967 resultados para Maxwell, Equações de
Resumo:
For a series of six-coordinate Ru(II)(CO)L or Rh(III)(X–)L porphyrins which are facially differentiated by having a naphthoquinol- or hydroquinol-containing strap across one face, we show that ligand migration from one face to the other can occur under mild conditions, and that ligand site preference is dependent on the nature of L and X–. For bulky nitrogen-based ligands, the strap can be displaced sideways to accommodate the ligand on the same side as the strap. For the ligand pyrazine, we show 1 H NMR evidence for monodentate and bidentate binding modes on both faces, dependent on ligand concentration and metalloporphyrin structure, and that inter-facial migration is rapid under normal conditions. For monodentate substituted pyridine ligands there is a site dependence on structure, and we show clear evidence of dynamic ligand migration through a series of ligand exchange reactions.
Resumo:
There is no doubt that fraud in relation to land transactions is a problem that resonates amongst land academics, practitioners, and stakeholders involved in conveyancing. As each land registration and conveyancing process increasingly moves towards a fully electronic environment, we need to make sure that we understand and guard against the frauds that can occur. What this paper does is examine the types of fraud that have occurred in paper-based conveyancing systems in Australia and considers how they might be undertaken in the National Electronic Conveyancing System (NECS) that is currently under development. Whilst no system can ever be infallible, it is suggested that by correctly imposing the responsibility for identity verification on the appropriate individual, the conveyancing system adopted can achieve the optimum level of fairness in terms of allocation of responsibility and loss. As we sit on the cusp of a new era of electronic conveyancing, the framework suggested here provides a model for minimising the risks of forged mortgages and appropriately allocating the loss. Importantly it also recognises that the electronic environment will see new opportunities for those with criminal intent to undermine the integrity of land transactions. An appreciation of this now, can see the appropriate measures put in place to minimise the risk.
Resumo:
Background: Distal-to-proximal technique has been recommended for anti-cancer therapy administration. There is no evidence to suggest that a 24-hour delay of treatment is necessary for patients with a previous uncomplicated venous puncture proximal to the administration site. Objectives: This study aims to identify if the practice of 24-hour delay between a venous puncture and subsequent cannulation for anti-cancer therapies at a distal site is necessary for preventing extravasation. Methods: A prospective cohort study was conducted with 72 outpatients receiving anti-cancer therapy via an administration site distal to at least one previous uncomplicated venous puncture on the same arm in a tertiary cancer centre in Australia. Participants were interviewed and assessed at baseline data before treatment and on day 7 for incidence of extravasation/phlebitis. Results: Of 72 participants with 99 occasions of treatment, there was one incident of infiltration (possible extravasation) at the venous puncture site proximal to the administration site and two incidents of phlebitis at the administration site. Conclusions: A 24 hour delay is unnecessary if an alternative vein can be accessed for anti-cancer therapy after a proximal venous puncture. Implications for practice: Extravasation can occur at a venous puncture site proximal to an administration site in the same vein. However, the nurse can administer anti-cancer therapy at a distal site if the nurse can confidently determine the vein of choice is not in any way connected to the previous puncture site through visual inspection and palpation.
Resumo:
Organisations within the not-for-profit sector provide services to individuals and groups that government and for-profit organisations cannot or will not consider. The not-for-profit sector has come to be a vibrant and rich agglomeration of services and programs that operate under a myriad of philosophical stances, service orientation, client groupings and operational capacities. In Australia these organisations and services are providing social support and service assistance to many people in the community; often targeting their assistance to the most difficult of clients. Initially, in undertaking this role, the not-for-profit sector received limited sponsorship from government. Over time governments assumed greater responsibility in the form of service grants to particular groups: ‘the worthy poor’. More recently, they have entered into contractual service agreements with the not-for-profit sector, which specify the nature of the outcomes to be achieved and, to a degree, the way in which the services will be provided. A consequence of this growing shift to a more marketised model of service contracting, often offered-up under the label of enhanced collaborative practice, has been increased competitiveness between agencies that had previously worked well together (Keast and Brown, 2006). Another trend emerging from the market approach is the entrance of for-profit providers. These larger organisations have higher levels of organisational capacity with considerable organisational slack to allow them to adopt new service roles. Shaped almost as ‘shadow governments’ they appear to be a strong preference for governments looking for greater accountability of outcomes and an easier way to control the interaction with the conventional not-for-profit sector. The question is will governments’ apparent preference for larger organisational arrangements lead to the demise of the vibrancy of the not-for-profit sector and impact on service provision to those people who fall outside of the remit of the new service providers? To address this issue, this paper uses information gleaned from a state-wide survey of not-for-profit organisations in Queensland, Australia which included organisational size, operational scope, funding arrangements and governance/management approaches. Supplementing this information is qualitative data derived from 17 focus groups and 120 interviews conducted over ten years of study of this sector. The findings contribute to greater understanding of the practice and theory of the future provision of social services.
Resumo:
Purpose – This paper aims to outline the challenges and tasks involved in a organising and marketing a new venture from conception to sales. It presents an interesting situation with which readers can identify and apply knowledge and skills associated with entrepreneurship and marketing and link this with the key learning objectives of a new venture marketing study unit. Design/methodology/approach – The case is constructed around key principles of marketing and entrepreneurship linked to a description of a contemporary venture written from a participant observer perspective supplemented with knowledge from interviews and archival research. Findings – The case shows how effective a diligent, creative approach to developing and selling a new venture can be. It demonstrates that effective marketing requires more than rote adoption of basic principles – it requires creative thinking and enterprising adaption of relevant principles to address the specific and well defined objectives of the venture. Research limitations/implications – The case is not intended to prescribe a particular marketing method or process; rather it is meant to stimulate creativity in the use of marketing knowledge and skills. Practical implications – The case represents an effective resource for both formal and informal teaching and learning. It demonstrates the requirement for innovative and creative adoption of marketing concepts to fit the demands of a new venture. Originality/value – The case specifically addresses an identified need for learning resources and information tailored to the area of entrepreneurial new venture marketing.
Resumo:
Purpose: James Clerk Maxwell is usually recognized as being the first, in 1854, to consider using inhomogeneous media in optical systems. However, some fifty years earlier Thomas Young, stimulated by his interest in the optics of the eye and accommodation, had already modeled some applications of gradient-index optics. These applications included using an axial gradient to provide spherical aberration-free optics and a spherical gradient to describe the optics of the atmosphere and the eye lens. We evaluated Young’s contributions. Method: We attempted to derive Young’s equations for axial and spherical refractive index gradients. Raytracing was used to confirm accuracy of formula. Results: We did not confirm Young’s equation for the axial gradient to provide aberration-free optics, but derived a slightly different equation. We confirmed the correctness of his equations for deviation of rays in a spherical gradient index and for the focal length of a lens with a nucleus of fixed index surrounded by a cortex of reducing index towards the edge. Young claimed that the equation for focal length applied to a lens with part of the constant index nucleus of the sphere removed, such that the loss of focal length was a quarter of the thickness removed, but this is not strictly correct. Conclusion: Young’s theoretical work in gradient-index optics received no acknowledgement from either his contemporaries or later authors. While his model of the eye lens is not an accurate physiological description of the human lens, with the index reducing least quickly at the edge, it represented a bold attempt to approximate the characteristics of the lens. Thomas Young’s work deserves wider recognition.
Resumo:
Volume measurements are useful in many branches of science and medicine. They are usually accomplished by acquiring a sequence of cross sectional images through the object using an appropriate scanning modality, for example x-ray computed tomography (CT), magnetic resonance (MR) or ultrasound (US). In the cases of CT and MR, a dividing cubes algorithm can be used to describe the surface as a triangle mesh. However, such algorithms are not suitable for US data, especially when the image sequence is multiplanar (as it usually is). This problem may be overcome by manually tracing regions of interest (ROIs) on the registered multiplanar images and connecting the points into a triangular mesh. In this paper we describe and evaluate a new discreet form of Gauss’ theorem which enables the calculation of the volume of any enclosed surface described by a triangular mesh. The volume is calculated by summing the vector product of the centroid, area and normal of each surface triangle. The algorithm was tested on computer-generated objects, US-scanned balloons, livers and kidneys and CT-scanned clay rocks. The results, expressed as the mean percentage difference ± one standard deviation were 1.2 ± 2.3, 5.5 ± 4.7, 3.0 ± 3.2 and −1.2 ± 3.2% for balloons, livers, kidneys and rocks respectively. The results compare favourably with other volume estimation methods such as planimetry and tetrahedral decomposition.
Resumo:
A system is described for calculating volume from a sequence of multiplanar 2D ultrasound images. Ultrasound images are captured using a video digitising card (Hauppauge Win/TV card) installed in a personal computer, and regions of interest transformed into 3D space using position and orientation data obtained from an electromagnetic device (Polbemus, Fastrak). The accuracy of the system was assessed by scanning 10 water filled balloons (13-141 ml), 10 kidneys (147 200 ml) and 16 fetal livers (8 37 ml) in water using an Acuson 128XP/10 (5 MHz curvilinear probe). Volume was calculated using the ellipsoid, planimetry, tetrahedral and ray tracing methods and compared with the actual volume measured by weighing (balloons) and water displacement (kidneys and livers). The mean percentage error for the ray tracing method was 0.9 ± 2.4%, 2.7 ± 2.3%, 6.6 ± 5.4% for balloons, kidneys and livers, respectively. So far the system has been used clinically to scan fetal livers and lungs, neonate brain ventricles and adult prostate glands.
Resumo:
A new system is described for estimating volume from a series of multiplanar 2D ultrasound images. Ultrasound images are captured using a personal computer video digitizing card and an electromagnetic localization system is used to record the pose of the ultrasound images. The accuracy of the system was assessed by scanning four groups of ten cadaveric kidneys on four different ultrasound machines. Scan image planes were oriented either radially, in parallel or slanted at 30 C to the vertical. The cross-sectional images of the kidneys were traced using a mouse and the outline points transformed to 3D space using the Fastrak position and orientation data. Points on adjacent region of interest outlines were connected to form a triangle mesh and the volume of the kidneys estimated using the ellipsoid, planimetry, tetrahedral and ray tracing methods. There was little difference between the results for the different scan techniques or volume estimation algorithms, although, perhaps as expected, the ellipsoid results were the least precise. For radial scanning and ray tracing, the mean and standard deviation of the percentage errors for the four different machines were as follows: Hitachi EUB-240, −3.0 ± 2.7%; Tosbee RM3, −0.1 ± 2.3%; Hitachi EUB-415, 0.2 ± 2.3%; Acuson, 2.7 ± 2.3%.
Resumo:
Sixteen formalin-fixed foetal livers were scanned in vitro using a new system for estimating volume from a sequence of multiplanar 2D ultrasound images. Three different scan techniques were used (radial, parallel and slanted) and four volume estimation algorithms (ellipsoid, planimetry, tetrahedral and ray tracing). Actual liver volumes were measured by water displacement. Twelve of the sixteen livers also received x-ray computed tomography (CT) and magnetic resonance (MR) scans and the volumes were calculated using voxel counting and planimetry. The percentage accuracy (mean ± SD) was 5.3 ± 4.7%, −3.1 ± 9.6% and −0.03 ± 9.7% for ultrasound (radial scans, ray volumes), MR and CT (voxel counting) respectively. The new system may be useful for accurately estimating foetal liver volume in utero.