999 resultados para MAGE-ML
Resumo:
Blanks (flasks without substrate containing only inoculum and medium) are used in vitro to correct for gas. CH(4) and residual organic matter (OM) fermented in inoculum. However inclusion of rumen fermentation modifiers may affect fermentation of OM in the substrate and inoculum. Thus, data correction using blanks that lack additives may result in inaccurate adjustment for background fermentation. Our objective was to evaluate impacts of using blanks containing additive (i.e., specific blanks) or blanks without additive on estimation of in vitro net gas and CH(4) production. We used the semi-automatic in vitro gas production technique including monensin sodium at 2.08 mg/l of buffered rumen fluid (Experiment 1) or carvacrol, eugenol and 1,8-cineol at 667 mg/l (Experiment 2) in flasks with substrate and in blank flasks. At 16h of incubation, monensin reduced (P <= 0.02) total gas production in flasks containing substrate (162.0 ml versus 146.3 ml) and in blanks (84.4 ml versus 79.2 ml). Total methane production was also decreased (P <= 0.05) by adding monensin to flasks containing substrate (15.7 ml versus 11.9 ml) as well as in blanks (6.4 ml versus 5.0 ml). Inclusion of carvacrol or eugenol reduced (P <= 0.05) total gas and CH(4) production in flasks with substrate and in blanks, but in a more pronounced manner than monensin. For these three additives, correction for blank without additive resulted in lower net gas and CH(4) production than correction for a treatment specific blank. For instance, correcting carvacrol data using a blank without the additive resulted in negative net gas and CH(4) production (-6.5 and -1.5 ml. respectively). These biologically impossible results occurred because total gas and CH(4) production in blanks without carvacrol (46.1 and 2.1 ml, respectively) were higher than in flasks containing substrate plus carvacrol (39.7 and 0.6 ml, respectively). Results demonstrated that inclusion of rumen additives affected fermentation of OM in the substrate and the inoculum. Thus, correction of gas and CH(4) production using blanks without additives resulted in overestimation of these variables. Blanks containing the additive of interest should be included when rumen fermentation modifiers are evaluated in vitro. This paper is part of the special issue entitled: Greenhouse Gases in Animal Agriculture Finding a Balance between Food and Emissions, Guest Edited by T.A. McAllister, Section Guest Editors: K.A. Beauchemin, X. Hao, S. McGinn and Editor for Animal Feed Science and Technology, P.H. Robinson. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
An environmentally friendly analytical procedure with high sensitivity for determination of carbaryl pesticide in natural waters was developed. The flow system was designed with solenoid micro-pumps in order to improve mixing conditions and minimize reagent consumption as well as waste generation. A long pathlength (100 cm) flow cell based on a liquid core waveguide (LCW) was employed to increase the sensitivity in detection of the indophenol formed from the reaction between carbaryl and p-aminophenol (PAP). A clean-up step based on cloud-point extraction was explored to remove the interfering organic matter, avoiding the use of toxic organic solvents. A linear response was observed within the range 5-200 mu g L(-1) and the detection limit, coefficient of variation and sampling rate were estimated as 1.7 mu g L(-1) (99.7% confidence level), 0.7% (n=20) and 55 determinations per hour, respectively. The reagents consumption was 1.9 mu g of PAP and 5.7 mu g of potassium metaperiodate, with volume of 2.6 mL of effluent per determination. The proposed procedure was selective for the determination of carbaryl, without interference from other carbamate pesticides. Recoveries within 84% and 104% were estimated for carbaryl spiked to water samples and the results obtained were also in agreement with those found by a batch spectrophotometric procedure at the 95% confidence level. The waste of the analytical procedure was treated with potassium persulphate and ultraviolet irradiation, yielding a colorless residue and a decrease of 94% of total organic carbon. In addition, the residue after treatment was not toxic for Vibrio fischeri bacteria. (c) 2010 Elsevier B.V. All rights reserved.
Resumo:
An analytical procedure for multiple standard additions of arsenic species using sequential injection analysis (SIA) is proposed for their quantification in seafood extracts. SIA presented flexibility for generating multiple specie standards at the ng mL(-1) concentration level by adding different volumes of As(III), As(V), monomethylarsonic (MMA) and dimethylarsinic (DMA) to the sample. The mixed sample plus standard solutions were delivered from SIA to fill the HPLC injection loop. Subsequently, As species were separated by HPLC and analyzed by atomic fluorescence spectrometry (AFS). The proposed system comprised two independently controlled modules, with the HPLC loop acting as the intermediary device. The analytical frequency was enhanced by combining the actions of both modules. While the added sample was flowing through the chromatographic column towards the detection system, the SIA program started performing the standard additions to another sample. The proposed method was applied to spoiled seafood extracts. Detection limits based on 3 sigma for As(III), As(V), MMA and DMA were 0.023, 0.39, 0.45 and 1.0 ng mL(-1), respectively. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The determination of uric acid in urine shows clinical importance, once it can be related to human organism dysfunctions, such as gout. An analytical procedure employing a multicommuted flow system was developed for the determination of uric acid in urine samples. Cu(II) ions are reduced by uric acid to Cu(I) that can be quantified by spectrophotometry in the presence of 2,2`-biquinoline 4,4`-dicarboxylic acid (BCA). The analytical response was linear between 10 and 100 mu mol L(-1) uric acid with a detection limit of 3.0 mu mol L(-1) (99.7% confidence level). Coefficient of variation of 1.2% and sampling rate of 150 determinations per hour were achieved. Per determination, 32 mu g of CuSO(4) and 200 mu g of BCA were consumed, generating 2.0 mL of waste. Recoveries from 91 to 112% were estimated and the results for 7 urine samples agreed with those obtained by the commercially available enzymatic kit for determination of uric acid. The procedure required 100-fold dilution of urine samples, minimizing sample consumption and interfering effects. In order to avoid the manual dilution step, on-line sample dilution was achieved by a simple system reconfiguration attaining a sampling rate of 95 h(-1). (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
A procedure for simultaneous separation/preconcentration of copper. zinc, cadmium, and nickel in water samples, based on cloud point extraction (CPE) as a prior step to their determination by inductively coupled plasma optic emission spectrometry (ICP-OES), has been developed. The analytes reacted with 4-(2-pyridylazo)-resorcinol (PAR) at pH 5 to form hydrophobic chelates, which were separated and preconcentrated in a surfactant-rich phase of octylphenoxypolyethoxyethanol (Triton X-I 14). The parameters affecting the extraction efficiency of the proposed method, such as sample pH, complexing agent concentration, buffer amount, surfactant concentration, temperature, kinetics of complexation reaction, and incubation time were optimized and their respective values were 5, 0.6 mmol L(-1). 0.3 mL, 0.15% (w/v), 50 degrees C, 40 min, and 10 min for 15 mL of preconcentrated solution. The method presented precision (R.S.D.) between 1.3% and 2.6% (n = 9). The concentration factors with and without dilution of the surfactant-rich phase for the analytes ranged from 9.4 to 10.1 and from 94.0 to 100.1, respectively. The limits of detection (L.O.D.) obtained for copper, zinc, cadmium, and nickel were 1.2, 1.1, 1.0. and 6.3 mu g L(-1), respectively. The accuracy of the procedure was evaluated through recovery experiments on aqueous samples. (C) 2009 Published by Elsevier B.V.
Resumo:
Liquid-liquid microextraction without phase segmentation was implemented in a multicommuted flow system for determination of the anti-hypertensive diltiazem. The procedure was based on ion pair formation between the drug and the dye bromothymol blue at pH 3.5. The detection was performed without phase separation in a glass tube coupled to a fiber-optics spectrophotometer. The total volume of chloroform was reduced to 50 mu L in comparison with 10 mL consumed in batch. A linear response was observed between 9 and 120 mu mol L(-1), with a detection limit of 0.9 mu mol L(-1) (99.7% confidence level). The coefficient of variation (n = 10), sampling rate and extraction efficiency were estimated as 0.6%, 78 determinations per hour and 61%, respectively. About 30 mu g of bromothymol blue was consumed and the waste volume was 380 mu L per determination. The results for pharmaceutical samples agreed with those obtained by the reference procedure at the 95% confidence level. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The formation of the Mn(III)/EDTA complex in a flow system with solenoid micro-pumps was exploited for fast manganese determination in freshwater. Manganese(II) was oxidized in a solid-phase reactor containing lead dioxide immobilized on polyester. Long pathlength spectrophotometry was exploited to increase sensitivity, aiming to reach the threshold limit established by environmental legislation. A linear response was observed from 25 to 1500 mu g L(-1), with a detection limit of 6 mu g L(-1) (99.7% confidence level). Sample throughput and coefficient of variation were 36 samples/h and 2.6% (n = 10), respectively. EDTA consumption and waste generation were estimated as 500 mu g and 3 mL per determination, respectively. The amount of Pb in the residue corresponds to 250 mu g per determination and a solid-phase reactor could be used for up to 1600 determinations. Adsorption in active charcoal avoided interferences caused by organic matter and the developed procedure was successfully applied for determination of manganese in freshwater samples. Results were in agreement with those attained by GFAAS at the 95% confidence level. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
A procedure for partial digestion of bovine tissue is proposed using polytetrafluoroethylene (PTFE) microvessels inside a baby-bottle sterilizer under microwave radiation for multi-element determination by inductively coupled plasma optical emission spectrometry (ICP OES). Samples were directly weighed in laboratory-made polytetrafluoroethylene vessels. Nitric acid and hydrogen peroxide were added to the uncovered vessels, which were positioned inside the baby-bottle sterilizer, containing 500 mL of water. The hydrogen peroxide volume was fixed at 100 mu L The system was placed in a domestic microwave oven and partial digestion was carried out for the determination of Ca, Cu, Fe. Mg, Mn and Zn by inductively coupled plasma optical emission spectrometry. The single-vessel approach was used in the entire procedure, to minimize contamination in trace analysis. Better recoveries and lower residual carbon content (RCC) levels were obtained under the conditions established through a 2(4-1) fractional factorial design: 650 W microwave power, 7 min digestion time, 50 mu L nitric acid and 50 mg sample mass. The digestion efficiency was ascertained according to the residual carbon content determined by inductively coupled plasma optical emission spectrometry. The accuracy of the proposed procedure was checked against two certified reference materials. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The objectives of this study were to isolate psychrotrophic clostridia from Brazilian vacuum-packed beef cuts (spoiled or not) and to identify the isolates by using 16S rRNA gene sequencing. Anaerobic psychrotrophic microorganisms were also enumerated and samples were collected to verify the incidence of psychrotrophic clostridia in the abattoir environment. Vacuum-packed beef cuts (n = 8 grossly distended and n = 5 non-spoiled) and environmental samples were obtained from a beef packing plant located in the state of Sao Paulo, Brazil. Each sample was divided in three subsamples (exudate, beef surface and beef core) that were analyzed for vegetative forms, total spore-forming, and sulfide reducing spore-forming, both activated by alcohol and heat. Biochemical profiles of the isolates were obtained using API20A, with further identification using 16S rRNA gene sequencing. The growth temperature and the pH range were also assessed. Populations of psychrotrophic anaerobic vegetative microorganisms of up to 10(10) CFU/(g, mL or 100 cm(2)) were found in `blown pack` samples, while in non-spoiled samples populations of 10(5) CFU/(g, CFU/mL or CFU/100cm(2)) was found. Overall, a higher population of total spores and sulfide reducing spores activated by heat in spoiled samples was found. Clostridium gasigenes (n = 10) and C. algidicarnis (n = 2) were identified using 16S rRNA gene sequencing. Among the ten C. gasigenes isolates, six were from spoiled samples (C1, C2 and C9), two were isolated from non-spoiled samples (C4 and C5) and two were isolated from the hide and the abattoir corridor/beef cut conveyor belt. C. algidicarnis was recovered from spoiled beef packs (C2). Although some samples (C3, C7, C10 and C14) presented signs of `blown pack` spoilage, Clostridium was not recovered. C. algidicarnis (n = 1) and C. gasigenes (n = 9) isolates have shown a psychrotrophic behavior, grew in the range 6.2-8.2. This is the first report on the isolation of psychrotrophic Clostridium (C. gasigenes and C. algidicarnis) in Brazil. This study shows that psychrotrophic Clostridium may pose a risk for the stability of vacuum-packed beef produced in tropical countries during shelf-life and highlights the need of adopting control measures to reduce their incidence in abattoir and the occurrence of `blown pack` spoilage. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
A flow injection (FI) micelle-mediated separation/preconcentration procedure for the determination of lead and cadmium by flame atomic absorption spectrometry (FAAS) has been proposed. The analytes reacted with 1-(2-thiazolylazo)-2-naphthol (TAN) to form hydrophobic chelates, which were extracted into the micelles of 0.05% (w/v) Triton X-114 in a solution buffered at pH 8.4. In the preconcentration stage, the micellar solution was continuously injected into a flow system with four mini-columns packed with cotton, glass wool. or TNT compresses for phase separation. The analytes-containing micelles were eluted from the mini-columns by a stream of 3 mol L(-1) HCl solution and the analytes were determined by FAAS. Chemical and flow variables affecting the preconcentration of the analytes were studied. For 15 mL. of preconcentrated solution, the enhancement factors varied between 15.1 and 20.3, the limits of detection were approximately 4.5 and 0.75 mu g L(-1) for lead and cadmium, respectively. For a solution containing 100 and 10 mu g L(-1) of lead and cadmium, respectively, the R.S.D. values varied from 1.6 to 3.2% (n = 7). The accuracy of the preconcentration system was evaluated by recovery measurements on spiked water samples. The method was susceptible to matrix effects, but these interferences were minimized by adding barium ions as masking agent in the sample solutions, and recoveries from spiked sample varied in the range of 95.1-107.3%. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
A novel strategy for accomplishing zone trapping in flow analysis is proposed. The sample and the reagent solutions are simultaneously inserted into convergent carrier streams and the established zones merge together before reaching the detector, where the most concentrated portion of the entire sample zone is trapped. The main characteristics, potentialities and limitations of the strategy were critically evaluated in relation to an analogous flow system with zone stopping. When applied to the spectrophotometric determination of nitrite in river waters, the main figures of merit were maintained, exception made for the sampling frequency which was calculated as 189h(-1), about 32% higher relatively to the analogous system with zone stopping. The sample inserted volume can be increased up to 1.0 mL without affecting sampling frequency and no problems with pump heating or malfunctions were noted after 8-h operation of the system. In contrast to zone stopping, only a small portion of the sample zone is halted with zone trapping, leading to these beneficial effects. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
There are controversies about the use of local anesthetics during balloon compression for trigeminal neuralgia (TN) as a protective factor for cardiovascular events. The objective of this study was to investigate cardiovascular parameters (blood pressure and heart rate [HR]) of patients that underwent trigeminal balloon compression with local anesthetics compared to a control group (placebo). This is a randomized controlled study; 55 patients were randomized into two groups: study (deep sedation and trigeminal block with 0.8-mL lidocaine 2%) and control group (deep sedation and trigeminal injection of 0.8-mL saline). Blood pressure and HR were measured in five distinct moments: preoperative, during puncture for local anesthesia/placebo, during puncture with the catheter, during balloon compression, and final evaluation. Statistical analysis was performed with Pearson`s chi (2) and McNemar tests and the analysis of variance for repetitive measures. The means of systolic and diastolic blood pressures (SBP and DBP, respectively) were higher in the control group when compared to the study group at the evaluation during puncture with the catheter (p < 0.001) and balloon compression (p < 0.001 and p = 0.018 for DBP and SBP, respectively). There was an increase in the HR in the control group during the procedure (p = 0.017). The use of local anesthetics during the trigeminal balloon compression for TN can have a preventive role for the risk of cardiovascular events.
Resumo:
Background: The involvement of nephrotoxic agents in acute renal failure (ARF) has increased over the last few decades. Among the drugs associated with nephrotoxic ARF are the radiologic contrast media whose nephrotoxic effects have grown, following the increasing diagnostic use of these agents. Methods: We evaluated the effect of iodinated contrast (IC) medium, administered in combination, or not, with hyperhydration or N-acetylcysteine (NAC), on creatinine clearance, production of urinary peroxides and renal histology of rats. Adult Wistar rats treated for 5 days were divided into the following groups: control (saline, 3 ml/kg/day, intraperitoneally [i.p.]), IC (sodium iothalamate meglumine, 3 ml/kg/day i.p.), IC + water (12 mL water, orally + IC, 3 ml/kg/day i.p. after 1 hour), IC + NAC (NAC, 150 mg/kg/day, orally + IC, 3 ml/kg/day i.p. after 1 hour) and IC + water + NAC. Results: IC medium reduced renal function, with maintenance of urinary flow. Hyperhydration did not reduce the nephrotoxic effect of the IC agent, which was observed in the group IC + NAC. The combination of hyperhydration and NAC had no superior protective effect compared with NAC alone. An increase in urinary peroxides was observed in the IC group, with NAC or water or the combination of both reducing this parameter. Histopathologic analysis revealed no significant alterations. Conclusions: In summary, given 5 days previously, NAC was found to be more effective than hyperhydration alone in the prevention of contrast-induced acute renal failure.
Resumo:
Objective: to investigate the use of local anaesthetics, in the presence or absence of vasoconstrictors, for perineal repair during spontaneous delivery. Design: double-blind, randomised-controlled trial. Setting: a birth centre, in the city of Sao Paulo, Brazil. Participants: from June to December 2004, a total of 96 women were allocated into three groups (first-degree perineal lacerations, second-degree perineal lacerations or episiotomy), and treated with local anaesthesia (1% lidocaine or 1% lidocaine with epinephrine) (n = 16 per treatment per group). Interventions: an initial local infiltration of the anaesthetic solution was given so that episiotomy could be carried out (5 ml) and to suture spontaneous lacerations (1 ml), followed by repeated doses (1 ml) until pain was completely inhibited. Measurements and findings: the main outcome measurement was the volume of anaesthetic used during episiotomy and perineal suture. Our data suggest that the concomitant use of the vasoconstrictor resulted in a significantly lower average volume used in the treatment of first-degree (1 ml, 95% confidence interval (0) 0.4-1.6) and second-degree (3.7 ml, 95% CI 1.6-5.8) lacerations (p = 0.002 and 0.001, respectively). A 0.3 ml (95% CI 1.5-2.1) average decrease in anaesthetic volume was observed with episiotomy (p = 0.724). The maximum volume of anaesthetic used with and without vasoconstrictor was 1-2 ml in 95% and 3-4 ml in 50% of first-degree lacerations, respectively, and 1-6 ml in 88% and 7-15 ml in 81% of second-degree lacerations, respectively. For episiotomy, the maximum dose was 15 ml, regardless of anaesthetic solution used. Key conclusions: our data confirm the hypothesis that the use of anaesthetics in conjunction with vasoconstrictors is more effective than anaesthetics alone in the repair of perineal lacerations, but not for episiotomy. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Few studies have prospectively addressed the effects of exercise in the inflammatory activity of patients with coronary artery disease (CAD). We sought to evaluate the consequences of an acute bout of exercise on inflammatory markers and BNP in untrained CAD patients before and after randomization to a training program. 34 CAD patients underwent a 50-min acute exercise session on a cycle-ergometer at 65% peak oxygen uptake before and after blood sampling. They were then randomized to a 4-month chronic exercise program (15 patients) or general lifestyle recommendations (19 patients), undergoing a new acute session of exercise after that. In the overall population, acute exercise caused a significant increase in C-reactive protein [CRP; 1.79 (4.49) vs. 1.94 (4.89) mg/L, P < 0.001], monokine induced by interferon-gamma [Mig; 351 (324) vs. 373 (330) pg/mL, P = 0.027] and vascular adhesion molecule-1 [VCAM-1; 226 (82) vs. 252 (110) pg/mL, P = 0.02]. After 4-months, in exercise-trained patients, there was a significant decrease in the inflammatory response provoked by the acute exercise compared to patients in the control group reflected by a significant decrease in the differences between rest and post-exercise levels of CRP [-0.29 (0.84) mg/L vs. -0.11 (0.21) mg/L, P = 0.05]. Resting BNP was also significantly lower in exercise-trained patients when compared to untrained controls [15.6 (16.2) vs. 9.7 (11.4) pg/mL, P = 0.04 and 19.2 (27.8) vs. 23.2 (27.5) pg/mL, P = 0.76; respectively]. Chronic exercise training might partially reverse the inflammatory response caused by acute exercise in CAD patients. These results suggest that regular exercise is an important nonpharmacological strategy to the improvement in inflammation in CAD patients.