998 resultados para Safety Device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Pathogen reduction of platelets (PRT-PLTs) using riboflavin and ultraviolet light treatment has undergone Phase 1 and 2 studies examining efficacy and safety. This randomized controlled clinical trial (RCT) assessed the efficacy and safety of PRT-PLTs using the 1-hour corrected count increment (CCI(1hour) ) as the primary outcome. STUDY DESIGN AND METHODS: A noninferiority RCT was performed where patients with chemotherapy-induced thrombocytopenia (six centers) were randomly allocated to receive PRT-PLTs (Mirasol PRT, CaridianBCT Biotechnologies) or reference platelet (PLT) products. The treatment period was 28 days followed by a 28-day follow-up (safety) period. The primary outcome was the CCI(1hour) determined using up to the first eight on-protocol PLT transfusions given during the treatment period. RESULTS: A total of 118 patients were randomly assigned (60 to PRT-PLTs; 58 to reference). Four patients per group did not require PLT transfusions leaving 110 patients in the analysis (56 PRT-PLTs; 54 reference). A total of 541 on-protocol PLT transfusions were given (303 PRT-PLTs; 238 reference). The least square mean CCI was 11,725 (standard error [SE], 1.140) for PRT-PLTs and 16,939 (SE, 1.149) for the reference group (difference, -5214; 95% confidence interval, -7542 to -2887; p<0.0001 for a test of the null hypothesis of no difference between the two groups). CONCLUSION: The study failed to show noninferiority of PRT-PLTs based on predefined CCI criteria. PLT and red blood cell utilization in the two groups was not significantly different suggesting that the slightly lower CCIs (PRT-PLTs) did not increase blood product utilization. Safety data showed similar findings in the two groups. Further studies are required to determine if the lower CCI observed with PRT-PLTs translates into an increased risk of bleeding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: In order to improve safety of pedicle screw placement several techniques have been developed. More recently robotically assisted pedicle insertion has been introduced aiming at increasing accuracy. The aim of this study was to compare this new technique with the two main pedicle insertion techniques in our unit namely fluoroscopically assisted vs EMG aided insertion. Material and methods: A total of 382 screws (78 thoracic,304 lumbar) were introduced in 64 patients (m/f = 1.37, equally distributed between insertion technique groups) by a single experienced spinal surgeon. From those, 64 (10 thoracic, 54 lumbar) were introduced in 11 patients using a miniature robotic device based on pre operative CT images under fluoroscopic control. 142 (4 thoracic, 138 lumbar) screws were introduced using lateral fluoroscopy in 27 patients while 176 (64 thoracic, 112 lumbar) screws in 26 patients were inserted using both fluoroscopy and EMG monitoring. There was no difference in the distribution of scoliotic spines between the 3 groups (n = 13). Screw position was assessed by an independent observer on CTs in axial, sagittal and coronal planes using the Rampersaud A to D classification. Data of lumbar and thoracic screws were processed separately as well as data obtained from axial, sagittal and coronal CT planes. Results: Intra- and interobserver reliability of the Rampersaud classification was moderate, (0.35 and 0.45 respectively) being the least good on axial plane. The total number of misplaced screws (C&D grades) was generally low (12 thoracic and 12 lumbar screws). Misplacement rates were same in straight and scoliotic spines. The only difference in misplacement rates was observed on axial and coronal images in the EMG assisted thoracic screw group with a higher proportion of C or D grades (p <0.05) in that group. Recorded compound muscle action potentials (CMAP) values of the inserted screws were 30.4 mA for the robot and 24.9mA for the freehand technique with a CI of 3.8 of the mean difference of 5.5 mA. Discussion: Robotic placement did improve the placement of thoracic screws but not that of lumbar screws possibly because our misplacement rates in general near that of published navigation series. Robotically assisted spine surgery might therefore enhance the safety of screw placement in particular in training settings were different users at various stages of their learning curve are involved in pedicle instrumentation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cilengitide is a selective integrin inhibitor that is well tolerated and has demonstrated biologic activity in patients with recurrent malignant glioma. The primary objectives of this randomized phase 2 trial were to determine the safety and efficacy of cilengitide when combined with radiation and temozolomide for patients with newly diagnosed glioblastoma multiforme and to select a dose for comparative clinical testing. METHODS: In total, 112 patients were accrued. Eighteen patients received standard radiation and temozolomide with cilengitide in a safety run-in phase followed by a randomized phase 2 trial with 94 patients assigned to either a 500 mg dose group or 2000 mg dose group. The trial was designed to estimate overall survival benefit compared with a New Approaches to Brain Tumor Therapy (NABTT) Consortium internal historic control and data from the published European Organization for Research and Treatment of Cancer (EORTC) trial EORTC 26981. RESULTS: Cilengitide at all doses studied was well tolerated with radiation and temozolomide. The median survival was 19.7 months for all patients, 17.4 months for the patients in the 500 mg dose group, 20.8 months for patients in the 2000 mg dose group, 30 months for patients who had methylated O6-methylguanine-DNA methyltransferase (MGMT) status, and 17.4 months for patients who had unmethylated MGMT status. For patients aged ≤70 years, the median survival and survival at 24 months was superior to what was observed in the EORTC trial (20.7 months vs 14.6 months and 41% vs 27%, respectively; P = .008). CONCLUSIONS: Cilengitide was well tolerated when combined with standard chemoradiation and may improve survival for patients newly diagnosed with glioblastoma multiforme regardless of MGMT methylation status. The authors concluded that, from an efficacy and safety standpoint, future trials of this agent in this population should use the 2000 mg dose. Cancer 2012. © 2012 American Cancer Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The RCP is a 14 French collapsable percutaneous cardiovascular support device positioned in the descending part of the thoracic aorta via the femoral artery. A 10 patient first in man study demonstrated device safety and significant improvement in renal function among high risk PCI patients. We now report haemodynamic and renal efficacy in patients with ADHF.Methods: Prospective non randomised study seeking to recruit 20 patients with ADHF with a need for inotropic or mechanical circulatory support with: i) EF < 30% ii)Cardiac index(CI) < 2.2 L / min / m2 Outcome measures included: 1) Cardiac index (CI) 2) Pulmonary Capillary Wedge Pressure (PCWP) 3) Urine output / serum creatinine 4) Vascular / device complications 5) 30 day mortalityResults: INTERIM ANALYSIS (n=12) The mean age of the study group was 64 years, with a mean baseline creatinine of 193 umol/L, eGFR 38 ml/min. The intended RCP treatment period was 24 hours. During RCP treatment there was a significant mean reduction of PCWP at 4 hours of 17% (25 to 21 mmHg p=0.04). Mean CI increased at 12 hours by 11%, though not reaching significance (1.78 to 1.96 L/min/m2 p=0.08). RCP insertion prompted substantial diuresis. Urine output tripled over the first 12 hours compared to baseline (55 ml/hr vs 213 ml/hr p=0.03). This was associated with significantly improved renal function, a 28% reduction in serum creatinine at 12 hours (193 to 151 umol/L p=0.003), and a increase in eGFR from 38 ml/min to 50 ml/min (p=0.0007). 2 patients previously refused cardiac transplantation were reassessed and successfully transplanted within 9 months of RCP treatment on the basis of demonstrable renal reversibility. There were no vascular or device complications. There were 2 deaths at 30 days, one from multi-organ failure and sepsis, and one from intractable heart failure - neither were device related.Conclusion: RCP support in ADHF patients was associated with improved haemodynamics, and an improvement in renal function. The Reitan Catheter Pump may have a role in providing percutaneous cardiovascular and renal support in the acutely decompensated cardiac patient, and may have a role in suggesting renal reversibility in potential cardiac transplant patients. Further data will be reported at recruitment completion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ventricular assist devices (VADs) are used in treatment for terminal heart failure or as a bridge to transplantation. We created biVAD using the artificial muscles (AMs) that supports both ventricles at the same time. We developed the test bench (TB) as the in vitro evaluating system to enable the measurement of performance. The biVAD exerts different pressure between left and right ventricle like the heart physiologically does. The heart model based on child's heart was constructed in silicone. This model was fitted with the biVAD. Two pipettes containing water with an ultrasonic sensor placed on top of each and attached to ventricles reproduced the preload and the after load of each ventricle by the real-time measurement of the fluid height variation proportionally to the exerted pressure. The LabVIEW software extrapolated the displaced volume and the pressure generated by each side of our biVAD. The development of a standardized protocol permitted the validation of the TB for in vitro evaluation, measurement of the performances of the AM biVAD herein, and reproducibility of data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Direct electrical stimulation of the colon offers a promising approach for the induction of propulsive colonic contractions by using an implantable device. The objective of this study was to assess the feasibility to induce colonic contractions using a commercially available battery-operated stimulator (maximum pulse width of 1 ms and maximum amplitude of 10 V). Three pairs of pacing electrodes were inserted into the cecal seromuscular layer of anesthetized pigs. During a first set of in vivo experiments conducted on six animals, a pacing protocol leading to cecum contractions was determined: stimulation bursts with 1 ms pulse width, 10 V amplitude (7-15 mA), 120 Hz frequency, and 30-s burst duration, repeated every 2-5 min. In a second testing phase, an evaluation of the pacing protocol was performed in four animals (120 stimulation bursts in total). By using the battery-operated stimulator, contractions of the cecum and movement of contents could be induced in 92% of all stimulations. A cecal shortening of about 30% and an average intraluminal pressure increase of 10.0 +/- 6.0 mmHg were observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To start off, this document describes the Catalan model for emergencies response and its reference frame in terms of geography, location population…In addition, describes the main actors involved in emergencies response such as: police, the Fire and Rescue Emergency Service, the Emergency Medical System, Civil Protection, Reception and Management of Emergency Calls, Rural Agents, ADF’s and UME. Civil Protection, Firefighters and Police are includes in the training model developed by the Institute for Public Safety of Catalonia which at the same time does research in both security and safety matters. Research activities are performed by the Area for Research, Knowledge and International Cooperation at the ISPC and an example of these activities are European Research Projects such as COIM-Best (Coordination Improvement by Best Practices) and BESECU (cross-cultural differences of human behaviour in fire disasters and other crisis situations) among others.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Road Safety Authority has responsibility for co-ordinating the development of Ireland’s Road Safety Strategy.  The Government’s road safety target of no more than 252 deaths per annum by the end of 2012 was achieved in 2009, when the number of road collision deaths in Ireland fell to 239.  The reduction in the number of fatalities was achieved through robust actions in terms of education and awareness, road engineering, and enforcement, including significant legislative milestones.  The challenge is now to ensure that the impact of these measures on collision levels is sustained and enhanced into the future through continuous education, enforcement and road engineering measures and initiatives. IPH welcomes the opportunity to respond to this consultation given the significant burden of injury, disability and mortality associated with road traffic collisions on the island of Ireland.  IPH supports the development of evidence-based strategies and actions which can maintain a transport system, in which the safety of all road users is paramount. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Department of Environment (NI)  recently held a consultation on preparing a new road safety strategy for Northern Ireland which will cover the years 2010 to 2020.  The consultation ran from 16 March 2010 to 15 June 2010.  The consultation paper outlined key challenges to be addressed over the lifetime of the strategy and proposed a number of action measures which have been agreed by the statutory road safety partners.  Views were invited on preparing a new road safety strategy for Northern Ireland that will shape the way ahead for safety on roads over the next decade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Natural Orifice Transluminal Endoscopic Surgery (NOTES) is a novel, potentially less invasive alternative to laparoscopic surgery. However, the problems of transluminal access and closure represent significant obstacles to its successful introduction in humans. Objective: to evaluate the feasibility and safety of a novel device designed for transluminal access and closure in a survival porcine model. Subjects: Four adult female Yorkshire pigs were used in the study. Interventions: While under general anesthesia, the animals were prepared with multiple tap water enemas followed by instillation of an antibiotic suspension and povidone-iodine lavage. At a distance of 15 to 20 cm from the anus, the prototype device (LSI Solutions, Victor, NY, USA) deployed a circumscribing purse-string suture around the planned incision site and subsequently used a blade mechanism to create a 2.5-cm linear incision. The transcolonic incision was then closed by cinching and securing the purse-string suture with a titanium knot by use of a separate hand-activated suture-locking device. Main Outcome Measurements: The animals were monitored daily for signs of peritonitis and sepsis and were survived for 14 days. The peritoneal cavity was examined for peritonitis, and the colonic incision site was examined for wound dehiscence, pericolic abscess formation, and gross adhesions. Tissue samples from both incisional and random peritoneal sites were obtained for histologic examination. Results: Transcolonic incision and closure were successful in all 4 animals. The device performed in a rapid and reproducible fashion. All animals recovered without septic complications. At necropsy, there was no evidence of peritonitis, abscesses, or wound dehiscence. Salpingocolonic and colovesicular adhesions were noted in 3 of 4 animals. Histologic examination revealed microabscesses at the incision site in all animals. Conclusions: The prototype incision and closure device represents a promising solution to the problems of transluminal access for NOTES. The presence of incision-related adhesions and microabscesses signal the need for further refinement in aseptic technique.