967 resultados para Reactive force field
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
The objective of this study was to evaluate the retention force of T-bar clasps made from commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) alloy by the insertion/removal test simulating 5 years use. Thirty-six frameworks were cast from CP Ti (n=18) and Co-Cr alloy (n=18) with identical prefabricated patterns on refractory casts from a distal extension mandibular hemi-arch segment. The castings were made on a vacuum-pressure machine, under vacuum and argon atmosphere. Each group was subdivided in three, corresponding to 0.25 mm, 0.50 mm and 0.75 mm undercuts, respectively. No polishing procedures were performed to ensure uniformity. The specimens were subjected to an insertion/removal test and data was analyzed statistically to compare CP Ti and Co-Cr alloy in the same undercut (Student's t-test for independent samples) and each material in different undercuts (one-way ANOVA) (p=0.05). Comparisons between materials revealed significant differences (p=0.017) only for the 0.50-mm undercut. No significant differences (p>0.05) were found when comparing the same material for the undercuts. It may be concluded that for different undercuts, both Co-Cr alloy and CP Ti had no significant differences for T-bar clasps; CP Ti showed the lowest retention force values when compared to Co-Cr alloy in each undercut, but with significant difference only for the 0.50-mm undercut; and both materials maintained the retentive capacity during the simulation test.
Resumo:
The signs and symptoms of temporomandibular dysfunction (TMD) may contribute to reduce bite force and muscular activity. The aims of this study were to compare bite force in complete denture wearers with TMD (TMD group) and without TMD (healthy group).The TMD group consisted of 9 individuals, who had worn a maxillary and a mandibular complete removable denture for more than 10 years. The healthy group consisted of 9 participants who wore dentures and had satisfactory interocclusal and maxillomandibular relationship. Helkimo Index was used to analyze the dysfunction level. Maximum bite force was measured using a digital dynamometer with capacity of 100 kgf and adapted to oral conditions.The TMD group presented smaller mean bite force values than the healthy group, though without statistical significance (p>0.05). This outcome suggests that the TMD signs and symptoms and the structural conditions of the dentures did not affect the maximal bite force of complete denture wearers.
Resumo:
The clingfish Gobiesox barbatulus shows nocturnal feeding activity, spending most part of the day stationary and adhered to the inferior part of stones. To feed, this species uses the sit-and-wait and particulate feeding tactics. It shows a carnivorous feeding habit mostly consuming small benthic crustaceans. It can move in two ways: (1) "stone-by-stone", sliding its ventral sucker disc across each stone and (2) "surf", when it takes advantage of the energy of the ebbing tide to quickly cross a distance up to four times its body length. Its reproductive season occurs between the end of spring and the beginning of summer, during which time it lays about 2,000 adhesive eggs of 1 mm each in a single layer under stones. It has more than one egg-laying session per reproductive season, therefore showing several different developmental stages. It performs fanning, mouthing and guarding of the eggs as forms of parental care. Data shown here also indicates that G. barbatulus has some shelter fidelity, being probably territorial.
Resumo:
Electrochemical removals of color and organic load from solutions containing the dye reactive orange 16 (RO16) were performed in an electrochemical flow-cell, using a platinum working electrode. The influence of the process variables flow-rate, such as NaCl concentration, applied potential and solution pH, were studied. The best color removal achieved was 93% (λ = 493 nm) after 60 min at 2.2 V vs. RHE electrolysis, using 1.00 g L-1 NaCl as supporting electrolyte. The rises in the concentration of NaCl and applied potential increased the color removal rate. The best total organic carbon removal (57%) was obtained at 1.8 V, without the separating membrane, indicating that the ideal conditions for the color removal are not necessarily the same as those to remove the total organic carbon. The degradation efficiency decreased with the solution pH decrease.
Resumo:
Being the commonest ocular disorder, dense cataracts disable fundoscopic examination and the diagnosis of retinal disorders, which dogs may be predisposed. The aim of this study was to compare the electroretinographic responses recorded according to the International Society for Clinical Electrophysiology of Vision human protocol to evaluate retinal function of diabetic and non diabetic dogs, both presenting mature or hypermature cataracts. Full-field electroretinogram was recorded from 66 dogs, with ages varying from 6 to 15 years old allocated into two groups: (1) CG, non diabetic cataractous dogs, and (2) DG, diabetic cataractous dogs. Mean peak-to-peak amplitude (microvolts) and b-wave implicit time (milliseconds) were determined for each of the five standard full-field ERG responses (rod response, maximal response, oscillatory potentials, single-flash cone response and 30 Hz flicker). Comparing CG to DG, ERGs recorded from diabetic dogs presented lower amplitude and prolonged b-wave implicit time in all ERG responses. Prolonged b-wave implicit time was statistically significant (p< 0.05) at 30 Hz flicker (24.0 ms versus 22.4 ms). These data suggests full-field ERG is capable to record sensible alterations, such as flicker's implicit time, being useful to investigate retinal dysfunction in diabetic dogs.
Resumo:
The endocannabinoid system is involved in the control of many physiological functions, including the control of emotional states. In rodents, previous exposure to an open field increases the anxiety-like behavior in the elevated plus-maze. Anxiolytic-like effects of pharmacological compounds that increase endocannabinoid levels have been well documented. However, these effects are more evident in animals with high anxiety levels. Several studies have described characteristic inverted U-shaped dose-response effects of drugs that modulate the endocannabinoid levels. However, there are no studies showing the effects of different doses of exogenous anandamide, an endocannabinoid, in animal models of anxiety. Thus, in the present study, we determined the dose-response effects of exogenous anandamide at doses of 0.01, 0.1, and 1.0 mg/kg in C57BL/6 mice (N = 10/group) sequentially submitted to the open field and elevated plus-maze. Anandamide was diluted in 0.9% saline, ethyl alcohol, Emulphor® (18:1:1) and administered ip (0.1 mL/10 g body weight); control animals received the same volume of anandamide vehicle. Anandamide at the dose of 0.1 mg/kg (but not of 0.01 or 1 mg/kg) increased (P < 0.05) the time spent and the distance covered in the central zone of the open field, as well as the exploration of the open arms of the elevated plus-maze. Thus, exogenous anandamide, like pharmacological compounds that increase endocannabinoid levels, promoted a characteristic inverted U-shaped dose-response effect in animal models of anxiety. Furthermore, anandamide (0.1 mg/kg) induced an anxiolytic-like effect in the elevated plus-maze (P < 0.05) after exposing the animals to the open field test.
Resumo:
Searches for field horizontal-branch (FHB) stars in the halo of the Galaxy in the past have been carried out by several techniques, such as objective-prism surveys and visual or infrared photometric surveys. By choosing adequate color criteria, it is possible to improve the efficiency of identifying bona fide FHB stars among the other objects that exhibit similar characteristics, such as main-sequence A-stars, blue stragglers, subdwarfs, etc. In this work, we report the results of a spectroscopic survey carried out near the south Galactic pole intended to validate FHB stars originally selected from the HK objective-prism survey of Beers and colleagues, based on near-infrared color indices. A comparison between the stellar spectra obtained in this survey with theoretical stellar atmosphere models allows us to determine T(eff), log g, and [Fe/H] for 13 stars in the sample. Stellar temperatures were calculated from measured (B-V)(o), when this measurement was available (16 stars). The color index criteria adopted in this work are shown to correctly classify 30% of the sample as FHB, 25% as non-FHB (main-sequence stars and subdwarfes), whereas 40% could not be distinguished between FHB and main-sequence stars. We compare the efficacy of different color criteria in the literature intended to select FHB stars, and discuss the use of the Mg II 4481 line to estimate the metallicity.
Resumo:
We explored possible effects of negative covariation among finger forces in multifinger accurate force production tasks on the classical Fitts's speed-accuracy trade-off. Healthy subjects performed cyclic force changes between pairs of targets ""as quickly and accurately as possible."" Tasks with two force amplitudes and six ratics of force amplitude to target size were performed by each of the four fingers of the right hand and four finger combinations. There was a close to linear relation between movement time and the log-transformed ratio of target amplitude to target size across all finger combinations. There was a close to linear relation between standard deviation of force amplitude and movement time. There were no differences between the performance of either of the two ""radial"" fingers (index and middle) and the multifinger tasks. The ""ulnar"" fingers (little and ring) showed higher indices of variability and longer movement times as compared with both ""radial"" fingers and multifinger combinations. We conclude that potential effects of the negative covariation and also of the task-sharing across a set of fingers are counterbalanced by an increase in individual finger force variability in multifinger tasks as compared with single-finger tasks. The results speak in favor of a feed-forward model of multifinger synergies. They corroborate a hypothesis that multifinger synergies are created not to improve overall accuracy, but to allow the system larger flexibility, for example to deal with unexpected perturbations and concomitant tasks.
Resumo:
Single-point diamond turning of monocrystalline semiconductors is an important field of research within brittle materials machining. Monocrystalline silicon samples with a (100) orientation have been diamond turned under different cutting conditions (feed rate and depth of cut). Micro-Raman spectroscopy and atomic force microscopy have been used to assess structural alterations and surface finish of the samples diamond turned under ductile and brittle modes. It was found that silicon undergoes a phase transformation when machined in the ductile mode. This phase transformation is evidenced by the creation of an amorphous surface layer after machining which has been probed by Raman scattering. Compressive residual stresses are estimated for the machined surface and it is observed that they decrease with an increase in the feed rate and depth of cut. This behaviour has been attributed to the formation of subsurface cracks when the feed rate is higher than or equal to 2.5 mu m/rev. The surface roughness was observed to vary with the feed rate and the depth of cut. An increase in the surface roughness was influenced by microcrack formation when the feed rate reached 5.0 mu m/rev. Furthermore, a high-pressure phase transformation induced by the tool/material interaction and responsible for the ductile response of this typical brittle material is discussed based upon the presented Raman spectra. The application of this machining technology finds use for a wide range of high quality components, for example the creation of a micrometre-range channel for microfluidic devices as well as microlenses used in the infrared spectrum range.
Resumo:
In this work, the electron field emission behaviour of electrodes formed by carbon nanotubes (CNTs) grown onto monolithic vitreous carbon (VCarbon) substrates with microcavities is presented. Scanning electron microscopy was used to characterize the microstructure of the films. Tungsten probes, stainless steel sphere, and phosphor electrodes were employed in the electron field emission study. The CNT/VCarbon composite represents a route to inexpensive excellent large area electron emission cathodes with fields as low as 2.1 V mu m(-1). In preliminary lifetime tests for a period of about 24 h at an emission current of about 4 mA cm(-2), there is an onset degradation of the emission current of about 28%, which then stabilizes. Electron emission images of the composites show the cavity of the samples act as separate emission sites and predominantly control the emission process. The emission of CNTs/VCarbon was found to be stable for several hours. (c) 2008 American Institute of Physics.