958 resultados para Single overhead rate


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Calmodulin (CaM) is a ubiquitous Ca(2+) buffer and second messenger that affects cellular function as diverse as cardiac excitability, synaptic plasticity, and gene transcription. In CA1 pyramidal neurons, CaM regulates two opposing Ca(2+)-dependent processes that underlie memory formation: long-term potentiation (LTP) and long-term depression (LTD). Induction of LTP and LTD require activation of Ca(2+)-CaM-dependent enzymes: Ca(2+)/CaM-dependent kinase II (CaMKII) and calcineurin, respectively. Yet, it remains unclear as to how Ca(2+) and CaM produce these two opposing effects, LTP and LTD. CaM binds 4 Ca(2+) ions: two in its N-terminal lobe and two in its C-terminal lobe. Experimental studies have shown that the N- and C-terminal lobes of CaM have different binding kinetics toward Ca(2+) and its downstream targets. This may suggest that each lobe of CaM differentially responds to Ca(2+) signal patterns. Here, we use a novel event-driven particle-based Monte Carlo simulation and statistical point pattern analysis to explore the spatial and temporal dynamics of lobe-specific Ca(2+)-CaM interaction at the single molecule level. We show that the N-lobe of CaM, but not the C-lobe, exhibits a nano-scale domain of activation that is highly sensitive to the location of Ca(2+) channels, and to the microscopic injection rate of Ca(2+) ions. We also demonstrate that Ca(2+) saturation takes place via two different pathways depending on the Ca(2+) injection rate, one dominated by the N-terminal lobe, and the other one by the C-terminal lobe. Taken together, these results suggest that the two lobes of CaM function as distinct Ca(2+) sensors that can differentially transduce Ca(2+) influx to downstream targets. We discuss a possible role of the N-terminal lobe-specific Ca(2+)-CaM nano-domain in CaMKII activation required for the induction of synaptic plasticity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The treatment of peri-prosthetic joint infection (PJI) of the ankle is not standardised. It is not clear whether an algorithm developed for hip and knee PJI can be used in the management of PJI of the ankle. We evaluated the outcome, at two or more years post-operatively, in 34 patients with PJI of the ankle, identified from a cohort of 511 patients who had undergone total ankle replacement. Their median age was 62.1 years (53.3 to 68.2), and 20 patients were women. Infection was exogenous in 28 (82.4%) and haematogenous in six (17.6%); 19 (55.9%) were acute infections and 15 (44.1%) chronic. Staphylococci were the cause of 24 infections (70.6%). Surgery with retention of one or both components was undertaken in 21 patients (61.8%), both components were replaced in ten (29.4%), and arthrodesis was undertaken in three (8.8%). An infection-free outcome with satisfactory function of the ankle was obtained in 23 patients (67.6%). The best rate of cure followed the exchange of both components (9/10, 90%). In the 21 patients in whom one or both components were retained, four had a relapse of the same infecting organism and three had an infection with another organism. Hence the rate of cure was 66.7% (14 of 21). In these 21 patients, we compared the treatment given to an algorithm developed for the treatment of PJI of the knee and hip. In 17 (80.9%) patients, treatment was not according to the algorithm. Most (11 of 17) had only one criterion against retention of one or both components. In all, ten of 11 patients with severe soft-tissue compromise as a single criterion had a relapse-free survival. We propose that the treatment concept for PJI of the ankle requires adaptation of the grading of quality of the soft tissues. Cite this article: Bone Joint J 2014;96-B:772-7.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE Caesarean section (CS) rates have risen over the past two decades. The aim of this observational study was to identify time-dependent variations in CS and vaginal delivery rates over a period of 11 years. METHOD All deliveries (13,701 deliveries during the period 1999-2009) at the University Women's Hospital Bern were analysed using an internationally standardised and approved ten-group classification system. Caesarean sections on maternal request (CSMR) were evaluated separately. RESULTS We detected an overall CS rate of 36.63% and an increase in the CS rate over time (p <0.001). Low-risk profile groups were the two largest populations and displayed low CS rates, with significantly decreasing relative size over time. The relative size of groups with induced labour increased significantly, but this did not have an impact on the overall CS rate. Pregnancies complicated by breech position, multiple pregnancies and abnormal lies did not have an impact on overall CS rate. The biggest contributor to a high CS rate was preterm delivery and the existence of a uterine scar from a previous CS. CSMR was 1.45% and did not have an impact on the overall CS rate. CONCLUSION The observational study identified wide variations in caesarean section and vaginal delivery rates across the groups over time, and a shift towards high-risk populations was noted. The biggest contributors to high CS rates were identified; namely, previous uterine scar and preterm delivery. Interventions aiming to reduce CS rates are planned.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

STUDY QUESTION Does intrauterine application of diluted seminal plasma (SP) at the time of ovum pick-up improve the pregnancy rate by ≥14% in IVF treatment? SUMMARY ANSWER Intrauterine instillation of diluted SP at the time of ovum pick-up is unlikely to increase the pregnancy rate by ≥14% in IVF. WHAT IS KNOWN ALREADY SP modulates endometrial function, and sexual intercourse around the time of embryo transfer has been suggested to increase the likelihood of pregnancy. A previous randomized double-blind pilot study demonstrated a strong trend towards increased pregnancy rates following the intracervical application of undiluted SP. As this study was not conclusive and as the finding could have been confounded by sexual intercourse, the intrauterine application of diluted SP was investigated in the present trial. STUDY DESIGN, SIZE, DURATION A single-centre, prospective, double-blind, placebo-controlled, randomized, superiority trial on women undergoing IVF was conducted from April 2007 until February 2012 at the University Department of Gynaecological Endocrinology and Reproductive Medicine, Heidelberg, Germany. PARTICIPANTS/MATERIALS, SETTING, METHODS The study was powered to detect an 14% increase in the clinical pregnancy rate and two sequential tests were planned using the Pocock spending function. At the first interim analysis, 279 women had been randomly assigned to intrauterine diluted SP (20% SP in saline from the patients' partner) (n = 138) or placebo (n = 141) at the time of ovum pick-up. MAIN RESULTS AND THE ROLE OF CHANCE The clinical pregnancy rate per randomized patient was 37/138 (26.8%) in the SP group and 41/141 (29.1%) in the placebo group (difference: -2.3%, 95% confidence interval of the difference: -12.7 to +8.2%; P = 0.69). The live birth rate per randomized patient was 28/138 (20.3%) in the SP group and 33/141 (23.4%) in the placebo group (difference: -3.1%, 95% confidence interval of the difference: -12.7 to +6.6%; P = 0.56). It was decided to terminate the trial due to futility at the first interim analysis, at a conditional power of 62%. LIMITATIONS, REASONS FOR CAUTION The confidence interval of the difference remains wide, thus clinically relevant differences cannot reliably be excluded based on this single study. WIDER IMPLICATIONS OF THE FINDINGS The results of this study cast doubt on the validity of the concept that SP increases endometrial receptivity and thus implantation in humans. STUDY FUNDING/COMPETING INTEREST(S) Funding was provided by the department's own research facilities. TRIAL REGISTRATION NUMBER DRKS00004615.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-blind, non-inferiority trial with minimum exclusion criteria at nine hospitals in Switzerland. We randomly assigned (1:1) patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes undergoing percutaneous coronary intervention to treatment with biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Randomisation was via a central web-based system and stratified by centre and presence of ST segment elevation myocardial infarction. Patients and outcome assessors were masked to treatment allocation, but treating physicians were not. The primary endpoint, target lesion failure, was a composite of cardiac death, target vessel myocardial infarction, and clinically-indicated target lesion revascularisation at 12 months. A margin of 3·5% was defined for non-inferiority of the biodegradable polymer sirolimus-eluting stent compared with the durable polymer everolimus-eluting stent. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT01443104. FINDINGS Between Feb 24, 2012, and May 22, 2013, we randomly assigned 2119 patients with 3139 lesions to treatment with sirolimus-eluting stents (1063 patients, 1594 lesions) or everolimus-eluting stents (1056 patients, 1545 lesions). 407 (19%) patients presented with ST-segment elevation myocardial infarction. Target lesion failure with biodegradable polymer sirolimus-eluting stents (69 cases; 6·5%) was non-inferior to durable polymer everolimus-eluting stents (70 cases; 6·6%) at 12 months (absolute risk difference -0·14%, upper limit of one-sided 95% CI 1·97%, p for non-inferiority <0·0004). No significant differences were noted in rates of definite stent thrombosis (9 [0·9%] vs 4 [0·4%], rate ratio [RR] 2·26, 95% CI 0·70-7·33, p=0·16). In pre-specified stratified analyses of the primary endpoint, biodegradable polymer sirolimus-eluting stents were associated with improved outcome compared with durable polymer everolimus-eluting stents in the subgroup of patients with ST-segment elevation myocardial infarction (7 [3·3%] vs 17 [8·7%], RR 0·38, 95% CI 0·16-0·91, p=0·024, p for interaction=0·014). INTERPRETATION In a patient population with minimum exclusion criteria and high adherence to dual antiplatelet therapy, biodegradable polymer sirolimus-eluting stents were non-inferior to durable polymer everolimus-eluting stents for the combined safety and efficacy outcome target lesion failure at 12 months. The noted benefit in the subgroup of patients with ST-segment elevation myocardial infarction needs further study. FUNDING Clinical Trials Unit, University of Bern, and Biotronik, Bülach, Switzerland.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dexmedetomidine and lignocaine IV are used clinically to provide analgesia in horses. The aims of this study were to investigate the antinociceptive effects, plasma concentrations and sedative effects of 2, 4 and 6 µg/kg/h dexmedetomidine IV, with a bolus of 0.96 µg/kg preceding each continuous rate infusion (CRI), and 20, 40 and 60 µg/kg/min lignocaine IV, with a bolus of 550 µg/kg preceding each CRI, in 10 Swiss Warmblood horses. Electrically elicited nociceptive withdrawal reflexes were evaluated by deltoid muscle electromyography. Nociceptive threshold and tolerance were determined by electromyography and behaviour following single and repeated stimulation. Plasma concentrations of drugs were determined by liquid chromatography and mass spectrometry. Sedation was scored on a visual analogue scale. Dexmedetomidine increased nociceptive threshold to single and repeated stimulation for all CRIs, except at 2 µg/kg/h, where no increase in single stimulation nociceptive threshold was observed. Dexmedetomidine increased nociceptive tolerance to single and repeated stimulation at all CRIs. There was large individual variability in dexmedetomidine plasma concentrations and levels of sedation; the median plasma concentration providing antinociceptive effects to all recorded parameters was 0.15 ng/mL, with a range from <0.02 ng/mL (below the lower limit of quantification) to 0.25 ng/mL. Lignocaine increased nociceptive threshold and tolerance to single and repeated stimulation at CRIs of 40 and 60 µg/kg/min, corresponding to plasma lignocaine concentrations >600 ng/mL. Only nociceptive tolerance to repeated stimulation increased at 20 µg/kg/min lignocaine. Lignocaine at 40 µg/kg/min and dexmedetomidine at 4 µg/kg/h were the lowest CRIs resulting in consistent antinociception. Lignocaine did not induce significant sedation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE Clinical studies related to the long-term outcomes with implant-supported reconstructions are still sparse. The aim of this 10-year retrospective study was to assess the rate of mechanical/technical complications and failures with implant supported fixed dental prostheses (FDPs) and single crowns (SCs) in a large cohort of partially edentulous patients. MATERIALS AND METHODS The comprehensive multidisciplinary examination consisted of a medical/dental history, clinical examination, and a radiographic analysis. Prosthodontic examination evaluated the implant-supported reconstructions for mechanical/technical complications and failures, occlusal analysis, presence/absence of attrition, and location, extension, and retention type. RESULTS Out of three hundred ninety seven fixed reconstructions in three hundred three patients, two hundred sixty eight were SCs and one hundred twenty seven were FDPs. Of these three hundred ninety seven implant-supported reconstructions, 18 had failed, yielding a failure rate of 4.5% and a survival rate of 95.5% after a mean observation period of 10.75 years (range: 8.4-13.5 years). The most frequent complication was ceramic chipping (20.31%) followed by occlusal screw loosening (2.57%) and loss of retention (2.06%). No occlusal screw fracture, one abutment loosening, and two abutment fractures were noted. This resulted in a total mechanical/technical complication rate of 24.7%. The prosthetic success rate over a mean follow-up time of 10.75 years was 70.8%. Generalized attrition and FDPs were associated with statistically significantly higher rates of ceramic fractures when compared with SCs. Cantilever extensions, screw retention, anterior versus posterior, and gender did not influence the chipping rate. CONCLUSIONS After a mean exposure time of 10.75 years, high survival rates for reconstructions supported by Sand-blasted Large-grit Acid-etched implants can be expected. Ceramic chipping was the most frequent complication and was increased in dentitions with attrition and in FDPs compared with SCs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to review our experience with laparoscopic end colostomy closure. A retrospective review of a prospectively entered database was performed. Proportions and continuous variables were compared using the Fisher's exact and the Mann-Whitney U tests, respectively. Within the study period, 53 patients underwent closure of end colostomies. The main reasons for the colonic resections were perforated diverticulitis (52.7%) and neoplasms (20.8%). In 28 patients (53%), laparoscopic closure (LC) was attempted. Demographics did not differ between the attempted LC and the primary open closure (OC) group. The conversion rate from an LC to an OC was 50 per cent (14 of 28), mostly as a result of adhesions (71.4%). Hospital length of stay (HLOS) was significantly longer for the OC than with the attempted LC group (15.4 ± 11.9 days vs 11.3 ± 8.5 days, P = 0.046). The overall complication rate was not different between the completed LC and the OC groups (43 vs 56%, P = 0.634). The majority of complications detected (91.1%) were minor and could be treated conservatively. The role of laparoscopy to close end colostomies is questionable, because the conversion rate is high. However, a shorter HLOS can be expected when laparoscopy is successful. To reduce morbidity resulting from prolonged operation times, it is crucial to convert early and pre-emptively if hostile adhesions are found.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To assess the 5-year survival of metal-ceramic and all-ceramic tooth-supported single crowns (SCs) and to describe the incidence of biological, technical and esthetic complications. METHODS Medline (PubMed), Embase, Cochrane Central Register of Controlled Trials (CENTRAL) searches (2006-2013) were performed for clinical studies focusing on tooth-supported fixed dental prostheses (FDPs) with a mean follow-up of at least 3 years. This was complimented by an additional hand search and the inclusion of 34 studies from a previous systematic review [1,2]. Survival and complication rates were analyzed using robust Poisson's regression models to obtain summary estimates of 5-year proportions. RESULTS Sixty-seven studies reporting on 4663 metal-ceramic and 9434 all-ceramic SCs fulfilled the inclusion criteria. Seventeen studies reported on metal-ceramic crowns, and 54 studies reported on all-ceramic crowns. Meta-analysis of the included studies indicated an estimated survival rate of metal-ceramic SCs of 94.7% (95% CI: 94.1-96.9%) after 5 years. This was similar to the estimated 5-year survival rate of leucit or lithium-disilicate reinforced glass ceramic SCs (96.6%; 95% CI: 94.9-96.7%), of glass infiltrated alumina SCs (94.6%; 95% CI: 92.7-96%) and densely sintered alumina and zirconia SCs (96%; 95% CI: 93.8-97.5%; 92.1%; 95% CI: 82.8-95.6%). In contrast, the 5-year survival rates of feldspathic/silica-based ceramic crowns were lower (p<0.001). When the outcomes in anterior and posterior regions were compared feldspathic/silica-based ceramic and zirconia crowns exhibited significantly lower survival rates in the posterior region (p<0.0001), the other crown types performed similarly. Densely sintered zirconia SCs were more frequently lost due to veneering ceramic fractures than metal-ceramic SCs (p<0.001), and had significantly more loss of retention (p<0.001). In total higher 5 year rates of framework fracture were reported for the all-ceramic SCs than for metal-ceramic SCs. CONCLUSIONS Survival rates of most types of all-ceramic SCs were similar to those reported for metal-ceramic SCs, both in anterior and posterior regions. Weaker feldspathic/silica-based ceramics should be limited to applications in the anterior region. Zirconia-based SCs should not be considered as primary option due to their high incidence of technical problems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES Megacystis (MC) is rare and often associated with other structural and chromosomal anomalies. In euploid cases with early oligohydramnios, prognosis is poor mainly due to pulmonary hypoplasia and renal damage. We report our experience of the past 20 years. METHODS A retrospective review of cases with prenatally diagnosed MC was performed. Complete prenatal as well as postnatal medical records from 1989 to 2009 were reviewed focusing on diagnostic precision, fetal interventions [vesicocentesis (VC), vesicoamniotic shunt (VAS)], short- and long-term outcome, and potential prognostic factors. RESULTS 68 cases were included. Follow-up was available in 54 cases (9 girls and 45 boys including 3 cases with aneuploidy). We found 39 isolated MC at sonography (5 girls and 34 boys). 24 fetuses with isolated MC underwent VC and VAS at 19.6 ± 6.3 and 20 ± 4.9 weeks of gestation, respectively. Survival rate was higher in male than in female fetuses (51 vs. 33%). Renal problems occurred in 4/14 prenatally treated fetuses and in 1/10 when cases with prune belly syndrome (PBS) were excluded from the analysis. CONCLUSIONS Our study shows that a careful selection of cases with MC excluding fetuses with PBS and early treatment has still the potential to improve outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Efficiently performed basic life support (BLS) after cardiac arrest is proven to be effective. However, cardiopulmonary resuscitation (CPR) is strenuous and rescuers' performance declines rapidly over time. Audio-visual feedback devices reporting CPR quality may prevent this decline. We aimed to investigate the effect of various CPR feedback devices on CPR quality. METHODS In this open, prospective, randomised, controlled trial we compared three CPR feedback devices (PocketCPR, CPRmeter, iPhone app PocketCPR) with standard BLS without feedback in a simulated scenario. 240 trained medical students performed single rescuer BLS on a manikin for 8min. Effective compression (compressions with correct depth, pressure point and sufficient decompression) as well as compression rate, flow time fraction and ventilation parameters were compared between the four groups. RESULTS Study participants using the PocketCPR performed 17±19% effective compressions compared to 32±28% with CPRmeter, 25±27% with the iPhone app PocketCPR, and 35±30% applying standard BLS (PocketCPR vs. CPRmeter p=0.007, PocketCPR vs. standard BLS p=0.001, others: ns). PocketCPR and CPRmeter prevented a decline in effective compression over time, but overall performance in the PocketCPR group was considerably inferior to standard BLS. Compression depth and rate were within the range recommended in the guidelines in all groups. CONCLUSION While we found differences between the investigated CPR feedback devices, overall BLS quality was suboptimal in all groups. Surprisingly, effective compression was not improved by any CPR feedback device compared to standard BLS. All feedback devices caused substantial delay in starting CPR, which may worsen outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The copy number variation (CNV) in beta-defensin genes (DEFB) on human chromosome 8p23 has been proposed to contribute to the phenotypic differences in inflammatory diseases. However, determination of exact DEFB CN is a major challenge in association studies. Quantitative real-time PCR (qPCR), paralog ratio tests (PRT) and multiplex ligation-dependent probe amplification (MLPA) have been extensively used to determine DEFB CN in different laboratories, but inter-method inconsistencies were observed frequently. In this study we asked which one is superior among the three methods for DEFB CN determination. RESULTS We developed a clustering approach for MLPA and PRT to statistically correlate data from a single experiment. Then we compared qPCR, a newly designed PRT and MLPA for DEFB CN determination in 285 DNA samples. We found MLPA had the best convergence and clustering results of the raw data and the highest call rate. In addition, the concordance rates between MLPA or PRT and qPCR (32.12% and 37.99%, respectively) were unacceptably low with underestimated CN by qPCR. Concordance rate between MLPA and PRT (90.52%) was high but PRT systematically underestimated CN by one in a subset of samples. In these samples a sequence variant which caused complete PCR dropout of the respective DEFB cluster copies was found in one primer binding site of one of the targeted paralogous pseudogenes. CONCLUSION MLPA is superior to PRT and even more to qPCR for DEFB CN determination. Although the applied PRT provides in most cases reliable results, such a test is particularly sensitive to low-frequency sequence variations preferably accumulating in loci like pseudogenes which are most likely not under selective pressure. In the light of the superior performance of multiplex assays, the drawbacks of such single PRTs could be overcome by combining more test markers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The abundant production of in situ cosmogenic 36Cl from potassium renders 36Cl measurements in K-rich rocks or minerals, such as K-feldspars, potentially useful for precisely dating rock surfaces, either in single-nuclide or in multi-nuclide studies, for example combined with 10Be measurements in quartz. However, significant discrepancies in experimentally calibrated 36Cl production rates from spallation of potassium (36PK-sp), referenced to sea-level/high-latitude (SLHL), limit the accuracy of 36Cl dating from K-rich lithologies. We present a new 36Cl calibration using K-feldspars, in which K-spallation is the most dominant 36Cl production pathway (>92% of total 36Cl), thus minimizing uncertainties from the complex multi-pathway 36Cl production systematics. The samples are derived from boulders of an ∼13.4 ka-old landslide in the Swiss Alps (∼820 m, 46.43°N, 8.85°E). We obtain a local 36PK-sp of 306 ± 16 atoms 36Cl (g K)−1 a−1 and an SLHL 36PK-sp of 145.5 ± 7.7 atoms 36Cl (g K)−1 a−1, when scaled with a standard scaling protocol (‘Lm’). Applying this SLHL 36PK-sp to determine 36Cl exposure ages of K-feldspars from 10Be-dated moraine boulders yields excellent agreement, confirming the validity of the new SLHL 36PK-sp for surface exposure studies, involving 36Cl in K-feldspars, in the Alps.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION The pentasaccharide fondaparinux is widely approved for prophylaxis and treatment of thromboembolic diseases and therapy of acute coronary syndrome. It is also used off-label in patients with acute, suspected or antecedent heparin-induced thrombocytopenia (HIT). The aim of this prospective observational cohort study was to document fondaparinux' prescription practice, tolerance and therapy safety in a representative mixed German single-centre patient cohort. PATIENTS AND METHODS Between 09/2008 - 04/2009, 231 consecutive patients treated with fondaparinux were enrolled. Medical data were obtained from patient's records. The patients were clinically screened for thrombosis (Wells score), sequelae of HIT (4T's score), and bleeding complications (ISTH-criteria) and subjected to further assessment (i.e. sonography, HIT-diagnostics), if necessary. The mortality rate was assessed 30 days after therapy start. RESULTS Overall, 153/231 patients had a prophylactic, 74/231 patients a therapeutic, and 4/231 patients a successive prophylactic/therapeutic indication. In 11/231 patients fondaparinux was used due to suspected/antecedent HIT, in 5/231 patients due to a previous cutaneous delayed-type hypersensitivity to heparins. Other indications were rare. Three new/progressive thromboses were detected. No cases of HIT, major bleedings, or fatalities occurred. CONCLUSIONS Fondaparinux was well tolerated and was safe in prophylaxis and therapy; prescriptions mostly followed the current approval guidelines and were rarely related to HIT-associated indications (<5% of prescriptions), which is in contrast to previous study results in the U.S. (>94% of prescriptions were HIT-associated). A trend towards an individualised fondaparinux use based on the compound's inherent properties and the patients' risk profiles, i.e., antecedent HIT, bone fractures, heparin allergy, was observed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Catheter ablation of complex fractionated atrial electrograms (CFAE), also known as defragmentation ablation, may be considered for the treatment of persistent atrial fibrillation (AF) beyond pulmonary vein isolation (PVI). Concomitant antiarrhythmic drug (AAD) therapy is common, but the relevance of AAD administration and its optimal timing during ablation remain unclear. Therefore, we investigated the use and timing of AADs during defragmentation ablation and their possible implications for AF termination and ablation success in a large cohort of patients. Retrospectively, we included 200 consecutive patients (age: 61 ± 12 years, LA diameter: 47 ± 8 mm) with persistent AF (episode duration 47 ± 72 weeks) who underwent de novo ablation including CFAE ablation. In all patients, PVI was performed prior to CFAE ablation. The use and timing of AADs were registered. The follow-ups consisted of Holter ECGs and clinical visits. Termination of AF was achieved in 132 patients (66 %). Intraprocedural AADs were administered in 168/200 patients (84 %) 45 ± 27 min after completion of PVI. Amiodarone was used in the majority of the patients (160/168). The timing of AAD administration was predicted by the atrial fibrillation cycle length (AFCL). At follow-up, 88 patients (46 %) were free from atrial arrhythmia. Multivariate logistic regression analysis revealed that administration of AAD early after PVI, LA size, duration of AF history, sex and AFCL were predictors of AF termination. The administration of AAD and its timing were not predictive of outcome, and age was the sole independent predictor of AF recurrence. The administration of AAD during ablation was common in this large cohort of persistent AF patients. The choice to administer AAD therapy and the timing of the administration during ablation were influenced by AFCL, and these factors did not significantly influence the moderate single procedure success rate in this retrospective analysis.