936 resultados para Repetitive-element-based PCR assays


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Infections of the central nervous systems (CNS) present a diagnostic problem for which an accurate laboratory diagnosis is essential. Invasive practices, such as cerebral biopsy, have been replaced by obtaining a polymerase chain reaction (PCR) diagnosis using cerebral spinal fluid (CSF) as a reference method. Tests on DNA extracted from plasma are noninvasive, thus avoiding all of the collateral effects and patient risks associated with CSF collection. This study aimed to determine whether plasma can replace CSF in nested PCR analysis for the detection of CNS human herpesvirus (HHV) diseases by analysing the proportion of patients whose CSF nested PCR results were positive for CNS HHV who also had the same organism identified by plasma nested PCR. In this study, CSF DNA was used as the gold standard, and nested PCR was performed on both types of samples. Fifty-two patients with symptoms of nervous system infection were submitted to CSF and blood collection. For the eight HHV, one positive DNA result-in plasma and/or CSF nested PCR-was considered an active HHV infection, whereas the occurrence of two or more HHVs in the same sample was considered a coinfection. HHV infections were positively detected in 27/52 (51.9%) of the CSF and in 32/52 (61.5%) of the plasma, difference not significant, thus nested PCR can be performed on plasma instead of CSF. In conclusion, this findings suggest that plasma as a useful material for the diagnosis of cases where there is any difficulty to perform a CSF puncture.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Hepatitis C virus (HCV) genotyping is the most significant predictor of the response to antiviral therapy. The aim of this study was to develop and evaluate a novel real-time PCR method for HCV genotyping based on the NS5B region. Methodology/Principal Findings: Two triplex reaction sets were designed, one to detect genotypes 1a, 1b and 3a; and another to detect genotypes 2a, 2b, and 2c. This approach had an overall sensitivity of 97.0%, detecting 295 of the 304 tested samples. All samples genotyped by real-time PCR had the same type that was assigned using LiPA version 1 (Line in Probe Assay). Although LiPA v. 1 was not able to subtype 68 of the 295 samples (23.0%) and rendered different subtype results from those assigned by real-time PCR for 12/295 samples (4.0%), NS5B sequencing and real-time PCR results agreed in all 146 tested cases. Analytical sensitivity of the real-time PCR assay was determined by end-point dilution of the 5000 IU/ml member of the OptiQuant HCV RNA panel. The lower limit of detection was estimated to be 125 IU/ml for genotype 3a, 250 IU/ml for genotypes 1b and 2b, and 500 IU/ml for genotype 1a. Conclusions/Significance: The total time required for performing this assay was two hours, compared to four hours required for LiPA v. 1 after PCR-amplification. Furthermore, the estimated reaction cost was nine times lower than that of available commercial methods in Brazil. Thus, we have developed an efficient, feasible, and affordable method for HCV genotype identification.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Restriction fragment length polymorphism (RFLP) is a common molecular assay used for genotyping, and it requires validated quality control procedures to prevent mistyping caused by impaired endonuclease activity. We have evaluated the usefulness of a plasmid-based internal control in RFLP assays. Results: Blood samples were collected from 102 individuals with acute myocardial infarction (AMI) and 108 non-AMI individuals (controls) for DNA extraction and laboratory analyses. The 1196C> T polymorphism in the toll-like receptor 4 (TLR4) gene was amplified by mismatched-polymerase chain reaction (PCR). Amplicons and pBluescript II SK-plasmid were simultaneously digested with endonuclease HincII. Fragments were separated on 2% agarose gels. Plasmid was completely digested using up to 55.2 nmL/L DNA solutions and 1 mu L PCR product. Nevertheless, plasmid DNA with 41.4 nM or higher concentrations was incompletely digested in the presence of 7 mL PCR product. In standardized conditions, TLR4 1196C> T variant was accurately genotyped. TLR4 1196T allele frequency was similar between AMI (3.1%) and controls (2.0%, p = 0.948). TLR4 SNP was not associated with AMI in this sample population. In conclusion, the plasmid-based control is a useful approach to prevent mistyping in RFLP assays, and it is validate for genetic association studies such as TLR4 1196C> T.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Modern lifestyle markedly changed eating habits worldwide, with an increasing demand for ready-to-eat foods, such as minimally processed fruits and leafy greens. Packaging and storage conditions of those products may favor the growth of psychrotrophic bacteria, including the pathogen Listeria monocytogenes. In this work, minimally processed leafy vegetables samples (n = 162) from retail market from Ribeirao Preto, Sao Paulo, Brazil, were tested for the presence or absence of Listeria spp. by the immunoassay Listeria Rapid Test, Oxoid. Two L. monocytogenes positive and six artificially contaminated samples of minimally processed leafy vegetables were evaluated by the Most Probable Number (MPN) with detection by classical culture method and also culture method combined with real-time PCR (RTi-PCR) for 16S rRNA genes of L monocytogenes. Positive MPN enrichment tubes were analyzed by RTi-PCR with primers specific for L. monocytogenes using the commercial preparation ABSOLUTET (TM) QPCR SYBR (R) Green Mix (ABgene, UK). Real-time PCR assay presented good exclusivity and inclusivity results and no statistical significant difference was found in comparison with the conventional culture method (p < 0.05). Moreover, RTi-PCR was fist and easy to perform, with MPN results obtained in ca. 48 h for RTi-PCR in comparison to 7 days for conventional method. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aim: Unless specifically treated (glucocorticoids in low doses), Familial Hyperaldosteronism Type I(FH-I) may result in early death from stroke. We report the successful application of a rapid, polymerase chain reaction (PCR)-based method of detecting the 'hybrid' 11 beta-hydroxylase (11 beta-OHase)/aldosterone synthase (AS) gene as a screening test for FH-I. Methods: 'Long-PCR' was used to amplify, concurrently, a 4 kb fragment of AS gene (both primers AS-specific) and a 4 kb fragment of the hybrid gene (5' primer 11 beta-OHase-specific, 3'primer AS-specific) from DNA extracted from blood either collected locally or transported from elsewhere. Sample collection and transport were straightforward. This 4 kb fragment contains all the currently recognised hybrid gene 'crossover' points. Results: Within a single family, long-PCR identified all 21 individuals known to have FH-I. Hypertension was corrected in all 11 treated with glucocorticoids. Nine with normal blood pressure are being closely followed for development of hypertension. Long-PCR cord blood analysis excluded FH-I in three neonates born to affected individuals. Long-PCR newly identified two other affected families: (1) a female (60 years) with a personal and family history of stroke and her normotensive daughter (40 years), and (2) a female (51 years) previously treated for primary aldosteronism with amiloride, her two hypertensive sons (14 and 16 years) and her hypertensive mother (78 years). No false negative or false positive results have yet been encountered. At least seven other centres have successfully performed this test. Conclusion: Long-PCR is a reliable method of screening individuals of all ages for FH-I.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Organisms of the genera Toxoplasma, Hammondia and Neospora, the Hammondia-like organisms, are closely related coccidian with similarly sized oocysts. Therefore, a diagnosis based on microscopy of oocysts in feces is not a method of choice for species identification of these important parasites. In this paper, we present a polymerase chain reaction coupled with restriction fragment length polymorphism (PCR-RFLP) method to differentially diagnose oocysts of Toxoplasma gondii from oocyst of Hammondia hammondi. Another PCR-RFLP was designed to differentiate oocysts of Hammondia heydorni from oocysts of Neospora spp. Both PCR-RFLP are based on nucleotide sequences of the Hsp70 coding gene. In conclusion, we presented two alternative molecular diagnostic assays that can be successfully applied for the differentiation of oocysts of Hammondia-like organisms shed by felids and canids.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Primers and DNA probes designed for use in the specific detection of the paramyxean parasites Marteilia sydneyi and Marteilia refringens were tested for their potential to cross-react with closely related species in Polymerase Chain Reaction (PCR) and in situ hybridization. PCR primers and a DNA probe designed within the ITS1 rRNA of M. sydneyi were specific for M. sydneyi when compared with related species of Marteilia and Marteilioides. PCR primers designed within the 18S rRNA of M. refringens were specific in the detection of this species in PCR while a DNA probe (named Smart 2) designed on the same gene cross-reacted with M. sydneyi in tissue sections of Saccostrea glomerata as well as Marteilioides sp. infecting Striostrea mytiloides. Though not species specific, the Smart 2 probe provided a stronger signal in detection of all stages of M. sydneyi than the ITS1 probe. The ITS probe is proposed for use as a confirmatory diagnostic too] for M. sydneyi.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A newly developed solid-state repetitive high-voltage (HV) pulse modulator topology created from the mature concept of the d.c. voltage multiplier (VM) is described. The proposed circuit is based in a voltage multiplier type circuit, where a number of d.c. capacitors share a common connection with different voltage rating in each one. Hence, besides the standard VM rectifier and coupling diodes, two solid-state on/off switches are used, in each stage, to switch from the typical charging VM mode to a pulse mode with the d.c. capacitors connected in series with the load. Due to the on/off semiconductor configuration, in half-bridge structures, the maximum voltage blocked by each one is the d.c. capacitor voltage in each stage. A 2 kV prototype is described and the results are compared with PSPICE simulations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dissertação para a obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Energia

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Supernatant of boiled spleen saline-suspensions of Yersinia pestis experimentally infected animals were used as template for PCR amplification without DNA extraction. PCR sensitivity was enhanced by a second round of amplification (Nested). No amplification was observed from non-infected animals.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Herpetic infections are common complications in AIDS patients. The clinical features could be uncommon and antiviral chemotherapy is imperative. A rapid diagnosis could prevent incorrect approaches and treatment. The polymerase chain reaction is a rapid, specific and sensible method for DNA amplification and diagnosis of infectious diseases, especially viral diseases. This approach has some advantages compared with conventional diagnostic procedures. Recently we have reported a new PCR protocol to rapid diagnosis of herpetic infections with suppression of the DNA extraction step. In this paper we present a case of herpetic whitlow with rapid diagnosis by HSV-1 specific polymerase chain reaction using the referred protocol.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PLos One, 4(11): ARTe7722

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Although the Giemsa-stained thick blood smear (GTS) remains the gold standard for the diagnosis of malaria, molecular methods are more sensitive and specific to detect parasites and can be used at reference centers to evaluate the performance of microscopy. The description of the Plasmodium falciparum, P. vivax, P. malariae and P. ovale ssrRNA gene sequences allowed the development of a polymerase chain reaction (PCR) that had been used to differentiate the four species. The objective of this study was to determine Plasmodium species through PCR in 190 positive smears from patients in order to verify the quality of diagnosis at SUCEN's Malaria Laboratory. Considering only the 131 positive results in both techniques, GTS detected 4.6% of mixed and 3.1% of P. malariae infections whereas PCR identified 19.1% and 13.8%, respectively.