857 resultados para Plastic hinge calibration
Resumo:
We analyzed the differences between irrigated and non-irrigated plants of three congeneric Styrax species that present distinct distribution patterns in the physiognomies of the Cerrado vegetation in Brazil. Styrax ferrugineus showed a stomatal conductance (gs) unresponsive to soil water deficit in potted plants. This may explain the high gas exchange and photochemical efficiency found in this species, which is well adapted to the Cerrado sensu stricto (s. str.), a savanna-type vegetation. S. camporum, which is widely distributed in the Cerrado sensu lato (s. l.) areas, was the only species that exhibited increased intrinsic water use efficiency on the days of maximum water deficit. This result distinguishes S. camporum from S. pohlii, which is a forest species, since the gs of both species decreased during the days of maximum water stress. In contrast to other studies, we propose that instantaneously measured traits, such as leaf gas exchange rates and chlorophyll fluorescence, may be used to detect non-plastic performances in response to environmental stress, helping explain distinct geographical distributions of congeneric species in the Cerrado vegetation. © 2013 Springer-Verlag Berlin Heidelberg.
Resumo:
ABSTRACT: The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simultaneous determination of several chemical species. However, when this methodology is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high operational cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu2+, Mn2+ and Zn2+ in polyvitaminic and polymineral pharmaceutical formulations, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the preparation of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples-1 can be carried out with the proposed flow-batch analyser.
Resumo:
CONTEXTUALIZAÇÃO:O manuseio de materiais está ainda presente nos setores industriais e é associado a lesões na coluna lombar e membros superiores. A inserção de alças em caixas industriais é uma forma de reduzir os riscos relacionados à tarefa, porém a posição e a angulação das alças, que são fatores importantes para o conforto e segurança durante o manuseio, são ainda pouco investigadas objetivamente.OBJETIVOS:Comparar o manuseio de uma caixa comercial e de protótipos com alças e avaliar seus efeitos na postura de membros superiores, atividade elétrica muscular e percepção de agradabilidade em diferentes empunhaduras durante manuseio entre diferentes alturas.MÉTODO:Trinta e sete voluntários saudáveis avaliaram as alças dos protótipos que possibilitavam mudança nas posições (superior e inferior) e angulações (0°, 15° e 30º). Os movimentos dos punhos, cotovelos e ombros foram avaliados por meio da eletrogoniometria e inclinometria. A atividade elétrica muscular dos extensores do punho, bíceps braquial e porção superior do trapézio foi avaliada por um eletromiógrafo portátil. Os registros de movimento e atividade elétrica muscular foram sincronizados. Aspectos subjetivos de agradabilidade foram avaliados por meio de uma escala visual analógica.RESULTADOS E CONCLUSÕES:Os protótipos com alças inclinadas em 30° apresentaram as melhores avaliações de agradabilidade, posturas mais neutras de punho, menores níveis de atividade eletromiográfica do trapézio superior e menores ângulos de elevação dos braços. Os diferentes métodos de medida se mostraram complementares para a avaliação dos membros superiores durante as tarefas de manuseio.
Resumo:
Pós-graduação em Química - IQ
Resumo:
Vibration monitoring requires acceleration transducers capable of providing data with high precision. Accelerometers are the most frequently used vibration transducers. Their calibration plays an important role in measuring vibrations and is a key component in ensuring the integrity of the vibration measurement. For managing secondary calibration data of accelerometers, a database computer system was implemented. The implementation of this software has been an important step forward in providing a wide range of analysis and display tools. This paper reviews the main concepts involving accelerometer secondary calibration and describes the tool developed and the methods used in its development. (C) 2013 Academie des sciences. Published by Elsevier Masson SAS. All rights reserved.
Resumo:
Leaks in pipes are a common issue encountered in the water industry. Acoustic methods are generally successful in finding and locating leaks in metallic pipes, however, they are less effective when applied to plastic pipes. This is because leak-noise signals are heavily attenuated due to high damping in the pipe-wall and sound radiation into the soil. As result, high frequency leak noise does not travel long distances. To determine how far leak noise may travel in a pipe at any frequency, the attenuation of the wave responsible for leak noise propagation should be known. In this paper a new method to estimate this is described. The method is then applied to some measurements made on a bespoke pipe-test rig in the UK, and the results are compared with theoretical predictions.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Acoustic techniques have been used for many years to find and locate leaks in buried water distribution systems. Hydrophones and accelerometers are typically used as sensors. Although geophones could be used as well, they are not generally used for leak detection. A simple acoustic model of the pipe and the sensors has been proposed previously by some of the authors of this paper, and their model was used to explain some of the features observed in measurements. However, simultaneous measurements of a leak using all three sensor-types in controlled conditions for plastic pipes has not been reported to-date and hence they have not yet been compared directly. This paper fills that gap in knowledge. A set of measurements was made on a bespoke buried plastic water distribution pipe test rig to validate the previously reported analytical model. There is qualitative agreement between the experimental results and the model predictions in terms of the differing filtering properties of the pipe-sensor systems. A quality measure for the data is also presented, which is the ratio of the bandwidth over which the analysis is carried out divided by the centre frequency of this bandwidth. Based on this metric, the accelerometer was found to be the best sensor to use for the test rig described in this paper. However, for a system in which the distance between the sensors is large or the attenuation factor of the system is high, then it would be advantageous to use hydrophones, even though they are invasive sensors.
Resumo:
The establishment of laboratory colonies of ticks is often hampered by their lack of adaptation to alternative hosts. The aim of this study was to artificially feed partially engorged Dermacentor (Anocentor) nitens females through plastic tips, and to identify what are the optimal conditions of application of this technique to get as much as possible close to the natural conditions. The technique of artificial feeding through plastic tips allowed the engorgement of D. nitens ticks to a final weight within the normal range for the species. (C) 2014 Published by Elsevier GmbH.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (alpha = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In water distribution systems, old metallic pipes have been replaced by plastic pipes due to their deterioration over time. Although acoustic methods are effective in finding leaks in metallic pipes, they have been found to be problematic when applied to plastic pipes due to the high damping within the pipe wall and the surrounding medium. This is responsible for the leak signal not traveling long distances. Moreover, the leak energy in plastic pipes is generally located at a narrow frequency range located at low frequencies. However, the presence of resonances can narrow even more this frequency range. In order to minimise the influence of background noise and resonances on the calculation of the time delay estimate, band-pass filters are often used to supress undesirable frequency components of the noise. The objective of this paper is to investigate the influence of resonances in the pipe system (pipe, valves, connections and hydrants), on the time delay estimate calculated using acoustic signals. Analytical models and actual leak data collected in a bespoke rig located in the United Kingdom are used to investigate this feature.
Resumo:
In this research the aim was produce and evaluate a plastic composite using recycled polypropylene (PP) and fibers from sugarcane bagasse residues (SC), without the use of additives. This analysis was based on laboratorial tests for physical and mechanical characterization, according to the standards ASTM D256-00, D638-101 and D570-98 were analyzed: water absorption, thickness swelling, impact resistance, tensile strength and its correspondent deformation. For comparison it was elaborated three different compositions: 100% PP; 80% PP+20%SC; 70%PP+30%SC. The results indicate a positive correlation with the content of fiber and water absorption and thickness swelling. In the tension tests, the composites with fibers increase the value of resistance for physical efforts, bringing advantages as durability and integrity of the material, showing a viability of the composites.
Resumo:
In this research the aim was produce and evaluate a plastic composite using recycled polypropylene (PP) and fibers from sugarcane bagasse residues (SC), without the use of additives. This analysis was based on laboratorial tests for physical and mechanical characterization, according to the standards ASTM D256-00, D638-101 and D570-98 were analyzed: water absorption, thickness swelling, impact resistance, tensile strength and its correspondent deformation. For comparison it was elaborated three different compositions: 100% PP; 80% PP+20%SC; 70%PP+30%SC. The results indicate a positive correlation with the content of fiber and water absorption and thickness swelling. In the tension tests, the composites with fibers increase the value of resistance for physical efforts, bringing advantages as durability and integrity of the material, showing a viability of the composites.