951 resultados para Pneumatic press


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a comparative study of the critical pickup and saltation velocities of particles in horizontal pipelines for pneumatic conveying design. A comparative study is performed using different existing correlations in the literature for the determination of the minimum velocity of transport as a function of the particle and pipe diameter, particle density, solid mass flow rate and particle sphericity. Their limitations and difficulties in predicting those critical velocities are analyzed. For the pickup velocity, an experimental study was also carried out in order to support the analysis. Recommendations are presented on the use of such correlations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It was studied the trapezius muscle and serratus anterior muscle in 24 male volunteers using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes, during the execution of four different modalities of military press exercises with open grip. The results showed that TS acted significantly in the modalities standing and sitting press behind neck, while SI acted in all the modalities, i.e., standing and sitting press behind neck and forward, justifying their inclusion as basic exercises for physical conditioning programmes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The researching centre mentioned was conceived em 1989, with the goal to study and implement the media of comunication by creating and effecting online printed medias for care institutions, schools and UNESP. The university has taken a give-and-take function between itself and the society. The founder of this group is Prof. Dr. Ricardo Nicola that since 1996 has established a link between university and society, using this centre for developing works that go over the university's borders. The group's work comprehends four different classes: literary , tecnical, journalism and advanced research . The literary one involves help and literary production for new authors, the tecnical helps in publishing theses; the journalism one is related to journal and medias in and out of the university; the advanced research one has is caracterized as a class between departments and branches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. The purpose of the study was to investigate the relationship between the total volume of load lifted (TVLL) and the rating of perceived exertion (RPE) measures during different resistance training (RT) schemes using the bench press exercise. Methods. The present study was divided into two experiments. In the first experiment, 18 healthy men performed three different RT schemes: a strength oriented scheme (SS), a muscular endurance oriented scheme (ES) and a hypertrophy oriented scheme (HS). TVLL was calculated for each scheme. Mean-RPE and session-RPE were assessed. In the second experiment, 23 men performed two resistance exercise bouts at different intensities (50 %-1RM and 75%-1RM) with matched TVLL. Mean-RPE and session-RPE were also assessed. Results. SS and HS showed higher TVLL and greater RPE scores as compared to ES (P<0.05). No significant difference was observed between SS and HS. It was verified significant positive correlations between TVLL and session-RPE (SS r=0.63, HS r=0.64, ES r=0.56; P<0.05), and between mean-RPE and TVLL (SS r=0.55, HS r=0.52, ES r=0.47; P<0.05) for all schemes. No differences were observed for mean-RPE, session-RPE and TVLL between the 50%-1RM and 75%1RM. Significant positive relationships between TVLL and session-RPE (50 %-1RM r=0.61, 75 %-1RM r=0.66; p<0.05) and between TVLL and mean-RPE (50 %-1RM r=0.51, 75%1RM r=0.49; P<0.05) were observed. Conclusion. The results of this study have shown that the TVLL in RT influences RPE measures. These findings corroborates the existence of a relationship between total work performed (external training load) and perception of effort (internal training load).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ferreira, SLA, Panissa, VLG, Miarka, B, and Franchini, E. Postactivation potentiation: effect of various recovery intervals on bench press power performance. J Strength Cond Res 26(3): 739-744, 2012-Postactivation potentiation (PAP) is a strategy used to improve performance in power activities. The aim of this study was to determine if power during bench press exercise was increased when preceded by 1 repetition maximum (1RM) in the same exercise and to determine which time interval could optimize PAP response. For this, 11 healthy male subjects (age, 25 +/- 4 years; height, 178 +/- 6 cm; body mass, 74 +/- 8 kg; bench press 1RM, 76 +/- 19 kg) underwent 6 sessions. Two control sessions were conducted to determine both bench press 1RM and power (6 repetitions at 50% 1RM). The 4 experimental sessions were composed of a 1RM exercise followed by power sets with different recovery intervals (1, 3, 5, and 7 minutes), performed on different days, and determined randomly. Power values were measured via Peak Power equipment (Cefise, Nova Odessa, Sao Paulo, Brazil). The conditions were compared using an analysis of variance with repeated measures, followed by a Tukey test. The significance level was set at p < 0.05. There was a significant increase in PAP in concentric contractions after 7 minutes of recovery compared with the control and 1-minute recovery conditions (p < 0.05). Our results indicated that 7 minutes of recovery has generated an increase in PAP in bench press and that such a strategy could be applied as an interesting alternative to enhance the performance in tasks aimed at increasing upper-body power performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN] Information about anaerobic energy production and mechanical efficiency that occurs over time during short-lasting maximal exercise is scarce and controversial. Bilateral leg press is an interesting muscle contraction model to estimate anaerobic energy production and mechanical efficiency during maximal exercise because it largely differs from the models used until now. This study examined the changes in muscle metabolite concentration and power output production during the first and the second half of a set of 10 repetitions to failure (10RM) of bilateral leg press exercise. On two separate days, muscle biopsies were obtained from vastus lateralis prior and immediately after a set of 5 or a set of 10 repetitions. During the second set of 5 repetitions, mean power production decreased by 19% and the average ATP utilisation accounted for by phosphagen decreased from 54% to 19%, whereas ATP utilisation from anaerobic glycolysis increased from 46 to 81%. Changes in contraction time and power output were correlated to the changes in muscle Phosphocreatine (PCr; r = -0.76; P<0.01) and lactate (r = -0.91; P<0.01), respectively, and were accompanied by parallel decreases (P<0.01-0.05) in muscle energy charge (0.6%), muscle ATP/ADP (8%) and ATP/AMP (19%) ratios, as well as by increases in ADP content (7%). The estimated average rate of ATP utilisation from anaerobic sources during the final 5 repetitions fell to 83% whereas total anaerobic ATP production increased by 9% due to a 30% longer average duration of exercise (18.4 +/- 4.0 vs 14.2 +/- 2.1 s). These data indicate that during a set of 10RM of bilateral leg press exercise there is a decrease in power output which is associated with a decrease in the contribution of PCr and/or an increase in muscle lactate. The higher energy cost per repetition during the second 5 repetitions is suggestive of decreased mechanical efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Programa de doctorado: Ciencias de la actividad física, salud y rendimiento deportivo

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Particle concentration is a principal factor that affects erosion rate of solid surfaces under particle impact, such as pipe bends in pneumatic conveyors; it is well known that a reduction in the specific erosion rate occurs under high particle concentrations, a phenomenon referred to as the “shielding effect”. The cause of shielding is believed to be increased likelihood of inter-particulate collisions, the high collision probability between incoming and rebounding particles reducing the frequency and the severity of particle impacts on the target surface. In this study, the effects of particle concentration on erosion of a mild steel bend surface have been investigated in detail using three different particulate materials on an industrial scale pneumatic conveying test rig. The materials were studied so that two had the same particle density but very different particle size, whereas two had very similar particle size but very different particle density. Experimental results confirm the shielding effect due to high particle concentration and show that the particle density has a far more significant influence than the particle size, on the magnitude of the shielding effect. A new method of correcting for change in erosivity of the particles in repeated handling, to take this factor out of the data, has been established, and appears to be successful. Moreover, a novel empirical model of the shielding effects has been used, in term of erosion resistance which appears to decrease linearly when the particle concentration decreases. With the model it is possible to find the specific erosion rate when the particle concentration tends to zero, and conversely predict how the specific erosion rate changes at finite values of particle concentration; this is critical to enable component life to be predicted from erosion tester results, as the variation of the shielding effect with concentration is different in these two scenarios. In addition a previously unreported phenomenon has been recorded, of a particulate material whose erosivity has steadily increased during repeated impacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The new knee test rig developed in University of Bologna used pneumatic cylinder as actuator system. Specific characterization and modelling about the pneumatic cylinder and the related devices are needed in better controlling the test rig. In this thesis, an experimental environment for the related device is set up with data acquisition system using Real-time Windows Target, Simulink, MatLab. Based on the experimental data, a fitted model for the pneumatic cylinder friction is found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ROTEM(®) is considered a helpful point-of-care device to monitor blood coagulation. Centrally performed analysis is desirable but rapid transport of blood samples and real-time transmission of graphic results are an important prerequisite. The effect of sample transport through a pneumatic tube system on ROTEM(®) results is unknown. The aims of the present work were (i) to determine the influence of blood sample transport through a pneumatic tube system on ROTEM(®) parameters compared to manual transportation, and (ii) to verify whether graphic results can be transmitted on line via virtual network computing using local area network to the physician in charge of the patient.