964 resultados para Very high frequency
Resumo:
Selenium (Se) intake is generally from food, whose Se content depends on soil Se and plant accumulation. For humans, adequate Se intake is essential for several selenoenzymes. In the Lower Tapajos region of the Brazilian Amazon, Se status is elevated with large inter-community variability. Se intake in this region, where Hg exposure is among the highest in the world, may be important to counteract mercury (Hg) toxicity. The present study was conducted in 2006 with 155 persons from four communities of the Lower Tapajos. The objectives were: i) to evaluate Se content in their typical diet and drinking water; ii) to compare food Se concentrations with respect to geographic location; and iii) to examine the contribution of consumption of different food items to blood Se. More than 400 local foods and 40 drinking water samples were collected. Participants responded to an interview-administered food frequency questionnaire and provided blood samples. Food, water and blood Se levels were assessed by ICP-MS. Since Brazil nuts may also contain significant levels of barium (Ba) and strontium (Sr), these elements were likewise analyzed in nuts. The highest Se concentrations were found in Brazil nuts, but concentrations were highly variable (median: 13.9 mu g/g; range: 0.4-158.4 mu g/g). Chicken, game meat, eggs and beef also contained considerable levels of Se, with median concentrations from 0.3 to 1.4 mu g/g. There was no particular geographic distribution of food Se. Se concentration in drinking water was very low (<1.4 mu g/L). Blood Se covered a (103-1500 mu g/L), and was positively related to regular consumption of Brazil nuts, domestic chicken and game meat. Brazil nuts were found to contain highly variable and often very high concentrations of Ba (88.0 mu g/g, 1.9-1437 mu g/g) and Sr (38.7 mu g/g, 3.3-173 mu g/g). Further studies should address multiple nutrient/toxic interactions in the diet and related effects on health. (c) 2010 Elsevier B.V. All rights reserved.
Resumo:
This paper presents an analysis of dysfluencies in two oral tellings of a familiar children's story by a young boy with autism. Thurber & Tager-Flusberg (1993) postulate a lower degree of cognitive and communicative investment to explain a lower frequency of non-grammatical pauses observed in elicited narratives of children with autism in comparison to typically developing and intellectually disabled controls. we also found a very low frequency of non-grammatical pauses in our data, but indications of high engagement and cognitive and communicative investment. We point to a wider range of disfluencies as indicators of cognitive load, and show that the kind and location of dysfluencies produced may reveal which aspects of the narrative task are creating the greatest cognitive demand: here, mental state ascription, perspectivization, and adherence to story schema. This paper thus generates analytical options and hypotheses that can be explored further in a larger population of children with autism and typically developing controls.
Resumo:
We report complex ac magnetic susceptibility measurements of a superconducting transition in very high-quality single-crystal alpha-uranium using microfabricated coplanar magnetometers. We identify an onset of superconductivity at Tapproximate to0.7 K in both the real and imaginary components of the susceptibility which is confirmed by resistivity data. A superconducting volume fraction argument, based on a comparison with a calibration YBa2Cu3O7-delta sample, indicates that superconductivity in these samples may be filamentary. Our data also demonstrate the sensitivity of the coplanar micro-magnetometers, which are ideally suited to measurements in pulsed magnetic fields exceeding 100 T.
Resumo:
This paper reviews evidence on two hypotheses about the relationship between cannabis use and psychosis. The first hypothesis is that heavy cannabis use may cause a cannabis psychosis-a psychosis that would not occur in the absence of cannabis use, the symptoms of which are preceded by heavy cannabis use and remit after abstinence. The second hypothesis is that cannabis use may precipitate schizophrenia, or exacerbate its symptoms. Evaluation of these hypotheses requires evidence of an association between cannabis use and psychosis, that is unlikely to be due to chance, in which cannabis use precedes psychosis, and in which we can exclude the hypothesis that the relationship is due to other factors, such as other drug use, or a personal vulnerability to psychosis. There is some clinical support for the first hypothesis. If these disorders exist they seem to be rare, because they require very high doses of THC, the prolonged use of highly potent forms of cannabis, or a pre-existing (but as yet unspecified) vulnerability. There is more support for the second hypothesis, in that a large prospective study has shown a linear relationship between the frequency with which cannabis has been used by age 18 and the risks over the subsequent 15 years of a diagnosis of schizophrenia. It is still unclear whether this means that cannabis use precipitates schizophrenia, whether it is a form of self-medication, or whether the association is due to the use of other drugs, such as amphetamines, which heavy cannabis users are more Likely to use. There is stronger evidence that cannabis use can exacerbate the symptoms of schizophrenia. Mental health services should identify patients with schizophrenia who use alcohol, cannabis and other drugs and advise them to abstain or to greatly reduce their drug use.
Resumo:
Objective: This paper evaluates evidence for two hypotheses about the relationship between cannabis use and psychosis: (i) that heavy cannabis use causes a 'cannabis psychosis', i.e, a psychotic disorder that would not have occurred in the absence of cannabis use and which can be recognised by its pattern of symptoms and their relationship to cannabis use; and (ii) that cannabis use may precipitate schizophrenia, or exacerbate its symptoms. Method: Literature relevant to drug use and schizophrenia is reviewed. Results: There is limited clinical evidence for the first hypothesis. If 'cannabis psychoses' exist, they seem to be rare, because they require very high doses of tetrahydrocannabinol, the prolonged use of highly potent forms of cannabis, or a preexisting (but as yet unspecified) vulnerability, or both. There is more support for the second hypothesis in that a large prospective study has shown a linear relationship between the frequency with which cannabis had been used by age 18 and the risk over the subsequent 15 years of receiving a diagnosis of schizophrenia. Conclusions: It is still unclear whether this means that cannabis use precipitates schizophrenia, whether cannabis use is a form of 'self-medication', or whether the association is due to the use of other drugs, such as amphetamines, which heavy cannabis users are more likely to use. There is better clinical and epidemiological evidence that cannabis use can exacerbate the symptoms of schizophrenia.
Resumo:
In this article we report on progress in high magnetic field MRI at the University of Florida in support of our new 750MHz wide bore and 11.7T/40cm MR instruments. The primary emphasis is on the associated rf technology required, particularly high frequency volume and phased array coils. Preliminary imaging results at 750MHz are presented. Our results imply that the pursuit of even higher fields seems warranted. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
Restricted cochlear lesions in adult animals result in plastic changes in the representation of the lesioned cochlea, and thus in the frequency map, in the contralateral auditory cortex and thalamus. To examine the contribution of subthalamic changes to this reorganization, the effects of unilateral mechanical cochlear lesions on the frequency organization of the central nucleus of the inferior colliculus (ICC) were examined in adult cats. Lesions typically resulted in a broad high-frequency hearing loss extending from a frequency in the range 15-22 kHz. After recovery periods of 2.5-18 months, the frequency organization of ICC contralateral to the lesioned cochlea was determined separately for the onset and late components of multiunit responses to tone-burst stimuli. For the late response component in all but one penetration through the ICC, and for the onset response component in more than half of the penetrations, changes in frequency organization in the lesion projection zone were explicable as the residue of prelesion responses. In half of the penetrations exhibiting nonresidue type changes in onset-response frequency organization, the changes appeared to reflect the unmasking of normally inhibited inputs. In the other half it was unclear whether the changes reflected unmasking or a dynamic process of reorganization. Thus, most of the observed changes were explicable as passive consequences of the lesion, and there was limited evidence for plasticity in the ICC. The implications of the data with respect to the primary locus of the changes and to the manner in which they contribute to thalamocortical reorganization are considered. (C) 2003 Wiley-Liss, Inc.
Resumo:
This paper reports for the first time superior electric double layer capacitive properties of ordered mesoporous carbon (OMCs) with varying ordered pore symmetries and mesopore structure. Compared to commercially used activated carbon electrode, Maxsorb, these OMC carbons have superior capacitive behavior, power output and high-frequency performance in EDLCs due to the unique structure of their mesopore network, which is more favorable for fast ionic transport than the pore networks in disordered microporous carbons. As evidenced by N-2 sorption, cyclic voltammetry and frequency response measurements, OMC carbons with large mesopores, and especially with 2-D pore symmetry, show superior capacitive behaviors (exhibiting a high capacitance of over 180 F/g even at very high sweep rate of 50 mV/s, as compared to much reduced capacitance of 73 F/g for Maxsorb at the same sweep rate). OMC carbons can provide much higher power density while still maintaining good energy density. OMC carbons demonstrate excellent high-frequency performances due to its higher surface area in pores larger than 3 nm. Such ordered mesoporous carbons (OMCs) offer a great potential in EDLC capacitors, particularly for applications where high power output and good high-frequency capacitive performances are required. (C) 2005 Elsevier Ltd. All rights reserved.
Resumo:
In order to separate the effects of experience from other characteristics of word frequency (e.g., orthographic distinctiveness), computer science and psychology students rated their experience with computer science technical items and nontechnical items from a wide range of word frequencies prior to being tested for recognition memory of the rated items. For nontechnical items, there was a curvilinear relationship between recognition accuracy and word frequency for both groups of students. The usual superiority of low-frequency words was demonstrated and high-frequency words were recognized least well. For technical items, a similar curvilinear relationship was evident for the psychology students, but for the computer science students, recognition accuracy was inversely related to word frequency. The ratings data showed that subjective experience rather than background word frequency was the better predictor of recognition accuracy.
Resumo:
Background Recent studies support an important role for human papillomavirus (HPV) in a subgroup of head and neck squamous cell carcinomas (HNSCC). We have evaluated the HPV deoxyribonucleic acid (DNA) prevalence as well as the association between serological response to HPV infection and HNSCC in two distinct populations from Central Europe (CE) and Latin America (LA). Methods Cases (n = 2214) and controls (n = 3319) were recruited from 1998 to 2003, using a similar protocol including questionnaire and blood sample collection. Tumour DNA from 196 fresh tissue biopsies was analysed for multiple HPV types followed by an HPV type-specific polymerase chain reaction (PCR) protocol towards the E7 gene from HPV 16. Using multiplex serology, serum samples were analysed for antibodies to 17 HPV types. Statistical analysis included the estimation of adjusted odds ratios (ORs) and the respective 95% confidence intervals (CIs). Results HPV16 E7 DNA prevalence among cases was 3.1% (6/196), including 4.4% in the oropharynx (3/68), 3.8% in the hypopharynx/larynx (3/78) and 0% among 50 cases of oral cavity carcinomas. Positivity for both HPV16 E6 and E7 antibodies was associated with a very high risk of oropharyngeal cancer (OR = 179, 95% CI 35.8-899) and hypopharyngeal/laryngeal cancer (OR = 14.9, 95% CI 2.92-76.1). Conclusions A very low prevalence of HPV DNA and serum antibodies was observed among cases in both CE and LA. The proportion of head and neck cancer caused by HPV may vary substantially between different geographical regions and studies that are designed to evaluate the impact of HPV vaccination on HNSCC need to consider this heterogeneity.
Resumo:
Background: The relation between left ventricular filing velocities determined by Doppler echocardiography and autonomic nervous system function assessed by heart rate variability (HRV) is unclear. The aim of this study was to evaluate the influence of the autonomic nervous system assessed by the time and frequency domain indices of HRV in the Doppler indices of left ventricular diastolic filling velocities in patients without heart disease. Methods: We studied 451 healthy individuals (255 female [56.4%]) with normal blood pressure, electrocardiogram, chest x-ray, and treadmill electrocardiographic exercise stress test results, with a mean age of 43 +/- 12 (range 15-82) years, who underwent transthoracic Doppler echocardiography and 24-hour electrocardiographic ambulatory monitoring. We studied indices of HRV on time (standard deviation [SD] of all normal sinus RR intervals during 24 hours, SD of averaged normal sinus RR intervals for all 5-minute segments, mean of the SD of all normal sinus RR intervals for all 5-minute segments, root-mean-square of the successive normal sinus RR interval difference, and percentage of successive normal sinus RR intervals > 50 ms) and frequency (low frequency, high frequency, very low frequency, low frequency/high frequency ratio) domains relative to peak flow velocity during rapid passive filling phase (E), atrial contraction (A), E/A ratio, E-wave deceleration time, and isovolumic relaxation time. Statistical analysis was performed with Pearson correlation and logistic regression. Results: Peak flow velocity during rapid passive filling phase (E) and atrial contraction (A), E/A ratio, and deceleration time of early mitral inflow did not demonstrate a significant correlation with indices of HRV in time and frequency domain. We found that the E/A ratio was < 1 in 45 individuals (10%). Individuals with an E/A ratio < 1 had lower indices of HRV in frequency domain (except low frequency/high frequency) and lower indices of the mean of the SD of all normal sinus RR intervals for all 5-minute segments, root-mean-square of the successive normal sinus RR interval difference, and percentage of successive normal sinus RR intervals > 50 ms in time domain. Logistic regression demonstrated that an E/A ratio < 1 was associated with lower HF. Conclusion: Individuals with no evidence of heart disease and an E/A ratio < 1 demonstrated a significant decrease in indexes of HRV associated with parasympathetic modulation. (J Am Soc Echocardiogr 2010;23: 762-5.)
Resumo:
Objectives: (1) To establish test performance measures for Transient Evoked Otoacoustic Emission testing of 6-year-old children in a school setting; (2) To investigate whether Transient Evoked Otoacoustic Emission testing provides a more accurate and effective alternative to a pure tone screening plus tympanometry protocol. Methods: Pure tone screening, tympanometry and transient evoked otoacoustic emission data were collected from 940 subjects (1880 ears), with a mean age of 6.2 years. Subjects were tested in non-sound-treated rooms within 22 schools. Receiver operating characteristics curves along with specificity, sensitivity, accuracy and efficiency values were determined for a variety of transient evoked otoacoustic emission/pure tone screening/tympanometry comparisons. Results: The Transient Evoked Otoacoustic Emission failure rate for the group was 20.3%. The failure rate for pure tone screening was found to be 8.9%, whilst 18.6% of subjects failed a protocol consisting of combined pure tone screening and tympanometry results. In essence, findings from the comparison of overall Transient Evoked Otoacoustic Emission pass/fail with overall pure tone screening pass/fail suggested that use of a modified Rhode Island Hearing Assessment Project criterion would result in a very high probability that a child with a pass result has normal hearing (true negative). However, the hit rate was only moderate. Selection of a signal-to-noise ratio (SNR) criterion set at greater than or equal to 1 dB appeared to provide the best test performance measures for the range of SNR values investigated. Test performance measures generally declined when tympanometry results were included, with the exception of lower false alarm rates and higher positive predictive values. The exclusion of low frequency data from the Transient Evoked Otoacoustic Emission SNR versus pure tone screening analysis resulted in improved performance measures. Conclusions: The present study poses several implications for the clinical implementation of Transient Evoked Otoacoustic Emission screening for entry level school children. Transient Evoked Otoacoustic Emission pass/fail criteria will require revision. The findings of the current investigation offer support to the possible replacement of pure tone screening with Transient Evoked Otoacoustic Emission testing for 6-year-old children. However, they do not suggest the replacement of the pure tone screening plus tympanometry battery. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
Resumo:
The numerical implementation of the complex image approach for the Green's function of a mixed-potential integralequation formulation is examined and is found to be limited to low values of k(0) rho (in this context k(0) rho = 2 pirho/ lambda(0), where rho is the distance between the source and the field points of the Green's function and lambda(0) is the free space wavelength). This is a clear limitation for problems of large dimension or high frequency where this limit is easily exceeded. This paper examines the various strategies and proposes a hybrid method whereby most of the above problems can be avoided. An efficient integral method that is valid for large k(0) rho is combined with the complex image method in order to take advantage of the relative merits of both schemes. It is found that a wide overlapping region exists between the two techniques allowing a very efficient and consistent approach for accurately calculating the Green's functions. In this paper, the method developed for the computation of the Green's function is used for planar structures containing both lossless and lossy media.
Resumo:
Numerical modeling of the eddy currents induced in the human body by the pulsed field gradients in MRI presents a difficult computational problem. It requires an efficient and accurate computational method for high spatial resolution analyses with a relatively low input frequency. In this article, a new technique is described which allows the finite difference time domain (FDTD) method to be efficiently applied over a very large frequency range, including low frequencies. This is not the case in conventional FDTD-based methods. A method of implementing streamline gradients in FDTD is presented, as well as comparative analyses which show that the correct source injection in the FDTD simulation plays a crucial rule in obtaining accurate solutions. In particular, making use of the derivative of the input source waveform is shown to provide distinct benefits in accuracy over direct source injection. In the method, no alterations to the properties of either the source or the transmission media are required. The method is essentially frequency independent and the source injection method has been verified against examples with analytical solutions. Results are presented showing the spatial distribution of gradient-induced electric fields and eddy currents in a complete body model.
Resumo:
In modern magnetic resonance imaging (MRI), patients are exposed to strong, nonuniform static magnetic fields outside the central imaging region, in which the movement of the body may be able to induce electric currents in tissues which could be possibly harmful. This paper presents theoretical investigations into the spatial distribution of induced electric fields and currents in the patient when moving into the MRI scanner and also for head motion at various positions in the magnet. The numerical calculations are based on an efficient, quasi-static, finite-difference scheme and an anatomically realistic, full-body, male model. 3D field profiles from an actively shielded 4T magnet system are used and the body model projected through the field profile with a range of velocities. The simulation shows that it possible to induce electric fields/currents near the level of physiological significance under some circumstances and provides insight into the spatial characteristics of the induced fields. The results are extrapolated to very high field strengths and tabulated data shows the expected induced currents and fields with both movement velocity and field strength. (C) 2003 Elsevier Science (USA). All rights reserved.