946 resultados para Time domain simulation tools
Resumo:
This paper presents the measurement, frequency-response modeling and identification, and the corresponding impulse time response of the human respiratory impedance and admittance. The investigated adult patient groups were healthy, diagnosed with chronic obstructive pulmonary disease and kyphoscoliosis, respectively. The investigated children patient groups were healthy, diagnosed with asthma and cystic fibrosis, respectively. Fractional order (FO) models are identified on the measured impedance to quantify the respiratory mechanical properties. Two methods are presented for obtaining and simulating the time-domain impulse response from FO models of the respiratory admittance: (i) the classical pole-zero interpolation proposed by Oustaloup in the early 90s, and (ii) the inverse discrete Fourier Transform (DFT). The results of the identified FO models for the respiratory admittance are presented by means of their average values for each group of patients. Consequently, the impulse time response calculated from the frequency response of the averaged FO models is given by means of the two methods mentioned above. Our results indicate that both methods provide similar impulse response data. However, we suggest that the inverse DFT is a more suitable alternative to the high order transfer functions obtained using the classical Oustaloup filter. Additionally, a power law model is fitted on the impulse response data, emphasizing the intrinsic fractal dynamics of the respiratory system.
Resumo:
This contribution presents novel concepts for analysis of pressure–volume curves, which offer information about the time domain dynamics of the respiratory system. The aim is to verify whether a mapping of the respiratory diseases can be obtained, allowing analysis of (dis)similarities between the dynamical pattern in the breathing in children. The groups investigated here are children, diagnosed as healthy, asthmatic, and cystic fibrosis. The pressure–volume curves have been measured by means of the noninvasive forced oscillation technique during breathing at rest. The geometrical fractal dimension is extracted from the pressure–volume curves and a power-law behavior is observed in the data. The power-law model coefficients are identified from the three sets and the results show that significant differences are present between the groups. This conclusion supports the idea that the respiratory system changes with disease in terms of airway geometry, tissue parameters, leading in turn to variations in the fractal dimension of the respiratory tree and its dynamics.
Resumo:
IEEE International Symposium on Circuits and Systems, pp. 724 – 727, Seattle, EUA
Resumo:
Dissertação apresentada na faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
Trabalho Final de Mestrado elaborado no Laboratório Nacional de Engenharia Civil (LNEC) para a obtenção do grau de Mestre em Engenharia Civil pelo Instituto Superior de Engenharia de Lisboa no âmbito do protocolo entre o ISEL e o LNEC
Resumo:
Electricity markets are complex environments with very particular characteristics. A critical issue concerns the constant changes they are subject to. This is a result of the electricity markets’ restructuring, performed so that the competitiveness could be increased, but with exponential implications in the increase of the complexity and unpredictability in those markets’ scope. The constant growth in markets unpredictability resulted in an amplified need for market intervenient entities in foreseeing market behavior. The need for understanding the market mechanisms and how the involved players’ interaction affects the outcomes of the markets, contributed to the growth of usage of simulation tools. Multi-agent based software is particularly well fitted to analyze dynamic and adaptive systems with complex interactions among its constituents, such as electricity markets. This paper presents the Multi-Agent System for Competitive Electricity Markets (MASCEM) – a simulator based on multi-agent technology that provides a realistic platform to simulate electricity markets, the numerous negotiation opportunities and the participating entities.
Resumo:
Uma nova tecnologia, os EDLC, também denominados por supercondensadores, tem-se tornado numa importante e aliciante área de interesse. Estes regem-se pelos mesmos princípios fundamentais dos condensadores clássicos, no entanto possibilitam receber capacidades superiores, devido a uma maior área de superfície e a um dielétrico menos espesso. Esta particularidade permite obter uma maior densidade energética, comparativamente com os condensadores clássicos e uma maior densidade de potência, comparativamente com as baterias. Consequentemente a utilização de supercondensadores tem aumentado, representando já uma alternativa fiável, segura e amiga do ambiente, em detrimento das baterias comuns. Assim, este projeto tem como principais objetivos, identificar os diferentes tipos de supercondensadores, apresentar as vantagens de cada tipo e explorar a sua resposta, quer no domínio das frequências quer no domínio dos tempos, e por fim modelá-los recorrendo a componentes elétricos clássicos, nomeadamente resistências e condensadores. A modelação foi realizada recorrendo ao MALTAB, através da função de minimização fminunc e foram construídos quatro modelos equivalentes, com o objetivo de modelar a resposta dos vários EDLC analisados. Por escassez de tempo o principal foco de análise recaiu sobre o EDLC de 0,022 F.
Resumo:
O transporte ferroviário é um meio de transporte em que o meio de deslocamento ocorre por meio de vias férreas, transportando, entre outros, pessoas e cargas. Este meio de transporte é um dos mais antigos e a sua origem está ligada directamente com a Primeira Revolução Industrial, acontecimento histórico que sucedeu na Europa no final do século XVIII e início do século XIX. Uma rede ferroviária é um sistema único no ponto de vista do uso de tração elétrica assim como no modo que se insere na sociedade por ser um meio de transporte seguro, rápido e bastante utilizado pela população. As redes de alimentação de energia (transporte e distribuição) e a rede de alta velocidade ditaram novas soluções para a alimentação elétrica ferroviária contribuindo para a sua evolução técnica, na segurança e também na compatibilidade eletromagnética no sentido de se estabelecerem critérios de controlo e prevenção dos efeitos indesejáveis provocados pela interferência magnética. O presente trabalho tem por objetivo analisar e estudar tecnicamente como se comportam as redes que alimentam os veículos de tração elétrica desde as subestações até à alimentação das locomotivas. Dada a complexidade da sua análise torna-se necessário o recurso a ferramentas de simulação mais ou menos complexas. No presente trabalho recorreu-se ao MATLABTM, nomeadamente, ao MATLABTM/Simulink. Foram analisadas as principais grandezas elétricas em cenários distintos para os sistemas de alimentação da catenária de 1x25 kV e 2x25 kV.
Resumo:
The paper revisits the convolution operator and addresses its generalization in the perspective of fractional calculus. Two examples demonstrate the feasibility of the concept using analytical expressions and the inverse Fourier transform, for real and complex orders. Two approximate calculation schemes in the time domain are also tested.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
OBJECTIVE: To analyze the heart rate variability in patients with mild to moderate systemic arterial hypertension. METHODS: Thirty-two healthy (group I) and 70 systemic arterial hypertensive (group II) individuals, divided according to age (40 to 59 and 60 to 80 years old, respectively) and with a similar distribution by sex were studied. Thirty-one had left ventricular hypertrophy (LVH), 22 were overweight, and 16 had Type II diabetes mellitus. Smoking, alcohol ingestion, and sedentary habits were the same between groups. Variability in heart rate was analyzed in the time domain, using standard deviations of normal RR intervals (SDNN) and the differences between maximal brady- and tachycardia (D-BTmax) during sustained inspiration. Analysis of the frequency band of the power spectrum between 0.05 and 0.40 Hz at rest and during controlled respiration was chosen for analysis of the frequency domain. RESULTS: In both time and frequency domains, variables were lower in group II than in group I. Within groups, statistically significant variables were only found for individuals in the 40 to 59 year old group. The presence of LVH, overweight, or diabetes mellitus did not influence the variability in heart rate to a significant extent. CONCLUSION: Variability in heart rate was a valuable instrument for analyzing autonomic modulation of the heart in arterial hypertension. The autonomic system undergoes significant losses in cardio-modulatory capacity, more evident in subjects between 40 and 59 years old. In those over 60 years old, reduced variability in heart rate imposed by aging was not significantly influenced by the presence of systemic arterial hypertension.
Resumo:
OBJECTIVE: The initial site of myocardial infarction (MI) may influence the prevalence of ventricular late potentials (VLP), high-frequency signals, due to the time course of ventricular activation. The prevalence of VLP in a period of more than 2 years after acute MI was assessed focusing on the initially injured wall . METHODS: The prevalence of VLP in a late phase after MI (median of 924 days) in anterior/antero-septal and inferior/infero-dorsal wall lesion was analyzed using signal-averaged electrocardiogram in time domain. The diagnostic performance of the filters employed for analysis on was tested at high-pass cut-off frequencies of 25 Hz, 40 Hz and 80 Hz. RESULTS: The duration of the ventricular activation and its terminal portion were larger in inferior than anterior infarction, at high-pass cut-off frequencies of 40 Hz and 80 Hz. In patients with ventricular tachycardia, these differences were more remarked. The prevalence of ventricular late potentials was three times greater in inferior than anterior infarction. CONCLUSION: Late after myocardial infarction, the prevalence and the duration of ventricular late potentials are greater in lesions of inferior/infero-dorsal than anterior/antero-septal wall confirming their temporal process, reflecting their high-frequency content.
Resumo:
OBJECTIVE: To assess signal-averaged electrocardiogram (SAECG) for diagnosing incipient left ventricular hypertrophy (LVH). METHODS: A study with 115 individuals was carried out. The individuals were divided as follows: GI - 38 healthy individuals; GII - 47 individuals with mild to moderate hypertension and normal findings on echocardiogram and ECG; and GIII - 30 individuals with hypertension and documented LVH. The magnitude vector of the SAECG was analyzed with the high-pass cutoff frequency of 40 Hz through the bidirectional four-pole Butterworth high-pass digital filter. The mean quadratic root of the total QRS voltage (RMST) and the two-dimensional integral of the QRS area of the spectro-temporal map were analyzed between 0 and 30 Hz for the frequency domain (Int FD), and between 40 and 250 Hz for the time domain (Int TD). The electrocardiographic criterion for LVH was based on the Cornell Product. Left ventricular mass was calculated with the Devereux formula. RESULTS: All parameters analyzed increased from GI to GIII, except for Int FD (GII vs GIII) and RMST log (GII vs GIII). Int TD showed greater accuracy for detecting LVH with an appropriate cutoff > 8 (sensitivity of 55%, specificity of 81%). Positive values (> 8) were found in 56.5% of the G II patients and in 18.4% of the GI patients (p< 0.0005). CONCLUSION: SAECG can be used in the early diagnosis of LVH in hypertensive patients with normal ECG and echocardiogram.
Resumo:
Background: Ivabradine is a novel specific heart rate (HR)-lowering agent that improves event-free survival in patients with heart failure (HF). Objectives: We aimed to evaluate the effect of ivabradine on time domain indices of heart rate variability (HRV) in patients with HF. Methods: Forty-eight patients with compensated HF of nonischemic origin were included. Ivabradine treatment was initiated according to the latest HF guidelines. For HRV analysis, 24-h Holter recording was obtained from each patient before and after 8 weeks of treatment with ivabradine. Results: The mean RR interval, standard deviation of all normal to normal RR intervals (SDNN), the standard deviation of 5-min mean RR intervals (SDANN), the mean of the standard deviation of all normal-to-normal RR intervals for all 5-min segments (SDNN index), the percentage of successive normal RR intervals exceeding 50 ms (pNN50), and the square root of the mean of the squares of the differences between successive normal to normal RR intervals (RMSSD) were low at baseline before treatment with ivabradine. After 8 weeks of treatment with ivabradine, the mean HR (83.6 ± 8.0 and 64.6 ± 5.8, p < 0.0001), mean RR interval (713 ± 74 and 943 ± 101 ms, p < 0.0001), SDNN (56.2 ± 15.7 and 87.9 ± 19.4 ms, p < 0.0001), SDANN (49.5 ± 14.7 and 76.4 ± 19.5 ms, p < 0.0001), SDNN index (24.7 ± 8.8 and 38.3 ± 13.1 ms, p < 0.0001), pNN50 (2.4 ± 1.6 and 3.2 ± 2.2 %, p < 0.0001), and RMSSD (13.5 ± 4.6 and 17.8 ± 5.4 ms, p < 0.0001) substantially improved, which sustained during both when awake and while asleep. Conclusion: Our findings suggest that treatment with ivabradine improves HRV in nonischemic patients with HF.