makes use of local combustion conditions to determine the yield of carbon monoxide, carbon dioxide, hydrocarbon, soot and oxygen. The local conditions used in the determination of these species are the local equivalence ratio (LER) and the local temperature. The heat released from combustion is calculated using the volumetric heat source model or the eddy dissipation model (EDM). The model is then used to simulate a range of reduced-scale and full-scale fire experiments. The model predictions for most of the predicted species are then shown to be in good agreement with the test results
Resumo:
In high intensity and high gradient magnetic fields the volumetric force on diamagnetic material, such as water, leads to conditions very similar to microgravity in a terrestrial laboratory. In principle, this opens the possibility to determine material properties of liquid samples without wall contact, even for electrically non-conducting materials. In contrast, AC field levitation is used for conductors, but then terrestrial conditions lead to turbulent flow driven by Lorentz forces. DC field damping of the flow is feasible and indeed practiced to allow property measurements. However, the AC/DC field combination acts preferentially on certain oscillation modes and leads to a shift in the droplet oscillation spectrum.What is the cause? A nonlinear spectral numerical model is presented, to address these problems
Resumo:
This study presents a CFD analysis constructed around PHYSICA, an open framework for multi-physics computational continuum mechanics modelling, to investigate the water movement in unsaturated porous media. The modelling environment is based on a cell-centred finite-volume discretisation technique. A number of test cases are performed in order to validate the correct implementation of Richard's equation for compressible and incompressible fluids. The pressure head form of the equation is used together with the constitutive relationships between pressure, volumetric water content and hydraulic conductivity described by Haverkamp and Van Genuchten models. The flow problems presented are associated with infiltration into initially dry soils with homogeneous or layered geologic settings. Comparison of results with the problems selected from literature shows a good agreement and validates the approach and the implementation.
Resumo:
In high intensity and high gradient magnetic fields the volumetric force on diamagnetic material, such as water, leads to conditions very similar to microgravity in a terrestrial laboratory. In principle, this opens the possibility to determine material properties of liquid samples without wall contact, even for electrically non-conducting materials. In contrast, AC field levitation is used for conductors, but then terrestrial conditions lead to turbulent flow driven by Lorentz forces. DC field damping of the flow is feasible and indeed practiced to allow property measurements. However, the AC/DC field combination acts preferentially on certain oscillation modes and leads to a shift in the droplet oscillation spectrum.What is the cause? A nonlinear spectral numerical model is presented, to address these problems.
Resumo:
Thermosetting polymer materials are widely utilised in modern microelectronics packaging technology. These materials are used for a number of functions, such as for device bonding, for structural support applications and for physical protection of semiconductor dies. Typically, convection heating systems are used to raise the temperature of the materials to expedite the polymerisation process. The convection cure process has a number of drawbacks including process durations generally in excess of 1 hour and the requirement to heat the entire printed circuit board assembly, inducing thermomechanical stresses which effect device reliability. Microwave energy is able to raise the temperature of materials in a rapid, controlled manner. As the microwave energy penetrates into the polymer materials, the heating can be considered volumetric – i.e. the rate of heating is approximately constant throughout the material. This enables a maximal heating rate far greater than is available with convection oven systems which only raise the surface temperature of the polymer material and rely on thermal conductivity to transfer heat energy into the bulk. The high heating rate, combined with the ability to vary the operating power of the microwave system, enables the extremely rapid cure processes. Microwave curing of a commercially available encapsulation material has been studied experimentally and through use of numerical modelling techniques. The material assessed is Henkel EO-1080, a single component thermosetting epoxy. The producer has suggested three typical convection oven cure options for EO1080: 20 min at 150C or 90 min at 140C or 120 min at 110C. Rapid curing of materials of this type using advanced microwave systems, such as the FAMOBS system [1], is of great interest to microelectronics system manufacturers as it has the potential to reduce manufacturing costs, increase device reliability and enables new device designs. Experimental analysis has demonstrated that, in a realistic chip-on-board encapsulation scenario, the polymer material can be fully cured in approximately one minute. This corresponds to a reduction in cure time of approximately 95 percent relative to the convection oven process. Numerical assessment of the process [2] also suggests that cure times of approximately 70 seconds are feasible whilst indicating that the decrease in process duration comes at the expense of variation in degree of cure within the polymer.
Resumo:
Theoretical and experimental studies of cross correlation techniques applied to non-restrictive velocity measurement of pneumatically conveyed solids using ring-shaped electrodynamic flow sensors are presented. In-depth studies of the electrodynamic sensing mechanism, and also of the spatial sensitivity and spatial filtering properties of the sensor are included, together with their relationships to measurement accuracy and the effects of solids' velocity profiles. The experimental evaluation of a 53 mm bore sensing head is described, including trials using a calibrated pneumatic conveyor circulating pulverized fuel and cement. Comparisons of test results with the mathematical models of the sensor are used to identify important aspects of the instrument design. Off-line test results obtained using gravity-fed solids flow show that the system repeatability is within +/-0.5% over the velocity range of 2-4 m s(-1) for volumetric concentrations of solids no greater than 0.2%. Results obtained in the pilot-plant trials demonstrate that the system is capable of achieving repeatability better than +/-2% and linearity within +/-2% over the velocity range 20-40 m s(-1) for volumetric concentrations of solids in the range 0.01-0.44%.
Resumo:
Using an effective combination of multivariate testing and ordination analyses, this study compares the extents to which the diets of two co-occurring fish species (Pagrus auratus and Pseudocaranx georgianus) are related to body size (length class), season and region and the rank order importance of those effects. Thus, volumetric dietary compositions were determined for these species on the lower west coast of Australia, where both are abundant, and for P. auratus from the mid west coast and P. georgianus from the south coast. The diet of P. auratus on the lower west coast was strongly related to body size and slightly less to season. With increasing body size, its diet shifted from predominantly ophiuroids to larger prey, such as brachyuran crabs, teleosts, echinoids and ultimately asteroids, probably reflecting a shift from foraging over soft sediments to areas over and around reefs. Seasonal changes on the lower west coast were restricted mainly to small P. auratus, while larger fish underwent seasonal changes further north. Analyses using a common size range of medium to larger P. auratus demonstrated that dietary composition differed more between regions than seasons. The relationships between diet and length class of P. georgianus on both the lower west and south coasts were less pronounced than for P. auratus and seasonal changes were restricted to the south coast, where amphipod consumption increased markedly in summer. The diet of P. georgianus was related far more to region than length class and season, with more small teleosts, small crabs, carideans and littorinids and less amphipods, isopods and small bivalves being ingested on the lower west than south coasts. Although crabs and teleosts were important typifying prey of P. auratus and P. georgianus, when co-occurring, the former predator tended to ingest greater volumes of larger and often less mobile prey. This reflects differences in dentition, jaw morphology and feeding behaviour and reduces the potential for competition for food resources. The results imply that P. auratus and P. georgianus are opportunistic feeders and that the effects of length class, season and region on dietary composition and their rank orders can vary markedly between species and for length class and season between regions for the same species.
Resumo:
Many food webs are so complex that it is difficult to distinguish the relationships between predators and their prey. We have therefore developed an approach that produces a food web which clearly demonstrates the strengths of the relationships between the predator guilds of demersal fish and their prey guilds in a coastal ecosystem. Subjecting volumetric dietary data for 35 abundant predators along the lower western Australia coast to cluster analysis and the SIMPROF routine separated the various species x length class combinations into 14 discrete predator guilds. Following nMDS ordination, the sequence of points for these predator guilds represented a 'trophic' hierarchy. This demonstrated that, with increasing body size, several species progressed upwards through this hierarchy, reflecting a marked change in diet, whereas others remained within the same guild. A novel use of cluster analysis and SIMPROF then identified each group of prey that was ingested in a common pattern across the full suite of predator guilds. This produced 12 discrete groups of taxa (prey guilds) that each typically comprised similar ecological/functional prey, which were then also aligned in a hierarchy. The hierarchical arrangements of the predator and prey guilds were plotted against each other to show the percentage contribution of each prey guild to the diet of each predator guild. The resultant shade plot demonstrates quantitatively how food resources are spread among the fish species and revealed that two prey guilds, one containing cephalopods and teleosts and the other small benthic/epibenthic crustaceans and polychaetes, were consumed by all predator guilds.
Resumo:
Knowledge on the impact of climate variability in the diet of planktivorous fish is limited by the laborious work involved in stomach content analysis, impractical for large scale studies. Routine measurements of plankton such as the Continuous Plankton Recorder (CPR) survey provide valuable information of the temporal variation of phyto- and zooplankton prey availability for higher trophic levels. Sardines are a world-wide distributed and commercially important planktivorous fish, at the basis of the pelagic marine food web. Being predominantly non-selective filter-feeders, their diets closely correspond to the water plankton species and a significant relationship was recently found between Sardina pilchardus feeding intensity and remotely sensed chlorophyll alpha . Data of sardine stomach prey composition and CPR were obtained during 2003 for the same location off the west coast of Portugal, an area characterised by strong seasonality of plankton abundance and composition, mainly governed by upwelling events. Phyto- and zooplankton prey in sardine stomachs were identified to the lowest possible taxa and their numerical and volumetric abundance was registered, as well as their contribution to the prey carbon content. The seasonal variation of the abundance and composition of sardine diet was then compared to the abundance and composition of the water plankton obtained with the CPR at the same time and for the same area where the fish were collected, in order to evaluate if CPR data can be used to proxy sardine prey availability and diet composition at large temporal scales.
Resumo:
In this work activated dolomite adsorption was investigated for removal of acidic gaseous pollutants. Charring was found to be an effective method for the activation of dolomite. This thermal processing resulted in partial decomposition, yielding a calcite and magnesium oxide structure. Adsorbents were produced over a range of char temperatures (750, 800 and 850 °C) and char times (1–8 h). The surface properties and the adsorption capability of raw and thermally treated dolomite sorbents were investigated using porosimetry, SEM and XRD. The sorbates individually investigated were CO2 and NO2. Volumetric equilibrium isotherm determinations were produced in order to quantify sorbate capacity on the various sorbents. The equilibrium data were successfully described using the Freundlich isotherm model. Despite relatively low surface area characteristics of the activated dolomite, there was a high capacity for the acidic gas sorbates investigated, showing a maximum of 12.6 mmol/g (554 mg/g) for CO2 adsorption and 9.93 mmol/g (457 mg/g) for NO2 adsorption. Potentially the most cost effective result from the work concerns the adsorptive capacity for the naturally occurring material, which gave a capacity of 9.71 mmol/g (427 mg/g) for CO2 adsorption and 4.18 mmol/g (193 mg/g) for NO2 adsorption. These results indicate that dolomitic sorbents are potentially cost effective materials for acidic gases adsorption.
Resumo:
The results of PVT measurements of the liquid phase within the temperature range of (298 to 393) K and up to 35 MPa are presented for some aliphatic esters. Measurements were made by means of a vibrating-tube densimeter, model DMA 512P from Anton Parr. The calibration of the densimeter was performed with water and n-heptane as reference fluids. The experimental PVT data have been correlated by a Tait equation. This equation gives excellent results when used to predict the density of the esters using the method proposed by Thomson et al. (AIChE J. 1982, 28, 671-676). Isothermal compressibilities, isobaric expansivities, thermal pressure coefficients, and changes in the isobaric heat capacity have been calculated from the volumetric data.