690 resultados para Tomographic Scintigraphy
Resumo:
This work present the application of a computer package for generating of projection data for neutron computerized tomography, and in second part, discusses an application of neutron tomography, using the projection data obtained by Monte Carlo technique, for the detection and localization of light materials such as those containing hydrogen, concealed by heavy materials such as iron and lead. For tomographic reconstructions of the samples simulated use was made of only six equal projection angles distributed between 0º and 180º, with reconstruction making use of an algorithm (ARIEM), based on the principle of maximum entropy. With the neutron tomography it was possible to detect and locate polyethylene and water hidden by lead and iron (with 1cm-thick). Thus, it is demonstrated that thermal neutrons tomography is a viable test method which can provide important interior information about test components, so, extremely useful in routine industrial applications.
Resumo:
The histopathology of the liver is fundamental for the differential diagnosis between intra- and extrahepatic causes of neonatal cholestasis. However, histopathological findings may overlap and there is disagreement among authors concerning those which could discriminate between intra- and extrahepatic cholestasis. Forty-six liver biopsies (35 wedge biopsies and 11 percutaneous biopsies) and one specimen from a postmortem examination, all from patients hospitalized for neonatal cholestasis in the Pediatrics Service of Hospital de Clínicas de Porto Alegre, were prospectively studied using a specially designed histopathological protocol. At least 4 of 5 different stains were used, and 46 hepatic histopathological variables related to the differential diagnosis of neonatal cholestasis were studied. The findings were scored for severity on a scale from 0 to 4. Sections which showed less than 3 portal spaces were excluded from the study. Sections were examined by a pathologist who was unaware of the final diagnosis of each case. Bile tract permeability was defined by scintigraphy of the bile ducts and operative cholangiography. The F test and discriminant analysis were used as statistical methods for the study of the hepatic histopathological variables. The chi-square method with Yates correction was used to relate the age of the patients on the date of the histopathological study to the discriminatory variables between intra- and extrahepatic cholestasis selected by the discriminant function test. The most valuable hepatic histopathological variables for the discrimination between intra- and extrahepatic cholestasis, in decreasing order of importance, were periportal ductal proliferation, portal ductal proliferation, portal expansion, cholestasis in neoductules, foci of myeloid metaplasia, and portal-portal bridges. The only variable which pointed to the diagnosis of intrahepatic cholestasis was myeloid metaplasia. Due to the small number of patients who were younger than 60 days on the date of the histopathological study (N = 6), no variable discriminated between intra- and extrahepatic cholestasis before the age of 2 months and all of them, except for the portal expansion, were discriminatory after this age. In infants with cholestasis, foci of myeloid metaplasia, whenever present in the liver biopsy, suggested intrahepatic cholestasis. Periportal ductal proliferation, portal ductal proliferation, portal expansion, cholestasis in neoductules, portal cholestasis and portal-portal bridges suggested extrahepatic obstructive cholestasis.
Resumo:
Incidentally discovered adrenal masses, or adrenal incidentalomas, have become a common clinical problem owing to wide application of radiologic imaging techniques. This definition encompasses a heterogeneous spectrum of pathologic entities, including primary adrenocortical and medullary tumors, benign or malignant lesions, hormonally active or inactive lesions, metastases, and infections. Once an adrenal mass is detected, the clinician needs to address two crucial questions: is the mass malignant, and is it hormonally active? This article provides an overview of the diagnostic clinical approach and management of the adrenal incidentaloma. Mass size is the most reliable variable to distinguish benign and malignant adrenal masses. Adrenalectomy should be recommended for masses greater than 4.0 cm because of the increased risk of malignancy. Adrenal scintigraphy has proved useful in discriminating between benign and malignant lesions. Finally, fine-needle aspiration biopsy is an important tool in the evaluation of oncological patients and it may be useful in establishing the presence of metastatic disease. The majority of adrenal incidentalomas are non-hypersecretory cortical adenomas but an endocrine evaluation can lead to the identification of a significant number of cases with subclinical Cushing's syndrome (5-15%), pheochromocytoma (1.5-13%) and aldosteronoma (0-7%). The first step of hormonal screening should include an overnight low dose dexamethasone suppression test, the measure of urinary catecholamines or metanephrines, serum potassium and, in hypertensive patients, upright plasma aldosterone/plasma renin activity ratio. Dehydroepiandrosterone sulfate measurement may show evidence of adrenal androgen excess.
Resumo:
Several studies show the ability of macrophages to remove particles injected into the bloodstream. This function seems to be increased in the presence of acute renal failure. The objective of the present study was to assess the phagocytic function of the main organs (spleen, liver and lung) of the mononuclear phagocytic system in renal and postrenal failures. Fifteen rats (250-350 g) were divided into three groups (N = 5): group I - control; group II - ligature of both ureters, and group III - bilateral nephrectomy. On the third postoperative day, all animals received an iv injection of 1 ml/kg 99mTc sulfur colloid. Blood samples were collected for the assessment of plasma urea, creatinine, sodium, and potassium concentrations and arterial gasometry. Samples of liver, spleen, lung and blood clots were obtained and radioactivity was measured. Samples of liver, spleen, lung and kidney were prepared for routine histopathological analysis. Plasma urea, creatinine and potassium concentrations in groups II and III were higher than in group I (P<0.05). Plasma sodium concentrations in groups II and III were lower than in group I (P<0.05). Compensated metabolic acidosis was observed in the presence of postrenal failure. Group II animals showed a lower level of radioactivity in the spleen (0.98) and lung (2.63), and a higher level in the liver (105.51) than control. Group III animals showed a lower level of radioactivity in the spleen (11.94) and a higher level in the liver (61.80), lung (11.30) and blood clot (5.13) than control. In groups II and III liver steatosis and bronchopneumonia were observed. Renal and postrenal failures seem to interfere with blood clearance by the mononuclear phagocytic system.
Resumo:
The early demonstration of lung involvement in systemic lupus erythematosus (SLE) patients is a difficult but important task. In the present study we attempted to identify abnormalities in pulmonary clearance of 99mTc-DTPA in SLE, correlating their clearance data with clinical findings and disease activity. Forty-six consecutive SLE patients with and without active disease (LACC score) and 30 normal volunteers were studied. All subjects were submitted to pulmonary scintigraphy with 99mTc-DTPA to evaluate the pulmonary clearance, and to a chest X-ray, and SLE patients were submitted to tests of disease activity, spirometry, arterial blood gases and tests to assess acute-phase proteins. Pulmonary clearance was faster in SLE patients with active disease when compared to normal controls [half-life of 67.04 min (51.52-82.55 min) in active SLE versus 85.87 min (78.85-92.87 min) in controls, P<0.05] and there was a higher frequency of abnormal clearance rates in patients with active disease (11 of 26 patients, 42.3%) when compared with SLE patients without disease activity (2 of 20 patients, 10%) (P = 0.04). A significant correlation was observed between the clearance rates and cough (P<0.05), but not between the clearance rates and dyspnea symptoms or radiological findings, duration of SLE disease, antinuclear antibody titers and patterns, C-reactive protein or anti-double stranded DNA antibodies. We conclude that the pulmonary clearance of 99mTc-DTPA is increased in SLE patients with active disease.
Resumo:
The objective of the present study was to assess esophageal motor function in 21 children (7.5 ± 2.9 years) with caustic strictures. Esophageal manometry was performed using a water-infusion system interfaced with a polygraph and displayed on a computer screen. The data were compared with those obtained from 9 healthy children. Radionuclide transit was determined by studying deglutition of a single bolus of 99mTc pertechnetate in 10 ml of water. Non-peristaltic low-amplitude and long-duration waves were the most common findings detected in patients with strictures longer than 20% of esophageal length (N = 11). Compared with the control group, these patients presented lower mean amplitude and longer mean duration of waves (24.4 ± 11.2 vs 97.9 ± 23.7 mmHg, P < 0.05, and 6.7 ± 2.4 vs 1.6 ± 0.1 s, P < 0.05, respectively). Six patients presented low-amplitude waves just below the constricted site. Ten children presented delayed esophageal transit. There was an association between dysphagia and abnormalities on manometry (P = 0.02) and between symptoms and scintigraphy data (P = 0.01). Dysphagia in caustic strictures is due to esophageal motility abnormalities, which are closely related to the scarred segment.
Resumo:
Sildenafil slows down the gastric emptying of a liquid test meal in awake rats and inhibits the contractility of intestinal tissue strips. We studied the acute effects of sildenafil on in vivo intestinal transit in rats. Fasted, male albino rats (180-220 g, N = 44) were treated (0.2 mL, iv) with sildenafil (4 mg/kg) or vehicle (0.01 N HCl). Ten minutes later they were fed a liquid test meal (99m technetium-labeled saline) injected directly into the duodenum. Twenty, 30 or 40 min after feeding, the rats were killed and transit throughout the gastrointestinal tract was evaluated by progression of the radiotracer using the geometric center method. The effect of sildenafil on mean arterial pressure (MAP) was monitored in a separate group of rats (N = 14). Data (medians within interquartile ranges) were compared by the Mann-Whitney U-test. The location of the geometric center was significantly more distal in vehicle-treated than in sildenafil-treated rats at 20, 30, and 40 min after test meal instillation (3.3 (3.0-3.6) vs 2.9 (2.7-3.1); 3.8 (3.4-4.0) vs 2.9 (2.5-3.1), and 4.3 (3.9-4.5) vs 3.4 (3.2-3.7), respectively; P < 0.05). MAP was unchanged in vehicle-treated rats but decreased by 25% (P < 0.05) within 10 min after sildenafil injection. In conclusion, besides transiently decreasing MAP, sildenafil delays the intestinal transit of a liquid test meal in awake rats.
Resumo:
Single-photon emission computed tomography (SPECT) is a non-invasive imaging technique, which provides information reporting the functional states of tissues. SPECT imaging has been used as a diagnostic tool in several human disorders and can be used in animal models of diseases for physiopathological, genomic and drug discovery studies. However, most of the experimental models used in research involve rodents, which are at least one order of magnitude smaller in linear dimensions than man. Consequently, images of targets obtained with conventional gamma-cameras and collimators have poor spatial resolution and statistical quality. We review the methodological approaches developed in recent years in order to obtain images of small targets with good spatial resolution and sensitivity. Multipinhole, coded mask- and slit-based collimators are presented as alternative approaches to improve image quality. In combination with appropriate decoding algorithms, these collimators permit a significant reduction of the time needed to register the projections used to make 3-D representations of the volumetric distribution of target’s radiotracers. Simultaneously, they can be used to minimize artifacts and blurring arising when single pinhole collimators are used. Representation images are presented, which illustrate the use of these collimators. We also comment on the use of coded masks to attain tomographic resolution with a single projection, as discussed by some investigators since their introduction to obtain near-field images. We conclude this review by showing that the use of appropriate hardware and software tools adapted to conventional gamma-cameras can be of great help in obtaining relevant functional information in experiments using small animals.
Resumo:
The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct the target’s three-dimensional distribution of emission from a set of planar projections, based on the maximum likelihood algorithm. We present details on the hardware and software implementation. We imaged phantoms and heart and kidneys of rats. When using pinhole collimators, the spatial resolution and sensitivity of the imaging system depend on parameters such as the detector-to-collimator and detector-to-target distances and pinhole diameter. In this study, we reached an object voxel size of 0.6 mm and spatial resolution better than 2.4 and 1.7 mm full width at half maximum when 1.5- and 1.0-mm diameter pinholes were used, respectively. Appropriate sensitivity to study the target of interest was attained in both cases. Additionally, we show that as few as 12 projections are sufficient to attain good quality reconstructions, a result that implies a significant reduction of acquisition time and opens the possibility for radiotracer dynamic studies. In conclusion, a high resolution single photon emission computed tomography (SPECT) system was developed using a commercial clinical gamma camera, allowing the acquisition of detailed volumetric images of small animal organs. This type of system has important implications for research areas such as Cardiology, Neurology or Oncology.
Resumo:
The objective of this study was to evaluate gastric emptying (GE) in pediatric patients with functional constipation. GE delay has been reported in adults with functional constipation. Gastric emptying studies were performed in 22 children with chronic constipation, fecal retention and fecal incontinence, while presenting fecal retention and after resuming regular bowel movements. Patients (18 boys, median age: 10 years; range: 7.2 to 12.7 years) were evaluated in a tertiary pediatric gastroenterology clinic. Gastric half-emptying time of water (reference range: 12 ± 3 min) was measured using a radionuclide technique immediately after first patient evaluation, when they presented fecal impaction (GE1), and when they achieved regular bowel movements (GE2), 12 ± 5 weeks after GE1. At study admission, 21 patients had reported dyspeptic symptoms, which were completely relieved after resuming regular bowel movements. Medians (and interquartile ranges) for GE1 and GE2 were not significantly different [27.0 (16) and 27.5 (21) min, respectively (P = 0.10)]. Delayed GE seems to be a common feature among children with chronic constipation and fecal retention. Resuming satisfactory bowel function and improvement in dyspeptic symptoms did not result in normalization of GE data.
Resumo:
The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD). Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s-1·MBq-1 were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging 99mTc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using 99mTc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity.
Resumo:
Optical microscopy is living its renaissance. The diffraction limit, although still physically true, plays a minor role in the achievable resolution in far-field fluorescence microscopy. Super-resolution techniques enable fluorescence microscopy at nearly molecular resolution. Modern (super-resolution) microscopy methods rely strongly on software. Software tools are needed all the way from data acquisition, data storage, image reconstruction, restoration and alignment, to quantitative image analysis and image visualization. These tools play a key role in all aspects of microscopy today – and their importance in the coming years is certainly going to increase, when microscopy little-by-little transitions from single cells into more complex and even living model systems. In this thesis, a series of bioimage informatics software tools are introduced for STED super-resolution microscopy. Tomographic reconstruction software, coupled with a novel image acquisition method STED< is shown to enable axial (3D) super-resolution imaging in a standard 2D-STED microscope. Software tools are introduced for STED super-resolution correlative imaging with transmission electron microscopes or atomic force microscopes. A novel method for automatically ranking image quality within microscope image datasets is introduced, and it is utilized to for example select the best images in a STED microscope image dataset.
Resumo:
Présentement, le diagnostic d’otite moyenne-interne chez le veau est basé sur la présence de signes cliniques appropriés ainsi que les tests diagnostiques tels que la radiographie et la tomodensitométrie. L’objectif de cette étude prospective était d’évaluer les valeurs prédictives de l’examen neurologique, l’examen otoscopique et le test des potentiels auditifs évoqués (PAE) dans le diagnostic d’otite moyenne-interne chez le veau, en utilisant la tomodensitométrie comme test standard. Le deuxième objectif était de définir les valeurs de référence pour le PAE chez le veau normal et d’en décrire les anomalies chez des veaux atteints d’otite moyenne-interne. Dix-sept veaux de race Holstein entre 5-7 semaines d’âge ont été inclus. Tous les veaux ont eu un examen neurologique, un examen otoscopique et une évaluation des PAEs. Les veaux ont été tranquillisés avec de la xylazine intraveineuse (0,05-0,15mg/kg) pour la tomodensitométrie des bulles tympaniques afin d’évaluer pour la présence d’otite moyenne-interne. Selon les résultats de la tomodensitométrie, 11 des 17 veaux étaient atteints avec otite moyenne, 4 de façon unilatérale et 7 bilatéralement. Cinq ondes ont été identifiées de façon constante sur les tracés des PAEs des 6 veaux normaux. Les valeurs positives prédictives pour le PAE, l’examen neurologique et l’examen otoscopique étaient 94,7%, 91,7% et 66,7% respectivement. D’un point de vue clinique, le test le plus fiable dans le diagnostic d’otite moyenne-interne chez le veau est le PAE. Les anomalies ont été observées au PAE avant le développement des signes neurologiques chez certains veaux.
Resumo:
This thesis was created in Word and converted to PDF using Mac OS X 10.7.5 Quartz PDFContext.
Resumo:
Les néphropaties (maladie des tissus rénaux) postradiques constituent l'un des facteurs limitants pour l'élaboration des plans de traitement lors des radiothérapies abdominales. Le processus actuel, qui consiste à évaluer la fonctionnalité relative des reins grâce à une scintigraphie gamma deux dimensions, ne permet pas d'identifier les portions fonctionnelles qui pourraient être évitées lors de l' élaboration des plans de traitement. Une méthode permettant de cartographier la fonctionnalité rénale en trois dimensions et d'extraire un contour fonctionnel utilisable lors de la planification a été développée à partir de CT double énergie injectés à l'iode. La concentration en produit de contraste est considérée reliée à la fonctionnalité rénale. La technique utilisée repose sur la décomposition à trois matériaux permettant de reconstruire des images en concentration d'iode. Un algorithme de segmentation semi-automatisé basé sur la déformation hiérarchique et anamorphique de surfaces permet ensuite d'extraire le contour fonctionnel des reins. Les premiers résultats obtenus avec des images patient démontrent qu'une utilisation en clinique est envisageable et pourra être bénéfique.