978 resultados para Somatosensory response detection


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To assess the value of cusum analysis in hospital bed management. Design: Comparative analysis of medical patient flows, bed occupancy, and emergency department admission rates and access block over 2 years. Setting: Internal Medicine Services and Emergency Department in a teaching hospital. Interventions: Improvements in bed use and changes in the level of available beds. Main outcome measures: Average length of stay; percentage occupancy of available beds; number of patients waiting more than 8 hours for admission (access block); number of medical patients occupying beds in non-medical wards; and number of elective surgical admissions. Results: Cusum analysis provided a simple means of revealing important trends in patient flows that were not obvious in conventional time-series data. This prompted improvements in bed use that resulted in a decrease of 9500 occupied bed-days over a year. Unfortunately and unexpectedly, after some initial improvement, the levels of access block, medical ward congestion and elective surgical admissions all then deteriorated significantly. This was probably caused by excessive bed closures in response to the initial improvement in bed use. Conclusion: Cusum analysis is a useful technique for the early detection of significant changes in patient flows and bed use, and in determining the appropriate number of beds required for a given rate of patient flow.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Our group has developed an ovine model of deep dermal, partial-thickness burn where the fetus heals scarlessly and the lamb heals with scar. The comparison of collagen structure between these two different mechanisms of healing may elucidate the process of scarless wound healing. Picrosirius staining followed by polarized light microscopy was used to visualize collagen fibers, with digital capture and analysis. Collagen deposition increased with fetal age and the fibers became thicker, changing from green (type III collagen) to yellow/red (type I collagen). The ratio of type III collagen to type I was high in the fetus (166), whereas the lamb had a much lower ratio (0.2). After burn, the ratios of type III to type I collagen did not differ from those in control skin for either fetus or lamb. The fetal tissue maintained normal tissue architecture after burn while the lamb tissue showed irregular collagen organization. In conclusion, the type or amount of collagen does not alter significantly after injury. Tissue architecture differed between fetal and lamb tissue, suggesting that scar development is related to collagen cross-linking or arrangement. This study indicates that healing in the scarless fetal wound is representative of the normal fetal growth pattern, rather than a response to burn injury.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel phytotoxicity assay was incorporated into an environmental assessment of Hervey Bay and the Great Sandy Straits, to investigate the role of run-off associated herbicides in the deteriorated health of intertidal seagrass meadows. Dose response curves of common herbicides were performed and their toxicity equivalents elucidated to assist in analysis. The results of the assay were reproducible and corresponded strongly with results of chemical analyses. The incorporation of the assay into the assessment of surface waters added an important aspect to the study by allowing investigation of the toxicity of cumulative herbicide concentrations and yielding biologically relevant data. The highest herbicide concentration detected during the study was equivalent to 0.23 mu g 1(-1) diuron; a concentration known to inhibit photosynthetic efficiency of the assay biomaterial by approximately 3%. (c) 2004 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In various signal-channel-estimation problems, the channel being estimated may be well approximated by a discrete finite impulse response (FIR) model with sparsely separated active or nonzero taps. A common approach to estimating such channels involves a discrete normalized least-mean-square (NLMS) adaptive FIR filter, every tap of which is adapted at each sample interval. Such an approach suffers from slow convergence rates and poor tracking when the required FIR filter is "long." Recently, NLMS-based algorithms have been proposed that employ least-squares-based structural detection techniques to exploit possible sparse channel structure and subsequently provide improved estimation performance. However, these algorithms perform poorly when there is a large dynamic range amongst the active taps. In this paper, we propose two modifications to the previous algorithms, which essentially remove this limitation. The modifications also significantly improve the applicability of the detection technique to structurally time varying channels. Importantly, for sparse channels, the computational cost of the newly proposed detection-guided NLMS estimator is only marginally greater than that of the standard NLMS estimator. Simulations demonstrate the favourable performance of the newly proposed algorithm. © 2006 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

* Chronic heart failure (CHF) is found in 1.5%–2.0% of Australians. Considered rare in people aged less than 45 years, its prevalence increases to over 10% in people aged ≥ 65 years. * CHF is one of the most common reasons for hospital admission and general practitioner consultation in the elderly (≥ 70 years). * Common causes of CHF are ischaemic heart disease (present in > 50% of new cases), hypertension (about two-thirds of cases) and idiopathic dilated cardiomyopathy (around 5%–10% of cases). * Diagnosis is based on clinical features, chest x-ray and objective measurement of ventricular function (eg, echocardiography). Plasma levels of B-type natriuretic peptide (BNP) may have a role in diagnosis, primarily as a test for exclusion. Diagnosis may be strengthened by a beneficial clinical response to treatment(s) directed towards amelioration of symptoms. * Management involves prevention, early detection, amelioration of disease progression, relief of symptoms, minimisation of exacerbations, and prolongation of survival.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the detection of human papillomavirus (HPV) 16 antibody in HPV 16-associated cervical intraepithelial neoplasia (CIN) in Australian women. Seroreactivity to HPV 16 L1 virus-like particles was assessed in patients with CIN 2 (n = 169) and CIN 3 (n = 229) lesions previously tested for the presence of HPV DNA. Seropositivity was significantly commoner in women with HPV 16 DNA-positive lesions (98/184) than in women with no HPV DNA in the lesion (15/47) or with HPV of types other than 16 in the lesion (43/167) (P = 0.0004). In addition, seropositivity was observed in 33% (55/169) of women with CIN 2 and 46% (106/229) of women with CIN 3, in keeping with the lower fraction of CIN 2 (57/169) than CIN 3 (127/229) biopsies positive for HPV 16 DNA. HPV 16 seropositivity is most common in women with HPV 16-associated CIN, but many patients with HPV-associated CIN 3 are seronegative, and HPV 16 seropositivity is common in women with CIN associated with other HPV types. Overall, HPV 16 serology is a poor predictor of presence of HPV 16-associated CIN 3 in patient population studied.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fuzzy signal detection analysis can be a useful complementary technique to traditional signal detection theory analysis methods, particularly in applied settings. For example, traffic situations are better conceived as being on a continuum from no potential for hazard to high potential, rather than either having potential or not having potential. This study examined the relative contribution of sensitivity and response bias to explaining differences in the hazard perception performance of novices and experienced drivers, and the effect of a training manipulation. Novice drivers and experienced drivers were compared (N = 64). Half the novices received training, while the experienced drivers and half the novices remained untrained. Participants completed a hazard perception test and rated potential for hazard in occluded scenes. The response latency of participants to the hazard perception test replicated previous findings of experienced/novice differences and trained/untrained differences. Fuzzy signal detection analysis of both the hazard perception task and the occluded rating task suggested that response bias may be more central to hazard perception test performance than sensitivity, with trained and experienced drivers responding faster and with a more liberal bias than untrained novices. Implications for driver training and the hazard perception test are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We assessed summation of contrast across eyes and area at detection threshold ( C t). Stimuli were sine-wave gratings (2.5 c/deg) spatially modulated by cosine- and anticosine-phase raised plaids (0.5 c/deg components oriented at ±45°). When presented dichoptically the signal regions were interdigitated across eyes but produced a smooth continuous grating following their linear binocular sum. The average summation ratio ( C t1/([ C t1+2]) for this stimulus pair was 1.64 (4.3 dB). This was only slightly less than the binocular summation found for the same patch type presented to both eyes, and the area summation found for the two different patch types presented to the same eye. We considered 192 model architectures containing each of the following four elements in all possible orders: (i) linear summation or a MAX operator across eyes, (ii) linear summation or a MAX operator across area, (iii) linear or accelerating contrast transduction, and (iv) additive Gaussian, stochastic noise. Formal equivalences reduced this to 62 different models. The most successful four-element model was: linear summation across eyes followed by nonlinear contrast transduction, linear summation across area, and late noise. Model performance was enhanced when additional nonlinearities were placed before binocular summation and after area summation. The implications for models of probability summation and uncertainty are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The Nidek F-10 is a scanning laser ophthalmoscope that is capable of a novel fundus imaging technique, so-called ‘retro-mode’ imaging. The standard method of imaging drusen in age-related macular degeneration (AMD) is by fundus photography. The aim of the study was to assess drusen quantification using retro-mode imaging. Methods: Stereoscopic fundus photographs and retro-mode images were captured in 31 eyes of 20 patients with varying stages of AMD. Two experienced masked retinal graders independently assessed images for the number and size of drusen, using purpose-designed software. Drusen were further assessed in a subset of eight patients using optical coherence tomography (OCT) imaging. Results: Drusen observed by fundus photography (mean 33.5) were significantly fewer in number than subretinal deposits seen in retro-mode (mean 81.6; p < 0.001). The predominant deposit diameter was on average 5 µm smaller in retro-mode imaging than in fundus photography (p = 0.004). Agreement between graders for both types of imaging was substantial for number of deposits (weighted ? = 0.69) and moderate for size of deposits (weighted ? = 0.42). Retro-mode deposits corresponded to drusen on OCT imaging in all eight patients. Conclusion: The subretinal deposits detected by retro-mode imaging were consistent with the appearance of drusen on OCT imaging; however, a larger longitudinal study would be required to confirm this finding. Retro-mode imaging detected significantly more deposits than conventional colour fundus photography. Retro-mode imaging provides a rapid non-invasive technique, useful in monitoring subtle changes and progression of AMD, which may be useful in monitoring the response of drusen to future therapeutic interventions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We propose a novel electroencephalographic application of a recently developed cerebral source extraction method (Functional Source Separation, FSS), which starts from extracranial signals and adds a functional constraint to the cost function of a basic independent component analysis model without requiring solutions to be independent. Five ad-hoc functional constraints were used to extract the activity reflecting the temporal sequence of sensory information processing along the somatosensory pathway in response to the separate left and right median nerve galvanic stimulation. Constraints required only the maximization of the responsiveness at specific latencies following sensory stimulation, without taking into account that any frequency or spatial information. After source extraction, the reliability of identified FS was assessed based on the position of single dipoles fitted on its retroprojected signals and on a discrepancy measure. The FS positions were consistent with previously reported data (two early subcortical sources localized in the brain stem and thalamus, the three later sources in cortical areas), leaving negligible residual activity at the corresponding latencies. The high-frequency component of the oscillatory activity (HFO) of the extracted component was analyzed. The integrity of the low amplitude HFOs was preserved for each FS. On the basis of our data, we suggest that FSS can be an effective tool to investigate the HFO behavior of the different neuronal pools, recruited at successive times after median nerve galvanic stimulation. As FSs are reconstructed along the entire experimental session, directional and dynamic HFO synchronization phenomena can be studied.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To investigate the dynamics of communication within the primary somatosensory neuronal network. Methods: Multichannel EEG responses evoked by median nerve stimulation were recorded from six healthy participants. We investigated the directional connectivity of the evoked responses by assessing the Partial Directed Coherence (PDC) among five neuronal nodes (brainstem, thalamus and three in the primary sensorimotor cortex), which had been identified by using the Functional Source Separation (FSS) algorithm. We analyzed directional connectivity separately in the low (1-200. Hz, LF) and high (450-750. Hz, HF) frequency ranges. Results: LF forward connectivity showed peaks at 16, 20, 30 and 50. ms post-stimulus. An estimate of the strength of connectivity was modulated by feedback involving cortical and subcortical nodes. In HF, forward connectivity showed peaks at 20, 30 and 50. ms, with no apparent feedback-related strength changes. Conclusions: In this first non-invasive study in humans, we documented directional connectivity across subcortical and cortical somatosensory pathway, discriminating transmission properties within LF and HF ranges. Significance: The combined use of FSS and PDC in a simple protocol such as median nerve stimulation sheds light on how high and low frequency components of the somatosensory evoked response are functionally interrelated in sustaining somatosensory perception in healthy individuals. Thus, these components may potentially be explored as biomarkers of pathological conditions. © 2012 International Federation of Clinical Neurophysiology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel device for the detection and characterisation of static magnetic fields is presented. It consists of a femtosecond laser inscribed fibre Bragg grating (FBG) that is incorporated into an optical fibre with a femtosecond laser micromachined slot. The symmetry of the fibre is broken by the micro-slot, producing non-uniform strain across the fibre cross section. The sensing region is coated with Terfenol-D making the device sensitive to static magnetic fields, whereas the symmetry breaking results in a vectorial sensor for the detection of magnetic fields as low as 0.046 mT with a resolution of ±0.3mT in transmission and ±0.7mT in reflection. The sensor output is directly wavelength encoded from the FBG filtering, leading to simple demodulation through the monitoring of wavelength shifts that result as the fibre structure changes shape in response to the external magnetic field. The use of a femtosecond laser to both inscribe the FBG and micro-machine the slot in a single stage, prior to coating the device, significantly simplifies the sensor fabrication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel device for the detection and characterisation of static magnetic fields is presented. It consists of a femtosecond laser inscribed fibre Bragg grating (FBG) that is incorporated into an optical fibre with a femtosecond laser micromachined slot. The symmetry of the fibre is broken by the micro-slot, producing non-uniform strain across the fibre cross section. The sensing region is coated with Terfenol-D making the device sensitive to static magnetic fields, whereas the symmetry breaking results in a vectorial sensor for the detection of magnetic fields as low as 0.046 mT with a resolution of ±0.3mT in transmission and ±0.7mT in reflection. The sensor output is directly wavelength encoded from the FBG filtering, leading to simple demodulation through the monitoring of wavelength shifts that result as the fibre structure changes shape in response to the external magnetic field. The use of a femtosecond laser to both inscribe the FBG and micro-machine the slot in a single stage, prior to coating the device, significantly simplifies the sensor fabrication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gamma oscillations have previously been linked to pain perception and it has been hypothesised that they may have a potential role in encoding pain intensity. Stimulus response experiments have reported an increase in activity in the primary somatosensory cortex (SI) with increasing stimulus intensity, but the specific role of oscillatory dynamics in this change in activation remains unclear. In this study, Magnetoencephalography (MEG) was used to investigate the changes in cortical oscillations during 4 different intensities of a train of electrical stimuli to the right index finger, ranging from low sensation to strong pain. In those participants showing changes in evoked oscillatory gamma in SI during stimulation, the strength of the gamma power was found to increase with increasing stimulus intensity at both pain and sub-pain thresholds. These results suggest that evoked gamma oscillations in SI are not specific to pain but may have a role in encoding somatosensory stimulus intensity. © 2013 Rossiter, Worthen, Witton, Hall and Furlong.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Many factors can be, and have been, attributed to the appearance of complications in lens wear, but the greatest is associated with deposition. Reduced acuity, irritation and inflammatory responses are often referred to as adverse reactions arising as a result of deposition. In this study, particular attention was paid to the potential role of adsorbed proteins in activating, mediating and/or stimulating a host immune response, i.e., the hypothesis that the adsorption of certain proteins from the tears and ocular surfaces may actively affect successful lens wear. In particular, the purpose of this study was to investigate the presence of a group of proteins previously undiscovered in the ocular environment. The intention was to target a family of proteins/glycoproteins that have become prominent recently in a variety of inflammatory responses and disorders at many other mucosal associated sites around the body, e.g. in nasal rhinitis and in joint inflammation. The protein cascade in question is the kinin family of inflammatory mediators. The aim was to investigate their presence in the ocular environment, specifically in relation to contact lens wear, and consequently assess the implications of their discovery. High molecular weight kininogen (HMWK), with its central role in kinin responses, was investigated initially as the marker of kinin activity, with subsequent members examined thereafter.