878 resultados para Surface Plasmon, Impedance Spectroscopy
Resumo:
We present measurements of morphological features in a thick turbid sample using light-scattering spectroscopy (LSS) and Fourier-domain low-coherence interferometry (fLCI) by processing with the dual-window (DW) method. A parallel frequency domain optical coherence tomography (OCT) system with a white-light source is used to image a two-layer phantom containing polystyrene beads of diameters 4.00 and 6.98 mum on the top and bottom layers, respectively. The DW method decomposes each OCT A-scan into a time-frequency distribution with simultaneously high spectral and spatial resolution. The spectral information from localized regions in the sample is used to determine scatterer structure. The results show that the two scatterer populations can be differentiated using LSS and fLCI.
Resumo:
A backside protein-surface imprinting process is presented herein as a novel way to generate specific synthetic antibody materials. The template is covalently bonded to a carboxylated-PVC supporting film previously cast on gold, let to interact with charged monomers and surrounded next by another thick polymer. This polymer is then covalently attached to a transducing element and the backside of this structure (supporting film plus template) is removed as a regular “tape”. The new sensing layer is exposed after the full template removal, showing a high density of re-binding positions, as evidenced by SEM. To ensure that the templates have been efficiently removed, this re-binding layer was cleaned further with a proteolytic enzyme and solution washout. The final material was named MAPS, as in the back-side reading of SPAM, because it acts as a back-side imprinting of this recent approach. It was able to generate, for the first time, a specific response to a complex biomolecule from a synthetic material. Non-imprinted materials (NIMs) were also produced as blank and were used as a control of the imprinting process. All chemical modifications were followed by electrochemical techniques. This was done on a supporting film and transducing element of both MAPS and NIM. Only the MAPS-based device responded to oxLDL and the sensing layer was insensitive to other serum proteins, such as myoglobin and haemoglobin. Linear behaviour between log(C, μg mL−1) versus charged tranfer resistance (RCT, Ω) was observed by electrochemical impedance spectroscopy (EIS). Calibrations made in Fetal Calf Serum (FCS) were linear from 2.5 to 12.5 μg mL−1 (RCT = 946.12 × log C + 1590.7) with an R-squared of 0.9966. Overall, these were promising results towards the design of materials acting close to the natural antibodies and applied to practical use of clinical interest.
Resumo:
A novel surface molecularly-imprinted (MI) material to detect myoglobin (Myo) using gold screen printed electrodes (SPE) was developed. The sensitive detection was carry out by introducing a carboxylic polyvinyl chloride (PVC-COOH) layer on gold SPE surface. Myo was attached to the surface of gold SPE/PVC-COOH and the vacant spaces around it were filled by polymerizing acrylamide and N,N-methylenebisacrylamide (cross-linker). This polymerization was initiated by ammonium persulphate. After removing the template, the obtained material was able to rebind Myo and discriminate it among other interfering species. Various characterization techniques including electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) confirmed the surface modification. This sensor seemed a promising tool for screening Myo in point-of-care.
Resumo:
Les biocapteurs sont utilisés quotidiennement pour déterminer la présence de molécules biologiques dans une matrice complexe, comme l’urine pour les tests de grossesses ou le sang pour les glucomètres. Les techniques courantes pour la détection des autres maladies nécessitent fréquemment le marquage de l’analyte avec une autre molécule, ce qui est à éviter pour fin de simplicité d’analyse. Ces travaux ont pour but la maximisation de la sensibilité d’une surface d’or ou d’argent nanotrouée, afin de permettre la détection de la liaison de molécules biologiques par résonance des plasmons de surface localisés (LSPR), en utilisant la spectroscopie de transmission. Un biocapteur portable, rapide et sans marquage pour quantifier des analytes d’intérêt médical ou environnemental pourrait être construit à partir de ces travaux. Dans l’objectif d’étudier de nombreuses configurations pour maximiser la sensibilité, le temps et le coût des méthodes de fabrication de nanostructures habituelles auraient limité le nombre de surfaces nanotrouées pouvant être étudiées. Un autre objectif du projet consiste donc au développement d’une technique de fabrication rapide de réseaux de nanotrous, et à moindres coûts, basée sur la lithographie de nanosphères (NSL) et sur la gravure au plasma à l’oxygène (RIE). La sensibilité à la variation d’indice de réfraction associée aux liaisons de molécules sur la surface du métal noble et la longueur d’onde d’excitation du plasmon de surface sont influencées par les caractéristiques des réseaux de nanotrous. Dans les travaux rapportés ici, la nature du métal utilisé, le diamètre ainsi que la périodicité des trous sont variés pour étudier leur influence sur les bandes LSPR du spectre en transmission pour maximiser cette sensibilité, visant la fabrication d’un biocapteur. Les surfaces d’argent, ayant un diamètre de nanotrous inférieur à 200 nm pour une périodicité de 450 nm et les nanotrous d’une périodicité de 650 nm démontre un potentiel de sensibilité supérieur.
Resumo:
Cette thèse caractérise les propriétés optiques des matériaux plasmoniques microstructurés et procède à l’évaluation des paramètres analytiques afin de les employer comme plateforme de biodétection en spectroscopie de résonance des plasmons de surface (SPR). Aux dimensions micrométriques, les matériaux plasmoniques présentent des caractéristiques optiques propres aux nano- et macromatériaux. La cartographie physicooptiques en SPR de matériaux méso- et microscopiques s’est effectuée à l’aide de films structurés de motifs périodiques triangulaires et circulaires fabriqués par une technique modifiée de lithographie par nanosphères (nanosphere lithography, NSL). À partir de cette vue d’ensemble, quelques films structurés ont été sélectionné en fonction d’aspects analytiques tels que la sensibilité et la résolution face aux variations d’indice de réfraction (RI) pour déterminer le potentiel de ces matériaux comme plateforme de biodetection. Les propriétés optiques distinctes des films microstructurés proviennent d’interactions résonantes entre les modes de plasmons de surface (SP) localisé et délocalisé identifiés par la relation de dispersion en SPR ainsi que l’imagerie Raman. Les conditions de résonance des modes SP dépendant de paramètres expérimentaux (λ, θ, η) tel qu’observés numériquement par rigorous coupled wave analysis (RCWA) et empiriquement. Ces travaux démontrent la nature plasmonique distincte des micro-matériaux et leur potentiel d’intégration aux techniques analytiques SPR existantes. Les matériaux plasmoniques micrométriques furent également étudiés pour l’implémentation de la SPR à une pointe de microscopie à force atomique (atomic force microscopy, AFM) combinant ainsi la spectroscopie à l’imagerie topographique. Des travaux préliminaires se sont concentrés sur la signature spectroscopique de leviers en silicium (Si) et en nitrure de silicium (Si3N4), l’impact d’un revêtement d’or sur les pointes et l’influence de milieu environnant. Une image d’origine plasmonique a été obtenue avec des leviers en Si3N4 revêtus d’or en transmission dans un environnement aqueux, indiquant ainsi le potentiel de ces pointes comme micro-biocapteur SPR. Ces résultats préliminaires servent de fondement pour orienter les prochaines investigations dans ce projet.
Resumo:
L’oxydoréduction de monocouches auto-assemblées (SAMs) de ferrocénylalcanethiolates à la surface d’or (FcRSAu) a été étudiée en temps réel par la spectroscopie de résonance de plasmons de surface couplée avec l’électrochimie (E-SPR). La sensibilité de cette technique permet de déterminer des changements d’épaisseur de couche l’ordre de quelques angström résultant d’un changement de structure de la SAM. Plusieurs études antérieures ont proposé que l’oxydation électrochimique d’une SAM de FcRSAu induit une réorientation moléculaire. L’E-SPR est utilisé pour identifier l’origine de ce changement structurel. D’abord, une calibration du réfractomètre SPR utilisé a été effectuée afin de trouver une équation de conversion du signal SPR obtenu en pixel en angle d’incidence pour que l’on puisse calculer le changement d’épaisseur de monocouche à partir du changement d’angle de résonance avec le modèle de Fresnel. Par la suite, une caractérisation approfondie des SAMs de FcCnSAu (où n = 6, 8, 12, 14) en contact avec du NaClO4 acidifié a été réalisée par électrochimie, éllipsométrie, spectroscopie infrarouge et microscopie à force atomique. Les résultats obtenus montrent que l’augmentation de la longueur des chaînes alkyles donne des SAMs de ferrocènes plus épaisses et moins désordonnées. L’analyse par l’E-SPR de ces SAMs pures montre que le changement d’épaisseur induit par l’électro-oxydation dépend linéairement du nombre de méthylènes sur la chaîne alkyle. En appliquant la déconvolution mathématique aux voltampérogrammes cycliques enregistrés pour les SAM mixtes (FcC12SAu/C11SAu) de différentes compositions, on arrive à la conclusion qu’il y a un redressement des chaînes alkyles dans les domaines des ferrocènes agrégés mais la réorientation des têtes de ferrocène dans les domaines de ferrocènes agrégés ou dispersés ne peut pas être exclue. Enfin, l’effet de l’anion électrolytique sur le changement d’épaisseur de la SAM mesuré par l’E-SPR a été étudié. L’analyse électrochimique montre que la capacité de pairage d’anions avec les ferrocéniums décroit comme suit : PF6- > ClO4- > BF4- > NO3-. Tandis que l’épaisseur de la SAM donnée par le changement d’angle de résonance suit la tendance suivante : NO3- ≥ ClO4- > PF6- ≈ BF4-. Des études plus approfondies seront nécessaire pour clarifier cette tendance observée par E-SPR.
Resumo:
We describe the development of a label free method to analyze the interactions between Ca(2+) and the porcine S100A12 protein immobilized on polyvinyl butyral (PVB). The modified gold electrodes were characterized using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM) and surface plasmon resonance (SPR) techniques. SEM analyses of PVB and PVB-S100A12 showed a heterogeneous distribution of PVB spherules on gold surface. EIS and CV measurements have shown that redox probe reactions on the modified gold electrodes were partially blocked due the adsorption of PVB-S100A12, and confirm the existence of a positive response of the immobilized S100Al2 to the presence of calcium ions. The biosensor exhibited a wide linear response to Ca(2+) concentrations ranging from 12.5 to 200 mM. The PVB-S100A12 seems to be bound to the gold electrode surface by physical adsorption: we observed an increase of 1184.32 m degrees in the SPR angle after the adsorption of the protein on the PVB surface (in an indication that 9.84 ng of S100A12 are adsorbed per mm(2) of the Au-PVB electrode), followed by a further increase of 581.66 m degrees after attachment of the Ca(2+) ions. In addition, no SPR response is obtained for non-specific ions. These studies might be useful as a platform for the design of new reusable and sensitive biosensing devices that could find use in the clinical applications. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Hydrogen interaction with oxide films grown on iron electrodes at open circuit potential (E-oc) and in the passive region (+0.30 V-ECS) was studied by chronopotentiometry, chronoamperometry and electrochemical impedance spectroscopy techniques. The results were obtained in deaerated 0.3 mol L-1 H3BO3 + 0.075 mol L-1 Na2B4O7 (BB, pH 8.4) solution before, during and after hydrogen permeation. The iron oxide film modification was also investigated by means of in situ X-ray absorption near-edge spectroscopy (XANES) and scanning electrochemical microscopy (SECM) before and during hydrogen permeation. The main conclusion was that the passive film is reduced during the hydrogen diffusion. The hydrogen permeation stabilizes the iron surface at a potential close to the thermodynamic water stability line where hydrogen evolution can occur. The stationary condition required for the determination of the permeation parameters cannot be easily attained on iron surface during hydrogen permeation. Moreover, additional attention must be paid when obtaining the transport parameters using the classical permeation cell. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The polycrystalline sample of Nd3/2Bi3/2Fe5O12 was prepared by a high- temperature solid-state reaction technique. Preliminary X-ray structural analysis exhibits the formation of a single-phase tetragonal structure at room temperature. Microstructural analysis by scanning electron microscopy shows that the sintered sample has well defined grains. These grains are distributed uniformly throughout the surface of the sample. Detailed studies of dielectric response at various frequencies and temperatures exhibit a dielectric anomaly at 400 A degrees C. The electrical properties (impedance, modulus and conductivity) of the material were studied using a complex impedance spectroscopy technique. These studies reveal a significant contribution of grain and grain boundary effects in the material. The frequency dependent plots of modulus and the impedance loss show that the conductivity relaxation is of non-Debye type. Studies of electrical conductivity with temperature demonstrate that the compound exhibits Arrhenius-type of electrical conductivity. Study of ac conductivity with frequency suggests that the material obeys Jonscher's universal power law.
Resumo:
We report here the utilization of atomid layer deposition to passivate surface map states in mosoporous TiO2 nanoparticles for solid state dye sensitized solar cells based on 9,9'-spirobifluorene (spiro-OMeTAD). By depositing ZrO2 films with angstrom-level precision, coating the mesoporous TiO2 produces over a two-fold enhancement in short-circuit current density, as compared to a control device. Impedance spectroscopy measurements provide evidence that the ZrO2 coating reduces recombination lossed at the TiO2/spiro-OMeTAD interface and passivates localized surface states. Low-frequency negative capacitances, frequently observed in nanocomposite solar cells, have been associated with the surface-state mediated charge transfer from TiO2 to the spiro-OMeTAD.
Resumo:
Glassy carbon electrodes (GCE) were modified with poly(glutamic acid) acid films prepared using three different procedures: glutamic acid monomer electropolymerization (MONO), evaporation of poly(glutamic acid) (PAG) and evaporation of a mixture of poly(glutamic acid)/glutaraldehyde (PAG/GLU). All three films showed good adherence to the electrode surface. The performance of the modified GCE was investigated by cyclic voltammetry and differential pulse voltammetry, and the films were characterized by atomic force microscopy (AFM) and electrochemical impedance spectroscopy (EIS). The three poly(glutamic acid) modified GCEs were tested using the electrochemical oxidation of ascorbic acid and a decrease of the overpotential and the improvement of the oxidation peak current was observed. The PAG modified electrode surfaces gave the best results. AFM morphological images showed a polymeric network film formed by well-defined nanofibres that may undergo extensive swelling in solution, allowing an easier electron transfer and higher oxidation peaks. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
The dielectric properties and loss of Bi1.5ZnSb1.5O7 a poor-semiconducting ceramic were investigated by impedance spectroscopy, in the frequency range from 5 Hz to 13 MHz. Electric measurements were performed from 100 to 700 degreesC. Pyrochlore type phase was synthesized by the polymeric precursor method. Dense ceramic with 97% of the theoretical density was prepared by sintering via constant heating rate. The dielectric permittivity dependence as a function of frequency and temperature showed a strong dispersion at frequency lower than 10 kHz. The losses (tan delta) exhibit slight dependence with the frequency at low temperatures presenting a strong increase at temperatures higher than 400 degreesC. A decrease of the loss magnitude occurs with increasing frequency. Relaxation times were extracted using the dielectric functions Z(omega) and M(omega). The plots of the relaxation times tau(Z'), and tau(M) as a function of temperature follow the Arrhenius law, where a single slope is observed with activation energy values equal to 1.38 and 1.37 eV, respectively. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
dThe detection of aromatic compounds from pesticides and industrial wastewater has become of great interest, since these compounds withstand chemical oxidation and biological degradation, accumulating in the environment. In this work, a highly sensitive biosensor for detecting catechol was obtained with the immobilization of Cl-catechol 1,2-dioxygenase (CCD) in nanostructured films. CCD layers were alternated with poly(amidoamine) generation 4 (PAMAM G4) dendrimer using the electrostatic layer-by-layer (LbL) technique. Circular dichroism (CD) measurements indicated that the immobilized CCD preserved the same conformation as in solution. The thickness of the very first CCD layers in the LbL films was estimated at ca. 3.6 nm, as revealed by surface plasmon resonance (SPR). PAMAM/CCD 10-bilayer films were employed in detecting diluted catechol solutions using either an optical or electrical approach. Due to the mild immobilization conditions employed, especially regarding the pH and ionic strength of the dipping solutions, CCD remained active in the films for periods longer than 3 weeks. The optical detection comprised absorption experiments in which the formation of cis-cis muconic acid, resulting from the reaction between CCD and catechol, was monitored by measuring the absorbance at 260 nm after film immersion in catechol solutions. The electrical detection was carried out using LbL films deposited onto gold-interdigitated electrodes immersed in aqueous solutions at different catechol concentrations. Using impedance spectroscopy in a broad frequency range (1Hz-1kHz), we could detect catechol in solutions at concentrations as low as 10(-10) M. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Hydrogen evolution reaction was studied on Ni-Zn (25% of Ni before leaching) in 1 M NaOH at 25 degrees C. These electrodes were characterized by very low Tafel slopes of 67 mV dec(-1). Other techniques used included potential and current pulse, potential relaxation in an open circuit, and ac impedance spectroscopy. Analysis of the experimental results led to the conclusion that hydrogen adsorption in the surface layers was responsible for the observed behavior. Influence of the oxidation of the electrode surface and the addition of poisons, thiourea and cyanides, were also studied. These processes inhibit the hydrogen absorption and restore ''normal'' Tafel slopes. Kinetic parameters of the hydrogen evolution reaction were determined.