498 resultados para Protons.
Resumo:
In this thesis the measurement of the effective weak mixing angle wma in proton-proton collisions is described. The results are extracted from the forward-backward asymmetry (AFB) in electron-positron final states at the ATLAS experiment at the LHC. The AFB is defined upon the distribution of the polar angle between the incoming quark and outgoing lepton. The signal process used in this study is the reaction pp to zgamma + X to ee + X taking a total integrated luminosity of 4.8\,fb^(-1) of data into account. The data was recorded at a proton-proton center-of-mass energy of sqrt(s)=7TeV. The weak mixing angle is a central parameter of the electroweak theory of the Standard Model (SM) and relates the neutral current interactions of electromagnetism and weak force. The higher order corrections on wma are related to other SM parameters like the mass of the Higgs boson.rnrnBecause of the symmetric initial state constellation of colliding protons, there is no favoured forward or backward direction in the experimental setup. The reference axis used in the definition of the polar angle is therefore chosen with respect to the longitudinal boost of the electron-positron final state. This leads to events with low absolute rapidity have a higher chance of being assigned to the opposite direction of the reference axis. This effect called dilution is reduced when events at higher rapidities are used. It can be studied including electrons and positrons in the forward regions of the ATLAS calorimeters. Electrons and positrons are further referred to as electrons. To include the electrons from the forward region, the energy calibration for the forward calorimeters had to be redone. This calibration is performed by inter-calibrating the forward electron energy scale using pairs of a central and a forward electron and the previously derived central electron energy calibration. The uncertainty is shown to be dominated by the systematic variations.rnrnThe extraction of wma is performed using chi^2 tests, comparing the measured distribution of AFB in data to a set of template distributions with varied values of wma. The templates are built in a forward folding technique using modified generator level samples and the official fully simulated signal sample with full detector simulation and particle reconstruction and identification. The analysis is performed in two different channels: pairs of central electrons or one central and one forward electron. The results of the two channels are in good agreement and are the first measurements of wma at the Z resonance using electron final states at proton-proton collisions at sqrt(s)=7TeV. The precision of the measurement is already systematically limited mostly by the uncertainties resulting from the knowledge of the parton distribution functions (PDF) and the systematic uncertainties of the energy calibration.rnrnThe extracted results of wma are combined and yield a value of wma_comb = 0.2288 +- 0.0004 (stat.) +- 0.0009 (syst.) = 0.2288 +- 0.0010 (tot.). The measurements are compared to the results of previous measurements at the Z boson resonance. The deviation with respect to the combined result provided by the LEP and SLC experiments is up to 2.7 standard deviations.
Resumo:
Am Mainzer Mikrotron können Lambda-Hyperkerne in (e,e'K^+)-Reaktionen erzeugt werden. Durch den Nachweis des erzeugten Kaons im KAOS-Spektrometer lassen sich Reaktionen markieren, bei denen ein Hyperon erzeugt wurde. Die Spektroskopie geladener Pionen, die aus schwachen Zweikörperzerfällen leichter Hyperkerne stammen, erlaubt es die Bindungsenergie des Hyperons im Kern mit hoher Präzision zu bestimmen. Neben der direkten Produktion von Hyperkernen ist auch die Erzeugung durch die Fragmentierung eines hoch angeregten Kontinuumszustands möglich. Dadurch können unterschiedliche Hyperkerne in einem Experiment untersucht werden. Für die Spektroskopie der Zerfallspionen stehen hochauflösende Magnetspektrometer zur Verfügung. Um die Grundzustandsmasse der Hyperkerne aus dem Pionimpuls zu berechnen, ist es erforderlich, dass das Hyperfragment vor dem Zerfall im Target abgebremst wird. Basierend auf dem bekannten Wirkungsquerschnitt der elementaren Kaon-Photoproduktion wurde eine Berechnung der zu erwartenden Ereignisrate vorgenommen. Es wurde eine Monte-Carlo-Simulation entwickelt, die den Fragmentierungsprozess und das Abbremsen der Hyperfragmente im Target beinhaltet. Diese nutzt ein statistisches Aufbruchsmodell zur Beschreibung der Fragmentierung. Dieser Ansatz ermöglicht für Wasserstoff-4-Lambda-Hyperkerne eine Vorhersage der zu erwartenden Zählrate an Zerfallspionen. In einem Pilotexperiment im Jahr 2011 wurde erstmalig an MAMI der Nachweis von Hadronen mit dem KAOS-Spektrometer unter einem Streuwinkel von 0° demonstriert, und koinzident dazu Pionen nachgewiesen. Es zeigte sich, dass bedingt durch die hohen Untergrundraten von Positronen in KAOS eine eindeutige Identifizierung von Hyperkernen in dieser Konfiguration nicht möglich war. Basierend auf diesen Erkenntnissen wurde das KAOS-Spektrometer so modifiziert, dass es als dedizierter Kaonenmarkierer fungierte. Zu diesem Zweck wurde ein Absorber aus Blei im Spektrometer montiert, in dem Positronen durch Schauerbildung abgestoppt werden. Die Auswirkung eines solchen Absorbers wurde in einem Strahltest untersucht. Eine Simulation basierend auf Geant4 wurde entwickelt mittels derer der Aufbau von Absorber und Detektoren optimiert wurde, und die Vorhersagen über die Auswirkung auf die Datenqualität ermöglichte. Zusätzlich wurden mit der Simulation individuelle Rückrechnungsmatrizen für Kaonen, Pionen und Protonen erzeugt, die die Wechselwirkung der Teilchen mit der Bleiwand beinhalteten, und somit eine Korrektur der Auswirkungen ermöglichen. Mit dem verbesserten Aufbau wurde 2012 eine Produktionsstrahlzeit durchgeführt, wobei erfolgreich Kaonen unter 0° Streuwinkel koninzident mit Pionen aus schwachen Zerfällen detektiert werden konnten. Dabei konnte im Impulsspektrum der Zerfallspionen eine Überhöhung mit einer Signifikanz, die einem p-Wert von 2,5 x 10^-4 entspricht, festgestellt werden. Diese Ereignisse können aufgrund ihres Impulses, den Zerfällen von Wasserstoff-4-Lambda-Hyperkernen zugeordnet werden, wobei die Anzahl detektierter Pionen konsistent mit der berechneten Ausbeute ist.
Resumo:
Produktionsmechanismen für Teilchenproduktion im mittleren Energiebereich wurden in Proton-Proton Kollisionen innerhalb der COMPASS-Kollaboration mit Hilfe des COMPASS-Spektrometers am SPS Beschleuniger am CERN untersucht. Die verschiedenen Produktionsmechanismen werden mittels Produktion der Vektormesonen omega und phi studiert und können die diffraktive Anregung des Strahlteilchens mit anschliessendem Zerfall der Resonanz, zentrale Produktion und den damit verwandten “Shake-off” Mechanismus enthalten. Die für diese Arbeit verwendeten Daten wurden in den Jahren 2008 und 2009 mit 190 GeV/c-Protonen aufgenommen, die auf ein Flüssigwasserstofftarget trafen. Das Target war von einem Rückstoßprotonendetektor umgeben, der ein integraler Bestandteil des neuentwickelten Hadrontriggersystems ist. Für dieses System wurden außerdem einige neue Detektoren gebaut. Die Leistungsfähigkeit des Rückstoßprotonendetektors und des Triggersystems wird untersucht und Effizienzen extrahiert. Außerdem wird sowohl eine Methode zur Rekonstruktion von Rückstoßprotonen als auch eine Methode zur Kalibration des Rückstoßprotonendetektors entwickelt und beschrieben. Die Produktion von omega-Mesonen wurde in der Reaktion pp -> p omega p, omega -> pi+pi-pi0 und die Produktion von phi-Mesonen in der Reaktion pp -> p phi p, phi -> K+K- bei einem Impulsübertrag zwischen 0.1 (GeV/c)^2 und 1 (GeV/c)^2 gemessen. Das Produktionsverhältnis s(pp -> p phi p)/s(pp -> p omega p) wird als Funktion des longitudinalen Impulsanteils xF bestimmt und mit der Vorhersage durch die Zweigregel verglichen. Es ergibt sich eine signifikante Verletzung der Zweigregel, die abhängig von xF ist. Die Verletzung wird in Verbindung zu resonanten Strukturen im pomega-Massenspektrum diskutiert. Die xF-Abhängigkeit verschwindet, wenn man die Region niedriger pomega- und pphi-Masse entfernt, die solche resonanten Strukturen aufweist. Zusätzlich wird die Spinausrichtung bzw. das Spindichtematrixelement rho00 für omega- und phi-Mesonen untersucht. Die Spinausrichtung wird im Helizitätssystemrnanalysiert, welches für eine Abgrenzung von resonanten, diffraktiven Anregungen geeignet ist. Außerdem wird die Spinausrichtung in einem Referenzsystem mit Bezug auf die Richtung des Impulsübertrags untersucht, mit dessen Hilfe zentrale Prozesse wie zentrale Produktion oder “shake-off” abgegrenzt werden. Auch hier wird eine Abhängigkeit von xF und der invarianten Masse des pomega-Systems beobachtet. Diese Abhängigkeit kann wieder auf die resonanten Strukturen in der Produktion von omega-Mesonen zurückgeführt werden. Die Ergebnisse werden abschließend im Hinblick auf die verschiedenen Produktionsmechanismen diskutiert.
Resumo:
Diese Arbeit befasst sich mit der photoinduzierten Erzeugung neutraler Pionen, sehr nahe an der Schwellenenergie. Dabei werden zwei Ziele verfolgt: Zum einen die Überprüfung von Vorhersagen dieser effektiven Theorien und Modelle, zum anderen werden hier erstmals alle relevanten Partialwellenamplituden modellunabhängig aus gemessenen Observablen bestimmt. Diese Methode soll in Zukunft auch bei höheren Energien im Bereich der Nukleonresonanzen Anwendung finden. rnrnKonkret wird die Durchführung und Analyse eines Experiments vorgestellt, welches am Mainzer Mikrotron (MAMI) in den Jahren 2010 bis 2013 mit zirkular polarisiertem Photonenstrahl stattfand. Der Photonenstrahl wurde an einer Anlage zur Erzeugung energiemarkierter Bremsstrahlung aus dem Elektronenstrahl von MAMI gewonnen. Zum Nachweis der Reaktionsprodukte diente das hermetische 4pi CB/TAPS-Detektorsystem. Erstmalig standen bei derartigen Messungen auch transversal polarisierte Protonen zur Verfügung. Dazu wird Butanol in einer speziellen Apparatur dynamisch polarisiert. Molekularer Wasserstoff lässt sich aufgrund der para-Konfiguration nicht polarisieren. Wegen der Verwendung von Butanol als Targetmaterial, bei dem weniger als 5% aller erzeugten Pionen an polarisierten Protonen produziert wurden, ist die Behandlung des Untergrunds eine zentrale Aufgabe. rnrnEs werden zwei Methoden der Untergrundseparation vorgestellt, wovon die bessere in der Analyse angewendet wurde. Abschließend findet eine ausführliche Bewertung systematischer Fehler statt.rnrnDie erstmalige Verwendung transversal polarisierter Protonen ermöglicht den Zugang zu bisher nicht gemessenen Spin"=Freiheitsgraden. In Kombination mit einem komplementären Vorläufer-Experiment aus dem Jahr 2008 mit linear polarisiertem Photonenstrahl konnten aus den gewonnenen Daten erstmals alle komplexen s- und p-Partialwellenamplituden modellunabhängig bestimmt werden. rnrnDarüber hinaus wurden im Rahmen dieser Arbeit wesentliche Verbesserungen am apparativen Aufbau erzielt. Beispiele sind ein Elektronenstrahl-Polarimeter, ein zellularer CB-Multiplizitätstrigger, sowie signifikante Verbesserungen der Datennahmeelektronik und des Triggersystems, die teilweise in dieser Arbeit vorgestellt werden.
Resumo:
In dieser Arbeit wurde die paritätsverletzende Asymmetrie in derrnquasielastischen Elektron-Deuteron-Streuung bei Q^2=0.23 (GeV/c)^2 mitrneinem longitudinal polarisierten Elektronstrahl bei einer Energie von 315rnMeV bestimmt. Die Messung erfolgte unter Rückwärtswinkeln. Der Detektor überdeckte einen polaren Streuwinkelbereichrnzwischen 140 und 150 deg. Das Target bestand aus flüssigemrnDeuterium in einer Targetzelle mit einer Länge von 23.4 cm. Dierngemessene paritätsverletzende Asymmetrie beträgt A_{PV}^d = (-20.11 pm 0.87_{stat} pm 1.03_{syst}), wobei der erste Fehler den statistischenrnFehlereitrag und der zweite den systematischen Fehlerbeitrag beschreibt. Ausrnder Kombination dieser Messung mit Messungen der paritätsverletzendenrnAsymmetrie in der elastischen Elektron-Proton-Streuung bei gleichem Q^2rnsowohl bei Vorwärts- als auch bei Rückwärtsmessungen können diernVektor-Strange-Formfaktoren sowie der effektive isovektorielle und isoskalarernVektorstrom des Protons, der die elektroschwachen radiativen Anapolkorrekturenrnenthält, bestimmt werden. Diese Arbeit umfasst ausserdem die Bestimmungrnder Asymmetrien bei einem transversal polarisierten Elektronstrahl sowohl beirneinem Proton- als auch einem Deuterontarget unter Rückwärtswinkeln beirnImpulsüberträgen von Q^2=0.10 (GeV/c)^2, Q^2=0.23 (GeV/c)^2rnund Q^2=0.35 (GeV/c)^2. Die im Experiment beobachteten Asymmetrien werdenrnmit theoretischen Berechnungen verglichen, welche den Imaginärteil der Zweiphoton-Austauschamplitude beinhalten.
Resumo:
The excitation spectrum is one of the fundamental properties of every spatially extended system. The excitations of the building blocks of normal matter, i.e., protons and neutrons (nucleons), play an important role in our understanding of the low energy regime of the strong interaction. Due to the large coupling, perturbative solutions of quantum chromodynamics (QCD) are not appropriate to calculate long-range phenomena of hadrons. For many years, constituent quark models were used to understand the excitation spectra. Recently, calculations in lattice QCD make first connections between excited nucleons and the fundamental field quanta (quarks and gluons). Due to their short lifetime and large decay width, excited nucleons appear as resonances in scattering processes like pion nucleon scattering or meson photoproduction. In order to disentangle individual resonances with definite spin and parity in experimental data, partial wave analyses are necessary. Unique solutions in these analyses can only be expected if sufficient empirical information about spin degrees of freedom is available. The measurement of spin observables in pion photoproduction is the focus of this thesis. The polarized electron beam of the Mainz Microtron (MAMI) was used to produce high-intensity, polarized photon beams with tagged energies up to 1.47 GeV. A "frozen-spin" Butanol target in combination with an almost 4π detector setup consisting of the Crystal Ball and the TAPS calorimeters allowed the precise determination of the helicity dependence of the γp → π0p reaction. In this thesis, as an improvement of the target setup, an internal polarizing solenoid has been constructed and tested. A magnetic field of 2.32 T and homogeneity of 1.22×10−3 in the target volume have been achieved. The helicity asymmetry E, i.e., the difference of events with total helicity 1/2 and 3/2 divided by the sum, was determined from data taken in the years 2013-14. The subtraction of background events arising from nucleons bound in Carbon and Oxygen was an important part of the analysis. The results for the asymmetry E are compared to existing data and predictions from various models. The results show a reasonable agreement to the models in the energy region of the ∆(1232)-resonance but large discrepancies are observed for energy above 600 MeV. The expansion of the present data in terms of Legendre polynomials, shows the sensitivity of the data to partial wave amplitudes up to F-waves. Additionally, a first, preliminary multipole analysis of the present data together with other results from the Crystal Ball experiment has been as been performed.
Resumo:
Neuroimaging using magnetic resonance imaging (MRI) is required for the investigation of surgically intractable epilepsy. In addition to the standard MRI techniques, perfusion sequences can be added to improve visualization of the underlying pathological changes. Also, as arterial spin-labeling (ASL) MRI perfusion does not require contrast administration, it may even be advantageous in these patients. We report here on three patients with epilepsy and tuberous sclerosis who underwent brain MRI with ASL and positron emission tomography (PET), both of which were found to correlate with each other and with electrophysiological data.
Resumo:
INTRODUCTION: Magnetic resonance imaging (MRI) is required for the investigation of surgically intractable epilepsy. In addition to the standard MRI techniques, perfusion sequences can be added to improve visualization of underlying pathological changes. Arterial spin-labeling (ASL) MRI perfusion does not require contrast administration and, for this reason, may have advantages in these patients. METHODS: We report here on 16 patients with epilepsy who underwent MRI of the brain with ASL and positron emission tomography (PET). RESULTS: Despite a slightly reduced resolution with ASL, we found a correlation between ASL, PET and electrophysiological data, with hypoperfusion on ASL that corresponded with hypoperfusion on interictal PET. CONCLUSION: Given the correlation between ASL and PET and electrophysiology, perfusion with ASL could become part of the standard work-up in patients with epilepsy.
Resumo:
Although the Monte Carlo (MC) method allows accurate dose calculation for proton radiotherapy, its usage is limited due to long computing time. In order to gain efficiency, a new macro MC (MMC) technique for proton dose calculations has been developed. The basic principle of the MMC transport is a local to global MC approach. The local simulations using GEANT4 consist of mono-energetic proton pencil beams impinging perpendicularly on slabs of different thicknesses and different materials (water, air, lung, adipose, muscle, spongiosa, cortical bone). During the local simulation multiple scattering, ionization as well as elastic and inelastic interactions have been taken into account and the physical characteristics such as lateral displacement, direction distributions and energy loss have been scored for primary and secondary particles. The scored data from appropriate slabs is then used for the stepwise transport of the protons in the MMC simulation while calculating the energy loss along the path between entrance and exit position. Additionally, based on local simulations the radiation transport of neutrons and the generated ions are included into the MMC simulations for the dose calculations. In order to validate the MMC transport, calculated dose distributions using the MMC transport and GEANT4 have been compared for different mono-energetic proton pencil beams impinging on different phantoms including homogeneous and inhomogeneous situations as well as on a patient CT scan. The agreement of calculated integral depth dose curves is better than 1% or 1 mm for all pencil beams and phantoms considered. For the dose profiles the agreement is within 1% or 1 mm in all phantoms for all energies and depths. The comparison of the dose distribution calculated using either GEANT4 or MMC in the patient also shows an agreement of within 1% or 1 mm. The efficiency of MMC is up to 200 times higher than for GEANT4. The very good level of agreement in the dose comparisons demonstrate that the newly developed MMC transport results in very accurate and efficient dose calculations for proton beams.
Resumo:
Micelle-forming bile salts have previously been shown to be effective pseudo-stationary phases for separating the chiral isomers of binaphthyl compounds with micellar electrokinetic capillary chromatography (MEKC). Here, cholate micelles are systematically investigated via electrophoretic separations and NMR using R, S-1, 1¿- binaphthyl- 2, 2¿-diylhydrogenphosphate (BNDHP) as a model chiral analyte. The pH, temperature, and concentration of BNDHP were systematically varied while monitoring the chiral resolution obtained with MEKC and the chemical shift of various protons in NMR. NMR data for each proton on BNDHP is monitored as a function of cholate concentration: as cholate monomers begin to aggregate and the analyte molecules begin to sample the micelle aggregate we observe changes in the cholate methyl and S-BNDHP proton chemical shifts. From such NMR data, the apparent CMC of cholate at pH 12 is found to be about 13-14 mM, but this value decreases at higher pH, suggesting that more extreme pHs may give rise to more effective separations. In general, CMCs increase with temperature indicating that one may be able to obtain better separations at lower temperatures. S-BNDHP concentrations ranging from 50 ¿M to 400 ¿M (pH 12.8) gave rise to apparent cholate CMC values from 10 mM to 8 mM, respectively, indicating that S-BNDHP, the chiral analyte molecule, may play an active role in stabilizing cholate aggregates. In all, these data show that NMR can be used to systematically investigate a complex multi-variable landscape of potential optimizations of chiral separations.
Resumo:
Bile salts are known to aggregate into micelles in biological systems; however, the fundamental structure and dynamics of bile molecule micelle formation are poorly understood. Previous studies have established that the bile salt cholate is capable of performing chirally selective micellar electrokinetic capillary chromatography (MEKC) separations of model racemic binaphthyl compounds 1,1¿-binaphthyl-2,2¿-diyl hydrogen phosphate (R,S-BNDHP) and 1,1¿-bi-2-naphthol (R,S-BN). Nuclear magnetic resonance (NMR) has been established as a complementary technique for understanding chiral selectivity and micelle formation events based on changes in proton chemical shifts of the probe molecules BNDHP and BN as well as of cholate. This work investigated the effects of the probe molecule, the alkali cation identity and temperature on cholate micelle aggregation and MEKC separations of R,S-BN and R,S-BNDHP. The probe molecule was found to mediate micelle formation by MEKC and proton NMR. A low (0.1 mM) concentration of probe was found to have minimal effects on micellization events detected by proton NMR while higher probe concentration (2.5 mM) was found to mediate micellization causing micellization events to occur at lower cholate concentrations. This work also investigated the effects of alkali counterion on chiral separation. Generally, counterions with larger crystal cationic radius were found to cause greater chiral separation power. NMR data suggest that protons near the surface of the cholate micelle are most sensitive to the cation identity, suggesting a model of improved separation based on the cation sterically inhibiting binding of one isomer. Finally, the effect of temperature on MEKC separation was investigated. Separation power of R,S-BN and R,S-BNDHP appeared to increase linearly with temperature for 22.0 mM to 50.0 mM pH 12.0 cholate. In total, these results indicate that cholate aggregation is dependent on multiple conditions. Understanding the roles that these factors play in influencing cholate micellization can inform better separation in MEKC.
Resumo:
The results from the Sub-keV Atom Reflecting Analyzer (SARA) experiment onboard Chandrayaan-1 have revealed several hitherto unknown and interesting aspects about the interaction of solar wind with the Moon. The SARA experiment had two sensors — CENA and SWIM. The Chandrayaan-1 energetic neutrals analyzer (CENA), detected energetic neutral atoms (ENAs), and the Solar Wind Monitor (SWIM) measured ions of solar wind origin. In this review, we summarize the observations made by the SARA experiment, which are: (1) substantial (~20%) and sustained backscattering of solar wind protons from lunar surface as energetic neutral hydrogen,1 (2) minimagnetosphere around magnetic anomalies on Moon using the backscattered ENAs,2 (3) reflection of solar wind protons from the Moon surface,3 (4) huge (~50%) deflection of solar wind protons over strong magnetic anomalies,4 and (5) presence of protons in the near-lunar plasma wake.5 These results have implications on the lunar plasma environment, implantation of solar wind hydrogen on lunar surface, and behavior of small scale magnetic anomalies on planetary bodies. The SARA observations suggest that similar processes may happen on other airless bodies covered with regolith in the solar system as well as in extra-solar system. This paper presents a review of the results obtained from the SARA observation.
Resumo:
We describe the steady-state function of the ubiquitous mammalian Na/H exchanger (NHE)1 isoform in voltage-clamped Chinese hamster ovary cells, as well as other cells, using oscillating pH-sensitive microelectrodes to quantify proton fluxes via extracellular pH gradients. Giant excised patches could not be used as gigaseal formation disrupts NHE activity within the patch. We first analyzed forward transport at an extracellular pH of 8.2 with no cytoplasmic Na (i.e., nearly zero-trans). The extracellular Na concentration dependence is sigmoidal at a cytoplasmic pH of 6.8 with a Hill coefficient of 1.8. In contrast, at a cytoplasmic pH of 6.0, the Hill coefficient is <1, and Na dependence often appears biphasic. Results are similar for mouse skin fibroblasts and for an opossum kidney cell line that expresses the NHE3 isoform, whereas NHE1(-/-) skin fibroblasts generate no proton fluxes in equivalent experiments. As proton flux is decreased by increasing cytoplasmic pH, the half-maximal concentration (K(1/2)) of extracellular Na decreases less than expected for simple consecutive ion exchange models. The K(1/2) for cytoplasmic protons decreases with increasing extracellular Na, opposite to predictions of consecutive exchange models. For reverse transport, which is robust at a cytoplasmic pH of 7.6, the K(1/2) for extracellular protons decreases only a factor of 0.4 when maximal activity is decreased fivefold by reducing cytoplasmic Na. With 140 mM of extracellular Na and no cytoplasmic Na, the K(1/2) for cytoplasmic protons is 50 nM (pH 7.3; Hill coefficient, 1.5), and activity decreases only 25% with extracellular acidification from 8.5 to 7.2. Most data can be reconstructed with two very different coupled dimer models. In one model, monomers operate independently at low cytoplasmic pH but couple to translocate two ions in "parallel" at alkaline pH. In the second "serial" model, each monomer transports two ions, and translocation by one monomer allosterically promotes translocation by the paired monomer in opposite direction. We conclude that a large fraction of mammalian Na/H activity may occur with a 2Na/2H stoichiometry.
Resumo:
For improving the identification of potential heparin impurities such as oversulfated chondroitin sulfate (OSCS) the standard 2D (1)H-(1)H NMR NOESY was applied. Taking advantage of spin diffusion and adjusting the experimental parameters accordingly additional contaminant-specific signals of the corresponding sugar ring protons can easily be detected. These are usually hidden by the more intense heparin signals. Compared to the current 1D (1)H procedure proposed for screening commercial unfractionated heparin samples and focusing on the contaminants acetyl signals more informative and unique fingerprints may be obtained. Correspondingly measured (1)H fingerprints of a few potential impurities are given and their identification in two contaminated commercial heparin samples is demonstrated. The proposed 2D NOESY method is not intended to replace the current 1D method for detecting and quantifying heparin impurities but may be regarded as a valuable supplement for an improved and more reliable identification of these contaminants.
Resumo:
The Plasma and Supra-Thermal Ion Composition (PLASTIC) instrument is one of four experiment packages on board of the two identical STEREO spacecraft A and B, which were successfully launched from Cape Canaveral on 26 October 2006. During the two years of the nominal STEREO mission, PLASTIC is providing us with the plasma characteristics of protons, alpha particles, and heavy ions. PLASTIC will also provide key diagnostic measurements in the form of the mass and charge state composition of heavy ions. Three measurements (E/qk, time of flight, ESSD) from the pulse height raw data are used to characterize the solar wind ions from the solar wind sector, and part of the suprathermal particles from the wide-angle partition with respect to mass, atomic number and charge state. In this paper, we present a new method for flight data analysis based on simulations of the PLASTIC response to solar wind ions. We present the response of the entrance system / energy analyzer in an analytical form. Based on stopping power theory, we use an analytical expression for the energy loss of the ions when they pass through a thin carbon foil. This allows us to model analytically the response of the time of flight mass spectrometer to solar wind ions. Thus we present a new version of the analytical response of the solid state detectors to solar wind ions. Various important parameters needed for our models were derived, based on calibration data and on the first flight measurements obtained from STEREO-A. We used information from each measured event that is registered in full resolution in the Pulse Height Analysis words and we derived a new algorithm for the analysis of both existing and future data sets of a similar nature which was tested and works well. This algorithm allows us to obtain, for each measured event, the mass, atomic number and charge state in the correct physical units. Finally, an important criterion was developed for filtering our Fe raw flight data set from the pulse height data without discriminating charge states.