907 resultados para RIGID FIXATION
Resumo:
Background: the effective long-term treatments for morbid obesity is bariatric surgery. However, the associated surgical and anesthetic risks led the authors to evaluate intermaxillary fixation, a less aggressive procedure, as a preoperative treatment in selected patients with morid obesity.Methods: 22 patients (5 male, 17 female, ages 16-53 years, with BMI 44.9 +/- 5.4 kg/m(2)) underwent intermaxillary fixation. The procedure consisted of fitting brackets on the front face of the teeth and posterior application of elastic bands to impede mouth opening.Results: At the end of 6 weeks, weight loss was 7.4 +/- 2.6% there was general improvement in lipid profile, glycemia, and blood pressure. There was no recorded discomfort, pain, or any other difficulty during this treatment.Conclusion: Intermaxillary fixation can be used as a pre-surgical solution for weight reduction in preparation for bariatric surgery, improving co-morbid aspects such as blood pressure, glycemia, and lipid profile.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Among the osteotomies performed in orthognathic surgery, the sagittal osteotomy of the mandibular ramus (SOMR) is the most common, allowing a great range of movements and stable internal fixation (SIF), therefore eliminating the need of maxillomandibular block in the postoperative period. Objectives: The purpose of this study was to evaluate the biomechanical resistance of three national systems used for SIF in SOMR in sheep mandibles. Material and methods: The study was performed in 30 sheep hemi-mandibles randomly divided into 3 experimental groups, each containing 10 hemi-mandibles. The samples were measured to avoid discrepancies and then subjected to SOMR with 5-mm advancement. In group I, 2.0x12 mm screws were used for fixation, inserted in an inverted "L" pattern (inverted "L" group). In group II, fixation was performed with two 2.0x12 mm screws, positioned in a linear pattern and a 4-hole straight miniplate and four 2.0x6.0 mm monocortical screws (hybrid group). In group III, fixation was performed with two-hole straight miniplates and eight 2.0x6.0 mm monocortical screws (mini plate group). All materials used for SIF were supplied by Osteosin - SIN. The hemimandibles were subjected to vertical linear load test by Kratos K2000MP mechanical testing unit for loading registration and displacement. Results: All groups showed similar resistance during mechanical test for loading and displacement, with no statistically significant differences between groups according to analysis of variance. Conclusion: These results indicate that the three techniques of fixation are equally effective for clinical fixation of SOMR.
Resumo:
The fixation and the bone ingrowth at the interface of porous cylindrical implants (total porosity of 37% and average pores diameter of 480 mu m) were compared in vivo to rough cylindrical implants (R-a = 5.3 mu m), both of commercially pure titanium, made by powder metallurgy. The implants were inserted into the tibias of 20 rabbits and the animals were sacrificed 4 and 8 weeks after surgery. The percentage of bone-implant contact observed in porous implant was significantly larger than in the rough ones for all of sacrifice periods, respectively, 57% vs. 46% after 4 weeks, and 59% vs. 50% after 8 weeks. The mechanical tests showed a significant increase in the shear strength of the porous implants for the two analyzed periods, 4 and 8 weeks (14 and 20 MPa), when compared with rough ones (4 and 13 MPa). These results suggest that porous implants improve the contact at the implant-bone interface and increase the fixation to the bone, improving the osseointegration. Thus, the porous implant might be an alternative to dental implant in less favorable conditions, and appear to be better fixed to bone, offering promising alternatives.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A espectroscopia fotoacústica obtém informações sobre amplitude e fase, da resposta de um sistema submetido a excitação por luz. Este artigo apresenta estudos do ângulo de fase no processo de transfereência de elétrons entre octaetilporfirina (OEP) e derivados de quinona ambos dispersos em uma matriz polimérica. Observou-se uma tendência no comportamento da fase para valores menores na região espectral próximo de 620 nm. Enquanto que para comprimentos de onda menores este efeito não foi apresentado. Estas medidas sugerem que a transferência de elétrons para o aceitador ocorreu com a participação do estado singleto excitado da octaetilporfirina.
Resumo:
An analytical method is proposed to study the attitude stability of a triaxial spacecraft moving in a circular Keplerian orbit in the geomagnetic field. The method is developed based on the electrodynamics effect of the influence of the Lorentz force acting on the charged spacecraft's surface. We assume that the rigid spacecraft is equipped with an electrostatic charged protective shield, having an intrinsic magnetic moment. The main elements of this shield are an electrostatic charged cylindrical screen surrounding the protected volume of the spacecraft. The rotational motion of the spacecraft about its centre of mass due to torques from gravitational force, as well Lorentz and magnetic forces is investigated. The equilibrium positions of the spacecraft in the orbital coordinate system are obtained. The necessary and sufficient conditions for the stability of the spacecraft's equilibrium positions are constructed using Lyapunov's direct method. The numerical results have shown that the Lorentz force has a significant influence on the stability of the equilibrium positions, which can affect the attitude stabilization of the spacecraft. (C) 2007 COSPAR. Published by Elsevier Ltd. All rights reserved.
Resumo:
A simple and easily implemented method is developed to keep the vertical velocity equal to zero at the bottom and top of hydrostatic incompressible numerical models. The pressure is computed at the top by correcting its value given in the previous time step so that the vertical integral of the horizontal divergence is zero at each column. Numerical experiments that exhibit small time variations of pressure at the top are able to simplify the algorithm and save computer time. Numerical simulations illustrate the method effectiveness for a horizontal deformation-induced frontogenesis.
Resumo:
Facial injuries with the retention of foreign bodies inside the tissues, both in soft and hard ones, can cause major functional and aesthetic damage. Among the different etiological agents, cutting tools, fragments of a firearm, the splinter of wood, steel, or iron, launched by misuse, or even caused by defects in equipment, are the main cause of these injuries. The aim of this study was to discuss the peculiarity of the multidisciplinary approach in caring of a 33-year-old man, victim of an accident at work, by the rupture of an emery disc and consequent penetration of the fragments in violation of the tissues in the orbital and zygomatic region of the left side, with perforation of the eyeball and orbital-zygomatic fracture. Urgent treatment consisted of debridement of wounds, bleeding control, removal of foreign bodies, fracture reduction with rigid internal fixation, and suture, performed by the oral and maxillofacial surgical team. Reconstruction of orbital tissues by the ophthalmology team consisted of suture of the injuries. About 1 month after the trauma, phthisis bulbi was noted, and the patient underwent a new procedure under general anesthesia for eye evisceration and installation of an alloplastic prosthesis associated with the homogenous sclera. Facial harmony was restored, especially in aesthetics and function of the zygomatic-orbital complex.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this work, the behaviour of the system with N massive parallel rigid wires is analysed. The aim is to explore its resemblance to a system of multiple cosmic strings. Assuming that it behaves like a 'gas' of massive rigid wires, we use a thermodynamics approach to describe this system. We obtain a constraint relating the linear mass density of the massive wires, the number of the massive wires in the system and the dispersion velocity of the system. © 1996 IOP Publishing Ltd.
Resumo:
IgG, IgM and IgA antibodies to GP43 (glycoprotein fraction of Paracoccidioides brasiliensis) were measured by ELISA in 63 samples from 23 patients with paracoccidioidomycosis before and twice after chemotherapy was started. Antibodies against P. brasiliensis were detected by indirect immunofluorescence (IF) (IgG, IgM and IgA isotypes), counterimmunoelectrophoresis (CIE) and complement fixation. Two control groups composed of 19 healthy individuals and 12 patients with other diseases (six with histoplasmosis, three with tuberculosis and three with other mycoses). The highest efficiency percentages were found with IgG and IgA- ELISA (100%), IgG-IF (96.2%), CIE (94.4%) and the lowest with CF (75.9%). Highest positive and negative predictive values (100%) were observed for IgG and IgA ELISA. IgG and IgM-ELISA antibodies are more often found in patients with acute than chronic disease (P = 0.01). Four to six months after treatment follow-up showed decreased levels of IgG and IgM-ELISA for acute cases and decreased titres of CIE for chronic cases in relation to pretreatment levels. This study suggests that IgG-ELISA anti-GP43 represents a good marker to monitor clinical response to therapy.