946 resultados para Sewage Effluent
Resumo:
The hydrogen gas is regarded as clean and renewable energy source, since it generates only water during combustion when used as fuel. It shows 2.75 times more energy content than any hydrocarbon and it can be converted into electrical, mechanical energy or heat. Inoculum sources have been successfully tested for hydrogen biological production in temperate climate countries as sludge treatment plants sewage, sludge treatment plant wastewater, landfill sample, among others. However, hydrogen biologic production with inoculum from environmental samples such as sediment reservoirs, especially in tropical countries like Brazil, is rarely investigated. Reservoirs and fresh water lake sediment may contain conditions for the survival of a wide variety of microorganisms which use different carbon sources mainly glucose and xylose, in the fermentation. Glucose is an easily biodegradable, present in most of the industrial effluents and can be obtained abundantly from agricultural wastes. A wide variety of wastewater resulting from agriculture, industry and pulp and paper processed from wood may contain xylose in its constitution. Such effluent contains glucose and xylose concentrations of about 2 g/L. In this sense, this work verified hydrogen biological production in anaerobic batch reactor (1L), at 37 ° C, initial pH 5.5, headspace with N2 (100%), Del Nery medium, vitamins and peptone (1 g/L), fed separately with glucose (2g/L) and xylose (2 g/L). The inoculum was taken from environmental sample (sediment reservoir Itupararanga - Ibiúna - SP-Brazil). It was previously purified in serial dilutions at H2 generation (10-5, 10-7, 10-10), and heat treated (90º C - 10 min) later to inhibited the H2 consumers. The maximum H2 generations obtained in both tests were observed at 552 h, as described below. At the reactors fed with glucose and xylose were observed, respectively, 9.1 and 8.6 mmol H2/L, biomass growth (0.2 and 0.2 nm); consumption of sugar concentrations 53.6% (1.1 glucose g/L) and 90.5% (1.8 xylose g/L); acetic acid generation (124.7 mg/L and 82.7 mg/L), butyric acid (134.0 mg/L and 230.4 mg/L) and there wasn’t methane generation in the reactors. Microscopic analysis of biomass in anaerobic reactors showed the predominance of Gram positive rods and rods with endospores, whose morphology is characteristic of H2-generating bacteria, in both tests. These species were selected from the natural environment. In DGGE analysis performed difference were observed between populations from inoculum and in tests. This analysis confirmed that some species of bacteria were selected which remained under the conditions imposed on the experiment. The efficiency of the pre-treatment of inoculum and the imposition of pH 5.5 inhibited methane-producing microorganisms and the consumers of H2. Therefore, the experimental conditions imposed allowed the attainment of bacterial consortium of producer H2 taken from an environmental sample with concentration of xylose and glucose similar to the ones of the industrial effluents.
Resumo:
Pós-graduação em Engenharia Civil - FEIS
Resumo:
Pós-graduação em Química - IQ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This research studied the sequential ozone and chlorine process with respect to, the inactivation of indicator bacteria and the formation of ozone disinfection byproducts in sanitary wastewater effluent. The applied ozone doses were 5, 8 and 10 mg.O3.L(-1), followed by chlorine doses of 10, 20 and 30 mg.L(-1), respectively. After the sequential ozone/chlorine process, the mean reduction in chemical oxygen demand ranged from 9 to 37%. Total coliform inactivation ranged from 1.59 to 3.73 log10, and E. coli was always <1 CFU 100 mL(-1). Ozonation resulted in the formation of aldehydes, which were not significantly impacted by the subsequent chlorine dose (P ≤ 0.05).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The study took place in a sewage treatment plant located at the actual Department of Water and Sewer in Bauru, city of Sao Paulo state. This treatment plant has an average entrance flow of 4.8 l. s-1 made by upflow anaerobic filter, followed by wetland systems constructed in parallel. . As objective of this study we evaluate the effectiveness of three systems of constructed wetlands, with three different types of plants (Lily pond, Giant papyrus and Cattail),quantify, and qualify the effluents at various stages of treatment to monitor their effectiveness and the possibility of reuse in agriculture. There was a satisfactory removal of organic matter, with a mean concentration of 36 and 39mg.l-1 at the , phases 1 and 2 of the operation, respectively. The constructed wetlands effluent nitrogen and phosphate concentrations were high throughout all the system and the removal efficiency of ammonia nitrogen was much lower than expected, then the system is functioning as secondary treatment and not as tertiary treatment. The concentrations of micro-organisms found in the final effluent were also high. Therefore, it is concluded that the results of removal efficiency of organic matter, of constructed wetland systems, meet the parameters required by legislation for effluent discharges but do not attend the parameters required for nitrogen and micro organisms. This way, these analyzed plants effluents are suitable for reuse in agriculture restricted irrigation
Resumo:
This paper has the objective of monitoring the biological activity of composting process of sewage sludge, sugarcane bagasse and ground coffee in a hermetic rotary reactor using the respirometric method in laboratory scale, in order to obtain parameters and system design for large scale projects. Another particularity of this study is the use of a hermetic reactor with gas purging cycles. Purging was performed when the percentage of oxygen reached less than 5%, thus eliminating the gaseous mixture (with elevated CO2 ratio) and the introduction of environmental air with around 21% of O2, successively until the compost was stabilized. The average purge intervals obtained were 29 h and 2 min with reactor rotation frequency of 15 min. The time of the compost stabilization was optimized in 60% if compared to the 90 days in the traditional method. The results obtained can be used to design the process in industrial scale using a simple O2 gas analyzer.
Resumo:
Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA
Resumo:
Cintra stream is the major receiver of treated effluent from sanitary, hospital and research laboratory sewage from the UNESP campus in Botucatu, Rubião Júnior District, São Paulo state; and it has shown evidence of diffuse contamination by metals along it. Analyses of the most toxic metals (Pb, Cu, Fe, Ni and Zn) were carried out by using an atomic absorption spectrometer AA-6.800 - Perkin Elmer, analyst 700. ANOVA followed by the Tukey test were used for data analyses at 5% significance level. The main objective of this study was to compare current data on metal levels with data from other studies, in the same area, and of the same nature, conducted before and after implementation of chemical residue management by the university in 2008. Also, it aimed at identifying and quantifying possible diffuse and punctual contamination. Sites S1 and S2 showed punctual contamination, while diffuse sources were observed between S4 and S5. The quality of water in the Cintra Stream improved after establishment of the program of laboratory chemical residue management in the Campus of UNESP.
Resumo:
When the well "goes dry" or when the windmill or pump breaks down, every one in the household immediately appreciates the value fo plenty of water. In other words, "You never miss the water until the well runs dry." Fortunately, in most sections of this state, plenty of pure water may be obtained by sinking wells of moderate depth, yet surprisingly few farm homes are supplied with running water in the kitchen even though the barn yards are equipped with hydrants and tanks. It is the purpose of this bulletin to present a number of water supply and sewage disposal systems which have been used in Nebraska and surrounding states and which add greatly to the comfort and convenience of the farm home.
Resumo:
Sediments from Admiralty Bay, Antarctica were collected during the austral summers of 2002/2003 and 2003/2004 in order to assess the distribution and concentration of sewage indicators originating from Comandante Ferraz Brazilian Antarctic Station. Fecal sterols (coprostanol + epicoprostanol) and linear alkylbenzenes (LABs) ranged from <0.01 to 0.95 mu g g(-1) and <1.0 to 23 ng g(-1) dry weight, respectively. In general, the higher concentrations were found only locally in the vicinity of Ferraz station at Martel Inlet. Baseline values for fecal sterols and coprostanone were calculated as 0.19 and 0.40 mu g g(-1), respectively. According to fecal sterols concentrations, sewage contribution to Martel Inlet has increased more than twice since 1997, as result of the increase in the number of researchers at the station especially during the last decade. A low correlation was found between total LABs and fecal steroids, which could be attributed to the contribution of the natural sources of steroids. (C) 2010 Elsevier B.V. All rights reserved.