652 resultados para Nasolacrimal duct


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A literature survey and a theoretical study were performed to characterize residential chimney conditions for flue gas flow measurements. The focus is on Pitot-static probes to give sufficient basis for the development and calibration of a velocity pressure averaging probe suitable for the continuous dynamic (i.e. non steady state) measurement of the low flow velocities present in residential chimneys. The flow conditions do not meet the requirements set in ISO 10780 and ISO 3966 for Pitot-static probe measurements, and the methods and their uncertainties are not valid. The flow velocities in residential chimneys from a heating boiler under normal operating condi-tions are shown to be so low that they in some conditions result in voiding the assumptions of non-viscous fluid justifying the use of the quadratic Bernoulli equation. A non-linear Reynolds number dependent calibration coefficient that is correcting for the viscous effects is needed to avoid significant measurement errors. The wide range of flow velocity during normal boiler operation also results in the flow type changing from laminar, across the laminar to turbulent transition region, to fully turbulent flow, resulting in significant changes of the velocity profile during dynamic measurements. In addition, the short duct lengths (and changes of flow direction and duct shape) used in practice are shown to result in that the measurements are done in the hydrodynamic entrance region where the flow velocity profiles most likely are neither symmetrical nor fully developed. A measurement method insensitive to velocity profile changes is thus needed, if the flow velocity profile cannot otherwise be determined or predicted with reasonable accuracy for the whole measurement range. Because of particulate matter and condensing fluids in the flue gas it is beneficial if the probe can be constructed so that it can easily be taken out for cleaning, and equipped with a locking mechanism to always ensure the same alignment in the duct without affecting the calibration. The literature implies that there may be a significant time lag in the measurements of low flow rates due to viscous effects in the internal impact pressure passages of Pitot probes, and the significance in the discussed application should be studied experimentally. The measured differential pressures from Pitot-static probes in residential chimney flows are so low that the calibration and given uncertainties of commercially available pressure transducers are not adequate. The pressure transducers should be calibrated specifically for the application, preferably in combination with the probe, and the significance of all different error sources should be investigated carefully. Care should be taken also with the temperature measurement, e.g. with averaging of several sensors, as significant temperature gradients may be present in flue gas ducts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hybrid Photovoltaic Thermal (PVT) collectors are an emerging technology that combines PV and solar thermal systems in a single solar collector producing heat and electricity simultaneously. The focus of this thesis work is to evaluate the performance of unglazed open loop PVT air system integrated on a garage roof in Borlänge. As it is thought to have a significant potential for preheating ventilation of the building and improving the PV modules electrical efficiency. The performance evaluation is important to optimize the cooling strategy of the collector in order to enhance its electrical efficiency and maximize the production of thermal energy. The evaluation process involves monitoring the electrical and thermal energies for a certain period of time and investigating the cooling effect on the performance through controlling the air mass flow provided by a variable speed fan connected to the collector by an air distribution duct. The distribution duct transfers the heated outlet air from the collector to inside the building. The PVT air collector consists of 34 Solibro CIGS type PV modules (115 Wp for each module) which are roof integrated and have replaced the traditional roof material. The collector is oriented toward the south-west with a tilt of 29 ᵒ. The collector consists of 17 parallel air ducts formed between the PV modules and the insulated roof surface. Each air duct has a depth of 0.05 m, length of 2.38 m and width of 2.38 m. The air ducts are connected to each other through holes. The monitoring system is based on using T-type thermocouples to measure the relevant temperatures, air sensor to measure the air mass flow. These parameters are needed to calculate the thermal energy. The monitoring system contains also voltage dividers to measure the PV modules voltage and shunt resistance to measure the PV current, and AC energy meters which are needed to calculate the produced electrical energy. All signals recorded from the thermocouples, voltage dividers and shunt resistances are connected to data loggers. The strategy of cooling in this work was based on switching the fan on, only when the difference between the air duct temperature (under the middle of top of PV column) and the room temperature becomes higher than 5 °C. This strategy was effective in term of avoiding high electrical consumption by the fan, and it is recommended for further development. The temperature difference of 5 °C is the minimum value to compensate the heat losses in the collecting duct and distribution duct. The PVT air collector has an area of (Ac=32 m2), and air mass flow of 0.002 kg/s m2. The nominal output power of the collector is 4 kWppv (34 CIGS modules with 115 Wppvfor each module). The collector produces thermal output energy of 6.88 kWth/day (0.21 kWth/m2 day) and an electrical output energy of 13.46 kWhel/day (0.42 kWhel/m2 day) with cooling case. The PVT air collector has a daily thermal energy yield of 1.72 kWhth/kWppv, and a daily PV electrical energy yield of 3.36 kWhel /kWppv. The fan energy requirement in this case was 0.18 kWh/day which is very small compared to the electrical energy generated by the PV collector. The obtained thermal efficiency was 8 % which is small compared to the results reported in literature for PVT air collectors. The small thermal efficiency was due to small operating air mass flow. Therefore, the study suggests increasing the air mass flow by a factor of 25. The electrical efficiency was fluctuating around 14 %, which is higher than the theoretical efficiency of the PV modules, and this discrepancy was due to the poor method of recording the solar irradiance in the location. Due to shading effect, it was better to use more than one pyranometer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Biliary tract infection is associated with high mortality. This study investigated the effect of glucocorticoid pretreatment on lipopolysaccharide (LPS)-induced cholangitis. Methods: Rats undergoing either sham operation or ligation of the extrahepatic bile duct (BDL) for 2 weeks were randomly assigned to receive intravenous injections of dexamethasone (DX) or normal saline (NS) prior to infusing LPS into the biliary tract. The plasma levels of tumor necrosis factor-α (TNFα), chemokines monocyte chemoattractant protein-1 (MCP-1) and macrophage inflammatory protein-2 (MIP-2) as well as liver mRNA expression of MCP-1 and MIP-2 were determined. Infiltration of monocytes, Kupffer cells, and neutrophils in rat liver were studied with immunohistochemistry. Oxidative liver injury was measured by the malondialdehyde (MDA) content. Results: Dexamethasone pretreatment resulted in significantly decreased plasma levels of TNFα at 1 hour, MCP-1 and MIP-2 at 2 and 3 hours, and decreased liver MCP-1 mRNA expression at 3 hours following LPS infusion in BDL-DX rats than in BDL-NS rats. The number of inflammatory cells in the liver was significantly different between sham- and BDL-treated rats but was not affected by DX pretreatment. Pretreatment with DX resulted in significantly decreased liver MDA contents in the BDL-DX group than that in the BDL-NS group. Jaundiced rats pretreated with 5 mg DX prior to infusion of 1 g of LPS were 6.8 times more likely to survive than those that were not pretreated. Conclusions: Pretreatment of jaundiced, LPS-treated rats with a  supraphysiological dose of dexamethasone may rescue their lives by suppression of chemokine expression and alleviation of oxidative liver injury.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The pharmacokinetics of recombinant human endostatin (rh-Endo) has not been established in the rat, although this species of animal is commonly used in the pharmacological studies of rh-Endo. This study aimed to investigate the pharmacokinetics, tissue distribution, and excretion of rh-Endo in rats. 125I-radiolabeled rh-Endo was administered to healthy rats by intravenous (i.v) bolus injection at 1.5, 4.5 and 13.5 mg/kg. The maximum plasma concentration (Cmax) and area under the plasma concentration versus time curve (AUC) of rh-Endo increased proportionally with the increase of the dosage. There were no significant differences in total body clearance (CL) and elimination half-life (t1/2beta) of rh-Endo among the three dosages used. A 93.5% and 2.2% of the radioactivity was recovered in the urine and feces, respectively, in bile-duct intact rats; whereas only 0.1% of the total radioactivity was excreted into the bile in bile-duct cannulated rats. rh-Endo was rapidly and widely distributed in the liver, kidneys, spleen and lungs. Furthermore, a significant allometric relationship between CL, but not volume of distribution (Vd) and t1/2beta of rh-Endo, and the body weight was observed across mouse, rat and monkey, with the predicted values in humans significantly lower than those observed in cancer patients. rh-Endo exhibited a linear pharmacokinetics in rats and it is mainly excreted through the urine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose Combination of COL-3, a matrix metalloproteinase inhibitor, and doxorubicin (DOX) might be a promising anticancer regimen. The present study was to examine the potential pharmacokinetic interactions and toxicity profile following their coadministration in rats.
Methods Normal rats were treated with single agent or different combinations with oral or intravenous COL-3 and DOX, and the bile-duct cannulated (BDC) rats received oral COL-3 plus DOX. In a separate disposition study, the effects of DOX on the biliary, urinary, and fecal excretion of COL-3 were examined. In addition, the effects of DOX on in vitro protein binding, metabolism, and transport of COL-3 across Caco-2 monolayers were investigated.
Results COL-3 did not affect the pharmacokinetics of DOX in rats. However, treatment with DOX significantly decreased the oral absorption, and prolonged the elimination, of COL-3 in the normal rats, but not in the BDC rats. DOX did not alter the biliary and urinary excretion of COL-3, but significantly decreased the fecal excretion of COL-3. DOX significantly enhanced the basolateral to apical flux of COL-3 across Caco-2 monolayers, but had no apparent effects on the protein binding and metabolism of COL-3. The combination of DOX with oral COL-3 did not significantly (p > 0.05) increase the acute diarrhea score and intestinal damage compared to rats receiving DOX alone.
Conclusions These results indicated that DOX altered the oral absorption and elimination of COL-3, largely resulting from gastrointestinal toxicity caused by biliary excretion of DOX. Further studies are required to explore the efficacy and optimized dosage regimen of this promising combination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background
Intervention of the biliary system is frequently done in patients with obstructive jaundice and is associated with significant morbidity and mortality. The pathogenesis is unknown.
Materials and methods
A rat model of bile duct ligation (BDL) for 2 weeks was established in which biliary intervention was feasible by injection of normal saline through an indwelling catheter in the bile ducts. Plasma levels of C-C chemokine MCP-1 and C-X-C chemokine MIP-2 were measured by using ELISA. Blood monocytes, Kupffer cells, and neutrophils in the liver were characterized with antibodies to ED1, ED2, and myeloperoxidase (MPO). Lipid peroxidation was measured by malondialdehyde contents and apoptosis by TUNEL stain of the liver.
Results
Biliary intervention resulted in an increase of plasma MCP-1 and MIP-2 proteins by 1 h, which declined to normal level by 3 h in both sham and BDL rats. The levels in BDL rats were significantly higher than in sham at most points. There was a transient increase of ED1- and ED2-positive cells and MPO-staining cells in sham rat liver by 1 h after intervention. ED2-positive cells increased significantly by 1 h, while ED1- and MPO-positive cells decreased, yet insignificantly after intervention in BDL rats. The cell counts in BDL were constantly higher than in sham. Malondialdehyde increased precipitously in BDL by 3 h and was significantly higher than in sham throughout the study period. Parenchymal liver injury, manifested by elevated ALT, as well as apoptosis and necrosis of liver cells, was significantly increased in BDL rats, but not in sham rats.
Conclusion
Biliary intervention augments chemokine expression, precipitates lipid peroxidation, and aggravates liver injury in cholestatic rats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A wall in the Sheet Metal Department at the New York Trade School shows many examples of duct work, pipe, and decorative metal work that students learn to produce. Black and white photograph that is starting to fade.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 1946 graduate of the Sheet Metal Department, Thomas Carlough is pictured at work at the Triangle Sheet Metal Works, Inc. Original caption reads, "Thomas Carlough - Sheet Metal 1946. The Sheet Metal Draftsman lays out the duct work etc, for the ventilation and Air Conditioning of buildings." Black and white photograph with caption adhered to reverse.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

No próximo ano, completam-se 40 anos desde a primeira tentativa de transplante hepático (TxH) em seres humanos. Há quase 20 anos, o transplante (Tx) tornou-se uma opção terapêutica real para os pacientes portadores de doença hepática terminal. Atualmente, o TxH é o tratamento de escolha para diversas enfermidades hepáticas, agudas ou crônicas. Dos transplantes realizados na Europa ou nos EUA, em torno de 12% dos pacientes são crianças e adolescentes. No Brasil, 20,9% dos pacientes transplantados de fígado em 2001 tinham até 18 anos de idade e, destes, 60,7% tinham 5 anos ou menos. O objetivo do TxH é a manutenção da vida dos pacientes com doença hepática irreversível, e a principal forma de avaliação de sucesso é a sobrevida após o Tx. A primeira semana que se segue ao TxH, apesar dos excelentes progressos dos últimos anos, continua sendo o período mais crítico. A maioria dos óbitos ou das perdas do enxerto ocorrem nas primeiras semanas, em particular, nos primeiros 7 dias de TxH. Diversos fatores de risco para o resultado do TxH podem ser identificados na literatura, porém há poucos estudos específicos do Tx pediátrico. As crianças pequenas apresentam características particulares que os diferenciam do Tx nos adultos e nas crianças maiores. Com o objetivo de identificar fatores de risco para o óbito nos 7 primeiros dias após os transplantes hepáticos eletivos realizados em 45 crianças e adolescentes no Hospital de Clínicas de Porto Alegre entre março de 1995 e agosto de 2001, foi realizado um estudo de caso-controle. Entre os 6 casos (13,3%) e os 39 controles foram comparadas características relacionadas ao receptor, ao doador e ao procedimento cirúrgico e modelos prognósticos. Das variáveis relacionadas ao receptor, o gênero, o escore Z do peso e da estatura para a idade, a atresia de vias biliares, a cirurgia abdominal prévia, a cirurgia de Kasai, a história de ascite, de peritonite bacteriana espontânea, de hemorragia digestiva e de síndrome hepatopulmonar, a albuminemia, o INR, o tempo de tromboplastina parcial ativada e o fator V não foram associados com o óbito na primeira semana. A mortalidade inicial foi maior nas crianças com menor idade (p=0,0035), peso (p=0,0062) e estatura (p<0,0001), bilirrubinemia total (BT) (p=0,0083) e bilirrubinemia não conjugada (BNC) (p=0,0024) elevadas, e colesterolemia reduzida (p=0,0385). Os receptores menores de 3 anos tiveram um risco 25,5 vezes maior de óbito que as crianças maiores (IC 95%: 1,3–487,7). A chance de óbito após o Tx dos pacientes com BT superior a 20 mg/dL e BNC maior que 6 mg/dL foi 7,8 (IC95%: 1,2–50,1) e 12,7 (IC95%: 1,3–121,7) vezes maior que daqueles com níveis inferiores, respectivamente. Das características relacionadas ao doador e ao Tx, as variáveis gênero, doador de gênero e grupo sangüíneo ABO não idênticos ao do receptor, razão peso do doador/receptor, causa do óbito do doador, enxerto reduzido, tempo em lista de espera e experiência do Programa não foram associados com o óbito nos primeiros 7 dias. Transplantes com enxertos de doadores de idade até 3 anos, ou de peso até 12 Kg representaram risco para o óbito dos receptores 6,8 (IC95%: 1,1–43,5) e 19,3 (IC95%: 1,3–281,6) vezes maior, respectivamente. O tempo de isquemia total foi em média de 2 horas maior nos transplantes dos receptores não sobreviventes (p=0,0316). Os modelos prognósticos Child-Pugh, Rodeck e UNOS não foram preditivos do óbito. Os pacientes classificados como alto risco no modelo de Malatack apresentaram razão de chances para o óbito 18,0 (IC95%: 1,2–262,7) vezes maior que aqueles com baixo risco. A mortalidade na primeira semana foi associada a valores elevados do escore PELD. O risco de óbito foi de 11,3 (IC95%: 1,2–107,0) nas crianças com valor do PELD maior que 10. As crianças pequenas e com maior disfunção hepática apresentaram maior risco de óbito precoce. Doador de pequeno porte e prolongamento do tempo de isquemia também foram associados à mortalidade. Somente os modelos de Malatack e PELD foram preditivos da sobrevida.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta dissertação de mestrado considera a transferência de calor combinando convecção e radiação térmica no escoamento de gases participantes em dutos de seção circular. Partindo de uma metodologia geral, o trabalho enfoca principalmente os casos típicos de aplicação em geradores de vapor fumotubulares de pequeno e médio porte, em que gases em alta temperatura escoam através de um tubo mantido em temperatura uniforme. O escoamento é turbulento e o perfil de velocidade é plenamente desenvolvido desde a entrada do duto. A temperatura do gás, contudo, é uniforme na entrada, considerando-se a região de desenvolvimento térmico. Duas misturas de gases são tratadas, ambas constituídas por dióxido de carbono, vapor d’água e nitrogênio, correspondendo a produtos típicos da combustão estequiométrica de óleo combustível e metano. As propriedades físicas dos gases são admitidas uniformes em todo o duto e calculadas na temperatura de mistura média, enquanto que as propriedades radiantes são modeladas pela soma-ponderada-de-gases-cinzas. O campo de temperatura do gás é obtido a partir da solução da equação bidimensional da conservação da energia, sendo os termos advectivos discretizados através do método de volumes de controle com a função de interpolação Flux-Spline; as trocas de energia radiantes são avaliadas por meio do método das zonas, onde cada zona de radiação corresponde a um volume de controle. Em um primeiro passo, a metodologia é verificada pela comparação com resultados apresentados na literatura para a transferência de calor envolvendo apenas convecção e combinando convecção com radiação. Em seguida, discutem-se alguns efeitos da inclusão da radiação térmica, por exemplo, no número de Nusselt convectivo e na temperatura de mistura do gás. Finalmente, são propostas correlações para o número de Nusselt total, que leva em conta tanto a radiação quanto a convecção. Essa etapa exige inicialmente uma análise dos grupos adimensionais que governam o processo radiante para redução do número elevado de parâmetros independentes. As correlações, aplicáveis a situações encontradas em geradores de vapor fumotubulares de pequeno e médio porte, são validadas estatisticamente pela comparação com os resultados obtidos pela solução numérica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spontaneous perforation of the common bile duct is rare. It happens predominantly in children and it is related to obstructive disease of the biliary tract. We present a case of an 18 year-old male patient, with ulcerative rectocolitis associated with malignant tumor of the head of pancreas. The patient developed an acute abdomen syndrome and laparotomy, a spontaneous perforation of common bile duct was evidenced. The authors make a revision of the clinical aspects of that pathology

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O quilotórax corresponde ao acúmulo de fluido linfático em um ou em ambos os espaços pleurais, resultante do extravasamento de linfa do ducto torácico ou de uma de suas divisões principais. Este pode estar associado à ascite quilosa em pacientes com distúrbios linfáticos sistêmicos, como na linfangiectasia, em decorrência de defeitos no transporte linfático-venoso do quilo da cavidade torácica para a circulação sistêmica. A linfangiectasia intestinal é um distúrbio obstrutivo que envolve o sistema linfático do órgão e revela-se como a causa mais comum de enteropatias associadas à má absorção e perda de proteínas em cães. São apresentados no presente relato o controle clínico com o uso de dieta caseira com baixa gordura e a quantificação da função digestiva, por meio da determinação da digestibilidade do alimento, em um cão acometido por quilotórax secundário à linfangiectasia intestinal. A dieta caseira incluiu arroz, peito de frango, cenoura, carbonato de cálcio, levedura de cerveja, suplemento vitamínico e mineral e sal. O ensaio de digestibilidade foi conduzido pelo método de coleta total de fezes. A dieta caseira foi eficaz em interromper o acúmulo de efusão quilosa torácica, restabelecer as concentrações de proteína total e albumina e promover ganho de peso no paciente. Os resultados da digestibilidade demonstraram menor aproveitamento de todos os nutrientes no cão com linfangiectasia em relação ao controle sadio.