921 resultados para Ultrasound computed tomography


Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this study, 14 post mortem equine metacarpal bones were evaluated to correlate the medial III metacarpus perimeter to dorsal bone density of the same region using Computed Tomography and Quantitative Ultrasound (QUS). According to Pearson's test, there were not correlations between these variables. Considering there are few bone densitometry studies in horses and there are many variables that can interfere with bone mineralization, new studies on equine bone density applying standard variables are recommended.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The mature dentinoenamel junction (DEJ) is viewed by some investigators and the current authors, not as a fossilized, sharp transition between enamel and dentin, but as a relatively broad structural transition zone including the mantle dentin and the inner aprismatic enamel. In this study, the DEJ structure in bovine incisors was studied with synchrotron microComputed Tomography (microCT) using small cubes cut parallel to the tooth surface. The reconstructions revealed a zone of highly variable punctate contrast between bulk dentin and enamel; the mean linear attenuation coefficients and their standard deviations demonstrated that this zone averaged less mineral than dentin or enamel but had more highly variable structure than either. The region with the punctuate contrast is, therefore, the mantle dentin. The thickness of the mantle dentin seen in a typical data set was about 30 mu m, and the mantle dentin-enamel interface deviated +/- 15 mu m from the average plane over a distance of 520 mu m. In the highest resolution data (similar to 1.5 mu m isotropic voxels, volume elements), tubules in the dentin could be discerned in the vicinity of the DEJ. Contrast sensitivity was high enough to detect differences in mineral content between near-surface and near-DEJ volumes of the enamel. Reconstructions before and after two cubes were compressed to failure revealed cracks formed only in the enamel and did not propagate across the mantle dentin, regardless of whether loading was parallel to or perpendicular to the DEJ. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background. Intravenous injection of contrast material is routinely performed in order to differentiate nonaerated lung parenchyma from pleural effusion in critically ill patients undergoing thoracic computed tomography (CT). The aim of the present study was to evaluate the effects of contrast material on CT measurement of lung volumes in 14 patients with acute lung injury. Method. A spiral thoracic CT scan, consisting of contiguous axial sections of 10 mm thickness, was performed from the apex to the diaphragm at end-expiration both before and 30 s (group 1; n=7) or 15 min (group 2; n=7) after injection of 80 ml contrast material. Volumes of gas and tissue, and volumic distribution of CT attenuations were measured before and after injection using specially designed software (Lungview®; Institut National des Télécommunications, Evry, France). The maximal artifactual increase in lung tissue resulting from a hypothetical leakage within the lung of the 80 ml contrast material was calculated. Results. Injection of contrast material significantly increased the apparent volume of lung tissue by 83 ± 57 ml in group 1 and 102 ± 80 ml in group 2, whereas the corresponding maximal artifactual increases in lung tissue were 42 ± 52 ml and 31 ± 18 ml. Conclusion. Because systematic injection of contrast material increases the amount of extravascular lung water in patients with acute lung injury, it seems prudent to avoid this procedure in critically ill patients undergoing a thoracic CT scan and to reserve its use for specific indications.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Deep venous thrombosis is a relatively common disease, which can present pulmonary embolism as a complication in its acute phase, and later the post-thrombotic syndrome. Thus, diagnosis should be made as soon as possible, in order to prevent or minimize such complications. Several studies have shown that the symptoms and the clinical signs are inaccurate for the deep venous thrombosis diagnosis and that complementary exams are necessary. As an attempt to simplify the patients' assessment, Well et al., in 1997, developed a clinical prediction index that combines symptoms, signs and risk factors for deep venous thrombosis and managed to make a simpler approach through an association of this index with the complementary exams. Phlebography has been considered the gold standard of complementary exams. However, since it is an invasive exam and thus subject to complications, other diagnostic methods were introduced aiming at making the diagnostic approach simpler and less invasive. Doppler ultrasound, duplex scan, impedance plethysmography, computed tomography, and blood tests such as the D-dimer are some of the available methods for assessing the patient with suspicion of deep venous thrombosis. Among them, duplex scan has shown excellent accuracy and it is currently widely accepted as the first choice test for approaching the patient with deep venous thrombosis. Several authors have suggested an association of diagnostic methods to simplify and make the assessment of such patients more cost-effective, leading to the introduction of a wide range of diagnostic strategies. The different diagnostic methods used for assessing deep venous thrombosis are discussed, as well as a review of the literature on the accuracy, advantages and disadvantages of these methods. Copyright © 2005 by Sociedade Brasileira de Angiologia e Cirurgia Vascular.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe the development of a low cost micro-CT X-ray scanner that is being developed for nondestructive testing. This tomograph operates using a microfocus X-ray source and contains a silicon photodiode as detectors. The performance of the system, by its spatial resolution, has been estimated through its Modulation Transfer Function - MTF and the obtained value at 10% of MTF is 661 μm. It was built as a general purpose nondestructive testing device. © 2009 American Institute of Physics.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe a non-conventional application of computerized tomography: visualization and improvements in the understanding of some internal structural features of solid dosage forms. A micro-CT X-ray scanner, with a minimum resolution of 30 μm was used to characterize some pharmaceutical tablets, granules, controlled-release osmotic tablet and liquid-filled soft-gelatin capsules. The analysis presented in this work are essentially qualitative, but quantitative parameters, such as porosity, density distribution, tablets dimensions, etc. could also be obtained using the related CT techniques. © 2010 American Institute of Physics.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this report, we present a case of myositis ossificans traumatica (MOT) of the medial pterygoid muscle that had developed after mandibular block anesthesia administered for endodontic treatment of the lower right second molar, demonstrating typical features of this condition. MOT should be considered as a differential diagnosis when there is severe limitation of jaw opening and an associated trauma. Panoramic radiographs and axial and coronal computed tomography (CT) scans can effectively delineate the calcified mass. Other imaging studies that may be helpful include magnetic resonance imaging (MRI), bone scans, and ultrasound. As shown in our case, calcified masses were found in the right mandibular angle, which severely limited jaw opening. Some earlier reported cases of MOT were treated by extraoral surgical approaches with complete removal of the evolving muscle. The aim of this case report is to present only the diagnostic imaging aspects of myositis ossificans traumatica.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this paper was to report the diagnosis and evaluation of periradicular bone repair by using computed tomography and digital subtraction radiography in an endodontic surgery case treated with mineral trioxide aggregate (MTA). The patient had local swelling and fistula 7years after trauma in the upper jaw. Periapical lesion on tooth #12 and root resorption of tooth #11 were detected radiographically. Endodontic therapy and placement of intracanal medication were carried out. After 3months, with no improvement in the clinical signs and symptoms, computed tomography was performed, showing extensive apical bone resorption on tooth #12 and dental resorption promoting communication of the root canal with the periodontium of tooth #11. The patient was referred to endodontic surgery. After surgery and postoperative periods of 15, 30, 60, 90, and 120days, standardized radiographs were taken, digitized, and subjected to digital subtraction of the images using Adobe Photoshop CS software. Four years later, a cone-beam computed tomography was performed, showing bone repair and absence of root resorption at tooth #11. In this clinical case, digital subtraction radiography was effective for early detection of new bone formation and evolution of repair. © 2011 John Wiley & Sons A/S.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to retrospectively evaluate in the casuistry on class and systems frequently diagnosed in wild animals that were sent to the FMVZ-UNESP-Botucatu diagnostic imaging service. The class of birds was the most referred to the centers, followed by the mammals and reptiles. The majority of the requested tests were the radiographs and in a minor scale the tomography and ultrasound. Although the birds were the greatest number of animals sent to the service, mammals were the most radiographed for wound control. The most frequently observed system was the musculoskeletal caused by trauma, especially in birds. The radiograph was the most exam initially indicated, then the animal could be forwarded to other imaging modalities, which in wild animals medicine is still limited to research.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The SPECT (Single Photon Emission Computed Tomography) systems are part of a medical image acquisition technology which has been outstanding, because the resultant images are functional images complementary to those that give anatomic information, such as X-Ray CT, presenting a high diagnostic value. These equipments acquire, in a non-invasive way, images from the interior of the human body through tomographic mapping of radioactive material administered to the patient. The SPECT systems are based on the Gamma Camera detection system, and one of them being set on a rotational gantry is enough to obtain the necessary data for a tomographic image. The images obtained from the SPECT system consist in a group of flat images that describe the radioactive distribution on the patient. The trans-axial cuts are obtained from the tomographic reconstruction techniques. There are analytic and iterative methods to obtain the tomographic reconstruction. The analytic methods are based on the Fourier Cut Theorem (FCT), while the iterative methods search for numeric solutions to solve the equations from the projections. Within the analytic methods, the filtered backprojection (FBP) method maybe is the simplest of all the tomographic reconstruction techniques. This paper's goal is to present the operation of the SPECT system, the Gamma Camera detection system, some tomographic reconstruction techniques and the requisites for the implementation of this system in a Nuclear Medicine service

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Imaging diagnosis is a medical specialty that uses imaging techniques to perform diagnosis. In diagnostic imaging various methods are used such as direct absorption of photons - SPA and DPA, radiographic photometry, the dual-energy radiographic absorptiometry - DEXA, ultrasound, magnetic resonance imaging, computed tomography and optical densitometry in radiographic image. The dog can be considered one of the most widely used animals in the study of bone diseases and searching for a reliable diagnosis, although not an ideal model for the study of osteoporosis, because these animals tend not to develop a decrease in bone mineral density. The objective of this study was to analyze bone density in mongrel dogs from the determination of the variation of density along the radio-ulna bone and also the mean value related to gender, weight and age of individuals. The density analysis carried out showed that for this data set, there is a significant difference in the case of gender and age of the animal and may generalize according to these variables. The only significant difference was found in the weight, which increases bone mass is related to weight gain through the growth of the animal